Ultrasonic evaluation of the strength of unidirectional graphite-polyimide composites

An acoustic-ultrasonic method is described that was successful in ranking unidirectional graphite-polyimide composite specimens according to variations in interlaminar shear strength. Using this method, a quantity termed the stress wave factor was determined. It was found that this factor increases directly with interlaminar shear strength. The key variables in this investigation were composite density, fiber weight fraction, and void content. The stress wave factor and other ultrasonic factors that were studied were found to provide a powerful means for nondestructive evaluation of mechanical strength properties.

Vary, A.↗

The 737 graphite composite flight spoiler flight service evaluation

The flight service experience of 110 graphite epoxy spoilers on 737 transport aircraft was reviewed as well as ground based environmental exposure of graphite epoxy material specimens for the period from April 1976 through April 1977. Several spoilers were installed on each of 27 aircraft representing seven major airlines operating throughout the world. A flight service evaluation program of at least 5 years is under way. As of April 30, 1977, a total of 766,938 spoiler flight hours and 1,168,090 spoiler landings were accumulated by the fleet. Based on visual ultrasonic, and destructive testing, there was no evidence of moisture migration into the honeycomb core and no core corrosion. Tests of removed spoilers and of ground based exposure specimens after the third year of service continue to indicate modest changes in composite strength properties.

Stoecklin, R. L.↗

The 737 graphite composite flight spoiler flight service evaluation

The flight-service experience of 110 graphite-epoxy spoilers on 737 transport aircraft and related ground-based environmental exposure of graphite-epoxy material specimens is reported. Spoilers were installed on each of 27 aircraft representing seven major airlines operating throughout the world. Based on visual, ultrasonic, and destructive testing, there is no evidence of moisture migration into the honeycomb core and no core corrosion. Tests of removed spoilers and of ground-based exposure specimens after the second year of service indicate modest changes in composite strength.

Stoecklin, R. L.↗

Effects of moisture in infrared thermography of resin matrix composites

Several multiply graphite polyimide composite specimens were examined by real-time infrared thermography in order to study the effects of moisture on their thermograms. Heat was injected from one side and IR emission detected on the opposite side using AGA Thermovision System-680. No differences between the thermograms of dry and water containing specimens were detected for defect-free specimens. However, the presence of trapped water in defective specimens modified the thermographic contrast significantly. It is concluded that: (1) IR thermography can be used to detect moisture in defective composites, and (2) because of the possibility of moisture camouflaging defects, IR thermography for subsurface defect detection should be supplemented by other techniques - such as acoustical imaging and X-radiography.

Singh, J. J.↗

The 737 graphite composite flight spoiler flight service evaluation

The flight service experience of 111 graphite-epoxy spoilers on 737 transport aircraft and related ground based enviromental exposure of graphite-epoxy material specimens is reported. Spoilers were installed on 28 aircraft representing seven major airlines operating throughout the world. Over 1,188,367 spoiler flight hours and 1,786,837 spoiler landings were accumulated by this fleet. Tests of removed spoilers and ground-based exposure specimens after the fifth year of service indicate modest changes in composite strength properties. Two incidents of trailing edge delamination with subsequent core corrosion were observed. Based on visual, ultrasonic, and destructive testing, there has been no evidence of moisture migration into the honeycomb core and no core corrosion.

Hoffman, D. J.↗

The 737 graphite composite flight spoiler flight service evaluation

A flight service report was prepared which covers the flight service experience of 111 graphite epoxy spoilers on 737 transport aircraft and related ground based environmental exposure of graphite epoxy material specimens. Spoilers were installed on 28 aircraft representing seven major airlines operating throughout the world. Tests of removed spoilers after the seventh year of service continue to indicate modest changes in composite strength properties. Two spoilers were tested, one with 6 and one with 7 years of service, and both had residual strengths that fall within the original static strength scatter band. Both these units had typical service included discrepancies when tested. Based on visual, ultrasonic, and destructive inspection there continues to be no evidence of moisture migration into the honeycomb core and no core corrosion in the deployed units.

Coggeshall, R. L.↗

On the off-axis tensile test for unidirectional composites

The off axis tensile test was examined experimentally to obtain actual displacement fields over the surface of graphite polyimide coupon specimens. The experimental results were compared with approximate analytical solutions and generated finite element results. An optical method of high sensitivity moire interferometry was used to determine the actual displacements to high precision. The approximate analytical solution and the finite element results compare very favorably with the measured centerline displacements in the test section, and the finite element displacement fields provide excellent agreement with the moire displacements throughout the specimen. A 15 degree fiber orientation and coupon aspect ratios of 5 and 15 are presented.

Nemeth, M. P.↗

Ultrasonic and mechanical characterizations of fatigue states of graphite epoxy composite laminates

Results of an exploration of the relationship between ultrasonic attenuation and fatigue survivability of graphite fiber epoxy composites fabricated under different cure conditions are reported. A total of 9 27 x 40 cm eight-ply graphite epoxy laminated specimens were formed, and fatigue tests were run on five partial samples at 73.5 N varying at 30 Hz, with tests ending at a 1.27 cm deflection. A pulsed oscillator generated sinusoidal waves and transducers recorded the passage of the ultrasonic waves for display on oscilloscopes. Cure pressures ranged from 0.52-0.85 MPa and cure temperatures were in the 150-200 C interval. Ultrasonic through-transmission at 4 MHz was performed prior to and during fatigue testing. The minimum void volume fraction occurred at 175 C and 0.86 MPa. The flexural stiffness decreased with the number of fatigue cycles past 10,000, when the attenuation also increased. Correlations were found between the 4.0 MHz signal attenuation and the void volume fraction, and between the number of fatigue cycles to failure and the 4.0 MHz signal attenuation.

Williams, J. H., Jr.↗

On the off-axis tension test for unidirectional composites

The off axis tensile test was examined experimentally to obtain actual displacement fields over the surface of graphite polyimide coupon specimens. The experimental results were compared with approximate analytical solutions and generated finite element results. An optical method of high sensitivity moireinterferometry was used to determine the actual displacements to high precision. The approximate analytical solution and the finite element results compare very favorably with the measured centerline displacements in the test section, and the finite element displacement fields provide excellent agreement with the moiredisplacements throughout the specimen. A 15 degree fiber orientation and coupon aspect ratios of 5 and 15 are presented. Previously announced in STAR as N82-23553

Herakovich, C. T.↗

Embedded gage impact study

Impact damage in graphite/epoxy laminates was characterized and transient strain history during impact was correlated. The material investigated was AS-4/3501-6 graphite/epoxy. Eight-ply and sixteen-ply quasi-isotropic laminates of 45/0/-45/90 sub s and 45/0/-45/90 sub 2s layups were fabricated with strain gages embedded between plies during the strain gages and leads from the highly conductive graphite fibers. The specimens were circular plates 12.7 cm (5 in.) in diameter and clamped along their circumference. The specimens were impacted with a 185 gm impactor, dropped from heights of 1.20 m and 1.65 m. An accelerometer was attached to the back surface of the specimen opposite the impact point and was used to trigger the recording instrumentation. The transient strain data were recorded with an eight channel waveform digitizer capable of sampling data at 0.5 microsec intervals. The data were stored, processed, and plotted by means of a microcomputer. Transient strain data were correlated with results from ultrasonic inspection of the specimens.

Schramm, S. W.↗

Electron emission and acoustic emission from the fracture of graphite/epoxy composites

In past studies it has been shown that the fracture of materials leads to the emission of a variety of species, including electrons, ions, neutral molecules, and photons, all encompassed by the term 'fractoemission' (FE). In this paper, electron emission (EE) from the fracture of single graphite fibers and neat epoxy resin is examined. Measurements of EE are also combined with the detection of acoustic emission (AE) during the testing of graphite-epoxy composite specimens with various fiber orientation. The characteristics of these signals are related to known failure mechanisms in fiber-reinforced plastics. This study suggests that by comparing data from AE and FE measurements, one can detect and distinguish the onset of internal and external failure in composites. EE measurements are also shown to be sensitive to the locus of fracture in a composite material.

Dickinson, J. T.↗

The 737 graphite composite flight spoiler flight service evaluation

The flight service experience of 111 graphite-epoxy spoilers on 737 transport aircraft and related ground based environmental exposure of graphite-epoxy material specimens is covered. Spoilers have been installed on 28 aircraft representing seven major airlines operating throughout the world. An extended flight service evaluation program of 15 years is presently underway. As of December 1984, a total of 2,092, 155 spoiler flight hours and 2,954,814 spoiler landings had been accumulated by this fleet.

Coggeshall, R. L.↗

Experimental measurement of material damping for space structures

A procedure for the measurement of material damping is described. The free decay of free-free beams, when lofted into free fall in vacuum, was recorded. Tests were performed on aluminum, graphite/epoxy, and graphite/magnesium metal matrix materials. Specimens with a fundamental free-free frequency below the elaxation frequency showed a higher level of damping and of stress dependence than predicted. For 0 sub 8 laminates, a material damping ratio of 0.00055 was found for fequencies varying from 45 Hz to 237 Hz. The damping was neither stress nor frequency dependent. For 90 sub 8 laminates, the damping ratio ranged from 0.0055 to 0.0066 as frequency ranged from 42 Hz to 143 Hz. Damping ratios for 90 sub 8 specimens were independent of stress. Experimentally measured damping ratios for metal matrix specimens with unidirectional graphite fibers, magnesium matrix, and either titanium or magnesium foil, ranged from .00039 to .00099, depending upon the matrix material, frequency, and possibly the stress range involved.

Crawley, E. F.↗

The 737 graphite composite flight spoiler flight service evaluation

The ninth flight service report was prepared in compliance with the requirements of Contract NAS1-11668. It covers the flight service experience of 111 graphite-epoxy spoilers on 737 transport aircraft and related ground-based environmental exposure of graphite epoxy material specimens for the period 1 Jan. 1985 through 31 Dec. 1986. Spoilers have been installed on 28 aircraft representing seven major airlines operating throughout the world. An extended flight service evaluation program of 15 years is presently underway. As of 31 Dec. 1986, a total of 3,339,608 spoiler flight-hours and 3,320,952 spoiler landings had been accumulated by this fleet.

Coggeshall, Randy L.↗

Investigation of nonlinear mechanical behavior of two superfine-grained graphites with DIC assisted disc splitting test

Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.

Lin, Lianshan [ORNL] (ORCID:0000000203399219)↗

Composite fracture using the normal stress ratio theory

Experiments were performed on center-notched specimens of unidirectional AS4/3501-6 graphite-epoxy subjected to varied far-field loading conditions. Specimens tested include on-axis and off-axis tensile coupons and Iosipescu shear specimens, allowing the study of normal, shear, and combined far-field loading conditions. From the tests, the direction of initial crack extension and the far-field stresses at crack initiation and fracture are obtained. The normal stress ratio theory is subsequently applied within a macroscopic-level homogeneous anisotropic stress solution to predict the direction of crack extension, critical stresses, and other crack growth behavior for the experiments. Comparison between experimental results and theoretical predictions indicates that application of the normal stress ratio theory within a macroscopic-level stress analysis has significant potential as an approach to modeling composite crack growth.

Beuth, J. L., Jr.↗

Mechanical behavior analysis using small-size graphite disc compression testing with digital image correlation methods

The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.

36 MATERIALS SCIENCE↗

Dynamic Deformation in Nuclear Graphite and Underlying Mechanisms

Time-dependent deformation in nuclear graphite is influenced by the creation and migration of radiation-induced defects in the reactor environment. This study investigates the role of pre-existing defects such as point defect clusters and Mrozowski cracks in nuclear graphite IG-110. Separate specimens were irradiated with a 2.8 MeV Au 2+ beam with a fluence of 4.38 × 10 14 cm −2 and an 8 MeV C 2+ beam with a fluence of 1.24 × 10 16 cm −2 . Microscopic specimens were either mechanically loaded inside a transmission electron microscope (TEM) or subjected to ex situ indentation-based creep loading. In situ TEM tests showed significant plasticity in regions highly localized around the Mrozowski cracks, resembling slip or ripplocation bands. Slip bands were also seen near regions without pre-existing defects but at very high stresses. Ex situ self-ion irradiation embrittled the specimens and decreased the creep displacement and rate, while heavy ion irradiation resulted in the opposite behavior. We hypothesize that the large-sized gold ions (compared to the carbon atoms) induced interplanar swelling as well as cross-plane channels for increased defect mobility. These findings illustrate the role of pre-existing defects in the dynamic relaxation of stresses during irradiation and the need for more studies into the radiation environment’s impact on the mechanical response of nuclear graphite.

creep deformation↗