Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Glass dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Design and development of a compressible dynamic stall facility

A dynamic stall facility offering a unique new capability for studies of compressibility effects on dynamic stall is described. This facility features complete visual access by mounting the test airfoil between optical-quality glass windows which are rotated in unison to produce the oscillating airfoil motion associated with helicopter rotor dynamic stall. By using the density gradients associated with the rapidly changing dynamic stall flow field, this facility permits simultaneous detailed investigation of the flow on the surface as well as in the flow field surrounding airfoils experiencing dynamic stall.

Carr, L. W.↗

Applications of ultrashort laser pulses in science and technology; Proceedings of the Meeting, The Hague, Netherlands, Mar. 12, 13, 1990

Topics discussed are on the generation of high-intensity femtosecond lasers, the high-repetition and infrared femtosecond pulses, and physics of semiconductors and applications. Papers are presented on the femtosecond pulse generation at 193 nm; the generation of intense subpicosecond and femtosecond pulses; intense tunable subpicosecond and femtosecond pulses in the visible and infrared, generated by optical parametric oscillators; a high-efficiency high-energy optical amplifier for femtosecond pulses; and the generation of solitons, periodic pulsing, and nonlinearities in GaAs. Other papers are on ultrafast relaxation dynamics of photoexcited carriers in GaAs, high-order optical nonlinear susceptibilities of transparent glasses, subnanosecond risetime high-power pulse generation using photoconductive bulk GaAs devices, femtosecond studies of plasma formation in crystalline and amorphous silicon, and subpicosecond dynamics of hot carrier relaxation in InP and GaAs.

Antonetti, Andre↗

Proceedings of the Second International Colloquium on Drops and Bubbles

Applications of bubble and drop technologies are discussed and include: low gravity manufacturing, containerless melts, microballoon fabrication, ink printers, laser fusion targets, generation of organic glass and metal shells, and space processing. The fluid dynamics of bubbles and drops were examined. Thermomigration, capillary flow, and interfacial tension are discussed. Techniques for drop control are presented and include drop size control and drop shape control.

Lecroissette, D. H.↗

Petrographic evidence for nonlinear cooling rates and a volcanic origin for Apollo 15 KREEP basalts

The results of petrographic studies of Apollo 15 KREEP basalt fragments are discussed. The Apollo 15 KREEP basalts display a wide range of grain size and texture, with some samples showing evidence for a two-stage (slow early, fast late) cooling in the form of phenocrysts, glomerocrysts, and large proportions of residual quenched glass. Two-stage cooling is common in volcanic, dynamic environments. The inference that these and other Apollo 15 KREEP basalts are volcanic requires a reexamination of the chemical and isotopic constraints on the genesis and regenesis of KREEP and early lunar evolution.

Ryder, Graham↗

Tethered variable gravity laboratory study: Low gravity process identification report

Experiments are described performable in the variable gravity environment, and the related compatible/beneficial residual accelerations, both for pure and applied research in the fields of Fluid Mechanics (static and dynamic), Materials Sciences (Crystal Growth, Metal and Alloy Solidification, Glasses, etc.), and Life Sciences, so as to assess the relevance of a variable G-level laboratory.

Briccarello, M.↗

Schlieren optics for leak detection

The purpose of this research was to develop an optical method of leak detection. Various modifications of schlieren optics were explored with initial emphasis on leak detection of the plumbing within the orbital maneuvering system of the space shuttle (OMS pod). The schlieren scheme envisioned for OMS pod leak detection was that of a high contrast pattern on flexible reflecting material imaged onto a negative of the same pattern. We find that the OMS pod geometry constrains the characteristic length scale of the pattern to the order of 0.001 inch. Our experiments suggest that optical modulation transfer efficiency will be very low for such patterns, which will limit the sensitivity of the technique. Optical elements which allow a negative of the scene to be reversibly recorded using light from the scene itself were explored for their potential in adaptive single-ended schlieren systems. Elements studied include photochromic glass, bacteriorhodopsin, and a transmissive liquid crystal display. The dynamics of writing and reading patterns were studied using intensity profiles from recorded images. Schlieren detection of index gradients in air was demonstrated.

Peale, Robert E.↗

Thermal Stability of Otto Fuel Prepolymer

Otto Fuel II contains a nitrate ester, plasticizer, and 2-NDPA as a stabilizer. Otto Fuel with stabilizers from three vendors was investigated by dynamic and isothermal DSC using samples sealed in a glass ampoule and by Isothermal Microcalorimetry (IMC) using 10 gram samples aged at 75 C for 35 days. DSC kinetics did not show differences between the stabilizer; the samples had an activation energy of 36.7 +/- 0.6 kcal/mol. However, IMC analysis was sensitive enough to detect small differences between the stabilizer, namely energy of interaction values of 7 to 14 Joules. DSC controlled cooling and heating at 5 C/min from 30 to -60 to 40 C experiments were similar and showed a crystallization peak at -48 +/- 1 C during cooling, and upon heating there was a glass transition temperature step at approx. -54 +/- 0.5 C and a melting peak at -28 +/- 0.4 C.

Tompa, Albert S.↗

Atomic Oxygen Durability of Second Surface Silver Microsheet Glass Concentrators

Second surface silver microsheet glass concentrators are being developed for potential use in future solar dynamic space power systems. Traditional concentrators are aluminum honeycomb sandwich composites with either aluminum or graphite epoxy face sheets, where a reflective aluminum layer is deposited onto an organic leveling layer on the face sheet. To protect the underlying layers, a SiO2 layer is applied on top of the aluminum reflective layer. These concentrators may be vulnerable to atomic oxygen degradation due to possible atomic oxygen attack of the organic layers at defect sites in the protective and reflective coatings. A second surface microsheet glass concentrator would be inherently more atomic oxygen durable than these first surface concentrators. In addition, a second surface microsheet glass concentrator design provides a smooth optical surface and allows for silver to be used as a reflective layer, which would improve the reflectivity of the concentrator and the performance of the system. A potential threat to the performance of second surface microsheet glass concentrators is atomic oxygen attack of the underlying silver at seams and edges or at micrometeoroid and debris (MMD) impacts sites. Second surface silver microsheet glass concentrator samples were fabricated and tested for atomic oxygen durability. The samples were iteratively exposed to an atomic oxygen environment in a plasma asher. Samples were evaluated for potential degradation at fabrication seams, simulated MMD impact sites, and edges. Optical microscopy was used to evaluate atomic oxygen degradation. Reflectance was obtained for an impacted sample prior to and after atomic oxygen exposure. After an initial atomic oxygen exposure to an effective fluence of approx. 1 x 10(exp 21) atoms/cm(exp 2), oxidation of the silver at defect sites and edges was observed. Exposure to an additional approx. 1 x 10(exp 21) atoms/cm(exp 2) caused no observed increase in oxidation. Oxidation at an impact site caused negligible changes in reflectance. In all cases oxidation was found to be confined to the vicinity of the seams, impact sites, edges or defect sites. Asher to in-space atomic oxygen correlation issues will be addressed.

deGroh, Kim K.↗

Estimation of Slow Crack Growth Parameters for Constant Stress-Rate Test Data of Advanced Ceramics and Glass by the Individual Data and Arithmetic Mean Methods

The two estimation methods, individual data and arithmetic mean methods, were used to determine the slow crack growth (SCG) parameters (n and D) of advanced ceramics and glass from a large number of room- and elevated-temperature constant stress-rate ('dynamic fatigue') test data. For ceramic materials with Weibull modulus greater than 10, the difference in the SCG parameters between the two estimation methods was negligible; whereas, for glass specimens exhibiting Weibull modulus of about 3, the difference was amplified, resulting in a maximum difference of 16 and 13 %, respectively, in n and D. Of the two SCG parameters, the parameter n was more sensitive to the estimation method than the other. The coefficient of variation in n was found to be somewhat greater in the individual data method than in the arithmetic mean method.

Choi, Sung R.↗

Dynamics of solid lubrication as observed by optical microscopy

A bench metallograph was converted into a micro contact imager by the addition of a tribometer employing a steel ball in sliding contact with a glass disk. The sliding contact was viewed in real time by means of projection microscope optics. The dynamics of abrasive particles and of solid lubricant particles within the contact were observed in detail. The contact was characterized by a constantly changing pattern of elastic strain with the passage of surface discontinuities and solid particles. Abrasive particles fragmented upon entering the contact, embedded in one surface and scratched the other; in contrast, the solid lubricant particles flowed plastically into thin films. The rheological behavior of the lubricating solids gave every appearance of a paste-like consistency within the Hertzian contact.

Sliney, H. E.↗

Dynamics of solid lubrication as observed by optical microscopy

A bench metallograph was converted into a 'micro contact imager' by the addition of a tribometer employing a steel ball in sliding contact with a glass disk. The sliding contact was viewed in real time by means of projection microscope optics. The dynamics of abrasive particles and of solid lubricant particles within the contact were observed in detail. The contact was characterized by a constantly changing pattern of elastic strain with the passage of surface discontinuities and solid particles. Abrasive particles fragmented upon entering the contact, embedded in one surface and scratched the other; in contrast, the solid lubricant particles flowed plastically into thin films. The rheological behavior of the lubricating solids gave every appearance of a paste-like consistency within the Hertzian contact.

Sliney, H. E.↗

A method for developing design diagrams for ceramic and glass materials using fatigue data

The service lifetime of glass and ceramic materials can be expressed as a plot of time-to-failure versus applied stress whose plot is parametric in percent probability of failure. This type of plot is called a design diagram. Confidence interval estimates for such plots depend on the type of test that is used to generate the data, on assumptions made concerning the statistical distribution of the test results, and on the type of analysis used. This report outlines the development of design diagrams for glass and ceramic materials in engineering terms using static or dynamic fatigue tests, assuming either no particular statistical distribution of test results or a Weibull distribution and using either median value or homologous ratio analysis of the test results.

Heslin, T. M.↗

A Limited Comparison of the Thermal Durability of Polyimide Candidate Matrix Polymers with PMR-15

Studies were conducted with six different candidate high-temperature neat matrix resin specimens of varied geometric shapes to investigate the mechanisms involved in the thermal degradation of polyimides like PMR-15. The metrics for assessing the quality of these candidates were chosen to be glass transition temperature (T(sub g)), thermo-oxidative stability, dynamic mechanical properties, microstructural changes, and dimensional stability. The processing and mechanical properties were not investigated in the study reported herein. The dimensional changes and surface layer growth were measured and recorded. The data were in agreement with earlier published data. An initial weight increase reaction was observed to be dominating at the lower temperatures. However, at the more elevated temperatures, the weight loss reactions were prevalent and probably masked the weight gain reaction. These data confirmed the findings of the existence of an initial weight gain reaction previously reported. Surface- and core-dependent weight losses were shown to control the polymer degradation at the higher temperatures.

Bowles, Kenneth J.↗

High Temperature VARTM of Phenylethynyl Terminated Imides

Fabrication of composite structures using vacuum assisted resin transfer molding (VARTM) is generally more affordable than conventional autoclave techniques. Recent efforts have focused on adapting VARTM for the fabrication of high temperature composites. Due to their low melt viscosity and long melt stability, certain phenylethynyl terminated imides (PETI) can be processed into composites using high temperature VARTM (HT-VARTM). However, one of the disadvantages of the current HT-VARTM resin systems has been the high porosity of the resultant composites. For aerospace applications, the desired void fraction of less than 2% has not yet been achieved. In the current study, two PETI resins, LaRC PETI-330 and LaRC PETI-8 have been used to make test specimens using HT-VARTM. The resins were infused into ten layers of IM7-6K carbon fiber 5-harness satin fabric at 260 C or 280 C and cured at 371 C. Initial runs yielded composites with high void content, typically greater than 7% by weight. A thermogravimetric-mass spectroscopic study was conducted to determine the source of volatiles leading to high porosity. It was determined that under the thermal cycle used for laminate fabrication, the phenylethynyl endcap was undergoing degradation leading to volatile evolution. By modifying the thermal cycle used in laminate fabrication, the void content was reduced significantly (typically approximately 3%). Densities of the composites were determined using a density gradient column and the glass transition temperatures of the cured composites were measured by dynamic mechanical analysis. Photomicrographs of the panels were taken and void contents were determined by acid digestion. The results of this work are presented herein.

Cano, Roberto J.↗

Apollo 17 ropy glasses

Ropy glasses are a major soil component in the Apollo 17 gray soils 74240 and 74260. These particles form a distinct morphological type characterized by a wide range of dynamic shapes with a diagnostic sorted and welded fine-grained debris coating. Apollo 17 ropy glasses show abundant evidence for shock. Shocked lithic and mineral inclusions, lack of any igneous textures, and lechatelierite, all indicate an impact origin. A striking similarity is observed between the lunar ropy glasses and the glass impact bombs (Flaedle) of the Ries Crater in Germany. A highland basaltic composition was observed for the Apollo 17 ropy glasses in contrast to the KREEP composition of ropy glasses from the Apollo 12 and Apollo 14 landing sites. Other workers have presented convincing evidence that ejecta from Tycho reached the Taurus-Littrow Valley, and these ropy glasses may represent Tycho ejecta. However, the close stratigraphic association of the ropy glasses with the greater than 3.5 b.y. old orange glass suggests the ropy glasses may be too old to be Tycho ejecta, which should be only about 100 m.y. old. If this is the case, the ropy glasses represent impact glasses from a very old impact in an unknown highlands source area.

Fruland, R. M.↗

Acoustic Levitation Containerless Processing

This research program consists of the development of acoustic containerless processing systems with applications in the areas of research in material sciences, as well as the production of new materials, solid forms with novel and unusual microstructures, fusion target spheres, and improved optical fibers. Efforts have been focused on the containerless processing at high temperatures for producing new kinds of glasses. Also, some development has occurred in the areas of containerlessly supporting liquids at room temperature, with applications in studies of fluid dynamics, potential undercooling of liquids, etc. The high temperature area holds the greatest promise for producing new kinds of glasses and ceramics, new alloys, and possibly unusual structural shapes, such as very uniform hollow glass shells for fusion target applications. High temperature acoustic levitation required for containerless processing has been demonstrated in low-g environments as well as in ground-based experiments. Future activities include continued development of the signals axis acoustic levitator.

Whymark, R. R.↗

Dynamic Mechanical Properties of N-Phenylnadimide Modified PMR Polyimide Composites

The rheological behavior of newly developd Celion 6000/N-phenylnadimide modified PMR polyimide and PMR-15 composites was investigated. The dynamic mechanical properties were correlated with the structure of N-phenylnadimide modified PMR polyimides. The storage modulus (G'), loss modulus (G''), and loss tangent (tan delta) of four composite systems were measured over a temperature range from -150 to 400 C. Three well defined peaks were seen in the regions of 360, 100, and -120 C, corresponding to the alpha, beta, and gamma relaxations, respectively, of the matrix resins. The activation energies of the alpha, beta, and gamma relaxations were estimated to be 232, 60, and 14 kcal/mole, respectively, for PMR-15. Addition of N-phenylnadimide to the PMR-15 composition lowered the glass transition temperature and the activation energies of PMR-15 polyimide. The dynamic mechanical data appear to be consistent with the formation of a copolymer from N-phenylnadimide and a PMR-15 prepolymer.

Pater, R. H.↗