Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICP MS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7Li - CRADA 626 (Abstract)

The purpose of this project is to develop analytical methods that can be deployed for analysis of lithium isotope enrichment products. One method involves rapid, high-throughput, relatively low precision analysis for direct monitoring of enrichment processes. A second method involves slower, but more precise analysis of final products of the enrichment process. We will use commercially available analytical equipment (quadrupole base inductively coupled plasma mass spectrometry and multi-collector magnetic sector inductively coupled plasma mass spectrometry) so that the analytical methods developed can be applied broadly.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7 Li (CRADA 626) Final Report

The intent of this project was to determine appropriate methodologies for analysis of lithium isotopes for 1) quasi-online monitoring of isotope separations, and 2) high-precision characterization of end-products, including lithium fluoride and lithium-beryllium fluoride (FLiBe). Traditionally, isotopic analysis requires the use of expensive, sophisticated instrumentation with often relatively long analytical timelines. We determined that the use of cheaper, smaller, and easier-to-operate instruments are sufficient for rapid analysis of lithium isotopes to monitor isotope separation efficiencies. In addition, we found that the analytical precision afforded by these lower-cost instruments is comparable to the more sophisticated (i.e., more expensive) instrumentation when the isotopic composition of lithium becomes highly depleted in 6Li. This finding will ultimately help lower costs of manufacturing of depleted lithium that is required for operation of certain designs of Generation IV nuclear reactors.

07 ISOTOPE AND RADIATION SOURCES↗

Laser-Ablation ICP-MS Analyses of Meteoritic Metal Grains in Lunar Impact-Melt Breccias

Lunar impact-melt breccias contain metal grains from the meteorites that formed the breccias. Because the breccias contain clastic material that may derive from older breccias, metal grains from earlier impacts may be present, too. The large subset of moderately mafic (8 - 12% FeO), KREEP-rich ("LKFM") melt breccias is particularly important because: (1) these are the melt breccias most likely to have been produced in basin-forming impacts, (2) it is from these breccias that many of the approx. 3.9 Gyr ages that are so common in lunar samples derive, (3) the breccias contain large proportions of FeNi metal, more than 1% in some types of Apollo 16 breccias, and (4) the metal potentially provides information about the impactors causing the apparent cataclysm at 3.9 Gyr.

Korotev, R. L.↗

LA-ICP-MS Study of Trace Elements in the Chanuskij Metal

This progress report covers work done during the second year of the 3-year proposal. During this year we resolved many issues relevant to the analytical technique developed by us for measuring trace elements in meteoritic metals. This technique was used to measure concentrations of Fe, Ni, Co, Cr, Cu, Ga, Ge, As, Mo, Ru, Rh, Pd, Sb, W, Re, Os, Ir, Pt, and Au in eight large (120 - 160 microns) metal grains from both "igneous" and "metamorphic" lithologies of the Chanuskij silicate inclusions. The first application of OUT technique to metal grains from thin sections showed some limitations. Small thickness of metal grains in the thin section limited the signal to 3-4 time-slices instead of 10- 1 1 ones in polished sections of iron meteorites studied before.

Petaev, Michail I.↗

In Situ Analysis of Orthopyroxene in Diogenites Using Laser Ablation ICP-MS

Howardites, eucrites and diogenites (HED) form a suit of igneous achondrite meteorites that are thought to have formed on a single asteroidal body. While there have been many different models proposed for the formation of the HED parent asteroid they can be generalized into two end member models. One is the magma ocean model (e.g. [1]) in which the entire HED parent body was continuously fractionated from a planet wide magma ocean with diogenites representing the lower crust and eucrites being upper crustal rocks. The second model hypothesizes that diogenites and eucrites were formed as a series of intrusions and/or extrusions of partial melts of a primitive proto-Vesta [2]. We use in situ trace element analysis together with major and minor element analysis to try and distinguish between these different hypotheses for the evolution of the HED parent body.

Elk, Mattias↗

Data review processes in the analytical laboratory

These documents contain information on the Analytical laboratory data review processes for the following analytical techniques: - alpha spectrometry - light elements analyses - gamma spectrometry - gas proportional flow counting - HR-ICP-MS - Q-ICP-MS - MC-ICP-MS - ICP OES - liquid scintillation counting

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Certification of Uranium Isotope Amount Ratios in a Suite of Uranium Ore Concentrate Certified Reference Materials

Here, in this study, data from thirteen laboratories from around the world are presented for a successful certification of uranium isotope ratios in uranium ore concentrate (UOC) certified reference materials from the National Research Council Canada. Different mass spectrometric measurement principles (including SF-ICP-MS, quadruple ICP-MS, TIMS, MC-ICP-MS, SIMS and AMS) and measurement procedures were employed. In general, data from all sources exhibit good consistency with TIMS and MC-ICP-MS showing superior performance. The three candidate UOC CRMs (UCLO-1, UCHI-1 and UPER-1) have natural uranium isotope ratios with certified values of 0.5304(7) x 10 -4 , 0.5475(2) x 10 -4 and 0.5361(4) x 10 -4 for n( 234 U)/n( 238 U) and 0.007 2563(13), 0.007 2563(10) and 0.007 2542(11) for n( 235 U)/n( 238 U), respectively, with expanded uncertainty (k = 2) applicable to the last digit of the value given in the parentheses. Information values for n( 236 U)/n( 238 U) in these three CRMs, measured by AMS, are also provided: 10 x 10 -12 , 200 x 10 -12 and 22 x 10 -12 . The uncertainties of the proposed certified values of uranium isotope ratios in UOC CRMs are superior to available reference materials, and the values of n( 234 U)/n( 238 U) and n( 236 U)/n( 238 U) show significant variation among the three CRMs.

58 GEOSCIENCES↗

Optimized Microwave Digestion and Quantification Procedure for Boron Carbide samples

A microwave-assisted HNO3-H2SO4-HF digestion system was explored/optimized for the total dissolution of Boron Carbide samples followed by multi-elemental determination using ICP-MS and ICP OES, in order to improve the methods used in a previous try using a microwave-assisted H2O2-HNO3-HF digestion system. The samples were microwave digested to accomplish complete dissolution needed to perform quantitative analysis of their metal content. Two Boron Carbide samples were provided to us: JM10 and JM11. The Boron Carbide samples were completely dissolved at the end of the optimized microwave digestion procedure that was developed. The digested samples were analyzed for metals mostly by ICP MS; few elements were analyzed by ICP-OES. Microwave digestion reactions were performed in a Titan MPS instrument (Perkin Elmer, USA). Titan MPS instrument is equipped with Temperature and Pressure regulations and controlled by software. Each microwave digestion batch contained the samples of interest along with a reagent blank and one certified standard (1632e) in order to (i) compensate for the contaminations present in the reagents, (ii) ensure that the digestion was complete and (iii) that there was a good recovery of all the constituents. The certified standard used (1632e) was provided with USGS certificates of analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Humic Acid Complexation of Th, Hf and Zr in Ligand Competition Experiments: Metal Loading and Ph Effects

The mobility of metals in soils and subsurface aquifers is strongly affected by sorption and complexation with dissolved organic matter, oxyhydroxides, clay minerals, and inorganic ligands. Humic substances (HS) are organic macromolecules with functional groups that have a strong affinity for binding metals, such as actinides. Thorium, often studied as an analog for tetravalent actinides, has also been shown to strongly associate with dissolved and colloidal HS in natural waters. The effects of HS on the mobilization dynamics of actinides are of particular interest in risk assessment of nuclear waste repositories. Here, we present conditional equilibrium binding constants (Kc, MHA) of thorium, hafnium, and zirconium-humic acid complexes from ligand competition experiments using capillary electrophoresis coupled with ICP-MS (CE- ICP-MS). Equilibrium dialysis ligand exchange (EDLE) experiments using size exclusion via a 1000 Damembrane were also performed to validate the CE-ICP-MS analysis. Experiments were performed at pH 3.5-7 with solutions containing one tetravalent metal (Th, Hf, or Zr), Elliot soil humic acid (EHA) or Pahokee peat humic acid (PHA), and EDTA. CE-ICP-MS and EDLE experiments yielded nearly identical binding constants for the metal- humic acid complexes, indicating that both methods are appropriate for examining metal speciation at conditions lower than neutral pH. We find that tetravalent metals form strong complexes with humic acids, with Kc, MHA several orders of magnitude above REE-humic complexes. Experiments were conducted at a range of dissolved HA concentrations to examine the effect of [HA]/[Th] molar ratio on Kc, MHA. At low metal loading conditions (i.e. elevated [HA]/[Th] ratios) the ThHA binding constant reached values that were not affected by the relative abundance of humic acid and thorium. The importance of [HA]/[Th] molar ratios on constraining the equilibrium of MHA complexation is apparent when our estimated Kc, MHA values attained at very low metal loading conditions are compared to existing literature data. Overall, experimental data suggest that the tetravalent transition metal/-actinide-humic acid complexation is important over a wide range of pH values, including mildly acidic conditions, and thus, these complexes should be included in speciation models.

humic acid↗

Mapping of lanthanide-tagged proteins on western blot paper using microextraction-inductively coupled plasma-mass spectrometry

A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗