Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Review of the potential and challenges of MOF-based adsorption heat pumps for sustainable cooling and heating in the buildings

Heat pumps are regarded as the most suitable means to meet the future demand of heating and cooling in the building, as they require small input of electrical energy and output high thermal energy. Vapor compression heat pump (VCHP) and transcritical-CO 2 heat pump are the two major heat pump technologies currently dominating the market. However, VCHP system suffers from its fugitive emission of hydrofluorocarbon (HFC) refrigerants, and transcritical-CO 2 system requires high operating pressure (typically 9–13 MPa). For low-to-medium temperature heating and cooling applications thermally driven adsorption heat pump (AHP) provides a better alternative to VCHP and transcritical-CO 2 system as AHP uses natural refrigerants and operates at a much lower pressure. But currently available AHP technology has the limitation of low coefficient of performance (COP). Advances in synthesizing metal-organic frameworks (MOF) with high gas adsorption capacity have created an opportunity to address the problem of low COP of current AHP technology. Here, this article reviews the progress made in the past decade in utilizing MOF and conventional adsorbents with different working fluids in AHP technology and compares their performance. The article also summarizes the key challenges for the MOF-based AHP technology and provides the authors’ perspective to address these challenges.

30 DIRECT ENERGY CONVERSION↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiative heat transfer in FLiBe molten salt participating medium in a vertical heated tube under forced and mixed convection laminar flows

The contribution of radiative heat transfer (RHT) to convective heat transfer in a heated vertical pipe with laminar flow and constant wall temperature, for FLiBe molten salt, is investigated computationally. The combined effects of conduction in the fluid, forced convection, buoyancy, temperature-dependent physical properties, and thermal radiation are investigated. The P1 approximation is employed in the discretization of the Radiative Transfer Equation (RTE). The COMSOL Multiphysics software is used to generate the numerical solutions. The theoretical analysis developed here demonstrates that only for intermediate values of the optical thickness, i.e. τ D ~ O 1 , the participating media effects are expected to be important. This analysis is confirmed computationally and a value of τ D ≈ 4 is shown to lead to the highest increase in overall heat transfer behavior. Under forced convection, the Nusselt ratio N u total / N u no - rad reaches a peak value of 1.76 at τ D = 4 and z/D = 200 , and is less than 1.1 for τ D < 0 . 1 and τ D > 60 . Under aiding-flow mixed convection, N u total / N u no - rad reaches a peak of 1.34 at τ D = 4 . 2 and is less than 1.1 for τ D < 0 . 4 and τ D > 36 . Under opposing-flow mixed convection, Nu total / Nu no - rad reaches a peak of 1.81 at τ D = 4 . 2 and is less than 1.1 for τ D < 0 . 2 and τ D > 50 . RHT effects on the overall heat transfer are most pronounced in opposing mixed convection, where N u total / N u no - rad is 2.26 observed at z/D = 50 . The sensitivity to wall emissivity is evaluated; in forced convection, the peak N u total / N u no - rad is 1.66 at ε = 0 (reflective wall) and 2.04 at ε = 1 (absorptive wall). Finally, the sensitivity to pipe diameter is also discussed. Overall, for a vertical heated tube, radiative heat transfer effects lead to enhancement of heat transfer by as high as a factor of two, and they depend on the optical thickness of the flow, mixed convection environment ( Gr / R e 2 and direction of flow relative to the gravitational force), surface emissivity, and entrance effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impacts of Anisotropic Porosity on Heat Transfer and Off-Gassing during Biomass Pyrolysis

The pore structure of biogenic materials imbues the ability to deliver water and nutrients through a plant from root to leaf. This anisotropic pore granularity can also play a significant role in processes such as biomass pyrolysis that are used to convert these materials into useful products like heat, fuel, and chemicals. Evolutions in modeling of biomass pyrolysis as well as imaging of pore structures allow for further insights into the concerted physics of phase change-induced off-gassing, heat transfer, and chemical reactions. In this work, we report a biomass single particle model which incorporates these physics to explore the impact of implementing anisotropic permeability and diffusivity on the conversion time and yields predicted for pyrolysis of oak and pine particles. Simulation results showed that anisotropic permeability impacts predicted conversion time more than 2 times when the Biot number is above 0.1 and pyrolysis numbers (Py 1 , Py 2 ) are less than 20. Pore structure significantly impacts predicted pyrolytic conversion time (>8 times) when the Biot number is above 1 and the pyrolysis number is below 1, i.e., the “conduction controlled” regime. Therefore, these nondimensional numbers reflect that when internal heat conduction limits pyrolysis performance, internal pyrolysis off-gassing further retards effective heat transfer rates as a closely coupled phenomenon. Overall, this study highlights physically meaningful opportunities to improve particle-scale pyrolysis modeling and experimental validation relevant to a variety of feedstock identities and preparations, guiding the future design of pyrolyzers for efficient biomass conversion.

09 BIOMASS FUELS↗

Analysing the effects of heating and gas puffing in Proto-MPEX helicon and auxiliary heated plasmas

The Material Plasma Exposure Experiment (MPEX) is being constructed at Oak Ridge National Laboratory to investigate critical fusion reactor issues, such as plasma–material interactions (PMIs) under reactor-relevant conditions and time scales. The linear device Proto-MPEX was used as a test bed to address anticipated research and development issues associated with heating scenarios and establish the physics basis for MPEX. The SOLPS-ITER code suite has been applied to understand plasma and neutral transport in Proto-MPEX and to increase confidence in predictive simulations for MPEX. Coupling between COMSOL and SOLPS is performed to implement a 2D electron heating profile of the helicon source. The simulations show reasonable agreement with the experimental data for plasma with helicon and auxiliary electron cyclotron heating (ECH). Both Bohm and constant diffusion (D$_\perp$: 0.5 m 2 s –1 and $\chi_\perp$: 1 m 2 s –1 ) simulations show similar levels of agreement with respect to the sparse experimental data available, assuming a few per cent impurity concentration. ECH significantly increases the target electron temperature, however, the target electron density is reduced compared to helicon-only heated plasmas due to an increase in flow velocity and radial losses. The simulations show that further increasing the ECH power results in an increase in the target electron density due to increased recycling flux and ionization. The results indicate that ECH significantly enhances the target heat flux, with ECH power of 50 kW increasing the target heat flux from 0.4 to 17 MW m –2 . It is found that a small amount of gas puffing (GP) near the target plate can further increase the target heat fluxes at the higher ECH power cases, but the target heat flux is reduced at higher GP conditions due to a significant reduction in electron temperature via radiation. ECH and GP scenarios can generate a higher target flux, facilitating improved PMI studies with more reactor-relevant plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A software package for plasma facing component analysis and design: the Heat flux Engineering Analysis Toolkit (HEAT)

The engineering limits of plasma facing components (PFCs) constrain the allowable operational space of tokamaks. Poorly managed heat fluxes that push the PFCs beyond their limits not only degrade core plasma performance via elevated impurities, but can also result in PFC failure due to thermal stresses or melting. Simple axisymmetric assumptions fail to capture the complex interaction between 3D PFC geometry and 2D or 3D plasmas. This results in fusion systems that must either operate with increased risk or reduce PFC loads, potentially through lower core plasma performance, to maintain a nominal safety factor. High precision 3D heat flux predictions are necessary to accurately ascertain the state of a PFC given the evolution of the magnetic equilibrium. A new code, the Heat flux Engineering Analysis Toolkit (HEAT), has been developed to provide high precision 3D predictions and analysis for PFCs. HEAT couples many otherwise disparate computational tools together into a single open source python package. Magnetic equilibrium, engineering CAD, finite volume solvers, scrape off layer plasma physics, visualization, high performace computing, and more, are connected in a single web-based user interface. Linux users may use HEAT without any software prerequisites via an appImage. This manuscript introduces HEAT, discusses the software architecture, presents first HEAT results, and outlines physics modules in development.

divertor physics↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Local heat transfer measurement in a volumetrically heated TPMS lattice using distributed optical fiber thermal sensing

As additive manufacturing continues to reduce design constraints on heat exchange geometries, methods for high-fidelity local heat transfer measurements in nonconventional channel geometries are critical to their continued development. This study presents a novel method for measuring local heat transfer performance in volumetrically heated lattices using a distributed optical fiber temperature sensor. A diamond-type triply periodic minimal surface (TPMS) lattice, 3D-printed from a conductive polymer, was Joule heated while it was convectively cooled with air. Temperature measurements were taken at the solid–fluid interface across 14 internal locations using a single optical fiber over the Reynolds number range 800–2750. The TPMS lattice achieved up to 312% higher heat transfer coefficients compared to developing flow in a straight tube. A Nusselt number correlation was developed for the diamond TPMS, which showed good agreement with data collected for comparable geometries available in literature. In conclusion, this study presents a robust and new method for experimental measurement of the heat transfer coefficient in complex geometries and helps to understand and quantify the exceptional performance of TPMS heat transfer geometries.

TPMS↗

Numerical simulations of membrane distillation systems with actively heated membranes

Membrane distillation (MD) is a thermal desalination process that is gaining attention for treating hypersaline brines. One recent approach uses composite membranes with a thermally conductive layer that delivers heat to the membrane–feed interface, where it drives evaporation. Though this increases single-pass recovery, it comes with the challenge of promoting lateral heat conduction through the thin membrane. Herein, we develop a 3D, computational fluid dynamics (CFD) model that simulates conjugate heat, mass, and momentum transport in the feed channel and composite membrane. We then use the CFD to verify a simpler numerical model that approximates the feed velocity field analytically. We validate the numerical model experimentally, and use it to investigate the impacts of the conductive layer thickness, feed channel geometry, and operating conditions on temperature and concentration polarization, permeate production, and specific energy consumption. Overall, we find that lateral heating increases permeate production at the expense of increased concentration polarization. In extreme cases, the concentration increases more than four-fold along the membrane surface. Furthermore, we show however, that the feed flow rate and conductive layer thickness can be tailored to mitigate concentration polarization, for only a small reduction in permeate production.

42 ENGINEERING↗

Two interacting ethylene response factors regulate heat stress response

Abstract The ethylene response factor (ERF) transcription factors are integral components of environmental stress signaling cascades, regulating a wide variety of downstream genes related to stress responses and plant development. However, the mechanisms by which ERF genes regulate the heat stress response are not well understood. Here, we uncover the positive role of ethylene signaling, ERF95 and ERF97 in basal thermotolerance of Arabidopsis thaliana. We demonstrate that ethylene signaling-defective mutants exhibit compromised basal thermotolerance, whereas plants with constitutively activated ethylene response show enhanced basal thermotolerance. EIN3 physically binds to the promoters of ERF95 and ERF97. Ectopic constitutive expression of ERF95 or ERF97 increases the basal thermotolerance of plants. In contrast, erf95 erf96 erf97 erf98 quadruple mutants exhibit decreased basal thermotolerance. ERF95 and ERF97 genetically function downstream of EIN3. ERF95 can physically interact with ERF97, and this interaction is heat inducible. ERF95 and ERF97 regulate a common set of target genes, including known heat-responsive genes and directly bind to the promoter of HSFA2. Thus, our study reveals that the EIN3-ERF95/ERF97-HSFA2 transcriptional cascade may play an important role in the heat stress response, thereby establishing a connection between ethylene and its downstream regulation in basal thermotolerance of plants.

Biochemistry & Molecular Biology↗

Vertical Structure of Radiative Heating Rates of the MJO during DYNAMO

The vertical structure of radiative heating rates over the region of the tropi-cal Indian Ocean associated with the MJO during the DYNAMO/ARM MJO Investigation Experiment is presented. The mean and variability of heating rates during active, suppressed, and disturbed phases are determined from the Paci?c Northwest National Laboratory combined remote sensing retrieval (CombRet) from Gan Island, Maldives (0.69? S, 73.15? E). TOA and surface ?uxes from the CombRet product are compared with collocated three-hourly CERES SYN1deg Ed4A satellite retrievals. The ?uxes are correlated in time with correlation coef?cients around 0.9, yet CombRet time-mean OLR is 15 W m-2 larger. Previous work has suggested that CombRet under-samples high clouds, due to attenuation by low-level clouds and reduced instrument sensitivity with altitude. However, mean OLR differs between CombRet and CERES for all values of OLR, not just the lowest values corresponding to widespread high clouds. The discrepancy peaks for mid-range OLR, sugges-tive of precipitating, towering cumulus convective clouds, rather than strati-form cirrus clouds. Biases in the cloud-top height of thick clouds substantially contribute to the overestimate of OLR by CombRet. CombRet data is used to generate composite shortwave and longwave atmospheric heating rate pro-?les as a function of the local OLR. Though there is considerable variability in CombRet not directly related to OLR, the time-height structure of mean heating rate composites generated using OLR as the interpolant is broadly representative of tropical convective variability on intraseasonal time scales.

Shell, Karen M.↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

Modelling and Simulation of a Thermoelectric Heat Pump with Micro-Channel Heat Transfer

Thermoelectric heat pumps (TEHPs) have advantages of modularity and simple design for heating and cooling in some applications. Models of thermoelectric (TE) heat pumps are widely studied. Nevertheless, most existing modeling work focuses on the TE material or air-sourced TE modules. TEHP modeling, especially the relationship between modules and heat exchangers, has not been comprehensively conducted. This work presents a water-to-water TEHP modeling framework that combines Goldsmid’s approach for TE material performance, Gnielinski’s correlation for convective heat transfer, and thermal balance theory for heat exchange networks. This combined framework provides an accurate theoretical analysis of the water-to-water TEHP system. Subsequently, the framework was used to empirically determine TE material properties (electric resistivity, thermal conductivity, and Seebeck coefficient) that minimize modeling errors versus experimentally observed values from the literature. Finally, an additional set of experimental TEHP data was used to validate the model, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–20% when forecasting cooling capacity at a 30 K temperature lift. For future work, people can further develop models of TEHPs with an air-based heat sink on one side and water channels on the other side.

Wan, Hanlong↗

Compliant heat exchangers, heat pipes and methods for making same

A method for fabricating heat exchangers using additive manufacturing technologies. Additive manufacturing enables the manufacture of heat exchangers with complex geometries and/or with internal and external integral surface features. Additive manufacture also facilitates the manufacture of heat exchangers with regional variations, such as changes in size, shape and surface features. In one embodiment, the present invention provides a heat exchanger with a helicoidal shape that provides axial elastic compliance. In one embodiment, the internal channel of the heat exchanger varies along its length. The internal channel may have a cross-sectional area that increases progressively from one end to the other. In one embodiment, the external shape of the tubular structure may be non-circular to optimize heat transfer with an external heat transfer fluid. In one embodiment, the present invention provides a heat pipe with an internal wicking structure formed as an integral part of the additive manufacturing process.

Lara-Curzio, Edgar↗

Heat Exchangers Circuitry Optimization using Low-GWP Refrigerants in Reversible Heat Pump Applications

Tube-fin heat exchangers (TFHX) are widely used in heat pump applications. Circuitry optimization can improve system performance. Previous optimizations focus on improving component-level performance under a specific operating condition, i.e., the TFHX either works as a condenser or an evaporator. The optimal circuitry obtained under air conditioning (AC) mode cannot guarantee optimal performance when used in heat pump (HP) mode. This study implements a bi-objective formulation to achieve optimal system performance in both AC and HP modes. An integer permutation-based Genetic Algorithm is integrated with Heat Pump Design Model (HPDM) to perform heat pump optimization. Six refrigerants, i.e., R410A, R452B, R454B, R32, D2Y60 and L41a are investigated. Case studies show that optimal heat exchangers yield 2.1%-6.1% EER improvement under AC mode and 1.9%-8.5% COP improvement under HP mode. Use of this design approach can help assure a preferable performance of reversible heat pumps during both cooling and heating mode usage.

Li, Zhenning↗