Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HYDROGEN STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hydrogen Fueling Station in Honolulu, Hawaii Feasibility Analysis

The Department of Energy Hydrogen & Fuel Cells Program Plan (September 2011) identifies the use of hydrogen for government and fleet electric vehicles as a key step for achieving “reduced greenhouse gas emissions; reduced oil consumption; expanded use of renewable power…; highly efficient energy conversion; fuel flexibility…; reduced air pollution; and highly reliable grid-support.” This report synthesizes several pieces of existing information that can inform a decision regarding the viability of deploying a hydrogen (H2) fueling station at the Fort Armstrong site in Honolulu, Hawaii.

08 HYDROGEN↗

Modeling Freight Traffic Demand and Highway Networks for Hydrogen Fueling Station Planning: A Case Study of U.S. Interstate 75 Corridor

The use of hydrogen as an alternative transportation fuel has gained much interest in recent years. Hydrogen can be utilized in electric vehicles equipped with hydrogen powertrains (including hydrogen internal combustion engines or fuel cells). Given that most of the freight in the U.S. is transported via diesel trucks, transition to hydrogen fuel would help achieve significant environmental benefits as well as accelerate the decarbonization of the freight transportation sector. This paper presents the methodology and results of a case study on modeling freight traffic demand and highway networks based on publicly available data for the Interstate 75 freight corridor. The purpose of this study is to prepare input traffic and network data that can support the planning of a hydrogen fueling station infrastructure. In particular, the data can be used for siting and characterizing an optimized framework of hydrogen fueling stations from candidate diesel stations along the Interstate 75 corridor. The methodologies developed and presented in this paper may be readily expanded and applied to any transport corridor given the data availability. This paper is the first in a series that will build out a comprehensive model to optimize a consolidated national hydrogen refueling infrastructure eco-system targeted at commercial vehicles.

Uddin, Majbah↗

Providing Levelized Cost and Waiting Time Inputs for HDV Hydrogen Refueling Station Planning: A Case Study of U.S. I-75 Corridor

Widespread use of diesel fuels in freight transportation leads to greenhouse gas (GHG) emissions that play an important role in air pollution. The air pollution, as well as the energy crisis, drives the transition from diesel fuel to cleaner and more energy-efficient fuels such as hydrogen fuels. With such a transition, the strategic planning and optimization of supporting refueling infrastructure along the national highway for heavy-duty vehicles (HDVs) become a necessity. Cost and service level are two essential factors to be considered in hydrogen refueling station location and capacity optimization. The service level in this study is assessed by the delay (waiting time) at fueling stations as well as the fueling demand fulfilled. To this end, this study presents a methodology to provide waiting time (delay) and levelized hydrogen fuel cost inputs under different station configurations (number of dispensers and fill rates) for hydrogen refueling station planning. Determining the station configurations based on the trade-off between the two inputs is further discussed. Particularly, this study points out that the levelized cost and waiting time are affected by hourly demand patterns and estimates the two inputs under different peak hour fueling demand scenarios. The results suggest that, with the same daily demand, the cost, as well as the waiting time, increases obviously with the peak hour demand. In the case study, the cost grows at least 30% when the peak hour visit frequency of the daily total visits increases from 5% (evenly distributed pattern) to 10% (the most common pattern for existing diesel fueling stations along I-75). Accounting for this peak hour effect in hydrogen refueling station planning is recommended. Overall, the waiting time model and cost analysis provide key inputs for optimizing hydrogen refueling station location and configurations based on anticipated refueling demand patterns. The paper is the second in a series that aims to build a comprehensive modeling plan and optimize hydrogen refueling infrastructure along the Interstate 75 (I-75) corridor for HDVs.

Liu, Yuandong↗

Techno-economic and thermodynamic analysis of pre-cooling systems at gaseous hydrogen refueling stations

In this study, we conducted a techno-economic and thermodynamic analysis of precooling units (PCUs) at hydrogen refueling stations and developed a cost-minimizing design algorithm for the PCU observing the SAE J2601 refueling protocol for T40 stations. In so doing, we identified major factors that affect PCU cost and energy use. The hydrogen precooling energy intensity depends strongly on the station utilization rate, but approaches 0.3 kWh e /kg-H 2 at full utilization. In early fuel cell electric vehicle markets where utilization of the refueling capacity is low, the overhead cooling load (to keep the heat exchanger cold at -40°C) results in significantly high PCU energy intensity because only a small amount of hydrogen is being dispensed. We developed a parameterized precooling energy intensity prediction formula as a function of the ambient temperature and station utilization rate. We also found that the Joule-Thomson effect of the flow control device introduces a significant increase in temperature upstream of the PCU’s heat exchanger (HX), which impacts the PCU design capacity. An optimal PCU (per dispenser, at 35°C HX inlet temperature) consists of a 13-kW refrigerator and a HX with 1400 kg of thermal mass (aluminum), which currently costs $70,000 (uninstalled). Finally, the total (installed) capital and operation cost of PCU at a fully utilized hydrogen refueling station adds $0.50/kg-H 2 .

08 HYDROGEN↗

Heavy Duty Hydrogen: Reference Station, Fueling Performance Test Device Concepts, and Station Capacity Model (CRADA Final Report)

This project will provide valuable information on (1) reference station design, (2) exploration of design concepts for a fueling performance test device, and (3) modeling of station capacity. The work applies to heavy-duty (HD) hydrogen fueling stations with large dispensing capacity and high flowrates servicing HD hydrogen trucks such as class 8 trucks in long haul applications. Additionally, a 4th area will provide near-real-time verification of fuel quality with on-site hydrogen contaminant detectors (HCDs) for use at both light-duty (LD) and HD stations. The work leverages national lab capabilities including staff and equipment at SNL, NLR, and ANL with collaboration and funding cost share from California agencies (CEC, SCAQMD, and GO-Biz). This project will provide tools and information that lead to more efficient design, acceptance, and commissioning of these larger capacity, higher flowrate stations serving HD applications. The HCD work will benefit both LD and HD stations. Note: The 4th area (HCD) mentioned above continued outside of this CRADA and will not be included in this report. There are no tasks included in this CRADA for HCD and the summary text for it should have been removed prior to this CRADA contract execution but remained in error and is included here for completeness.

08 HYDROGEN↗

Two-tier tube-trailer pressure consolidation operation method for hydrogen refueling station cost reduction

An operation strategy known as two-tier “pressure consolidation” of delivered tube-trailers (or equivalent supply storage) has been developed to maximize the throughput at gaseous hydrogen refueling stations (HRSs) for fuel cell electric vehicles (FCEVs). The high capital costs of HRSs and the consequent high investment risk are deterring growth of the infrastructure needed to promote the deployment of FCEVs. Stations supplied by gaseous hydrogen will be necessary for FCEV deployment in both the near and long term. Here, the two-tier pressure consolidation method enhances gaseous HRSs in the following ways: (1) reduces the capital cost compared with conventional stations, as well as those operating according to the original pressure consolidation approach described by Elgowainy et al. (2014) [1], (2) minimizes pressure cycling of HRS supply storage relative to the original pressure consolidation approach; and (3) increases use of the station’s supply storage (or delivered tube-trailers) while maintaining higher state-of-charge vehicle fills.

08 HYDROGEN↗

Loss Prevention Issues in Implementing New Hydrogen Technologies

This paper describes loss prevention issues in implementing hydrogen technologies specifically focusing on hydrogen fueling stations. Hydrogen has been used in industrial applications for many years. In the last ten years, there has been a significant interest in using hydrogen as a vehicle fuel primarily for fuel cell vehicles. The paper will address the following loss prevention associated with hydrogen fueling operations: Hydrogen ignition properties, Hydrogen behavior in confined and semi-confined spaces, High pressure hydrogen storage, and Hydrogen release detection. The paper will address both outdoor fueling operations for road vehicles and indoor fueling operations for industrial trucks. The paper will also discuss outreach Department of Energy (DOE) education activities intended to make users aware of the hazards and safety measures associated with new hydrogen technologies.

08 HYDROGEN↗

Manufacturing Competitiveness and Supply Chain Analyses for Hydrogen Refueling Stations

This slide deck was presented in the monthly FCTO webinar series (May 2017). The goal of this presentation was to share our latest results and remarks on the manufacturing competitiveness analysis of the hydrogen refueling stations (HRS). Manufacturing cost models were developed for major systems in the HRS such as compressors, storage tanks, chillers, heat exchangers, and dispensers. In addition to the cost models, we also discussed important remarks from our analysis for the international trade flows and global supply chain for the hydrogen refueling stations. The last part of the presentation also highlights effect of economies of scale and high production volumes on lowering the cost of the hydrogen at the pump.

30 DIRECT ENERGY CONVERSION↗

Ohio's First Electrolysis-Based Hydrogen Fueling Station

Presentation to the earth day coalition describing efforts with NASA GRC and Cleveland RTA on Ohio's hydrogen fueling station and bus demonstration. Project background and goals, challenges and successes, and current status.

fueling station↗

Next Generation Multi-Use Heavy-Duty High-Flow Direct-Fill Hydrogen Refueling Station with Standardized Design (CRADA Final Report)

The Contractor will build a liquid hydrogen (LH2) fueling station model that is capable of simulating the amount of hydrogen transferred from the liquid storage tank to the vehicle, depending on the station’s design and control scheme. This modeling work will allow the Parties to seek the design and control scheme of an LH2 station that can fill a targeted number of vehicles while meeting a time-average flow rate of 10 kg/min for each fill. While evaluating a high dispensing performance station design and control scheme, the Contractor will analyze the design and control scheme are economically viable.

08 HYDROGEN↗

Empirically verified analysis of dual pre-cooling system for hydrogen refuelling station

The dual cooling system at the California State University Los Angeles Hydrogen Research and Fueling Facility is analysed to predict the output hydrogen temperature in different ambient conditions. Initially, the facility was built with a coil chiller T20 cooling, sufficient for occasional fuelings. A flat plate evaporator system was added in series to resolve any issues for multiple fuelings even in the hottest weather. This study was commenced to verify the set points and determine the control requirements for the dual setup in order to inform future designs. A numerical-empirical model of the cooling system was developed by reverse engineering, using the station experimental measurements and database records. The subsystems are characterized separately but validated as a whole system imposing specific and standard operating conditions. The cooling model is tested with different inputs to validate the pre-set parameter variation of the cooling components. Ten scenarios were investigated to evaluate the fueling output parameters, testing two hydrogen temperature input trends (according to the facility initial conditions) and five ambient temperatures (from 15 °C to 35 °C). In closing, the simulation results have confirmed that the hydrogen output temperature remains within the range imposed by the SAE J2601 for each scenario studied, around -22 °C and -25 °C.

08 HYDROGEN↗

Validation of an Integrated Hydrogen Energy Station

This report presents the results of a 10-year project conducted by Air Products and Chemicals, Inc. (Air Products) to determine the feasibility of coproducing hydrogen with electricity. The primary objective was to demonstrate the technical and economic viability of a hydrogen energy station using a high-temperature fuel cell designed to produce power and hydrogen. This four-phase project had intermediate go/no-go decisions and the following specific goals: Complete a technical assessment and economic analysis of the use of high-temperature fuel cells, including solid oxide and molten carbonate, for the co-production of power and hydrogen (energy park concept).

08 HYDROGEN↗

National FCEV and Hydrogen Fueling Station Scenarios

This presentation provides a summary of the FY16 activities and accomplishments for NREL's national fuel cell electric vehicle (FCEV) and hydrogen fueling station scenarios project. It was presented at the U.S. Department of Energy Hydrogen and Fuel Cells Program 2016 Annual Merit Review and Peer Evaluation Meeting on June 9, 2016, in Washington, D.C.

30 DIRECT ENERGY CONVERSION↗

Insights from Hydrogen Refueling Station Manufacturing Competitiveness Analysis

In work for the Clean Energy Manufacturing Analysis Center (CEMAC), NREL is currently collaborating with Great Lakes Wind Network in conducting a comprehensive hydrogen refueling stations manufacturing competitiveness and supply chain analyses. In this project, CEMAC will be looking at several metrics that will facilitate understanding of the interactions between and within the HRS supply chain, such metrics include innovation potential, intellectual properties, learning curves, related industries and clustering, existing supply chains, ease of doing business, and regulations and safety. This presentation to Fuel Cell Seminar and Energy Exposition 2015 highlights initial findings from CEMAC's analysis.

30 DIRECT ENERGY CONVERSION↗

H2Fills™ [SWR-19-67]

H2FillS: Hydrogen Filling Simulation The Hydrogen Filling Simulation (H2FillS) software is a thermodynamic model designed to track and report on the transient change in hydrogen temperature, pressure, and mass flow when filling a fuel cell electric vehicle (FCEV). H2FillS simulates gas flow from the hydrogen station to the FCEV storage system. Using empirical fueling data sets, the model has been validated over a range of fueling conditions to match common light-duty FCEV fill profiles. Overall, it provides significant benefits to the light-duty fueling market and fill knowledge gaps of the interaction between a hydrogen station and an FCEV. Capabilities Use the comprehensive H2FillS model to: Safely design and operate a hydrogen fueling station Support code refinement with readily available data Develop system and operational improvements to reduce capital or operating costs at hydrogen stations or on-board FCEVs. How It Works H2FillS uses a "drag-and-drop" graphical user interface to simulate station and vehicle systems with preset parameters for common hydrogen station components as default values. When needed, users can define their own parameters to create their own station or vehicle components. Download H2FillS in Two Steps Read the terms of the end user software license agreement. Register to download the software. There are two versions of the model: A full-station model starts the simulation at high-pressure ground storage, runs through a dispenser, and ends at a vehicle storage system. A partial-station model starts at the dispenser breakaway and consists solely of the dispenser components and the vehicle storage system. H2FillS will automatically output fill performance data from the vehicle by tracking pressure and temperature throughout the fill. Users can input their own fill profiles into the model to run a variety of simulations.

Peters, Michael↗