At least 91 records · Page 5

Guideline 36 Savings Calculator v0.1

This software package contains a simple calculator that can be used to estimate savings from implementing a retrofit of HVAC controls to ASHRAE Guideline 36 in a multi-zone office building. Implemented in Excel, the calculator has a user-interface front-end to configure parameters of the case study, such as location, building size, and existing control strategies, and a back-end containing results from a large number of pre-run annual energy simulations. The software package also contains the simulation models and associated pre- and post-processing scripts to generate these results.

Blum, David↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Occupant thermal comfort inference using body shape information

Occupant thermal comfort may be inferred and improved using body shape information. Height, weight, and shoulder circumference of an occupant of a room may be obtained using a depth sensor. A model may be utilized that is trained on a dataset including information reflecting of occupant comfort within the room versus temperature, the model receiving, as inputs, the height, the weight, and the shoulder circumference of the occupant and environmental information and outputting a comfort class. A temperature set-point for is identified which the room occupant is identified by the model as having the comfort class being indicative of user comfort. Heating, ventilation, and air conditioning (HVAC) controls are adjusted for the room to the identified temperature set-point.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive Control for Residential HVAC Systems to Support Grid Services

In this paper, we propose an adaptive control strategy for residential buildings' heating ventilation and air conditioning (HVAC) systems to support grid services. The proposed control strategy captures the time-varying characteristics of the building and weather environments. It assigns to each building a local controller to maintain the indoor temperature within a desired comfort level, while the load aggregator allocates the assigned reference power provided by the distribution system operator to support a specific grid service, such as demand peak reduction, balancing supply and demand, and consuming the solar photovoltaic (PV) power locally. Simulation results are presented to verify the performance of the proposed control strategy in terms of maintaining the indoor temperatures of several buildings within the desired comfort bands while tracking the reference power profile. Also, a comparison with a recently developed model-free control strategy is presented.

Wu, Tumin↗

Signal Temporal Logic Control for Residential HVAC Systems to Accommodate High Solar PV Penetration

This paper proposes a new signal temporal logic (STL) control for ON/OFF residential buildings' Heating Ventilation and Air Conditioning (HVAC) systems. STL is used to control indoor temperatures while consuming most of the generated solar photovoltaic (PV) power locally to minimize its impact on the grid and reduce the need for large energy storage devices. In contrast to most, if not all, control mechanisms such as the traditional model predictive control (MPC), STL control allows for including temporal constraints in the control formulation to further relax indoor temperatures' constraints and allow them to exceed the comfort band limits for a prespecified (short) period of time. This relaxation allows to consume an additional PV power by the HVAC systems, which prevents such an unwanted intermittent power from affecting the grid. We formulate the MPC-based STL control mechanism to implement the objective. Simulation results show that the PV tracking performance has been improved while employing the proposed STL controller.

Wu, Tumin↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Cascaded Control for Building HVAC Systems in Practice

Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Convergence Rate of Model Reference Adaptive Control with Application to Building HVAC Systems

Model reference adaptive control (MRAC) has been studied for decades and successfully applied in multiple areas, including heating, ventilation, and air conditioning (HVAC) systems for buildings. MRAC is efficient in capturing the time-varying characteristics of buildings' indoor temperatures and outdoor weather environments. In this paper, the rate of convergence of MRAC is investigated, where a direct adaptive control with temperature set point reference tracking is used to regulate the indoor temperatures for buildings. Numerical results show that by controlling the HVAC systems of residential buildings using MRAC, the indoor temperatures converge Q-sublinearly to the desired temperature set points. In addition, the rate of convergence for MRAC is compared with a baseline adaptive model-free control method.

Wu, Tumin↗

Influence of overhead HVAC and aerosol control strategies on coarse mode particle dispersion and exposure in a full-scale room experiment

Coarse mode respiratory aerosols can carry viral loads over long distances and have very different dynamics than submicron particles, but experimental studies under realistic conditions remain limited. Here, to study the differential impacts on exposure under different mixing conditions, we co-released 7–10 µm particles and carbon dioxide (CO 2 )—which served as an indicator of gas and submicron particle dynamics—in a 158 m 3 room at LBNL's FLEXLAB facility with an overhead heating, ventilation, and air conditioning (HVAC) system. The room was arranged as a distanced meeting then a classroom with eight heated manikins and a researcher. Spatial variability was measured using 16 particle counters and 22–26 CO 2 sensors throughout the space. Conditions included: HVAC off or supply air at 1000-1060 m 3 h -1 at neutral, cooling, or heating temperatures; with and without 20% outdoor air; and added HVAC filtration, portable air cleaners (PACs), or a physical barrier between the speaker and occupants. We found that good mixing via neutral or cooling supply air or use of PACs under heating lowered coarse particle exposure at some locations, but increased exposure for one-quarter to two-thirds of manikins compared to poor mixing under heating. A physical barrier reduced direct transfer of coarse particles during heating, but less during cooling. High spatial variability shows that a single measurement cannot represent occupant exposure. Instantaneous air mixing assumptions overstate the effectiveness of ventilation, HVAC filtration, and upper-room germicidal ultraviolet disinfection for coarse particles, as relatively few particles reach the return grille or upper room under most conditions.

Air mixing↗

Integration of thermally anisotropic building envelopes with TES and advanced controls to tailor HVAC loads

Heating, ventilation, and air conditioning (HVAC) systems are the primary energy consumers in buildings to meet heating or cooling energy demands. The building envelope can play an active role in reducing this demand and associated costs by collecting thermal energy naturally available, such as diurnal temperature swings, solar irradiance, and night sky radiation cooling, to offset heating and cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lessons learned from the development and implementation of a workforce training curriculum for advanced controls for high performance HVAC systems

Over the past decade, academic research on advanced controls has slowly transitioned into new software platforms, giving rise to various companies developing and deploying these innovative products, including solutions for light commercial HVAC systems. However, the current workforce remains widely unprepared to install, maintain and operate these systems, particularly complex software-based control platforms, as most workforce training programs still focus on traditional building automation for large commercial buildings. This paper presents the development and piloting of curriculum for three key types of professionals: ● Technicians (trade-level): installing and maintaining modern high-performance HVAC systems and controls ● Programmers (undergrad-level): developing and implementing advanced controls ● Engineers and energy professionals (undergrad/grad-level): managing and evaluating system performance We share details of the material developed including training videos, open-source software, instruction manuals. We also present the results of a pilot implementation of the training materials with real students.

Casillas, Armando↗

Impact of Control on Availability and Cycling of Residential HVAC in a Real-World Experiment

Demand response is an important emerging part of smart grids and there is a large stream of research from theoretical and modeling perspectives. However, there is relatively little experimental evidence that could help researchers and building operators make informed decisions on best practices for modeling, developing, and deployment of control mechanisms. We contribute to the body of experimental research by providing numerical insights into the role and availability of residential HVAC systems for control. We share the findings on the duration of the cooling cycle, off cycle, and temperature settling time of HVAC systems from data collected from a smart neighborhood located in Atlanta, GA.

cycling↗

A neural-network-enhanced parameter-varying framework for multi-objective model predictive control applied to buildings

Management of the electrical grid is becoming more complex due to the increased penetration of alternative energy generation technologies and a broadening diversity of electric loads. This complexity creates challenges in balancing demand and generation that can increase the potential for grid instabilities. One effective way to address this issue is to leverage previously unexploited demand flexibility through advanced control strategies. In this work, we propose an advanced control method, called adaptive neural parameter-varying model predictive control (ANPV-MPC), to control the temperature and energy consumption of a building via its Heating, Ventilation, and Air Conditioning system. ANPV-MPC combines key ideas in parameter-varying control, adaptive control, and online learning strategies to bridge the gap between computationally efficient linear model predictive control and more accurate nonlinear model predictive control. The novelty in ANPV-MPC is the use of a physics-inspired Bayesian neural network to estimate the coefficients of the parameter-varying linear control model. The Bayesian neural network additionally provides uncertainty estimates, triggering online training to capture evolving building system conditions. We show that ANPV-MPC can approximate the building system dynamics with a 28.39% higher accuracy than traditional linear model predictive control, resulting in 36.23% better control performance without increasing complexity of the optimal control problem. ANPV-MPC also adapts in real time to previously unseen conditions using online learning, further improving its performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Controls Package for High Performance Interior Retrofit [Slides]

For the last few years, networked lighting control (NLCs) have promised significant energy savings beyond what is achieved through a basic light-emitting diode (LED) lighting retrofit. At the same time, NLCs can substantially increase the cost and complexity of the lighting retrofit. And as lighting system wattage declines because of the increasing efficiency of LEDs, advanced controls have less lighting energy to save and the cost-effectiveness of the NLC investment decreases. But NLCs can be leveraged to achieve significant energy savings and value by enhancing control of other building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗