At least 91 records · Page 5

Ion heating in the PISCES-RF liquid-cooled high-power, steady-state, helicon plasma device

Radio frequency (RF) driven helicon plasma sources are commonly used for their ability to produce high-density argon plasmas ( n > 10 19 m -3 ) at relatively moderate powers (typical RF power < 2 kW). Typical electron temperatures are <10 eV and typical ion temperatures are <0.6 eV. A newly designed helicon antenna assembly (with concentric, double-layered, fully liquid-cooled RF-transparent windows) operates in steady-state at RF powers up to 10 kW. We report on the dependence of argon plasma density, electron temperature and ion temperature on RF power. At 10 kW, ion temperatures >2 eV in argon plasmas are measured with laser induced fluorescence, which is consistent with a simple volume averaged 0D power balance model. 1D Monte Carlo simulations of the neutral density profile for these plasma conditions show strong neutral depletion near the core and predict neutral temperatures well above room temperatures. The plasmas created in this high-power helicon source (when light ions are employed) are ideally suited for fusion divertor plasma-material interaction studies and negative ion production for neutral beams.

Physics↗

RF Design of a High Average Beam-Power SRF Electron Source

There is a significant interest in developing high-average power electron sources, particularly in the area of electron sources integrated with Superconducting Radio Frequency (SRF) systems. For these systems, the electron gun and cathode parts are critical components for stable intensity and high-average powers. In this initial design study, we will present the design of a 9-cell accelerator cavity having a frequency of 1.3 GHz and the corresponding field optimization studies.

43 PARTICLE ACCELERATORS↗

Ultra-High Gradient Compact S-Band Linac for Laboratory and Industrial Applications

There is growing demand from the industrial and research communities for high gradient, compact RF accelerating structures. The commonly used S-band SLAC-type structure has an operating gradient of only about 20 MV/m; while much higher operating gradients (up to 70 MV/m) have been recently achieved in X-band, as a consequence of the substantial efforts by the Next Linear Collider (NLC) collaboration to push the performance envelope of RF structures towards higher accelerating gradients. Currently however, high power X-band RF sources are not readily available for industrial applications. Therefore, RadiaBeam Technologies is developing a short, standing wave S-band structure which uses frequency scaled NLC design concepts to achieve up to a 50 MV/m operating gradient at 2856 MHz. The design and prototype commissioning plans are presented.

43 PARTICLE ACCELERATORS↗

Design and Study of Inductively Coupled Plasma Chamber Components Using the SupRISE Test Device at DIII-D

The DIII-D National Fusion Facility aims to increase the auxiliary heating power for the tokamak by upgrading the Neutral Beam Injection (NBI) system. In collaboration with North Carolina State University, the conventional ‘arc and filament’ NBI ion sources will be converted to inductively coupled plasma (ICP) sources which utilize radio frequency (RF) coupling to maximize reliability for high power operation. In support of this initiative, a full scale test device (SupRISE, Superior Radiofrequency Ion Source Experiment) is currently under construction at the DIII-D Facility. In preparation for the construction of a full scale prototype that can be installed on the DIII-D NBI system, experiments on SupRISE will be conducted to determine the optimal RF frequency for high power coupling, Faraday shield slit configuration, and ICP chamber length. SupRISE is comprised of an approximately 30 x 70 cm quartz dielectric vessel with an internal Faraday shield enclosed in a secondary vacuum chamber to ensure structural stability of the dielectric. Actively cooled front and back plates are designed to reduce the thermal stresses on the plasma facing components and mate with the existing accelerator used by the NBI system at DIII-D. 50 kW of RF power will be coupled to the plasma through the quartz over a variable frequency range of 4-8 MHz to sustain a plasma density of ∼ 10 18 m −3 for a 10 s ON, 210 s OFF duty cycle. Various modelling efforts have been employed to simulate the thermal and stress profiles over the primary components of the SupRISE device as well as the inductance behavior of the RF antenna. These simulation results and the final design for SupRISE will be presented. An additional reduced-scale predecessor ICP source (called RISE) has been used to develop a predictive match model that will be applied to frequency optimization studies on SupRISE. Furthermore, the outcomes of this research and complementary efforts at North Carolina State University are essential for the incorporation of ICP NBI positive ion sources at the DIII-D facility.

DIII-D↗

Overview of High Power Vacuum Dry RF Load Designs

A specific feature of RF linacs based on the pulsed traveling wave (TW) mode of operation is that only a portion of the RF energy is used for the beam acceleration. The residual RF energy has to be terminated into an RF load. Higher accelerating gradients require higher RF sources and RF loads, which can stably terminate the residual RF power. RF feeders (from the RF source though the accelerating section to the load) are vacuumed to transmit multi-megawatt high power RF. This overview will outline vacuumed RF loads only. A common method to terminate multi-MW RF power is to use circulated water (or other liquid) as an absorbing medium. A solid dielectric interface (a high quality ceramic) is required to separate vacuum and liquid RF absorber mediums. Using such RF load approaches in TW linacs is troubling because there is a fragile ceramic window barrier and a failure could become catastrophic for linac vacuum and RF systems. Traditional loads comprising of a ceramic disk have limited peak and average power handling capability and are therefore not suitable for high gradient TW linacs. This overview will focus on ''vacuum dry'' or ''all-metal'' loads that do not employ any dielectric interface between vacuum and absorber. The first prototype is an original design of RF loads for the Stanford Two-Mile Accelerator.

43 PARTICLE ACCELERATORS↗

Design Features and Initial RF Performance of a Gradient Hardened 17 GHz TW Linac Structure

To avoid surface erosion damage and to assist in studying RF breakdown thresholds in 17 GHz TW linac structures, a gradient hardened structure has been fabricated with high temperature brazed and machined stainless steel surfaces located in the peak E-field region of the beam apertures and the peak H-field regions of the input coupler cavity. The microwave design parameters and physical dimensions of this 22 cavity, 120 degree phase advance structure were chosen to allow the high gradient performance to be compared against a similar design all-copper structure that has been tested in a dual ring, power recirculating amplifier system. The final design parameters of the gradient hardened structure are discussed; the influence of stainless steel RF losses on the power buildup of the resonant ring and on the structure gradient distribution are described; waveforms are shown of the unique ability of the power amplifier to rapidly quench RF breakdown discharges in the linac structure by automatically sensing and redirecting the RF source power to a matched load; and preliminary test results during high power RF processing of the gradient hardened linac structure are presented.

43 PARTICLE ACCELERATORS↗

Erosion of high-Z refractory coatings for helicon plasma source window

Proto-MPEX (Materials Plasma Exposure eXperiment), a linear plasma device (LPD), using a high power radio frequency (RF) (⩾100 kW, 13.56 MHz) helicon plasma source, has suffered RF sheath-induced window erosion. The sputtered impurities from the window surface transport toward the downstream target affecting plasma-material interaction studies. The rectified sheath voltage formed was high enough to cause window erosion by light ions due to its low-Z components (e.g. Si 3 N 4 and AlN). Hence, we are proposing impurity mitigation strategies, which involve the application of a Faraday screen to lower the rectified sheath voltage and the application of high-Z refractory coatings on the existing window plasma-facing surface. In this work, we report the erosion of two different coatings, i.e., tantalum oxide (Ta 2 O 5 ) and hafnium oxide (HfO 2 ) on a silicon nitride (Si 3 N 4 ) window material under conditions of low-energy deuterium (D) ion impact, well below the Ta 2 O 5 sputtering energy threshold (i.e. 250 eV). The test samples were RF-biased and exposed to a high D-ion fluence (∼10 26 m −2 ) in Plasma Interaction with Surface Component Experimental Station (PISCES-A) LPD. The experimentally measured sputtering yields of the high-Z refractory coatings below the sputtering energy threshold of Ta 2 O 5 indicate an increased erosion due to the plasma impurities, especially due to oxygen. Improving the vacuum level could reduce the oxygen impurities and increase the lifespan of the coated helicon window for plasma operation. Post-surface analysis indicates no preferential erosion of oxygen or enrichment of the high-Z surface component. This is likely due to an effective energy transfer from the impurity ion for sputtering of the high-Z component in the coating. With the reduced rectified sheath voltage at the window surface and improved vacuum conditions, the proposed high-Z refractory coatings offer a promising solution for reducing window erosion in future MPEX plasma operations at ORNL.

RF bias↗

Time evolution of endpoint energy of Bremsstrahlung spectra and ion production from an electron cyclotron resonance ion source

Electron cyclotron resonance ion sources (ECRIS) are used to produce high charge state heavy ion beams for the use of nuclear and materials science, for instance. The most powerful ECR ion sources today are superconducting. One of the problems with superconducting ECR ion sources is the use of high radio frequency (RF) power which results in bremsstrahlung radiation adding an extra heat load to the cryostat. In order to understand the electron heating process and timescales in the ECR plasma, time evolution measurement of ECR bremsstrahlung was carried out. In the measurements JYFL 14 GHz ECRIS was operated in a pulsed mode and bremsstrahlung data from several hundred RF pulses was recorded. Time evolution of ion production was also studied and compared to one of the electron heating theories. To analyze the measurement data at C++ program was developed. Endpoint energies of the bremsstrahlung spectra as a function of axial magnetic field strength, pressure and RF power are presented and ion production timescales obtained from the measurements are compared to bremsstrahlung emission timescales and one of the stochastic heating theories.

43 PARTICLE ACCELERATORS↗

JLAMP Proposed 4th Generation VUV/Soft X-ray Light Source

Invited Talk compiled for Sixth CW and High Average Power RF Workshop - Jefferson Lab (JLab) is proposing JLAMP (JLab AMPlifier), a 4th generation light source covering the range 10?100 eV in the fundamental mode with harmonics stretching towards the oxygen k-edge. The scientific purpose is to study ultrafast dynamics in complex systems as a pathway to the understanding and creation of novel materials and devices. The machine will be based on an energy upgrade to an existing energy-recovering linear accelerator at JLab, made possible by advances in superconducting accelerator technology. Specifically, accelerating gradients of 20 MV/m and electron-beam recirculation will allow electron-beam energies of >600 MeV to be achieved at repetition rates up to 4.68 MHz with continuous wave RF. The RF systems for the machine will operate at 1497 MHz, 748.5 MHz and 187.125 MHz. The average brightness will substantially exceed existing light sources in this device's photon energy range, and in addition, multiple photon sources will be made available for pump-probe dynamical studies. The system will be capable of operating as a seeded amplifier for precise pulse length and bandwidth control or as an oscillator at higher average brightness. An overview of the accelerator with specific details relating to the RF systems will be presented.

Powers, Thomas↗

Results of the SLAC LCLS Gun High-Power RF Tests

The beam quality and operational requirements for the Linac Coherent Light Source (LCLS) currently being constructed at SLAC are exceptional, requiring the design of a new RF photocathode gun for the electron source. Based on operational experience at SLAC's GTF and SDL and ATF at BNL as well as other laboratories, the 1.6cell s-band (2856MHz) gun was chosen to be the best electron source for the LCLS, however a significant redesign was necessary to achieve the challenging parameters. Detailed 3-D analysis and design was used to produce near-perfect rotationally symmetric rf fields to achieve the emittance requirement. In addition, the thermo-mechanical design allows the gun to operate at 120Hz and a 140MV/m cathode field, or to an average power dissipation of 4kW. Both average and pulsed heating issues are addressed in the LCLS gun design. The first LCLS gun is now fabricated and has been operated with high-power RF. The results of these high-power tests are presented and discussed.

43 PARTICLE ACCELERATORS↗

High efficiency, low cost, RF sources for accelerators and colliders

Accelerators for High Energy Physics (HEP) are large users of energy, much of it in the form of radiofrequency (RF) power to accelerate particles to very high energies. Proposed HEP projects will require even larger amounts of RF energy. Increasing concerns of the cost and availability of energy will require the HEP community to use energy as efficiently as possible. Successful transfer of HEP technology to the public and private sectors will be most effective if it is highly efficient. Historically, the HEP community has utilized available RF power sources, mainly in the form of vacuum tube technology, much of which was developed during the cold war or is otherwised used in the private sector. The private sector is moving to solid-state RF sources which do not exhibit the electrical efficiency that is needed for future HEP projects. Here we summarize the state of the development of a number of RF sources that promise efficiencies of 80% and above. We also outline future efforts that are needed to fully realize the potential of these sources.

43 PARTICLE ACCELERATORS↗

Efficient continuous-wave normal conducting accelerator for industrial applications

A normal conducting, high power, high efficiency copper linear accelerator prototype is being developed for industrial applications. The system will be powered by low-cost high-efficiency magnetron RF sources and will use a gridded thermionic cathode electron gun. Leveraging the significant accelerator expertise at JLab and industry partners, these technologies will be combined to deliver high-power (>100 kW) electron beams with energies of 1 MeV or higher that are cost-effective to produce and operate. The design is modular such that energy and power can be increased by adding additional sections as required. The status of the design, prototype fabrication and plans for a beam demonstration at JLab are described.

Accelerator Physics↗

Plasma physics and related challenges of millimeter-wave-to-terahertz and high power microwave generation

Homeland security and military defense technology considerations have stimulated intense interest in mobile, high power sources of millimeter-wave (mmw) to terahertz (THz) regime electromagnetic radiation, from 0.1 to 10 THz. While vacuum electronic sources are a natural choice for high power, the challenges have yet to be completely met for applications including noninvasive sensing of concealed weapons and dangerous agents, high-data-rate communications, high resolution radar, next generation acceleration drivers, and analysis of fluids and condensed matter. The compact size requirements for many of these high frequency sources require miniscule, microfabricated slow wave circuits. This necessitates electron beams with tiny transverse dimensions and potentially very high current densities for adequate gain. Thus, an emerging family of microfabricated, vacuum electronic devices share many of the same plasma physics challenges that are currently confronting 'classic' high power microwave (HPM) generators including long-life bright electron beam sources, intense beam transport, parasitic mode excitation, energetic electron interaction with surfaces, and rf air breakdown at output windows. The contemporary plasma physics and other related issues of compact, high power mmw-to-THz sources are compared and contrasted to those of HPM generation, and future research challenges and opportunities are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Average Current Bunched Electron Source for RF Accelerators

High-average current high-quality electron beams are imperative for high-power RF accelerators used in various energy and environmental applications in industry, medicine, and national security as well as for advanced existing and future accelerator systems such as PIP II, particle colliders (eRHIC BNL) for cooling high-energy proton, ion, and hadron beams, storage rings, wakefield accelerators (AWA), and energy recovery linacs. The most common current approach to generate high-peak current high-brightness short electron bunches uses photoemission excited by intense laser radiation. However, to avoid overheating photocathodes are operated at a subharmonic of the linac frequency that in turn restricts the average beam current. There are also limitations in the electron-beam average current due to the average power available from drive lasers. On the other hand, the state of the art thermionic sources that produce high average current electron beams do not have yet good emission gating methods to realize sufficiently short and good quality electron bunches. We develop a robust thermionic electron source (e-source) of >1 A average current with advanced gating of the emission at the linac-frequency and its 3rd harmonic. Central to the approach is a novel scheme for energy efficient feeding of the 3rd-harmonic power in the RF gap. The cathode is attached to the gun cavity through this small emission-gating gap in which the RF modes are excited. The use of thermionic emission allows for the desired high-average current CW electron beams. Adding the 3rd emission gating harmonic shortens the electron bunches and by this means lessens impact of the RF curvature on the beam quality resulting in the smaller energy spread and bunch emittances. Such high current electron beam is suitable for injection into high-power normal- or superconducting linacs in CW mode at a high repetition rate of the linac frequency. In Phase I, we performed modeling and beam dynamics, parametric, and optimization studies. A >1A average current e-source with 200,000hrs lifetime expectancy has been demonstrated in the simulations. We have developed baseline design of the e-source and its components. It is anticipated that the e-source will be in demand for normal- and superconducting particle accelerators and will benefit many commercial and energy and environmental applications such as treating waste and potable water, sludge, stack gases, and medical waste as well as X-ray sources for medicine, sterilization, materials processing, geology, and non-intrusive imaging.

43 PARTICLE ACCELERATORS↗

H{sup -} beam extraction from a cesium seeded field effect transistor based radio frequency negative hydrogen ion source

H{sup -} beam was successfully extracted from a cesium seeded ion source operated using a field effect transistor inverter power supply as a radio frequency (RF) wave source. High density hydrogen plasma more than 10{sup 19} m{sup -3} was obtained using an external type antenna with RF frequency of lower than 0.5 MHz. The source was isolated by an isolation transformer and H{sup -} ion beam was extracted from a single aperture. Acceleration current and extraction current increased with the increase of extraction voltage. Addition of a small amount of cesium vapor into the source enhanced the currents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrooptic modulation methods for high sensitivity tunable diode laser spectroscopy

A CdTe phase modulator and low power RF sources have been used with Pb-salt tunable diode lasers operating near 8 microns to generate optical sidebands for high sensitivity absorption spectroscopy. Sweep averaged, first-derivative sample spectra of CH4 were acquired by wideband phase sensitive detection of the electrooptically (EO) generated carrier-sideband beat signal. EO generated beat signals were also used to frequency lock the TDL to spectral lines. This eliminates low frequency diode jitter, and avoids the excess laser linewidth broadening that accompanies TDL current modulation frequency locking methods.

Glenar, David A.↗

Basic plasma physics experiments and modeling of space phenomena on a large inductively coupled magnetoplasma device

Large KROT device is developed for modeling of space plasma physics phenomena and studies of interaction of super-strong electromagnetic radiation with plasmas. The core of the facility is pulsed RF plasma source with MW power level. Well repeated and highly uniform plasma, magnetized or not, can be produced in a volume of several tens of cubic meters. An overview of the facility operational parameters is presented along with the results of recent experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗