Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HgTe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

75 records · Page 5

Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anticoincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) soft x-ray spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS had a square array of 36 x-ray calorimeters at the focal plane. These calorimeters consisted of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector was located behind the calorimeter array and served to reject events due to cosmic rays. We will briefly describe this anticoincidence detector and its performance.

Kilbourne, Caroline A.↗

Extended Line Spread Function of TES Microcalorimeters with Au/Bi Absorbers

Microcalorimeters have the potential to provide line shapes well-described by a single Gaussian broadening term of few-eV width. This attribute makes the detectors especially well suited for x-ray astrophysics observations; however, low-level non-Gaussian broadening terms are expected and must be characterized. These terms depend on the composition of the x-ray absorber, the detailed x-ray absorption physics, the device thermalization processes, and the incident x-ray energy. Here we present the first measurements targeted at understanding the extended line-spread function (LSF) of x-ray microcalorimeter pixels under development for the X-ray Integral Field Unit (XIFU) on the Athena X-ray Observatory. These pixels are comprised of Mo/Au transition-edge sensors (TESs) with overhanging electroplated Au/Bi absorbers. We measured the line shapes using monochromatic x-ray sources with < 1 eV width at several x-ray energies (0.85, 0.93, 1.25, 1.5, 5.4, and 8.0 keV) across the instrument bandpass (0.3-12 keV) and modeled the line profiles. These results are compared to the extended LSF of the Hitomi microcalorimeter pixels that used HgTe absorbers.

Superconducting devices↗

Shaping the Infrared luminescence of Colloidal Nanocrystals Using a Dielectric Microcavity

As they have gained maturity, colloidal nanocrystals (NCs) have also expand the spectral range over of which they could be used for photonic and optoelectronic applications. In particular, the infrared use of NCs has become of utmost interest to develop cost-effective alternatives to current technologies. It is then critical not to let the material dictate the light–matter interaction, which is why the coupling of NCs to photonic cavities has been proposed. For infrared NCs, this approach has first been devoted to the control of absorption with in mind the increase of the signal magnitude for detectors. A Lot of efforts have been focused on the use of metallic metasurfaces. However, these generate significant optical losses and yield low quality factor. Here, this study rather focus on the coupling of infrared NCs to a dielectric mirror cavity. HgTe/CdS core-shell NCs are used and integrated into a cavity made of aperiodic dielectric mirrors. The effect of the substrate is systematically study on spectral linewidth, carrier dynamic, and emission directivity. The cavity is shown to narrow the PL by a factor 10, while focusing the emission over a 12° angle. Monitoring the power dependence of the emission, this study shows that the cavity leads to 250 K increase in the effective electronic temperature.

36 MATERIALS SCIENCE↗