Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Exchangers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Materials-to-device design of hybrid metal-polymer heat exchanger tubes for low temperature waste heat recovery

Heat exchangers for low temperature (<150 °C) waste heat recovery (WHR) are challenging due to severe constraints on materials costs, manufacturing methods, and maintenance opportunities after installation. Here, the use of polymers instead of metals, offers an avenue for cost reduction in WHR applications, provided the typical low thermal conductivity of polymers (~0.2 W m –1 K –1 ) that results in poor overall heat transfer coefficient can be overcome. Previous approaches to enhance the thermal conductivity of polymers remain problematic in terms of cost, thermal, and thermomechanical considerations. In this work, we propose a novel hybrid metal-polymer composite assembled from strips of polymer and copper. Polymer strips with metal-clad edges are wound helically and the interfaces between the strips joined to obtain a tube for a cross-flow heat exchanger. Interfaces are designed to enhance effective heat conduction across the material and increase the overall heat transfer coefficient. Through numerical simulations, we obtain metal-polymer layouts that achieve wall effective thermal conductivity ~1 W m –1 K –1 at ~23% or ~35% volume fraction of copper or aluminum, respectively. The conductivity enhancement is sufficient for typical low temperature WHR, resulting in a ~20% enhancement in the overall heat transfer coefficient compared to a similar all-polymer heat exchanger. Thermomechanical simulations revealed that the composite pipe designs can withstand >1.4 MPa internal pressure, under the normal operating conditions of the heat exchanger. Our work provides guidelines for designing macroscopic metal-polymer composites that can be adapted for specific requirements such as reduced materials costs, ease of manufacturing, and heat transfer enhancement. In conclusion, the optimized design of hybrid metal-polymer heat exchanger tubes potentially provides a scalable and cost-effective route toward harvesting waste heat from low temperature sources.

42 ENGINEERING↗

Multi-Physics Topology Optimization for Dual Flow Heat Exchangers

Current heat exchanger (HX) designs are subjected to strict constraints pertaining to their manufacturability through conventional lengthy and expensive processes consisting of subtractive, forming and brazing processes. Therefore, existing HXs are typically restricted to the classical and rather simple geometries, such as plate-fin or shell-tube geometries, with lower efficiency and larger size. To increase HX efficiencies, novel designs are needed. Recent advances in topology optimization (TO) and additive manufacturing (AM) offer significant flexibility in design and fabrication of complex geometries, with potentially superior thermo-mechanical performance and high-power density. On the other hand, there is no commercially available software tool that addresses the combined coupling of structural, fluid dynamics, and thermal with multiple materials (hot and cold streams, solid, and void space) in TO of HXs. The goal of this project is to develop a multi-physics multi-phase TO approach to enhance the performance of HXs. The optimized design will be additively manufactured and tested in a physical environment to quantify its performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat exchanger

A heat exchanger, as exemplified by a rocket combustion chamber, is constructed by stacking thin metal rings having microsized openings therein at selective locations to form cooling passages defined by an inner wall, an outer wall and fins. Suitable manifolds are provided at each end of the rocket chamber. In addition to the cooling channel openings, coolant feed openings may be formed in each of rings. The coolant feed openings may be nested or positioned within generally U-shaped cooling channel openings. Compression on the stacked rings may be maintained by welds or the like or by bolts extending through the stacked rings.

Sokolowski, D. E.↗

Hybrid metal-polymer heat exchanger

A heat exchanger includes a metal tube and a composite polymer fin in thermal contact with the metal tube. The fin is formed of a polymer and a thermally conductive filler such that the fin has a thermal conductivity greater than or equal to 0.5 Watts per meter Kelvin.

42 ENGINEERING↗

Branching heat exchangers

A heat exchanger includes an external casing and a core. The external casing includes a first inlet, a first outlet, a second inlet, and a second outlet. The core includes an array of branched channels connecting the first inlet and first outlet, an inlet header, and an outlet header. The inlet header is integrally formed with and fluidly connected to the first inlet. The outlet header is integrally formed with and fluidly connected to the first outlet. The branched channels and the external casing define a fluidic passage. The array of branched channels includes a first split, a first juncture, a secondary split, a secondary juncture, and a subset of splits and junctures. The first split and first juncture are common to an entirety of the array of branched channels. The subset of splits and junctures route fluid through interconnections between fluidly parallel branched channels.

Ranjan, Ram↗

Fault-Tolerant Heat Exchanger

A compact, lightweight heat exchanger has been designed to be fault-tolerant in the sense that a single-point leak would not cause mixing of heat-transfer fluids. This particular heat exchanger is intended to be part of the temperature-regulation system for habitable modules of the International Space Station and to function with water and ammonia as the heat-transfer fluids. The basic fault-tolerant design is adaptable to other heat-transfer fluids and heat exchangers for applications in which mixing of heat-transfer fluids would pose toxic, explosive, or other hazards: Examples could include fuel/air heat exchangers for thermal management on aircraft, process heat exchangers in the cryogenic industry, and heat exchangers used in chemical processing. The reason this heat exchanger can tolerate a single-point leak is that the heat-transfer fluids are everywhere separated by a vented volume and at least two seals. The combination of fault tolerance, compactness, and light weight is implemented in a unique heat-exchanger core configuration: Each fluid passage is entirely surrounded by a vented region bridged by solid structures through which heat is conducted between the fluids. Precise, proprietary fabrication techniques make it possible to manufacture the vented regions and heat-conducting structures with very small dimensions to obtain a very large coefficient of heat transfer between the two fluids. A large heat-transfer coefficient favors compact design by making it possible to use a relatively small core for a given heat-transfer rate. Calculations and experiments have shown that in most respects, the fault-tolerant heat exchanger can be expected to equal or exceed the performance of the non-fault-tolerant heat exchanger that it is intended to supplant (see table). The only significant disadvantages are a slight weight penalty and a small decrease in the mass-specific heat transfer.

Izenson, Michael G.↗

Active heat exchange system development for latent heat thermal energy storage

Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application (300 MW sub t storage for 6 hours). Two concepts were selected for hardware development: (1) a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and (2) a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which was nickel plated to decrease adhesion forces. In addition to improving performance by providing a nearly constant transfer rate during discharge, these active heat exchanger concepts were estimated to cost at least 25% less than the passive tube-shell design.

Alario, J.↗

Heat exchanger assemblies having embedded sensors

Heat exchanger assemblies are provided that can include: a heat exchanger housing; at least one primary conduit operably coupled to the heat exchanger housing and configured to convey a primary heat exchange fluid; at least one secondary conduit operably coupled to the heat exchanger housing and configured to convey a secondary heat exchange fluid; at least one thermal interface between the primary and secondary fluids; and at least one sensor operably engaged with the thermal interface. Heat exchanger assemblies including molten salt, liquid metal, or water/steam as part of the heat exchange fluids of the heat exchanger assembly are provided. The heat exchanger assemblies can include: at least one thermal interface between primary and secondary heat exchange fluids of the heat exchanger assembly; and a sensor operably engaged with the at least one interface.

Glass, III, Samuel W.↗

Initial characterization of a modular heat exchanger with an integral heat pipe

As part of the Civil Space Technology Initiative (CSTI) Advanced Technology program, a conceptual design of the Stirling space engibe (SSE) was generated to develop the technology base needed to meet the long duration, high capacity power requirements for future NASA space missions. The free-piston Stirling engine (FPSE) was chosen as the growth option in the CSTI program. An existing FPSE was modified as a test bed for a modular heat exchanger evaluation. Evaluation of the individual heat pipes before installation in the engine is described.

Schreiber, Jeffrey G.↗

High flux boiling heat transfer enhancement using triangle shaped vertical walls in two-phase microchannel heat exchangers

Two-phase heat exchangers allow heat loads to be dissipated with lower fluid flow rates without inducing thermal gradients, and high surface area microchannels further reduce the thermal resistance of these heat exchangers. However, there are many practical limits that prevent widespread use of two-phase microchannel heat exchangers. Many authors have looked to address these practical limits by treating the channel floors or creating artificial nucleation sites. Few works look to enhance heat transfer in the walls of channels with hydraulic diameters below 200 μm. This work is aimed at increasing the efficacy of high aspect ratio silicon microchannels that use R134a as the working fluid. The 125 parallel channels are 40 μm wide, 200 μm deep, and 2 mm long and contain a 15 μm wide, 150 μm long restriction at each inlet. The thermal resistance and dryout characteristics of traditional, plain-walled channels are compared to channels with 2 area enhancement patterns each of which increases the area available for heat transfer by 41%. Furthermore, a resistance to dryout is seen in both area-enhanced test sections, and a 15.5% reduction in thermal resistance is shown for the area-enhanced part with a 6 μm triangular pitch. Only a 7.8% performance increase is seen in the test section with a 3 μm pitch. Both area enhancement patterns induce an average 27% increase in pressure drop for all tests. Heat transfer characteristics are solved for using a finite element analysis (FEA) model. By examining heat transfer coefficients and local heat fluxes, it is postulated that the area enhancement reduces heat transfer coefficients and the performance increase is caused by increasing the number of active nucleation sites.

42 ENGINEERING↗

Investigating Liquid CO2 as a Coolant for a MTSA Heat Exchanger Design

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO 2) control for a future Portable Life Support System (PLSS), as well as water recycling. CO 2 removal and rejection is accomplished by driving a sorbent through a temperature swing of approximately 210 K to 280 K . The sorbent is cooled to these sub-freezing temperatures by a Sublimating Heat Exchanger (SHX) with liquid coolant expanded to sublimation temperatures. Water is the baseline coolant available on the moon, and if used, provides a competitive solution to the current baseline PLSS schematic. Liquid CO2 (LCO2) is another non-cryogenic coolant readily available from Martian resources which can be produced and stored using relatively low power and minimal infrastructure. LCO 2 expands from high pressure liquid (~5800 kPa) to Mars ambient (0.8 kPa) to produce a gas / solid mixture at temperatures as low as 156 K. Analysis and experimental work are presented to investigate factors that drive the design of a heat exchanger to effectively use this sink. Emphasis is given to enabling efficient use of the CO 2 cooling potential and mitigation of heat exchanger clogging due to solid formation. Minimizing mass and size as well as coolant delivery are also considered. The analysis and experimental work is specifically performed in an MTSA-like application to enable higher fidelity modeling for future optimization of a SHX design. In doing so, the work also demonstrates principles and concepts so that the design can be further optimized later in integrated applications (including Lunar application where water might be a choice of coolant).

Paul, Heather L.↗

Active heat exchange system development for latent heat thermal energy storage

Alternative mechanizations of active heat exchange concepts were analyzed for use with heat of fusion Phase Change Materials (PCM's) in the temperature range of 250 C to 350 C for solar and conventional power plant applications. Over 24 heat exchange concepts were reviewed, and eight were selected for detailed assessment. Two candidates were chosen for small-scale experimentation: a coated tube and shell that exchanger, and a direct contact reflux boiler. A dilute eutectic mixture of sodium nitrate and sodium hydroxide was selected as the PCM from over fifty inorganic salt mixtures investigated. Preliminary experiments with various tube coatings indicated that a nickel or chrome plating of Teflon or Ryton coating had promise of being successful. An electroless nickel plating was selected for further testing. A series of tests with nickel-plated heat transfer tubes showed that the solidifying sodium nitrate adhered to the tubes and the experiment failed to meet the required discharge heat transfer rate of 10 kW(t). Testing of the reflux boiler is under way.

Lefrois, R. T.↗

NEUP Final Report: Analysis of Thermal Transients for a Sodium-CO 2 Heat Exchanger

The design of heat exchangers for use in a supercritical carbon dioxide (sCO 2 ) Brayton cycle power converter must provide for acceptable performance for duty cycle events encompassing anticipated transients and postulated accidents. Argonne National Laboratory participated in the NEUP project, “Thermal Hydraulic and Structural Testing and Modeling of Compact Diffusion-Bonded Heat Exchangers for Supercritical CO 2 Brayton Cycle” with the task of conducting a comprehensive analysis of thermal transients for sCO 2 cycle heat exchangers, with emphasis on the sodium-to-CO 2 heat addition heat exchanger. A range of transients, from normal operation to severe accidents, were simulated with the coupled PDC and SAS4A/SASSYS-1 system level dynamic analysis computer codes. For each transient, the calculated change in the heat exchanger wall temperature is determined as a measure of the thermal loading. In addition, an analysis to find an equivalent helium-CO 2 heat exchanger was carried out to facilitate testing with helium rather than sodium on the hot side.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Contact Resistance and Fin Effectiveness of Enhanced, Brazed "Dogbone" Fin and Serpentine Tube Heat Exchangers for Air Conditioning and Heat Pump Applications

The energy consumption due to air conditioning is projected to increase by 1.3 and 4.5 times by 2050 compared to 2010 for members and non-members of the Organization of Economic Coordination and Development (OECD), respectively. Greenhouse Gas (GHG) emissions must be carefully managed to minimize their hazardous contribution to climate change. Air conditioners (AC) and heat pumps (HP) contribute with direct GHG emissions through systemic refrigerant leakage, which consequently degrades the system’s performance and therefore increases its indirect GHG emissions as well. To address this issue, the goals of new systems include minimizing leakage risk, using low global warming potential (GWP) refrigerants such as natural refrigerants, and increasing system efficiency. This paper presents part of the efforts in the development of a brazed “dogbone” fin to continuous serpentine tube heat exchanger (HX) for AC/HP applications. The main advantages of such technology are: 1) The potential to reduce 90% or more of the tube return-bends brazed joints compared to conventional tube-fin heat exchangers, thus minimizing leakage vulnerability, enabling the use of natural refrigerants like Propane and Ammonia that carry other concerning risks of flammability and toxicity ; and 2) The brazed fin to the tube joints should yield very low contact resistance. In order to quantify and estimate the impacts of contact resistance and fin effectiveness, a numerical-experimental study is investigated. The novel enhanced brazed “dog-bone” fin is compared to an equivalent pressure expanded fin. The results showed that the expanded fin has consistently greater effective heat transfer but greater contact resistance as well. Furthermore, the brazed fins have up to 20% lower pressure drop. The trade-off comparison shows that the thermal-hydraulic ratio between the two fins is equivalent for air velocities below 2m/s; for greater velocities, however, the expanded fin is favored since it has less fin efficiency penalty. For HVAC&R applications, the air velocities are typically low which makes the proposed technology competitive and a viable option in the pursuit of refrigerant leakage reduction.

30 DIRECT ENERGY CONVERSION↗

Active heat exchange system development for latent heat thermal energy storage

Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application. Two concepts selected for hardware development are a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which has been nickel plated to decrease adhesion forces. Suitable phase change material (PCM) storage media with melting points in the temperature range of interest (250 C to 400 C) were investigated. The specific salt recommended for laboratory tests was a chloride eutectic (20.5KCl-24/5 NaCl-55.0MgCl 2% by wt.), with a nominal melting point of 385 C.

Alario, J.↗

Impact of soil model complexity on the long-term thermal performance prediction of a new shallow bore ground heat exchanger

Shallow bore ground heat exchangers have been investigated in recent years because they have the potential to reduce the initial cost of the ground source heat pump system. Correctly modeling the transient heat transfer between the ground heat exchanger and the surrounding soil is essential for predicting a ground heat exchanger's performance. Simplification of the soil model could increase computation speed but sacrifice accuracy. This study investigates the impact of the soil model complexity on the annual performance prediction of a new shallow bore ground heat exchanger, the underground thermal battery (UTB). A simple 1D soil model and a more detailed 2D soil model were implemented, and they were validated against a 3D soil model. Overall, the resulting predictions of the UTB’s response from the 1D and 2D models to a given thermal load in different climates were compared. The results show that the root mean square differences between the hourly temperatures of the UTB during a year predicted using the two soil models range from 1.17°C to 3.39°C. As a result, the difference in the annual power consumption of the heat pump was between 0.7% and 3.4%. Furthermore, the dimensions of the UTB affected its performance, and a longer UTB was less sensitive to the soil models.

42 ENGINEERING↗