Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Heat Entrapment Effects Within Liquid Acquisition Devices

We introduce a model problem to address heat entrapment effects or the local accumulation of thermal energy within liquid acquisition devices. We show that the parametric space consists of six parameters, namely the Rayleigh and Prandtl numbers, the aspect ratio, and heat flux ratios for the bottom, side, and top boundaries of the enclosure. For the range of Ra considered 1 to 10(sup 9), beyond Ra on the order of 10(sup 5), convective instability is the dominant mode of convection in comparison to natural convection. The flow field transitions to asymmetric modes at Ra on the order of 10(sup 7). Direct numerical simulation of a large geometric length scale prototype for Ra on the order of 10(sup 9) shows that the flow field evolves from small wavelength instability which gives rise to nonlinear growth of thermals, propagation of the instability occurs via growth of secondary and tertiary modes, and a travelling wave mode occurs prior to asymmetry. The effect of a large aspect ratio is to increase the number of modes in the vertical direction. Due to the slow diffusion of heat in the prototype, asymptotic states are not readily attained, we show that dynamical similarity can be used for a model which allows the attainment of asymptotic states and that transition to a chaotic state occurs for Ra on the order of 10(sup 9) via a broadband power spectrum. These dynamical events show that for the baseline condition in which heat is absorbed from background laboratory environment, higher heat flux is absorbed at the top and bottom boundaries of the enclosure than a nominal value of 34.9 ergs per square centimeter -second.

Duval, W. M. B.↗

Effects of heat stress on baroreflex function in humans

INTRODUCTION: Heat stress significantly reduces orthostatic tolerance in humans. The mechanism(s) causing this response remain unknown. The purpose of this review article is to present data pertaining to the hypothesis that reduced orthostatic tolerance in heat stressed individuals is a result of heat stress induced alterations in baroflex function. METHODS: In both normothermic and heat stressed conditions baroreflex responsiveness was assessed via pharmacological and non-pharmacological methods. In addition, the effects of heat stress on post-synaptic vasoconstrictor responsiveness were assessed. RESULTS: Generally, whole body heating did not alter baroreflex sensitivity defined as the gain of the linear portion of the baroreflex curve around the operating point. However, whole body heating shifted the baroreflex curve to the prevailing (i.e. elevated) heart rate and muscle sympathetic nerve activity. Finally, the heat stress impaired vasoconstrictor responses to exogenous administration of adrenergic agonists. CONCLUSION: Current data do not support the hypothesis that reduced orthostatic tolerance associated with heat stress in humans is due to impaired baroreflex responsiveness. This phenomenon may be partially due to the effects of heat stress on reducing vasoconstrictor responsiveness.

Review, Tutorial↗

Effect of heating rate on toxicity of pyrolysis gases from some elastomers

The effect of heating rate on the toxicity of the pyrolysis gases from six elastomers was investigated, using a screening test method. The elastomers were polyisoprene (natural rubber), styrene-butadiene rubber (SBR), ethylene propylene diene terpolymer (EPDM), acrylonitrile rubber, chlorosulfonated polyethylene rubber, and polychloroprene. The rising temperature and fixed temperature programs produced exactly the same rank order of materials based on time to death. Acrylonitrile rubber exhibited the greatest toxicity under these test conditions, and carbon monoxide was not found in sufficient concentrations to be the primary cause of death.

Hilado, C. J.↗

Phase change paint tests to investigate effects of TPS tiles on heating rates of the Rockwell space shuttle orbiter (test OH4C, model 21-0)

Information and data from wind tunnel tests conducted on 0.0175-scale models of the space shuttle orbiter are presented. The primary objective of the tests was to evaluate aerodynamic heating effects of the tiles in the thermal protection system (TPS). Tile gap depth and flow orientation effects on the TPS were investigated. Tile patterns were cut into the undersides of the orbiter models to simulate the gaps. One model was left smooth for comparison.

Quan, M.↗

Effects of Heating Configuration and Operating Parameters on Heat Transfer and Interfacial Physics of Microgravity Flow Boiling With Subcooled Inlet Conditions –Experiments Onboard the International Space Station

This study is part of the Flow Boiling and Condensation Experiment (FBCE), a collaborative effort between the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and the NASA Glenn Research Center. The FBCE fitted with the Flow Boiling Module (FBM) was launched to the International Space Station (ISS) in August 2021 and experiments were successfully performed from February to July 2022 to amass a large microgravity-flow-boiling database. This study is focused on heat transfer and flow visualization of microgravity flow boiling of n-Perfluorohexane in a rectangular channel of 5.0 mm height, 2.5 mm width (heated), and 114.6 mm length, with subcooled inlet conditions. High-speed-video photography is utilized to present flow patterns and temporal interfacial behavior. Heat transfer results are presented in the form of flow boiling curves and both parametric curves and streamwise profiles of wall temperature and heat transfer coefficient. Firstly, the parametric effects of mass velocity (199.4 – 3200.0 kg/m 2 s), inlet subcooling (0.2 – 46.0°C), and inlet pressure (124.2 – 176.7 kPa), on the aforementioned aspects are assessed for double-sided heating to establish them for a microgravity environment. Of these three parameters, mass velocity and inlet subcooling mostly determine the microgravity flow boiling behavior, while inlet pressure plays an insignificant role. Flow patterns for double-sided heating are more complex than those for single-sided heating due to interaction between the two vapor layers. Vapor interaction is minimized at high subcoolings and high mass velocities due to strong condensation offered by the subcooled bulk liquid layer separating them. Despite the different flow patterns, both single- and double-sided heating generally result in similar parametric trends and local heat transfer coefficients for similar operating conditions. Flow instabilities manifest as temporal flow anomalies and temperature oscillations, and their severity increases with increasing boiling number. Secondly, the effects of heating configuration are analyzed by comparing and contrasting several aspects of single- and double-sided heating data. The heat fluxes at which onset of nucleate boiling degradation (ONBD) and critical heat flux (CHF) occur are distinctly different for single- and double-sided heating. There exists a threshold inlet subcooling demarcating the dominance of flow acceleration and condensation effects in vapor removal from the near-wall region and replenishment of fresh liquid for boiling. Above the threshold, condensation from the near-wall region is dominant and single-sided heating yields higher heat fluxes, and below it, acceleration is dominant and double-sided yields higher heat fluxes. At mass velocity in the range of 200 – 2400 kg/m 2 s, the threshold inlet subcooling lies in the approximate range of 20 – 30°C (corresponding inlet quality of roughly -0.40 – -0.20).

Microgravity↗

Effect of heating rate on toxicity of pyrolysis gases from some synthetic polymers

The effect of heating rate on the toxicity of the pyrolysis gases from some synthetic polymers was investigate, using a screening test method. The synthetic polymers were polyethylene, polystyrene, polymethyl methacrylate, polycarbonate, ABS, polyaryl sulfone, polyether sulfone, and polyphenylene sulfide. The toxicants from the sulfur-containing polymers appeared to act more rapidly than the toxicants from the other polymers. It is not known whether this effect is due primarily to differences in concentration or in the nature of the toxicants. The carbon monoxide concentrations found do not account for the observed results.

Hilado, C. J.↗

Experimental investigation of gamma effects on heat transfer to a 0.006 scale Shuttle Orbiter at Mach 6

Real-gas effects on heating to the windward centerline of the Shuttle Orbiter and shock shape were simulated by testing a 0.006-scale Orbiter model in Mach 6 air and CF4 flows. The range of free-stream Reynolds number, based on model length, was 0.4 x 10 to the 6th to 5.3 x 10 to the 6th for air, resulting in laminar and turbulent heating. The Reynolds number for CF4 was 0.3 x 10 to the 6th and gamma was equal to 1.13, corresponding to a normal shock density ratio of 12 as compared to 5.25 in air. Angle of attack was varied from 15 deg to 45 deg in 5 deg increments. Centerline heating distributions were compared for the two gases, and to Mach 8 wind-tunnel data, predictions, and flight (STS-1 and STS-2) data. The present results revealed a significant increase in heating with increasing density ratio and decreasing Reynolds number at the lower angles of attack; the effects of density ratio and Reynolds number diminished with increasing angle of attack and were relatively small at the angles of attack for the hypersonic portion of Space Shuttle Orbiter flights STS-1 and STS-2. Wind-tunnel and flight heating distributions were in relatively good agreement, and the present heating rates in air were accurately predicted by a local infinite swept cylinder analysis.

Miller, C. G.↗

The Effects of Heat Treatment and Microstructure Variations on Disk Superalloy Properties at High Temperature

The effects of heat treatment and resulting microstructure variations on high temperature mechanical properties were assessed for a powder metallurgy disk superalloy LSHR. Blanks were consistently supersolvus solution heat treated and quenched at two cooling rates, than aged at varying temperatures and times. Tensile, creep, and dwell fatigue crack growth tests were then performed at 704 C. Gamma' precipitate microstructures were quantified. Relationships between heat treatment-microstructure, heat treatment-mechanical properties, and microstructure-mechanical properties were assessed.

Gabb, Timothy P.↗

Quantifying and Zoning Urban Heat Island Effects Using Unsupervised Machine Learning

This work explores the Urban Heat Island (UHI) effects in Maricopa County, Arizona, employing a simulation-based approach that combines large-scale building energy modeling with advanced spatial analysis. Utilizing the Automatic Building Energy Modeling (AutoBEM) software suite, we simulated the energy consumption for approximately 1.35 million buildings based on the Model America version 1.0 (MAv1) dataset. Our methodology incorporated spatial analysis at multiple scales, including individual buildings, clusters of zones determined by K-means clustering, and geographical level evaluation based on Zip codes. The results revealed significant variations in energy consumption and heat emissions across different building types and urban zones. High-emission hotspots identified through clustering pointed to areas most contributing to the UHI effects. Zip code-based area analysis further contextualized these findings, offering an urban context-based perspective on emission distribution and informing potential urban energy policies for mitigating UHI effects.

Chowdhury, Shovan [ORNL]↗

Quantifying Changes in Urban Albedo with NASA Earth Observations to Reduce the Urban Heat Island Effect in Cambridge, Massachusetts

Elevated temperatures resulting from the urban heat island (UHI) effect can have widespread impacts on human health, infrastructure, and ecosystems. These impacts can be exacerbated by changes in climate and extreme variation in regional temperature. By 2030, experts expect Cambridge, Massachusetts will experience warmer than average temperatures, more heat waves, and triple the number of abnormally warm days above 90°F per year. The NASA DEVELOP Program partnered with the City of Cambridge’s Community Development Department and the American Geophysical Union’s Thriving Earth Exchange to inform ongoing efforts aimed at reducing the impacts of urban heat in the city of Cambridge. The team used scenes obtained from High Resolution Orthoimagery and the National Agriculture Imagery Program in conjunction with building footprint data, to calculate rooftop albedo between 2008 and 2018. Using these results, maps displaying building-specific variation in albedo across Cambridge were created. A nighttime land surface temperature (LST) record for June, July, and August between 2003 and 2019 was constructed using the Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) nighttime LST product. Lastly, temperature anomalies were calculated for Cambridge using seasonally averaged nighttime LST values obtained from Aqua MODIS to display ‘hot spots’ for summers between 2004 and 2019. The results of this project were then incorporated into an interactive ArcGIS Dashboard. This work will allow end users to explore spatial and temporal trends in albedo, nighttime LST, and temperature anomalies to assess whether the City of Cambridge is successfully reducing the effects of UHIs.

NASA DEVELOP↗

The use of NOAA AVHRR data for assessment of the urban heat island effect

The objective of the study was to evaluate the use of a satellite-derived vegetation index and surface temperature estimates for the assessment of the difference in urban and rural air temperature due to the urban heat island effect. The difference in the ND (normalized difference) index between urban and rural regions appears to be an indicator of the difference in surface properties (evaporation and heat storage capacity) between the two environments that are responsible for the urban heat island effect. The use of the approach proposed here may provide a globally consistent method for assessing this phenomenon.

Gallo, K. P.↗

The Effect of Heating on the Degradation of Ground Laboratory and Space Irradiated Teflon® FEP

The outer most layer of the multilayer insulation (MLI) blankets on the Hubble Space Telescope (HST) is back surface aluminized Teflon® FEP (fluorinated ethylene propylene). As seen by data collected after each of the three servicing missions and as observed during the second servicing mission (SM2), the FEP has become embrittled in the space environment, leading to degradation of the mechanical properties and severe on-orbit cracking of the FEP. During SM2, a sample of aluminized-FEP was retrieved from HST that had cracked and curled, exposing its aluminum backside to space. Because of the difference in optical properties between FEP and aluminum, this insulation piece reached 200 C on-orbit, which is significantly higher than the nominal MLI temperature extreme of 50 C. This piece was more brittle than other retrieved material from the first and third servicing missions (SM1 and SM3A, respectively). Due to this observation and the fact that Teflon thermal shields on the solar array bi-stems were heated on-orbit to 130 C, experiments have been conducted to determine the effect of heating on the degradation of FEP that has been irradiated in a ground laboratory facility or in space on HST. Teflon FEP samples were x-ray irradiated in a high vacuum facility in order to simulate the damage caused by radiation in the space environment. Samples of pristine FEP, x-ray irradiated FEP and FEP retrieved from the HST during SM3A were heat treated from 50 to 200 C at 25intervals in a high vacuum facility and then tensile tested. In addition, samples were tested in a density gradient column to determine the effect of the radiation and heating on the density of FEP. Results indicate that although heating does not degrade the tensile properties of non-irradiated Teflon, there is a significant dependence of the percent elongation at failure of irradiated Teflon as a function of heating temperature. Irradiated Teflon was found to undergo increasing degradation in the elongation at failure as temperature was increased from room temperature to 200 C. Rate of degradation changes, which were consistent with the glass I transition temperatures for FEP, appeared to be present in both tensile and density data. The results indicate the significance of the on-orbit temperature of Teflon FEP with respect to its degradation in the low Earth orbital space environment.

Hubble Space Telescope↗

Film cooling effectiveness and heat transfer with injection through holes

An experimental investigation of the local film cooling effectiveness and heat transfer downstream of injection of air through discrete holes into a turbulent boundary layer of air on a flat plate is reported. Secondary air is injected through a single hole normal to the main flow and through both a single hole and a row of holes spaced at three diameter intervals with an injection angle of 35 deg to the main flow. Two values of the mainstream Reynolds number are used; the blowing rate is varied from 0.1 to 2.0. Photographs of a carbon dioxide-water fog injected into the main flow at an angle of 90 deg are also presented to show interaction between the jet and mainstream.

Eriksen, V. L.↗

The Effect of Heating on the Degradation of Ground Laboratory and Space Irradiated Teflon(r) FEP

The outer most layer of the multilayer insulation (MLI) blankets on the Hubble Space Telescope (HST) is back surface aluminized Teflon(R) FEP (fluorinated ethylene propylene). As seen by data collected after each of the three servicing missions and as observed during the second servicing mission (SM2), the FEP has become embrittled in the space environment, leading to degradation of the mechanical properties and severe on-orbit cracking of the FEP. During SM2, a sample of aluminized-FEP was retrieved from HST that had cracked and curled, exposing its aluminum backside to space. Because of the difference in optical properties between FEP and aluminum, this insulation piece reached 200 C on-orbit, which is significantly higher than the nominal MLI temperature extreme of 50 C. This piece was more brittle than other retrieved material from the first and third servicing missions (SM1 and SM3A, respectively). Due to this observation and the fact that Teflon thermal shields on the solar array bi-stems were heated on-orbit to 130 C, experiments have been conducted to determine the effect of heating on the degradation of FEP that has been irradiated in a ground laboratory facility or in space on HST. Teflon FEP samples were X-ray irradiated in a high vacuum facility in order to simulate the damage caused by radiation in the space environment. Samples of pristine FEP, X-ray irradiated FEP and FEP retrieved from the HST during SM3A were heat treated from 50 to 200 C at 25 intervals in a high vacuum facility and then tensile tested. In addition, samples were tested in a density gradient column to determine the effect of the radiation and heating on the density of FEP. Results indicate that although heating does not degrade the tensile properties of non-irradiated Teflon, there is a significant dependence of the percent elongation at failure of irradiated Teflon as a function of heating temperature. Irradiated Teflon was found to undergo increasing degradation in the elongation at failure as temperature was increased from room temperature to 200 C. Rate of degradation changes, which were consistent with the glass I transition temperatures for FEP, appeared to be present in both tensile and density data. The results indicate the significance of the on-orbit temperature of Teflon FEP with respect to its degradation in the low Earth orbital space environment.

deGroh, Kim K.↗