Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Formation of Cirrus Clouds near the Tropical Tropopause and Their Implications for Stratospheric Humidity, Radiation Budgets, and Climate

Optically-thin cirrus clouds are a nearly ubiquitous feature of the transition layer between the tropical troposphere and stratosphere (known as the Tropical Tropopause Layer). Given their high occurrence frequency, these clouds have significant impacts on the Earth's radiation budget, with a particularly strong influence on the outgoing longwave radiation. Further, ice crystal growth and sedimentation in these clouds dehydrates air in the cold TTL to very low water vapor mixing ratios. Since transport from the troposphere into the stratosphere occurs primarily through the tropical tropopause and the Brewer-Dobson circulation transports air from the TTL throughout the stratosphere, cloud processes in the TTL cold trap essentially regulate the humidity of the entire stratosphere. It has been shown that even small changes in stratospheric humidity can have significant impacts on the Earth's radiation budget and climate, with magnitudes comparable to anthropogenic changes in greenhouse gases. The humidity of air crossing the TTL cold trap depends to first order on tropical tropopause temperatures, but also on deep convection reaching the TTL, large-scale transport (in balance with TTL radiative heating), atmospheric waves, and cloud microphysical processes. Gaps in our understanding of TTL transport and cloud processes motivated the NASA Airborne Tropical TRopopause EXperiment (ATTREX). ATTREX used the long-range (16,000 km), high-altitude (20 km) Global Hawk unmanned aircraft system equipped with twelve instruments measuring clouds, water vapor, meteorological conditions, chemical tracers, chemical radicals, and radiation. I will discuss the physics of TTL cirrus formation and the impact of these clouds on water vapor and radiation budgets, including new results emerging from the ATTREX measurements.

Jensen, Eric↗

Evaluation of a Combined Drought Indicator Against Crop Yield Estimations and Simulations Over the Argentine Humid Pampas

Droughts pose serious threats to the agricultural sector, especially in rainfed-dominated agricultural regions like those in Argentina’s Humid Pampas. This region was recently impacted by slow-evolving and long-lasting droughts as well as by flash droughts, resulting in losses reaching thousands of millions of US dollars. Improvements of drought early warning systems are essential, particularly given the projected increase in drought frequency and severity over southern South America. The spatial and temporal relationship between precipitation deficits, soil moisture and vegetation health anomalies are crucial for better understanding and representation of the agricultural droughts and their impacts. In this context, the Combined Drought Indicator (CDI) considers the causal and time-lagged relationship of these three variables. The study’s objective is twofold: (1) Analyze the time-lagged response between precipitation deficits, soil moisture and satellite fAPAR anomalies; and (2) Evaluate the CDI’s capability to characterize the severity of drought events on the Humid Pampas against agricultural yield estimations and simulations, as well as agricultural emergency declarations. The correlation among the variables shows strong spatial variability. The highest Pearson correlation values (r > 0.42) are observed over parts of the Humid Pampas for time lags of 0, 10, and 20 days between the variables. Although the CDI has limitations, such as its coarse spatial resolution and monthly temporal resolution of precipitation data, it effectively tracks the progression of major drought events in the region. The CDI’s performance aligns well with estimations and simulations of soybean and corn yields, as well as official declarations of agricultural emergencies. Insights from this study also provide a basis for discussing potential improvements to the CDI. This study highlights the global and regional significance of evaluating and enhancing the CDI for effective drought monitoring, emphasizing the role of collaborative efforts for future advancements in drought early warning systems.

Combined Drought Indicator↗

Remote query measurement of pressure, fluid-flow velocity, and humidity using magnetoelastic thick-film sensors

Free-standing magnetoelastic thick-film sensors have a characteristic resonant frequency that can be determined by monitoring the magnetic flux emitted from the sensor in response to a time varying magnetic field. This property allows the sensors to be monitored remotely without the use of direct physical connections, such as wires, enabling measurement of environmental parameters from within sealed, opaque containers. In this work, we report on application of magnetoelastic sensors to measurement of atmospheric pressure, fluid-flow velocity, temperature, and mass load. Mass loading effects are demonstrated by fabrication of a remote query humidity sensor, made by coating the magnetoelastic thick film with a thin layer of solgel deposited Al2O3 that reversibly changes mass in response to humidity. c2000 Elsevier Science S.A. All rights reserved.

NASA Discipline Life Sciences Technologies↗

Magnetoelastic sensors in combination with nanometer-scale honeycombed thin film ceramic TiO2 for remote query measurement of humidity

Ribbonlike magnetoelastic sensors can be considered the magnetic analog of an acoustic bell; in response to an externally applied magnetic field impulse the sensors emit magnetic flux with a characteristic resonant frequency. The magnetic flux can be detected external to the test area using a pick-up coil, enabling query remote monitoring of the sensor. The characteristic resonant frequency of a magnetoelastic sensor changes in response to mass loads. [L.D. Landau and E. M. Lifshitz, Theory of Elasticity, 3rd ed. (Pergamon, New York, 1986). p. 100].Therefore, remote query chemical sensors can be fabricated by combining the magnetoelastic sensors with a mass changing, chemically responsive layer. In this work magnetoelastic sensors are coated with humidity-sensitive thin films of ceramic, nanodimensionally porous TiO2 to make remote query humidity sensors. c2000 American Institute of Physics.

NASA Discipline Life Sciences Technologies↗

Temperature and Humidity Dependence of a Polymer-Based Gas Sensor

This paper quantifies the temperature and humidity dependence of a polymer-based gas sensor. The measurement and analysis of three polymers indicates that resistance changes in the polymer films, due to temperature and humidity, can be positive or negative. The temperature sensitivity ranged from +1600 to -320 ppm/nd the relative sensitivity ranged from +1100 to -260 ppm/%.

temperature humidity gas sensor polymers↗

VAB Temperature and Humidity Study

In 2012, 17 data loggers were placed in the VAB to measure temperature and humidity at 10-minute intervals over a one-year period. In 2013, the data loggers were replaced with an upgraded model and slight adjustments to their locations were made to reduce direct solar heating effects. The data acquired by the data loggers was compared to temperature data provided by three wind towers located around the building. It was found that the VAB acts as a large thermal filter, delaying and reducing the thermal oscillations occurring outside of the building. This filtering is typically more pronounced at higher locations in the building, probably because these locations have less thermal connection with the outside. We surmise that the lower elevations respond more to outside temperature variations because of air flow through the doors. Temperatures inside the VAB rarely exceed outdoor temperatures, only doing so when measurements are made directly on a surface with connection to the outside (such as a door or wall) or when solar radiation falls directly on the sensor. A thermal model is presented to yield approximate filter response times for various locations in the building. Appendix A contains historical thermal and humidity data from 1994 to 2009.

Temperature↗

Convective Influence on the Humidity and Clouds in the Tropical Tropopause Layer During Boreal Summer

The impact of convection on the humidity and clouds in the tropical tropopause layer (TTL) during boreal summer 2007 is investigated in simulations of detailed cloud microphysical processes and their effects on the water vapor (H2O) profile along backward trajectories from the 379 K potential temperature (100‐hPa pressure) surface. Convective influence is determined by tracing the trajectories through time‐dependent fields of satellite‐based convective cloud top height. The simulated H2O mixing ratios at the 100‐hPa level and cloud occurrence fractions in the middle to upper (16–18 km) TTL exhibit a pronounced maximum over the Asian monsoon region as in observations; these local enhancements are virtually absent in the simulation without convection, indicating that convection is the dominant driver of the localized H2O and cloud maxima in the Asian summer monsoon region. Convection moistens the 100‐hPa level by 0.6 ppmv (~15%) averaged over the 10°S–50°N domain and increases tropical (10°S–30°N) mean cloud occurrence in the middle to upper TTL by ~170%. Nearly all of the convective enhancements in H2O and clouds are due to the effect of convective saturation; convectively detrained ice crystals have negligible impact. Parcels are most frequently hydrated by deep convection in the southern sector of the Asian monsoon anticyclone and subsequently dehydrated downstream of convection to the west, shifting the locations of final dehydration northwest of the cold temperature region in the northern Tropics. Infrequent, extreme deep convective systems (cloud tops exceeding 380 K) have a disproportionately large effect on TTL humidity and clouds.

Humidity↗

Temperature and humidity control of simulated human breath

Subsystem was developed for breathing metabolic simulator which adjusts temperature and humidity of air to levels of human exhaled breath. Temperature-humidity subsystem is described, consisting of aluminum enclosure with 400 watt heat sheet glued to bottom, vertical separators, inlet connection, and check valve.

Bartlett, R. G.↗

A Study of the Effects of Relative Humidity on Small Particle Adhesion to Surfaces

Ambient dust ranging in size from less than one micron up to 140 microns was used as test particles. Relative humidities of 33% to 100% were used to condition test surfaces after loading with the test particles. A 20 psi nitrogen blowoff was used as the removal mechanism to test for particle adhesion. Particles were counted before and after blowoff to determine retention characteristics. Particle adhesion increased drastically as relative humidity increased above 50%. The greatest adhesion changes occurred within the first hour of conditioning time. Data are presented for total particle adhesion, for particles 10 microns and larger, and 50 microns and larger.

Whitfield, W. J.↗

Hydrochloric acid aerosol formation by the interaction of hydrogen chloride with humid air

The conditions in which hydrochloric acid aerosol is predicted by the interaction of hydrogen chloride gas with the water vapor in humid air are analyzed. The liquid gas phase equilibrium for the HCL-H2O system is expressed in terms of relative humidity and hydrogen chloride concentration as parts per million, units commonly used in pollution studies. Presented are the concentration (wt %) of HC1 in the aerosol and the concentration of aerosol (ppm) predicted.

Rhein, R. A.↗

Breadboard CO2 and humidity control system

A regenerable CO2 and humidity control system is being developed for potential use on shuttle as an alternate to the baseline lithium hydroxide (LiOH)/condensing heat exchanger system. The system utilizes a sorbent material, designated HS-C, to adsorb CO2 and water vapor from the cabin atmosphere. The material is regenerated by exposing it to space vacuum. A half-size breadboard system, utilizing a flight representative HS-C canister, was designed, built, and performance tested to shuttle requirements for total CO2 and total humidity removal. The use of a new chemical matrix material allowed significant optimization of the system design by packing the HS-C chemical into the core of a heat exchanger which is manifolded to form two separate and distinct beds. Breadboard system performance was proven by parametric testing and simulated mission testing over the full range of shuttle crew sizes and metabolic loadings. Vacuum desorption testing demonstrated considerable savings in previously projected shuttle vacuum duct sizing.

Boehm, A. M.↗

Equations for the determination of humidity from dewpoint and psychrometric data

A general expression based on the Claperon-Clausius differential equation that relates saturation vapor pressure, absolute temperature, and the latent heat of transformation was derived that expresses saturation vapor pressure as a function of absolute temperature. This expression was then used to derive general expressions for vapor pressure, absolute humidity, and relative humidity as functions of either dewpoint and ambient temperature or psychrometric parameters. Constants for all general expressions were then evaluated to give specific expressions in both the international system of units and U.S. customary units for temperatures above and below freezing.

Parish, O. O.↗

CO2 and humidity removal system for extended Shuttle missions - Equilibrium testing and performance analysis

In Shuttle orbiter cabins, lithium hydroxide (LiOH) canisters are currently planned to be used for CO2 adsorption and condensing heat exchangers for humidity control. In this paper a more effective CO2 and humidity removal method is proposed by replacing the LiOH component with HS-C adsorbent (a polyethylenimine coated acrylic ester), thus eliminating the low temperature constraints on the active thermal control system. Since the adsorption of CO2 and H2O are reversible, a double bed configuration operating cyclicly is planned to provide continuous atmospheric control. Apparatus and the experimental procedure to test the adsorption equilibrium are described and some of the indicative results, tabulated by computers, are presented with the help of exponential expressions and differential equations. By using a computer model of the Shuttle HS-C system, performance predictions are made.

Davis, S. H.↗

Effect of ambient temperature and humidity on emissions of an idling gas turbine

The effects of inlet pressure, temperature, and humidity on the oxides of nitrogen produced by an engine operating at takeoff power setting were investigated and numerous correction factors were formulated. The effect of ambient relative humidity on gas turbine idle emissions was ascertained. Experimentally, a nonvitiating combustor rig was employed to simulate changing combustor inlet conditions as generated by changing ambient conditions. Emissions measurements were made at the combustor exit. For carbon monoxide, a reaction kinetic scheme was applied within each zone of the combustor where initial species concentrations reflected not only local combustor characteristics but also changing ambient conditions.

Kauffman, C. W.↗

Flight prototype CO2 and humidity control system

A regenerable CO2 and humidity control system is presently being developed for potential use on shuttle as an alternative to the baseline lithium hydroxide system. The system utilizes a sorbent material (designated HS-C) to adsorb CO2 and the latent heat load from the cabin atmosphere and desorb the CO2 and water vapor overboard when exposed to a space vacuum, thus reducing the overall vehicle heat rejection load. Continuous operation is achieved by utilizing two beds which are alternatively cycled between adsorption and desorption. The HS-C material process was verified. Design concepts for the auxiliary components for the HS-C prototype system were generated. Performance testing verified system effectiveness in controlling CO2 partial pressure and humidity.

Rudy, K. M.↗

Effect of production microclimate on female thermal state with increased temperature and air humidity

The thermal state of women during the effect of high air temperature and relative humidity with a varying degree of physical loads was studied. Parameters for air temperature, relative humidity, and air movement were established. It was established that in women the thermo-regulatory stress occurs at lower air temperatures and with lower physical loads than in men. The accumulation of heat in women was revealed with lower air temperature than in men. It is concluded that to preserve the normal physiological state of the female organism it is necessary to create more favorable microclimate conditions and decrease the physical loads.

Machablishvili, O. G.↗