Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC: Learning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Creating 3D Web-Based Game Environment Using BIM Models for Virtual On-Site Visiting of Building HVAC Systems

A web-based 3D game project was presented in this paper to demonstrate the process of using building information modeling (BIM) to create an interactive 3D on-line `Green' training environment. The system architecture, the implementation process and major components of this virtual training environment were discussed. Existing studies on BIM-based collaborations mainly focused on local-file-sharing approach using proprietary applications. Limited research focused on using BIM as an online gaming platform to create a web browser-based interactive 3D virtual environment for collaboration, learning and/or training. The gap was partially caused by the lack of understanding how to implement a BIM-based game in web browser environment. In this paper, the authors provided an implementation example using a hospital BIM model to create an interactive web-based 3D BIM game environment to allow users to visualize and interact with the BIM components using regular web browsers. The intention of this project is to create a proprietaryindependent training environment to conduct energy re-commissioning trainings for hospital facility management staff. This virtual BIM environment can potentially be customized for engineering student learning and project collaborations as well. The conclusion was that current BIM and game technology are mature enough to allow us to create serious web-based interactive learning/training virtual environment. The successful integration of BIM and web browsers paved the way for many learning and training applications, which need built-environment as context.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing Smart Home Privacy: A Tutorial on Local Differential Privacy Techniques for Frequency and Mean Estimation

The ubiquity of Internet of Things (IoT) systems has seamlessly integrated into our daily lives, particularly in smart homes where devices continuously monitor and optimize our living environments. These systems significantly contribute to home automation, energy efficiency, and overall comfort. However, this widespread connectivity poses inherent risks linked to the streaming of sensitive household data, necessitating robust privacy preservation mechanisms. This tutorial systematically examines privacy preservation through local differential privacy (LDP), with a particular focus on frequency and mean estimation techniques for smart home applications. Here, we present a comprehensive taxonomy of smart home data formats and provide detailed implementation guidance for event-based and w-event LDP mechanisms. Through practical examples using smart thermostats and HVAC systems, we demonstrate how these techniques can be effectively deployed in real-world scenarios. The tutorial concludes by examining emerging research directions, including adaptive privacy budgets and federated learning approaches, establishing a foundation for privacy-preserving smart home deployments.

Kotevska, Olivera [Oak Ridge National Laboratory (↗

Occupant comfort and behavior: High-resolution data from a 6-month field study of personal comfort systems with 37 real office workers

Personal Comfort Systems (PCS) provide individual occupants local heating and cooling to meet their comfort needs without affecting others in the same space. It saves energy by relaxing ambient temperature requirements for the HVAC system. Aside from these benefits, PCS offers a wealth of data that can describe how individuals interact with heating/cooling devices in their own environment. Recently developed Internet-connected PCS chairs have unlocked this opportunity by generating continuous streams of heating and cooling usage data, along with occupancy status and environmental measurements via embedded sensors. The data allow individuals' comfort and behavior to be learned, and can inform centralized systems to provide ‘just the right’ amount of conditioning to meet occupant needs. In summer 2016, we carried out a study with PCS chairs involving 37 occupants in an office building in California. During the study period, we collected >5 million chair usage data-points and 4500 occupant survey responses, as well as continuous measurements of environmental and HVAC system conditions. The data analysis shows that (1) local temperatures experienced by individual occupants vary quite widely across different parts of the building, even within the same thermal zone; (2) occupants often have different thermal preferences even under the same thermal conditions; (3) PCS control behavior can dynamically describe individuals' thermal preferences; (4) PCS chairs produce much higher comfort satisfaction (96%) than typically achieved in buildings. We conclude that PCS not only provide personalized comfort solutions but also offer individualized feedback that can improve comfort analytics and control decisions in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Whole-House Solutions Case Study: Winchester Homes and Camberly Homes

The Partnership for Home Innovation team worked with the builder to develop a new set of high performance home designs—including advanced wall and HVAC systems—that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltration rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, this report demonstrates through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the heating, cooling, air distribution, and ventilation systems intended to optimize the equipment size and configuration to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.

2x6 walls↗

Functional Mock-up Interface - Machine Learning Center (FMI-MLC) v1

The Functional Mock-up Interface - Machine Learning Center is a tool to interface the Python-Tensorflow library with building simulation models, to develop and train machine learning-based controls. In particular, this framework allows the use of reinforcement learning through the standardized Functional Mock-up Interface, an open industry standard for co-simulation. First application was the development of a controller for dynamic façade and heating ventilation and air conditioning (HVAC) systems.

Gehbauer, Christoph↗

Grupe Homes Enters the Whole-House Retrofit Market

This article for HomeEnergy Magazine, a trade magazine on energy efficient home construction, retrofitting, remodeling, and research, describes retrofit projects by Grupe Homes of Sacramento, California, a production builder who has worked with DOE's Building America program on energy-efficient home demonstration projects. In this project, The article is a case study of Grupe's decision to enter the energy efficient remodeling market when new home sales lagged due to the economic slowdown starting in late 2007. The article also describes an energy-efficient retrofit of of a 22-year-old, 3-bedroom home in California’s Central Valley done in 2009 by Grupe. The home is Grupe's first retrofit and was done according to the criteria of Home Performance with ENERGY STAR, a national program from the EPA and DOE that promotes a comprehensive, whole-house approach to making energy-efficiency improvements. Grupe's staff were trained through the California Building Performance Contractors Association and passed the Building Performance Institute test to learn how to conduct extensive energy audits of existing houses as well to perform the energy efficient retrofits. In the retrofit home, they did extensive air sealing, replaced and added insulation, and replaced inefficient HVAC equipment and leaky can lights. They cut air leakage from 2478 to 1115 cfm 50, a 55% reduction. A Building America case study on this project was distributed at the EEBA (Energy and Environmental Building Alliance) Annual Conference in Denver, Colorado, Sept 28-30, 2009. The Home Energy article was published in the March/April 2010 issue.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Air Handling Units to Create a Diverse Fault Dataset for FDD Innovation: Lessons Learned and Recommendations

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault datasets for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling unit and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for the air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, two detailed AHU models, which included the single duct AHU and dual duct AHU developed in the Modelica language and HVACSIM+ were employed to carry out annual simulations of numerous common sensor faults, mechanical faults, and control sequence faults. The fault inclusive data were then validated by comparing fault effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. We report some lessons learnt during the efforts of validating the high volumes of the FDD data sets. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Getting Beyond Widgets: Performance of Efficient Indoor Air Quality System Retrofit Packages for Schools A report on the modeled energy, greenhouse gas, and cost savings of several multi-measure retrofit packages for energy efficiency and indoor air quality in primary schools

School facilities are often underfunded with aging and poorly maintained HVAC and lighting systems. Most existing school buildings stand to benefit significantly from retrofits in terms of energy, cost, and emissions savings. Ventilation and indoor air quality (IAQ), which are important aspects of a healthy and productive learning environment, can also be enhanced by some energy efficiency measures (EEMs). Packaging energy efficiency and IAQ systems retrofits may represent a golden opportunity to improve performance in this critical building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Annual Air Handling Unit Fault Dataset for FDD Tools: Lessons Learned and Considerations for FDD Developers

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault data for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling units and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for a single duct air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, a detailed AHU model was employed to carry out annual simulations of numerous common sensor and mechanical faults, which were then validated by comparing their effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

Energy performance evaluation of the ASHRAE Guideline 36 control and reinforcement learning–based control using field measurements

This study evaluates the energy performance of ASHRAE Guideline 36–compliant control (ASHRAE 36 control) and reinforcement learning (RL)–based control through experimental field tests and a simulation study. Three field tests were conducted at Oak Ridge National Laboratory’s commercial building test facility in Oak Ridge, Tennessee: a baseline with a baseline conventional control, a test with ASHRAE 36 control, and a test with RL-based control. The selected ASHRAE 36 controls were trim and respond control, as well as variable air volume (VAV) box control. We compared the measured supply air temperature of the rooftop unit, VAV box supply air temperature, and VAV box supply airflow rate across the three test cases. The field data indicated that ASHRAE 36 controls operated as specified by ASHRAE Guideline 36. Based on these data, ASHRAE 36 control achieved a 45 % reduction in hourly averaged HVAC energy consumption compared with the baseline, and RL-based control achieved a 66 % reduction. These potential annual energy savings were confirmed using a calibrated whole-building energy model. Compared with the baseline, ASHRAE 36 control reduced HVAC energy consumption by 42 %, and RL-based control achieved a 54 % reduction. Furthermore, RL-based control reduced total HVAC energy consumption by 21 % more than ASHRAE 36 control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Technologies Office: Peer Review Report 2019

To ensure BTO projects are relevant, effective, and productively assisting the Office in meeting its goals, BTO conducts an annual peer review. The peer review is a formal, documented evaluation process that uses objective criteria and qualified independent reviewers to judge BTO-funded projects in terms of their technical, scientific, or business merit; actual or anticipated results; and productivity and effectiveness. Knowledge about the quality and effectiveness of current BTO projects and programs is essential for improving existing activities and informing future efforts. The BTO Peer Review is free and open to the public and provides an opportunity to learn more about BTO’s various projects and initiatives as well as promote collaborations and partnerships.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Autonomous Anomaly Detection for MPC Forecasts of HVAC Systems in Residential Communities

The use of residential heating, ventilation, and air conditioning (HVAC) to shift peak demand or provide ancillary services is a potential solution in the presence of older grids and distributed renewables. However, to ensure the efficient use of devices, utilities need to accurately forecast the load and adopt error correction schemes when necessary. While significant theoretical research exists in the area of predictive control of HVAC, little experimental evidence exists. The lack of experimental data in turn causes researchers to be unprepared for unsystematic errors which emerge due to the higher complexity of the data generating process. This study offers an anomaly detection methodology that uses unsupervised machine learning algorithms to detect and isolate these errors with different forecast error ranges. The results of anomaly detection procedure can then be used for error correction and would eventually help develop better predictive controllers. The methodology is tested using real world data from a smart neighborhood that currently operates in Atlanta. GA.

Lebakula, Viswadeep↗

BuildingIQ Technology Field Validation

This document describes a field validation and verification of the BuildingIQ Predictive Energy Optimization (PEO) technology based on a five-site study. BuildingIQ describes its PEO technology as a software-as-a-service (SaaS) platform that optimizes commercial building HVAC control for system efficiency, occupant comfort, and cost. It is targeted for use in large, complex buildings, and integrates with the building automation system (BAS) to conduct supervisory control. The PEO algorithm defines optimal space air temperature setpoints that are automatically implemented at the variable air volume (VAV) terminal units when possible, or through supply air temperature and duct static pressure setpoints at the air handling unit (AHU) level. The optimization is built upon a learned predictive model that provides a 24-hour ahead forecast of the building’s power profile, using weather forecasts and historical operational data; this model is updated every 4 to 6 hours. Demand-responsive load reductions may also be implemented.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Urban-scale Energy Modeling: Scaling Beyond Tax Assessor Data

In an attempt to attain building-specific characteristics for urban-scale building energy models, county-specific tax assessors’ data is often an initial data source. This data source can contain valuable information such as year built, area, height, HVAC type, and roof/wall descriptions.We will show examples of 2,000 fields from Hamilton County in Tennessee with examples of many fields which are not relevant to urban-scale building energy modeling, are incorrect compared to other data sources, and highlight some lessons learned working with such a data source.There are currently 3,142 counties in the United States, each with their own data format, field definitions, and data access policy. As urban-scale involves city-scale analysis potentially covering multiple counties and matures toward state- or nation-scale analysis, county-by-county approaches are not scalable. While there are efforts to unify these datasets, there is an increasing proliferation of data and algorithms that can cover wider areas and provide more accurate inputs for urban-scale models. This paper summarizes computer vision of imagery, cartographic layers, building type assessment, and model generation used to achieve scalable detection and analysis of buildings.

New, Joshua↗

Temporal Characterization and Filtering of Sensor Data to Support Anomaly Detection

Here, we present an approach for characterizing complex temporal behavior in the sensor measurements of a system in order to support detection of anomalies in that system. We first characterize typical behavior by extending a hidden Markov model-based approach to time series alignment. We then use a trace of that learned behavior to develop a particle filter that enables efficient estimation of the filtering distribution on the state space. This produces filtered residuals that can then be used in an anomaly detection framework. Our motivating example is the daily behavior of a building’s heating, ventilation, and air conditioning (HVAC) system, using sensor measurements that arrive every minute and induce a state space with 15,120 states. We provide an end-to-end demonstration of our approach showing improved performance of anomaly detection after application of alignment and filtering compared to the unaligned data. The proposed model is implemented as a computationally efficient R package alignts (align time series) built with R and Fortran 95 with OpenMP support.

47 OTHER INSTRUMENTATION↗

Addressing the Split Incentive Challenge for Enhanced Solar Adoption in Multifamily Rental Properties [Abstract]

The split incentive problem is particularly pronounced in rental markets, where landlords prioritize investments that directly increase property value or rental income. Since energy savings from solar photovoltaic (PV) systems primarily benefit tenants, landlords may perceive little return on investment unless mechanisms exist to recapture some of the financial gains. The primary objective of this project is to develop a publicly available, web-based tool to analyze the U.S. Department of Energy’s ResStock database, which models the U.S. residential building stock. The tool allows users to filter buildings by location, type, HVAC system, square footage, and other characteristics, and outputs typical electric load profiles. By leveraging location-specific electric load data, Fram Energy aims to advance business strategies that address the split incentive barrier and promote the adoption of solar PV installations in rental properties. In addition, a machine learning model will be developed to weigh the marginal contribution of building features across the dataset in predicting electricity demand, supporting guided decision making in forecasting electric load profiles. Lastly, based on each building’s location, load profile, and utility’s electricity rate, an optimized solar photovoltaic array and battery energy storage system will be sized to provide energy arbitrage opportunities.

14 SOLAR ENERGY↗