Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICCING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Analysis of Microseismicity and Reactivated Fault Size to Assess the Potential for Felt Events by CO 2 Injection in the Illinois Basin

The results of monitoring of carbon dioxide (CO 2 ) injection at the Illinois Basin—Decatur Project (IBDP) and the companion Illinois Industrial Carbon Capture and Sequestration Sources (IL-ICCS) project—have shown that reservoir response to fluid pressure changes can vary significantly at different injection locations within the same reservoir. Predrill reservoir characterization is important to identify potentially seismogenic faults. However, interpretations of newly reprocessed 3D seismic reflection data illustrate the challenges related to their identification in a region dominated by faulting with small vertical offsets. Faults interpreted in the 3D seismic volume range from ~300 to 1200 m wide and are in the same size range as faults that could have been the source of historical events up to Mw 2.7 in central Illinois. The array of monitoring sensors that was installed for the IBDP continues to collect data, as injection operates in IL-ICCS, the second injection well. CO 2 injection rates for the IL-ICCS well are on average 1.7 times the rates injected in the IBDP well, but a significantly reduced rate of induced seismicity is observed. This article presents results of passive seismic monitoring for the duration of the project to date, integrating active and passive seismic data to develop a new interpretation of the subsurface structure at the Decatur site that explicitly identifies pathways for fluid flow into the basement leading to induced seismicity, and provides a geological explanation for the sharp reduction of induced seismicity during injection at higher rates into the second well. The use of seismic moment to estimate the length of seismogenic slip planes in the local subsurface suggests that faults large enough to produce felt seismicity are unlikely to be present at or near the Decatur site.

Geochemistry & Geophysics↗

Small Hydro Reference Model Project (Final Project Report)

Small hydropower has long been developed in the United States, but still thousands of small hydro sites remain untapped. Most of them are technically and environmentally feasible but may not be cost-effective to develop at the current level of technology and carbon and fuel markets. This report aims to identify the cost drivers for small hydro generation through cost analyses, and to improve understanding of the pathways for cost reduction and the strategies for accelerating small hydro development in the United States. Reference to the empirical cost equations in literature, an initial capital cost (ICC) equation for nonpowered dam (NPD) and conduit projects has been preliminarily developed using limited project cost data collected from the Federal Energy Regulatory Commission (FERC) e-library and directly from industrial contacts. The regression analysis shows a correlation between the project ICC and plant capacity and head. The electro-mechanical equipment costs for Francis, axial flow, Kaplan, and propeller turbines are derived from the historical budget prices of a small hydro turbine manufacturer. These cost curves show the turbine-generator cost is also associated with the plant capacity and net head. In addition, the initial cost breakdowns are analyzed based on project cost data from literature and industry. It was found that the turbine-generator and the powerhouse are often the major cost components for low-head projects, whereas water conveyance is likely to be the key cost driver for high-head projects. The ICC variations for different site features, such as new greenfield sites vs. non-powered dams, are also discussed.

Zhang, Qin Fen (Katherine)↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

ConocoPhillips Sweeny IGCC/CCS Project

Under its Industrial Carbon Capture and Sequestration (ICCS) Program, the United States (U.S.) Department of Energy (DOE) selected ConocoPhillips Company (ConocoPhillips) to receive funding through the American Recovery and Reinvestment Act (ARRA) of 2009 for the proposed Sweeny Integrated Gasification Combined Cycle (IGCC)/Carbon Capture and Storage (CCS) Project (Project) to be located in Brazoria County, Texas. Under the program, the DOE is partnering with industry to demonstrate the commercial viability and operational readiness of technologies that would capture carbon dioxide (CO{sub 2}) emissions from industrial sources and either sequester those emissions, or beneficially reuse them. The primary objective of the proposed Project was to demonstrate the efficacy of advanced technologies that capture CO{sub 2} from a large industrial source and store the CO{sub 2} in underground formations, while achieving a successful business venture for the entity (entities) involved. The Project would capture 85% of the CO{sub 2} produced from a petroleum coke (petcoke) fed, 703 MWnet (1,000 MWgross) IGCC power plant, using the ConocoPhillips (COP) proprietary and commercially proven E-Gas{trademark} gasification technology, at the existing 247,000 barrel per day COP Sweeny Refinery. In addition, a number of other commercially available technologies would be integrated into a conventional IGCC Plant in a unique, efficient, and reliable design that would capture CO{sub 2}. The primary destination for the CO{sub 2} would be a depleted natural gas field suitable for CO{sub 2} storage ('Storage Facility'). COP would also develop commercial options to sell a portion of the IGCC Plant's CO{sub 2} output to the growing Gulf Coast enhanced oil recovery (EOR) market. The IGCC Plant would produce electric power for sale in the Electric Reliability Council of Texas Houston Zone. The existing refinery effluent water would be treated and reused to fulfill all process water needs. The DOE ICCS program adopts a two-phase approach. During the 7-month Phase 1 period, ConocoPhillips further defined the Project by advancing the preliminary design, permits, and contracts. In addition, ConocoPhillips was developing a Phase 2 renewal application to seek continued DOE funding for the Project's design, construction, and early operations. The DOE and ConocoPhillips entered into a Phase1 Cooperative Agreement (DOE Award Number DE-FE0001859) on November 16, 2009, agreeing to share cost on a 50/50 basis during the Phase 1 period, with a DOE budget of $2,989,174. On April 7, 2010, ConocoPhillips informed the DOE that it would not participate in Phase 2 of the DOE ICCS program. The company believes that enabling legislation and regulations at both the federal and state levels will not be approved and implemented in time to make a final investment decision such that the Project would be substantially constructed by September 30, 2015, the end of the AARA funding period. Considering current price assumptions, the Project would not generate investment level returns. ConocoPhillips elected not to submit a Phase 2 renewal application, which was due on April 16, 2010. This Final Scientific/Technical Report provides an overview of the Project, including highlights and benefits of the proposed carbon capture and storage project scope, sites, and technologies. It also summarizes the work accomplishments during the Phase 1 period from November 16, 2009 to June 16, 2010. Due to ConocoPhillips decision not to submit the Phase 2 renewal application and not to enter into related agreements, certain information regarding the proposed CO{sub 2} storage facility cannot be publicly reported due to confidentiality agreements.

01 COAL, LIGNITE, AND PEAT↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗

Reliability of Upright and Supine Power Measurements Using an Inertial Load Cycle Ergometer

Practical, reliable, and time efficient methods of measuring muscular power are desirable for both research and applied testing situations. The inertial-load cycling method (ILC; Power/Cycle, Austin, TX) requires subjects to pedal as fast as possible against the inertial load of a flywheel for only 3-5 seconds, which could help reduce the time and effort required for maximal power testing. PURPOSE: 1) To test the intramachine reliability of ILC over 3 separate sessions, 2) to compare postural stance (upright vs. supine) during testing, and 3) to compare the maximal power (Pmax) output measured using ILC to that obtained from traditional isokinetic and leg press testing. METHODS: Subjects (n = 12) were tested on 4 non-consecutive days. The following tests were done on the first day of testing: isometric knee extension, isokinetic knee extension at several speeds, isokinetic power/endurance at 180/sec (Biodex System 4), leg press maximal isometric force, and leg press power/endurance. The other 3 days consisted exclusively of ILC testing. Subjects performed 6 ILC tests in an upright position and 6 ILC tests in a supine position on each day. The starting position was counterbalanced. Mixed-effects linear modeling was used to determine if any differences existed between testing days and between upright and supine for Pmax and revolutions per minute at Pmax (RPMpk). Mixed-modeling was also used to calculate intraclass correlation coefficients (ICC) to determine the reliability of the ILC on each testing day for Pmax and RPMpk (ICCs were calculated separately for upright and supine). gKendall fs Tau a h was used to determine the association between ILC Pmax and isokinetic and leg press data. RESULTS: For Pmax, significant differences were found between days 1 and 2 (upright: p = 0.018; supine: p = 0.014) and between days 1 and 3 (upright: p = 0.001; supine: p = 0.002), but not between days 2 and 3 (upright: p = 0.422; supine: p = 0.501). Pmax ICC values were greater than or equal to 0.97 for all days in both positions. Also, no significant differences between upright and supine postures were found for Pmax. No significant differences between days were found for RPMpk; however, there was a significant posture effect (upright greater than supine). Moderate correlations were observed between ILC Pmax and isokinetic and leg press tests (upright: 0.64-0.79, supine: 0.52-0.82). CONCLUSIONS: Overall, ILC is a very reliable test. Since a significant difference was found between day 1 and the other ILC testing days, it is suggested that day 1 of ILC testing should be used as a familiarization session to allow for subject learning. No significant difference in Pmax was seen from test 3 to test 6. However, an increase of 1.3% was observed from test 4 to test 6. Therefore, although 4 tests may be sufficient for most subjects to produce Pmax, in some cases 6 tests may be required. PRACTICAL APPLICATIONS: No differences were seen in Pmax between upright and supine positions despite differing RPMpk. This suggests that ILC testing can be used to provide reliable testing both in an upright position (appropriate for athletes) and in research (e.g., bed rest) or rehabilitation settings where supine testing is necessary. Future research should evaluate whether peak power measurements obtained with the ILC are sensitive to changes such as that observed with training and de-training.

Wickwire, P. J.↗

Validity and Reliability of Dynamic Visual Acuity (DVA) Measurement During Walking

DVA is primarily subserved by the vestibulo‐ocular reflex mechanism. Individuals with vestibular hypofunction commonly experience highly debilitating illusory movement or blurring of visual images during daily activities possibly, due to impaired DVA. Even without pathologies, gradual age‐related morphological deterioration is evident in all components of the vestibular system. We examined the construct validity to detect age‐related differences and test‐retest reliability of DVA measurements performed during walking. METHODS: Healthy adults were recruited into 3 groups: 1. young (20‐39years, n=18), 2. middle‐aged (40‐59years, n=14), and 3. older adults (60‐80years, n=15). Randomly selected seven participants from each group (n=21) participated in retesting. Participants were excluded if they had a history of vestibular or neuromuscular pathologies, dizziness/vertigo or >1 falls in the past year. Older persons with MMSE scores <29/30 were excluded to minimize cognitive errors. Participants' age, height, weight and normal walking speed were recorded. The binocular DVA was measured while walking on a treadmill at 0.8 m/s, 1.0 m/s and 1.2 m/s speeds. The walking speeds chosen represent a range of slow to moderate walking speeds for adult life span in participants who have no current mobility problems. The monitor that displayed Landolt 'C' optotypes was placed at 50 cm from the eyes for nearDVA (primary compensation by otolith organs) and at 3.0 m for farDVA (primary compensation by semicircular canals). A mixed factor ANOVA (age group x speed) was performed separately for the Near and FarDVA for detecting group differences. Intraclass correlation coefficients (ICCs) were calculated for each condition to determine test‐retest reliability. RESULTS: The three age groups were not different in their height, weight and normal walking speed (p>0.05). The post hoc analyses for DVA measurements demonstrated that each group was significantly different from the other two groups for Near as well as FarDVA (p<0.001‐p=0.031). The effect of speed was significant for both NearDVA (p=0.012) and FarDVA (p=0.014), however, there was no age group x speed interaction (FarDVA p=0.607, NearDVA p=0.343). The ICCs for Near and FarDVA ranged between 0.85‐ 0.88 and 0.71‐0.87, respectively. CONCLUSIONS: Differences in DVA between the three age groups were detected by using both Near and FarDVA protocols irrespective of the walking speed. Therefore, age group‐specific reference values should be used for detecting malfunction. Further, consistency in walking speed is critical for comparing between studies. NearDVA at all walking speeds and FarDVA at the speed of 1.2 m/s demonstrated excellent testretest reliability. FarDVA at 0.8 m/s and 1.0 m/s demonstrated good test‐retest reliability (ICCs 0.71 and 0.77, respectively).

Deshpande, Nandini↗

The Nitty Gritty: How We Make Analogs Work

NASA's Human Research Program (HRP) is becoming increasingly reliant on Isolated, Confined and Controlled (ICC) analogs to accomplish many of its research objectives. Compared to other research platforms, ICC analogs present a unique set of operational challenges that must be addressed in order to ensure a high fidelity research environment. In particular, the Human Exploration Research Analog (HERA) habitat, which is classified as an ICC environment, has been developed over the past three years to accommodate the operational needs of research investigations from each of the HRP Elements. During the development period, various types of requirements have contributed to the current operational model, which strives to achieve the highest possible level of mission fidelity with limited resources. This presentation will focus on the operational aspects of the HERA habitat, with emphasis on how we develop the analog research environment to meet researchers' needs. Specific discussion topics include mission scenario development, operational tasks, mission timeline integration, stressor implementation, console support, and improvements based on lessons learned. The information is intended to help investigators better understand the details behind HERA operations and the benefits to their research goals.

Self, A. L.↗

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

NSCOR for Evaluating Risk Factors and Biomarkers for Adaptation and Resilience to Spaceflight: Emotional Valence and Social Processes in ICC/ICE Environments

Space exploration class missions, such as a mission to Mars, will require optimization of human performance, adaptability, and resilience. This NASA Specialized Center of Research (NSCOR) utilizes the NIMH Research Domain Criteria (RDoC) framework to identify biological and behavioral markers of individual social adaptation and emotional resilience (as well as vulnerability) to spaceflight-relevant stressors such as living in extended isolation. The overarching goal of this NSCOR is to obtain novel information to help identify biomarkers of individuals who are resilient and/or adaptable to the stressors of isolated, confined, and controlled (ICC) and isolated, confined, and extreme (ICE) environments.A total of N=90 healthy adult astronaut surrogates are being studied in three spaceflight-analog environments: (1) n=40 healthy adults in the Isolation and Confinement Analog Research Unit (ICARUS), an ICC at the University of Pennsylvania, during 7-day missions, for a target total of 280 subject days; (2) n=32 healthy adult astronaut surrogates studied in NASA’s Human Exploration Research Analog (HERA), an ICC at Johnson Space Center during 45-day missions, for a target total of 2,112 subject days; and (3) n=18 healthy adults in the Alfred-Wegener-Institute’s Neumayer Station III, an ICE in Antarctica, during 14-month missions, for a target total of 7,560 subject days. Dr. Nindl’s Laboratory at the University of Pittsburgh is analyzing a priori selected protein biomarkers in blood, saliva, and urine. Complementary rodent models of exposure to early life stressors, confinement, and isolation are being evaluated at Dr. Hensch’s Laboratory to further validate the neurobehavioral and biological findings from the human studies.Given the inconsistency and varied definition of resilience/adaptation in the scientific literature, the NSCOR team developed a composite resilience/adaptation measure that reflects the most relevant outcomes to resilience/adaptation across psychosocial and neurobehavioral functions, as well as neurocognitive and spaceflight-relevant operational performance. To achieve this, group consensus was attained from subject matter experts to produce a rank-order of importance for each input variable. The final resilience/adaptation score included 36 variables that were collected across spaceflight analogs. As of 10/1/2021, the NSCOR project acquired data on n=27 subjects at ICARUS, n=16 at HERA, and n=18 at Neumayer. The COVID-19 pandemic delayed data acquisition at ICARUS and HERA.Among subjects studied to date, 99% of neural and neurobehavioral data (e.g., neuroimaging for structure and function, behavioral measures) as well as blood, saliva, and urine for biochemical assays have been acquired. For rodent models, Dr. Hensch’s laboratory has established biochemical and behavioral parameters reflecting confinement stress in social networks of mice for comparison to stress responses in the human spaceflight analog environments.Group social behaviors were measured with a Social Network Analysis (SNA) approach to define objective parameters associated with sociability and its plasticity by sex. This analytic approach may help identify a network of individuals who are more effective teammates or more likely to generate new social relationships. Data acquisition, biomarker assessment, and data quality control will continue through September 2022.

D F Dinges↗

Maquoketa Shale Caprock Integrity Evaluation

The Knox Project objective is to evaluate the potential of formations within the Cambrian-Ordovician strata above the Mt. Simon Sandstone (St. Peter Sandstone and Potosi Dolomite) as potential targets for carbon dioxide (CO2) sequestration in the Illinois and Michigan Basins. The suitability of the St. Peter Sandstone and Potosi Dolomite to serve as reservoirs for CO2 sequestration is discussed in separate reports. In this report the data gathered from the Knox project, the Illinois Basin – Decatur Project (IBDP) and Illinois Industrial Carbon Capture and Sequestration project (IL-ICCS) are used to make some conclusions about the suitability of the Maquoketa shale as a confining layer for CO2 sequestration. These conclusions are then upscaled to basin-wide inferences based on regional knowledge. Data and interpretations (stratigraphic, petrophysical, fractures, geochemical, risk, seismic) applicable to the Maquoketa Shale from the above mentioned projects was inventoried and summarized. Based on the analysis of these data and interpretations, the Maquoketa Shale is considered to be an effective caprock for a CO2 injection project in either the Potosi Dolomite or St. Peter Sandstone because it has a suitable thickness (~200ft. ~61m), advantageous petrophysical properties (low effective porosity and low permeability), favorable geomechanical properties, an absence of observable fractures and is regionally extensive. Because it is unlikely that CO2 would migrate upward through the Maquoketa Shale, CO2, impact to above lying fresh water aquifers is unlikely. Furthermore, the observations indicate that CO2 injected into the St. Peter Sandstone or Potosi Dolomite may never even migrate up into the Maquoketa Shale at a high enough concentrations or pressure to threaten the integrity of the caprock. Site specific conclusions were reached by unifying the data and conclusions from the IBDP, ICCS and the Knox projects. In the Illinois Basin, as one looks further away from these sites, the formation characteristics are expected to vary. The degree of how well this data can be extrapolated throughout the Basins (regionalized) is difficult to quantify because of the limited amount of data collected on the Maquoketa Shale away from IBDP, IL-ICCS and the Knox projects. Data gathered from the IBDP/IL-ICCS/Knox projects were used to make conclusions about the suitability of the Maquoketa shale as a confining layer for CO2 sequestration. This study indicates that the Maquoketa Shale would be a suitable caprock for a CO2 injection program in either the Potosi Dolomite or St. Peter Sandstone.

Leetaru, Hannes↗

2015 IECC: Energy Savings Analysis

Section 304(a) of the Energy Conservation and Production Act, as amended, requires the Secretary of Energy to make a determination each time a revised edition of the 1992 Model Energy Code (MEC), or any successor thereof, is published with respect to whether the revised code would improve energy efficiency in residential buildings. The International Energy Conservation Code (IECC), as administered by the International Code Council (ICC), establishes the national model code for energy efficiency requirements for residential buildings. The latest edition of the IECC, the 2015 IECC, was published on June 3, 2014 and forms the basis of this analysis. To meet these statutory requirements, as well as to assist states and adopting entities in understanding associated savings, the DOE Building Energy Codes Program and Pacific Northwest National Laboratory (PNNL) conduct analyses to evaluate the differences between the latest edition of the IECC and its immediate predecessor. A qualitative analysis is conducted, identifying all changes made to the previous edition of the IECC, and characterizing these changes in terms of their anticipated impact on residential building energy consumption. A quantitative analysis is then modeled through building energy simulation to estimate the resulting energy impacts. This report documents the technical analysis used to evaluate whether residential buildings constructed to meet the requirements of the 2015 IECC would result in energy efficiency improvements over residential buildings constructed to meet the requirements of the previous edition, the 2012 IECC. PNNL considered all code change proposals approved for inclusion in the 2015 IECC during the ICC code development cycle, and evaluated their combined impact on a suite of prototypical residential building energy models across all U.S. climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comprehensive Material Characterization and Simultaneous Model Calibration for Improved Computational Simulation Credibility

Computational simulation is increasingly relied upon for high-consequence engineering decisions, and a foundational element to solid mechanics simulations is a credible material model. Our ultimate vision is to interlace material characterization and model calibration in a real-time feedback loop, where the current model calibration results will drive the experiment to load regimes that add the most useful information to reduce parameter uncertainty. The current work investigated one key step to this Interlaced Characterization and Calibration (ICC) paradigm, using a finite load-path tree to incorporate history/path dependency of nonlinear material models into a network of surrogate models that replace computationally-expensive finite-element analyses. Our reference simulation was an elastoplastic material point subject to biaxial deformation with a Hill anisotropic yield criterion. Training data was generated using either a space-filling or adaptive sampling method, and surrogates were built using either Gaussian process or polynomial chaos expansion methods. Surrogate error was evaluated to be on the order of 10 ⁻5 and 10 ⁻3 percent for the space-filling and adaptive sampling training data, respectively. Direct Bayesian inference was performed with the surrogate network and with the reference material point simulator, and results agreed to within 3 significant figures for the mean parameter values, with a reduction in computational cost over 5 orders of magnitude. These results bought down risk regarding the surrogate network and facilitated a successful FY22-24 full LDRD proposal to research and develop the complete ICC paradigm.

36 MATERIALS SCIENCE↗

Diagnostic accuracy of MRI with extracellular vs. hepatobiliary contrast material for detection of residual hepatocellular carcinoma after locoregional treatment

Purpose: To compare the diagnostic accuracy of extracellular gadolinium-based contrast-enhanced MRI (Gd-MRI) and gadoxetic acid-enhanced MRI (EOB-MRI) for the assessment of hepatocellular carcinoma (HCC) response to locoregional therapy (LRT) using explant correlation as the reference standard. Methods: Forty-nine subjects with cirrhosis and HCC treated with LRT who underwent liver MRI using either Gd-MRI (n = 26) or EOB-MRI (n = 23) within 90 days of liver transplantation were included. Four radiologists reviewed the MR images blinded to histology to determine the size and percentage of viable residual HCC using a per-lesion explant reference standard. Sensitivities, specificities, accuracies, and agreement with histology for the detection residual HCC were calculated. Results: Gd-MRI had greater agreement with histology (ICC: 0.98 [0.95–0.99] vs. 0.80 [0.63–0.90]) and greater sensitivity for viable HCC (76% [13/17 50–93%] vs. 58% [7/12; 28–85%]) than EOB-MRI; specificities were similar (84% [16/19; 60–97%] vs. 85% [23/27; 66–96%]). Areas under ROC curves for detecting residual viable tumor were 0.80 (0.64–0.92) for Gd-MRI and 0.72 (0.55–0.85) for EOB-MRI. Gd-MRI had greater inter-rater agreement than EOB-MRI for determining the size of residual viable HCC (ICC: 0.96 [0.92–0.98] vs. 0.85 [0.72–0.92]). Conclusion: Gd-MRI may be more accurate and precise than EOB-MRI for the assessment of viable HCC following LRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The role of contrast-enhanced computed tomography to detect renal stones

Purpose: To investigate the detectability of renal stones in corticomedullary and nephrographic phases on contrast-enhanced computed tomography (CT). Methods: All consecutive patients between January 2012 and February 2016 undergoing CT of the kidneys according to our department’s standard four-phase protocol and having at least one stone in the NC-phase (NCP) were included. Fifty patients with altogether 136 stones were eligible. Two radiologists in consensus evaluated the NCP from each examination and documented the number, location, and size of stones. Three abdominal radiologists blinded to the findings of the NCP reviewed independently the corticomedullary and nephrographic phases on two different occasions. They reported the number and location of stones in each kidney. For the inter-observer agreement the intra-class correlation coefficient (ICC) was estimated. The detection rate of renal stones was calculated for the three radiologists and compared between the two contrast-enhanced phases and the results were analyzed with concern to the size of the stones. Results: The ICC was 0.86. There was no statistically significant difference between corticomedullary and nephrographic phases (p = 0.94). The detection rate for stones measuring 3–5 mm was 82–88% and 98% for stones ≥ 6 mm. Conclusion: The detectability of renal stones ≥ 6 mm on contrast-enhanced CT is extremely high. This means that stones with a higher risk of not passing spontaneously can be safely diagnosed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of the Virtual Liver Parenchymal Perfusion Area Using a Commercially Available Workstation in Transarterial Chemoembolization for Hepatocellular Carcinoma

Purpose: To evaluate the accuracy of the virtual liver parenchymal perfusion area using a commercially available workstation and liver analysis software in conventional transarterial chemoembolization (cTACE) for hepatocellular carcinoma (HCC). Materials and Methods: This method was retrospectively applied to 29 treated HCCs in 23 patients. The virtual embolic area (VEA) was estimated based on cone beam computed tomography during hepatic arteriography using a commercially available workstation and liver analysis software by two observer groups (group A: experts; group B: semi-experts). The real embolic area (REA) was defined as the area where iodized oil accumulated on computed tomography at 1 week after cTACE. The REA was estimated by each of the two groups, and the mean REA between the groups (mREA) was used as a standard reference. Agreement of volume and cross-sectional area in three orthogonal planes between the VEA and mREA were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The ICCs for volume between VEA and mREA were 0.97 and 0.88 for groups A and B, respectively, and those for cross-sectional area were 0.94 and 0.88 for the axial plane, 0.95 and 0.83 for the coronal plane, and 0.87 and 0.74 for the sagittal plane, respectively. Thus, the overall agreement was excellent, except for the sagittal imaging plane in group B. Conclusion: This method using a commercially available workstation and liver analysis software can be useful for estimating the embolic area in cTACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume-based glucose metabolic analysis of FDG PET/CT: The optimum threshold and conditions to suppress physiological myocardial uptake

Objective: FDG PET/CT plays a significant role in the diagnosis of inflammatory heart diseases and cardiac tumors. We attempted to determine the optimal FDG uptake threshold for volume-based analyses and to evaluate the relationship between the myocardial physiological uptake volume in FDG PET and several clinical factors. Methods: A total of 190 patients were retrospectively analyzed. The cardiac metabolic volume (CMV) was defined as a volume within the boundary determined by a threshold (SUVmean of blood pool × 1.5). Results: The SUVmean of the blood pool measured in the descending aorta (DA) (r = 0.86, intraclass correlation coefficient [ICC] = 0.93, P < 0.0001) and that in the left ventricle (LV) cavity (r = 0.87, ICC = 0.90, P < 0.0001) showed high inter-operator reproducibility. However, the SUVmean in the LV cavity showed a significant correlation with the CMV (P = 0.0002, r = 0.26). The CMV in the patients who fasted < 18 hours were significantly higher (49.7 ± 73.2 vs. 18.0 ± 53.8 mL, P = 0.0013) compared to the patients with > 18-hour fasting. The multivariate analysis demonstrated that only the fasting period > 18 hours was independently associated with CMV = 0. Conclusion: Our findings revealed that the DA is suitable to decide the threshold for the volume-based analysis. The fasting time was significantly associated with the cardiac FDG uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of Targeted Intraoperative Radiotherapy (Targit) Boost During Breast-Conserving Surgery

Purpose: We have previously shown that delivering targeted radiotherapy to the tumour bed intraoperatively is feasible and desirable. In this study, we report on the feasibility, safety, and long-term efficacy of TARGeted Intraoperative radioTherapy (Targit), using the Intrabeam system. Methods and Materials: A total of 300 cancers in 299 unselected patients underwent breast-conserving surgery and Targit as a boost to the tumor bed. After lumpectomy, a single dose of 20 Gy was delivered intraoperatively. Postoperative external beam whole-breast radiotherapy excluded the usual boost. We also performed a novel individualized case control (ICC) analysis that computed the expected recurrences for the cohort by estimating the risk of recurrence for each patient using their characteristics and follow-up period. Results: The treatment was well tolerated. The median follow up was 60.5 months (range, 10-122 months). Eight patients have had ipsilateral recurrence: 5-year Kaplan Meier estimate for ipsilateral recurrence is 1.73% (SE 0.77), which compares well with that seen in the boosted patients in the European Organization for Research and Treatment of Cancer study (4.3%) and the UK STAndardisation of breast RadioTherapy study (2.8%). In a novel ICC analysis of 242 of the patients, we estimated that there should be 11.4 recurrences; in this group, only 6 recurrences were observed. Conclusions: Lumpectomy and Targit boost combined with external beam radiotherapy results in a low local recurrence rate in a standard risk patient population. Accurate localization and the immediacy of the treatment that has a favorable effect on tumour microenvironment may contribute to this effect. These long-term data establish the long-term safety and efficacy of the Targit technique and generate the hypothesis that Targit boost might be superior to an external beam boost in its efficacy and justifies a randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗