PREDICTIONS OF FIELD FLUCTUATIONS IN HETEROGENEOUS MATERIALS
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract not provided.
Exhibit describes development of diagnostics to non-destructively determine defects in crystal structures, voids, and impurities in polycrystalline and compound samples.
Methods are provided for generating a crystalline material. The methods comprise depositing a textured thin film in a growth seed area, wherein the textured thin film has a preferential crystallographic axis; providing a growth channel extending from the growth seed area, the growth channel permitting guided lateral growth; and growing a crystalline material in the growth channel along a direction that is substantially perpendicular to the preferential crystallographic axis of the textured thin film. A preferred crystalline material is gallium nitride, and preferred textured thin films are aluminum nitride and titanium nitride.
Exhibit describes project to develop two complementary nondestructive characterization techniques that cover the meso-scale and the micro-scale in order to understand the stress and temperature evolution upon shock loading.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Presented by NETL at MS&T 2019, 09/19
No abstract prepared.
The complex physical phenomenon of shock wave interaction with material heterogeneities has significant importance and nevertheless remains little understood. In many materials, the observed macroscale response to shock loading is governed by characteristics of the microstructure. Yet the majority of computational studies aimed at predicting phenomena affected by these processes, such as initiation and propagation of detonation waves in explosives, or shock propagation in geological materials, employ continuum material and reactive burn model treatment. In an effort to highlight the grain-scale processes that underlie the observable effects in an energetic system, a grain-scale model for hexanitrostilbene (HNS) has been developed. Measured microstructures were used to produce synthetic computational representations of the pore structure, and a density functional theory molecular dynamics (DFT-MD) derived equation of state (EOS) was used for the fully dense HNS matrix. The explicit inclusion of microstructure along with a fully-dense EOS resulted in close agreement with historical shock compression experiments. More recent experiments on dynamic reaction threshold were also reproduced by inclusion of a global kinetics model. The complete model was shown to reproduce accurately the expected response of this heterogeneous material to shock loading. Mesoscale simulations were shown to provide clear insight into the nature of threshold behavior, and are a way to understand complex physical phenomena.
Patient-specific quality assurance (QA) is a major component of the Intensity Modulated Radiation Therapy (IMRT) clinical process. The objective of this often time-intensive measurement process is to verify that the prescribed dose is accurately delivered to the target volume while sparing surrounding healthy tissue. The IMRT dose distributions can be measured using a wide variety of techniques and measurement devices including film (radiographic and radiochromic), ion chamber arrays, diode arrays, and Electronic Portal Imaging Devices (EPIDs). Of all the available modalities, film is one of the most versatile and most frequently utilized measurement systems. In rotation delivery techniques (such as volume modulated arc therapy and helical tomotherapy), composite dose distributions are obtained by irradiating a test phantom containing dosimeter(s). When film is utilized as the dosimeter, it can be placed in coronal, sagittal, or transverse planes inside the phantom. Because the film is irradiated using the rotational delivery sequence used to treat the patient, the dose given to specific anatomical structures (such as the parotids, spinal cord, bladder, rectum etc...) can be evaluated. Thomas et al (Med Phys 32: 3793-3800) recently reported the results of IMRT verifications for ten patients planned and treated with helical tomotherapy. This study reported that nearly 92% of the film pixels within the analyzed region of interest were within a gamma criterion of 2 mm and 2%. Like most tomotherapy users, Thomas et al used a test phantom made of homogeneous water equivalent material. Heterogeneous phantoms that simulate the different tissue densities in the human body do exist, but are infrequently used for patient-specific IMRT QA. The potential advantage of using heterogeneous phantoms is that the measured dose distributions will more adequately reflect the clinical dose distributions in the patients. The use of homogenous phantoms during IMRT quality assurance can potentially mask errors that arise from limitations in the treatment planning system's modeling of density corrections. The purpose of this study was to evaluate the dosimetric accuracy of a helical tomotherapy system using an anthropomorphic RANDO phantom (The Phantom Laboratory, Salem, NY) for patient-specific QA. The results of this study will allow a benchmark to be established for dosimetric accuracy in heterogeneous materials. Performing patient-specific QA is an integral part of the IMRT patient treatment process. Test phantoms are typically homogeneous, and do test the treatment planning systems ability to account for heterogeneity corrections. In this study, an anthropomorphic RANDO phantom was used to evaluate the doses calculated by a helical tomotherapy system. The dosimetric agreement between calculated and measured was worse than published results in homogenous phantoms, especially for target volumes located in the lung. Further investigation will be needed to determine if these errors are due to film response at heterogeneous tissue interfaces or from actual dose calculation errors. (authors)
Full-field, quantitative visualization techniques, such as digital image correlation (DIC), have unlocked vast opportunities for experimental mechanics. However, DIC has traditionally been a surface measurement technique, and has not been extended to perform measurements on the interior of specimens for dynamic, full-scale laboratory experiments. This limitation restricts the scope of physics which can be investigated through DIC measurements, especially in the context of heterogeneous materials. The focus of this study is to develop a method for performing internal DIC measurements in dynamic experiments. The aim is to demonstrate its feasibility and accuracy across a range of stresses (up to 650 MPa), strain rates (10 3 - 10 6 s -1 ), and high-strain rate loading conditions (e.g., ramped and shock wave loading). Internal DIC is developed based on the concept of applying a speckle pattern at an inner-plane of a transparent specimen. The high-speed imaging configuration is coupled to the traditional dynamic experimental setups, and is focused on the internal speckle pattern. During the experiment, while the sample deforms dynamically, in-plane, two-dimensional deformations are measured via correlation of the internal speckle pattern. In this study, the viability and accuracy of the internal DIC technique is demonstrated for split-Hopkinson (Kolsky) pressure bar (SHPB) and plate impact experiments. The internal DIC experimental technique is successfully demonstrated in both the SHPB and plate impact experiments. In the SHPB setting, the accuracy of the technique is excellent throughout the deformation regime, with measurement noise of approximately 0.2% strain. In the case of plate impact experiments, the technique performs well, with error and measurement noise of 1% strain. The internal DIC technique has been developed and demonstrated to work well for full-scale dynamic high-strain rate and shock laboratory experiments, and the accuracy is quantified. Here, the technique can aid in investigating the physics and mechanics of the dynamic behavior of materials, including local deformation fields around dynamically loaded material heterogeneities.
Explore the source record for details and available documents.
We present an approach and relevant models for predicting the probabilistic shoc-to-detonation transition (SDT) behavior and Pop plot (PP) of heterogeneous energetic materials (HEM) via mesoscopic microstructure-explicit (ME) and void explicit (VE) simulations at the millimeter (mm) sample size scale. Although the framework here is general, the particular material considered in this paper is pressed Octahydro-1,3,5,7-tetranitro-1,2,3,5-tetrazocine (HMX). To systematically delineate the effects of material heterogeneities, four material cases are considered. These cases are homogeneous material, material with granular microstructure but no voids, homogeneous material with voids, and material with both granular microstructure and voids. Statistically equivalent microstructure sample sets (SEMSS) are generated and used. Eulerian hydrocode simulations explicitly resolve the material heterogeneities, voids, and the coupled mechanical-thermal-chemical processes. In particular, it is found that both microstructure and voids strongly influence the SDT behavior and PP. The effects of different combinations of microstructure heterogeneity and voids on the SDT process and PP are quantified and rank-ordered. The overall framework uses the Mie–Grüneisen equation of state and a history variable reactive burn model (HVRB). A novel probabilistic representation for quantifying the PP is developed, allowing the calculation of (1) the probability of observing SDT at a given combination of shock pressure and run distance, (2) the run-distance to detonation under a given combination of shock pressure and prescribed probability, and (3) the shock pressure required for achieving SDT at a given run distance with a prescribed probability. The results are in agreement with general trends in experimental data in the literature.
Explore the source record for details and available documents.