Development of an Additively Manufactured Capacitive Humidity Sensor for the International Space Station

The ability to measure humidity on the International Space Station and other long-duration spaceflight missions is a crucial part of the onboard systems. For example, the Environmental Control and Life Support System (ECLSS) needs to know the amount of humidity in the air to make decisions about whether it should spend power to run the dehumidifier systems to attempt to reclaim that water. Other issues can arise if the humidity reaches too high of levels and condensation builds up on electrical components. With that in mind, it is vital that the spacecraft keeps spare sensors on board or has the ability to manufacture new sensors on demand. An additively manufactured sensor would be additionally beneficial because it would save space onboard that would normally be taken up by spares, save money from costly resupply missions, and allow the sensor to be constantly updated with the most effective design. This Technical Memorandum outlines a development process carried out to design, manufacture, and test an additively manufactured humidity sensor.

Chang, K. T.↗

Cloud Uniformity Measurement from NASA's 2nd Fundamental Ice Crystal Icing Test - Part 2 (Temperature and Humidity)

This paper provides a characterization of the temperature and humidity variations within icing cloud flows generated during the second Fundamental Ice Crystal Icing Physics test conducted in NASA’s Propulsion Systems Laboratory, in June of 2018. The tests were conducted at airflow velocities of 85, 135, and 185 m/s, a static pressure of 44.8 kPa, and a total temperature of 7.2 ⁰C. A custom rearward facing probe and commercial total air temperature probe were used to obtain temperature and humidity profiles of the icing cloud flow leaving the exit duct plane. Additional background humidity measurements were also obtained from a commercial total water content probe. The probes captured the changes in temperature and humidity that took place at the test section after the cloud was activated. As the main altitude airflow interacts with the icing cloud, their thermodynamic properties undergo substantial changes. Due to the particle nature of the icing cloud, the droplets and ice crystals tend to redistribute within the cloud as it propagates with the main flow. Data will be presented that shows how these factors affect the thermodynamic property distribution within the icing cloud. A discussion is given of the thermal balances in the icing cloud, between the evaporating spray droplets and the airflow, as a basis for interpreting the measured results.

Crystal Icing↗

An Algorithm to Derive Temperature and Humidity Profile Changes Using Spatially and Temporally Averaged Spectral Radiance Differences

A linear inversion algorithm to derive changes of surface skin temperature and atmospheric temperature and specific humidity vertical profiles using spatially and temporally averaged spectral radiance differences is developed. The algorithm uses spectral radiative kernels, which is the top-of-atmosphere spectral radiance change caused by perturbations of skin temperature and air temperature and specific humidity in the atmosphere, and is an improved version of the algorithm used in earlier studies. Two improvements are the inclusion of the residual and cloud spectral kernels in the form of eigenvectors of principal components. Three and six eigenvectors are used for, respectively, the residual and cloud spectral kernels. An underlying assumption is that the spectral shape of the principal components is constant and their magnitude varies temporally and spatially. The algorithm is tested using synthetic spectral radiances with the spectral range of the Atmospheric Infrared Sounder averaged over 16 days and over a 10° × 10° grid box. Changes of skin temperature, air temperature, and specific humidity vertical profiles are derived from the difference of nadir-view all-sky spectral radiances. The root-mean-square difference of retrieved and true skin temperature differences is 0.59 K. The median of absolute errors in the air temperature change is less than 0.5 K above 925 hPa. The median of absolute errors in the relative specific humidity changes is less than 10% above 825 hPa.

Fang Pan↗

Global seasonal variations of the near-surface relative humidity levels on present-day Mars

We investigate the global seasonal variations of near-surface relative humidity and relevant attributes, like temperature and water vapor volume mixing ratio on Mars using calculations from modelled and measurement data. We focus on 2 AM local time snapshots to eliminate daily effects related to differences in insolation, and to be able to compare calculations based on modelling data from the Laboratoire de Météorologie Dynamique Mars General Circulation Model with the observations of Mars Global Surveyor Thermal Emission Spectrometer. We study the seasonal effects by examining four specific dates in the Martian year, the northern spring equinox, summer solstice, autumn equinox, and winter solstice. We identify three specific zones, where the near-surface relative humidity levels are systematically higher than in their vicinity regardless of season. We find that these areas coincide with low thermal inertia features, which control surface temperatures on the planet, and are most likely covered with unconsolidated fine dust with grain sizes smaller than ∼ 40 μm. By comparing the data of relative humidity, temperature and water vapor volume mixing ratio at three different heights (near-surface, ∼ 4m and ∼ 23m above the surface), we demonstrate that the thermal inertia could play an important role in determining near-surface humidity levels. We also notice that during the night the water vapor levels drop at ∼ 4m above the surface. This, together with the temperature and thermal inertia values, shows that water vapor likely condenses in the near-surface atmosphere and on the ground during the night at the three aforementioned regions. This condensation may be in the form of brines, wettening of the fine grains by adsorption or deliquescence. This study specifies areas of interest on the surface of present day Mars for the proposed condensation, which may be examined by in-situ measurements in the future.

Bernadett Pál↗

Regenerable Liquid Desiccants for High Efficiency Humidity Control in Microgravity

The NASA X-Hab project aims to design, manufacture, test, and prove functionality of an air humidity control subsystem to dehumidify and re-humidify air from a space cabin. The method of regulating cabin air humidity utilizes vortex phase separation, which uses an ionic liquid (IL) desiccant for air-water phase separation. This subsystem is intended to be integrated with a CO 2 removal system requiring de-humidified air to operate efficiently. The air humidity control subsystem is composed of a cold-desiccant or cold-side Vortex Phase Separator (VPS) that dehumidifies the cabin air. The dehumidified air exits the cold-side (CS) VPS chamber to flow into the CO 2 removal module, and the cold, water-laden liquid desiccant flows to a regenerative heat exchanger. From the heat exchanger the liquid desiccant continues to the heater. After heating, the desiccant flows into a hot-desiccant or hot-side (HS) VPS as the dehumidified air from CO 2 removal module enters through the HS VPS air inlet. The rehumidified air exits the HS VPS into the space cabin. One pump installed at the liquid exit of the CS VPS and one pump installed at the liquid exit of the HS VPS transport the fluid through the system. To evaluate the system’s efficiency and effectiveness, the temperature, pressure, flow rate and relative humidity are read, recorded, and analyzed at critical points along the module.

Gerardo Castro↗

Springtime SEA Air Is Consistently Both Smoky and Humid, but This Relationship (and Its Radiative Effects) Varies Spatially and Seasonally

The atmosphere over the southeast Atlantic Ocean (SEA) sees a consistent springtime biomass burning (BB) smoke from widespread agricultural fires on the African continent. This smoke layer is initially lofted high in a continental mixed layer (~5-6km) and is then transported westward in the free troposphere, where it overlies and ultimately mixes into the SEA stratocumulus-topped oceanic boundary layer. Coincident with this smoke is an elevated humidity signal which is present from the time a given airmass is over the continental source region. ORACLES (ObseRvations of Aerosols above CLouds and their intEractionS) was a NASA Earth Venture Suborbital mission with the goal of measuring aerosol, cloud, and atmospheric properties over this region during three deployments in September 2016, August 2017, and October 2018. A previous study discussed the spatial characteristics of the water vapor-BB plume observations in the September 2016 flight data and their degree of agreement with several atmospheric reanalyses and models. In the present work, we first discuss atmospheric chemistry, structure, and aerosol results from all three ORACLES deployments to place these results in a broader seasonal context. Despite the differing locations and season of each deployment, we show that there continues to be good agreement between the airborne ORACLES dataset and large-scale reanalyses, specifically the ECMWF ERA5 and CAMS reanalyses. Other reanalyses (specifically NASA's MERRA-2) preserved the observed correlation between meteorology and biomass burning conditions, but, as was seen for 2016, was frequently displaced spatially relative to the observations. The CAMS reanalysis performs better with water vapor than with CO. Results comparing CAMS column AOD to the field measurements show slight overestimates, consistent with previous analysis, but the good relationship observed between AOD and inlet-based aerosol extinction demonstrates this metric's utility to broader studies. The good ERA5/CAMS/ORACLES agreement allows us to next examine the multi-year seasonal patterns and trends beyond the three ORACLES deployment periods. Looking at seven years of reanalysis data for the BB season, we find distinct variations between each month/deployment in terms of vertical smoke distribution and correlation to atmospheric specific humidity, due to changing conditions through the BB season. Using k-means clustering of these climatological reanalysis, we identify six canonical atmospheric profile types of varying total atmospheric humidity and vertical structure and describe their changing incidence spatially and throughout the season, and six analogous profile types for carbon monoxide, allowing us to characterize the atmospheric structure of both vapor and BB over time throughout the SEA region. This classification will allow for a more complete analysis of the broader radiative and dynamical effects of humid aerosols overlying stratocumulus clouds.

Kristina Marie Myers Pistone↗

Atmospheric Humidity Underlies Irreproducibility of Formamidinium Lead Iodide Perovskites

Metal halide perovskite solar cells (PSCs) are infamous for their batch-to-batch and lab-to-lab irreproducibility in terms of stability and performance. Reproducible fabrication of PSCs is a critical requirement for market viability and practical commercialization. PSC irreproducibility plagues all levels of the community; from institutional research laboratories, start-up companies, to large established corporations. Here, in this work, the critical function of atmospheric humidity to regulate the crystallization and stabilization of formamidinium lead triiodide (FAPbI 3 ) perovskites is unraveled. It is demonstrated that the humidity content during processing induces profound variations in perovskite stoichiometry, thermodynamic stability, and optoelectronic quality. Almost counterintuitively, it is shown that the presence of humidity is perhaps indispensable to reproduce phase-stable and efficient FAPbI 3 -based PSCs.

14 SOLAR ENERGY↗

Prehydration of calcium sulfoaluminate (CSA) clinker at different relative humidities

The use of CSA cement in practice has been hindered by its unstable performance and short shelf-life caused by the prehydration of CSA clinker. In this study, the effect of ambient humidity on the prehydration rate and process of CSA clinker was investigated. The prehydration degree, ageing progress, and the dynamic change of mineral composition of CSA clinker exposed to five different relative humidities (ranging from 23% to 98%) for up to 180 days were studied. Experiments revealed that the ambient humidity of 60% RH can be considered a threshold value for storage of CSA clinker. Exposure of CSA clinker to RH higher than 60% will not only result in a significant decrease of hydraulic reactivity, but also in agglomeration of the clinker. Although the exposure of CSA clinker to RH lower than 60% has little effect on the hydraulic reactivity, the main hydration peak was found to be slightly delayed with the increase of RH.

36 MATERIALS SCIENCE↗

Performance study of the cross-flow Maisotsenko cycle in humid climate conditions

This paper presents a first numerical analysis of the cross-flow Maisotsenko cycle (M-Cycle) below dew-point evaporative cooler for humid climates with model including the water vapor condensation phenomenon. Proposed solution allows to cool ambient air below its dew-point temperature, by utilizing cooling energy in air extracted from the building, due to that it can be used as effective pre-cooling solution for traditional systems. Proposed unit has significant advantage over traditional counter and cross-flow units operating in heat recovery mode, hence it is almost insensitive on temperature of exhaust air. This is caused by effective pre-cooling of the exhaust air in its initial part. Operation in humid climates using cold extracted air results in condensation occurrence in the primary air channels, and hence partial dehumidification of the primary airflow (which allows to cool the air before its dew- point temperature). The Maisotsenko cycle exchanger used to recover heat in the air-conditioning system is compared with Maisotsenko exchanger that operates only on the ambient airflow and does not allow to recover heat from the exhaust airflow from a conditioned space. Achieved results showed that M-Cycle below dew-point air cooler can operate more effectively in humid climates than traditional cross-flow Maisotsenko cycle exchanger.

Condensation↗

Humidity’s impact on greenhouse gas emissions from air conditioning

We report that the increasing need to cool the air in our built environment is both a cause and an effect of climate change. Air conditioning accounts for a large portion of global greenhouse gas emissions today, which we estimate at 3.9%; however, the role that humidity plays in these emissions is often overlooked. Here, we show that the emissions associated with reducing air humidity (i.e., removing water vapor from air) are larger than emissions associated with reducing air temperature (i.e., cooling air). We calculate these emissions for today and 2050 and show how dramatically humidity-related emissions will increase with rising cooling demand around the world. We also calculate the minimum separation energy for removing water vapor from air and find that this is at least an order of magnitude less than the processes used today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of humidity of build chamber in hybrid manufacturing systems on part performance

Here hybrid manufacturing combines additive with subtractive machining operations which often require the use of a coolant, that can increase the humidity of the build chamber. The water vapor can be adsorbed on the powder surfaces and subsequently dissociate into hydrogen and oxygen during melting and can be absorbed by part during solidification. Here, we investigated the effect of build chamber humidity during hybrid manufacturing on the part quality on two most common classes of steels i.e., austenitic (316L) and ferritic (grade 91). We report that the humidity increase has a negligible effect on part performance of both classes of steels.

316L stainless steel↗

Mitigating humidity interference in chemiresistive hydrogen sensors through hydrophobic surface functionalization

Chemiresistive gas sensors based on semiconductor metal oxides, such as tin dioxide (SnO₂), are indispensable for detecting and monitoring toxic gases and pollutants, making them critical components in industrial and environmental applications. To enhance their performance, the metal oxides are loaded with noble metals such as palladium (Pd). However, ambient humidity poses a significant challenge to their performance. The presence of adsorbed water molecules on the oxide surface can considerably impair sensor sensitivity and overall performance. To address this issue, in this paper, we report on the application of an ultrathin, hydrophobic layer of hexamethyldisilazane to the surface of a Pd/SnO 2 sensor. This study investigates the influence of hydrophobic surface modifications on the metal oxide interface, focusing on their impact on sensor sensitivity and selectivity. The resulting sensor exhibits superior hydrogen sensing capabilities, operating effectively at low temperatures even in high humidity environments. Furthermore, the hydrophobic modification reduces the sensor’s susceptibility to interfering gases, thus enhancing its selectivity. The combined enhancements in moisture resistance and selectivity achieved through HMDS surface modification, along with the superior sensitivity of Pd/SnO₂ sensors, facilitate the development of gas sensors with enhanced humidity tolerance and broader applications.

Chemiresistive gas sensors↗

Brittle-to-Ductile Transitions of Polyelectrolyte Complexes: Humidity, Temperature, and Salt

Polyelectrolyte complexation is an entropically driven, associative phase separation that results in a polymer-rich polyelectrolyte complex (PEC) and a polymer-poor supernatant. PECs show promise as a new class of sustainable materials since they can be processed using aqueous solutions rather than organic solvents. Previous reports have looked at the mechanical properties and glass transitions of PECs as a function of temperature, relative humidity (rH), and salt concentration (CS), but establishing a universal understanding of how these parameters affect PEC mechanics has yet to be achieved. We examined the effects of temperature, rH, and CS on the mechanical properties of PECs formed from poly(methacrylic acid) and poly(trimethyl aminoethyl methacrylate) with a goal of establishing design rules for their mechanical response. Relative humidity was shown to have the most dramatic effect on the mechanical properties, with temperature and salt concentration having far less of an impact. Furthermore, we observed that the glass transition of PECs is tied to both temperature and relative humidity, creating a glass transition rH g /T g line that can be modulated by added salt. Finally, we looked at the thermodynamics behind the glass transition of PECs, which yielded similar energies as the condensation of water. Here, we propose the use of water and/or salt as a low energy and efficient method of processing PECs for various applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into Sustainable Nitrogen Fixation by Gas-phase Spectroscopic Measurements and Global Modeling of Reaction Intermediates in Humid Nitrogen Plasma

In this article, there is growing interest in reacting molecular nitrogen and water to sustainably synthesize fixed forms of nitrogen such as ammonia. In particular, low-temperature plasmas can activate these relatively inert feedstocks at or near room temperature without a catalyst. However, because of the enhanced reactivity and nonequilibrium chemistry, a diverse range of products is formed, and the underlying reaction mechanisms are exceedingly complex. In this work, we studied a simplified reactor consisting of a gaseous plasma containing controlled mixtures of nitrogen gas and water vapor. Densities of key chemical species such as N, H, OH, NH, and NO were measured by emission and laser-based spectroscopy as a function of the relative humidity. A global model was constructed and the reaction network was validated by comparing calculated species densities with experiments. We discover that N, a key initial intermediate for ammonia, strongly decreases in the presence of water vapor, and as a result, ammonia formation becomes limited at high relative humidity. This decrease is surprisingly not because N itself reacts, but because one of its main sources, an excited molecular nitrogen state, is reacted away. In addition, oxidation pathways for nitrogen, which lead to NO and related products, are found to be favored over reduction pathways because the corresponding reverse reactions are less significant. Together, this understanding helps explain previously reported observations of selectivity toward nitrogen oxides over ammonia, particularly at higher relative humidities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relative humidity threshold for oxygen generation by high-purity plutonium dioxides in 3013 containers

High-purity plutonium dioxide with adsorbed water in a sealed container can generate oxygen, but oxygen will not be generated in low water loading conditions. A threshold for oxygen generation has been observed in the hydrogen generation rate normalized by the specific power for high-purity plutonium dioxide. Normalized hydrogen generation rates above this threshold generate oxygen and below the threshold consume oxygen. The threshold rate is determined by the amount of water adsorbed onto the surface of the oxide. The relative humidity of the atmosphere that the oxide is in equilibrium with determines the amount of physisorbed water adsorbed on the surface. We calculate the relative humidity corresponding to the threshold rate as a function of mass and specific surface area of material stored in 3013 containers. Exceeding the calculated relative humidity may result in flammable gas mixtures of hydrogen and oxygen at some time during storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accuracy of Vaisala RS41 and RS92 Upper Tropospheric Humidity Compared to Satellite Hyperspectral Infrared Measurements

Radiosondes are important for calibrating satellite sensors and assessing sounding retrievals. Vaisala RS41 radiosondes have mostly replaced RS92 in the Global Climate Observing System (GCOS) Reference Upper Air Network (GRUAN) and the conventional network. This study assesses RS41 and RS92 upper tropospheric humidity (UTH) accuracy by comparing with Infrared Atmospheric Sounding Interferometer (IASI) upper tropospheric water vapor absorption spectrum measurements. Using single RS41 and RS92 soundings at three GRUAN and DOE Atmospheric Radiation Measurement (ARM) sites and dual RS92/RS41 launches at three additional GRUAN sites, collocated with cloud-free IASI radiances (OBS), we compute Line-by-Line Radiative Transfer Model radiances for radiosonde profiles (CAL). We analyze OBS-CAL differences from 2015 to 2020, for daytime, nighttime, and dusk/dawn separately if data is available, for standard (STD) RS92 and RS41 processing, and RS92 GRUAN Data Processing (GDP; RS41 GDP is in development). We find that daytime RS41 (even without GDP) has ~1% smaller UTH errors than GDP RS92. RS41 may still have a dry bias of 1–1.5% for both daytime and nighttime, and a similar error for nighttime RS92 GDP, while standard RS92 may have a dry bias of 3–4%. These sonde humidity biases are probably upper limits since “cloud-free” scenes could still be cloud contaminated. Radiances computed from European Centre for Medium-Range Weather Forecasts (ECMWF) analyses match better than radiosondes with IASI measurements, perhaps because ECMWF assimilates IASI measurements. Relative differences between RS41 STD and RS92 GDP, or between radiosondes and ECMWF humidity profiles obtained from the radiance analysis, are consistent with their differences obtained directly from the RH measurements.

54 ENVIRONMENTAL SCIENCES↗

Relative Humidity Measurement Assurance Program Results

During the summer of 1992, the National Conference of Standards Laboratories sponsored a relative humidity measurement assurance program (RHMAP) whose purpose was to enable each participating center to assess the quality of relative humidity calibrations being performed by their respective standards laboratories. This paper presents the data which was submitted by the participants during the first round of the program and shows the multi-laboratory comparisons of the 20%, 50%, and 80% relative humidity meaurements performed.

Humidity↗