Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Microliter-sized ionization device and method

A microliter-sized metastable ionization device with a cavity, a sample gas inlet, a corona gas inlet and a gas outlet. A first electrode has a hollow and disposed in the cavity and is in fluid communication with the sample gas inlet. A second electrode is in fluid communication with the corona gas inlet and is disposed around the first electrode adjacent the hollow end thereof. A gap forming means forms a corona gap between the first and second electrodes. A first power supply is connected to the first electrode and the second power supply is connected to the second electrode for generating a corona discharge across the corona gap. A collector has a hollow end portion disposed in the cavity which is in fluid communications with the gas outlet for the outgassing and detection of ionized gases. The first electrode can be a tubular member aligned concentrically with a cylindrical second electrode. The gap forming means can be in annular disc projecting radially inwardly from the cylindrical second electrode. The collector can have a tubular opening aligned coaxially with the first electrode and has an end face spaced a short distance from an end face of the first electrode forming a small active volume therebetween for the generation and detection of small quantities of trace analytes.

Cohen, Martin J.↗

Modeling the use of mobile modular gas samplers in near-field detection

The Wireless Independent Noble Gas Sampler (WINGS) is a mobile, modular gas sampling system designed for use in low infrastructure environments. In the case of a suspected underground nuclear explosion (UNE), WINGS units could be deployed to detect noble gases emanating from the suspected explosion site or identify gases originating from another source entering the local area from offsite. In conclusion, this work uses the atmospheric transport modeling tool inline WRF-HYSPLIT to test the effectiveness of WINGS units around a suspected UNE site as a function of sampler density and distance from the emission point of gases from a UNE.

Air sampling↗

Developing mass spectrometric techniques for boundary layer measurement in hypersonic high enthalpy test facilities

Thermodynamic flow properties of gases in the boundary layer or the flowfield have been mainly deduced from pressures and temperatures measured on a model. However, further progress with respect to an understanding of these properties requires a more complete characterization of the layer including determination of the gas composition and chemistry. Most attempts to measure boundary layer chemistry involve the employment of a mass spectrometer and an associated gas sampling system. The three major limiting factors which must be addressed for species measurement in aerothermodynamic investigations on models at reentry stream velocities, are gas sampling effects, instrument limitations, and problems with data acquisition. The present investigation is concerned with a concentrated effort to quantitatively identify and correct for instrument and sampling system effects, and to develop a miniaturized high performance mass spectrometer for on-model real-time analysis of the boundary layer and its associated atmosphere.

Wood, G. M., Jr.↗

System automatically supplies precise analytical samples of high-pressure gases

High-pressure-reducing and flow-stabilization system delivers analytical gas samples from a gas supply. The system employs parallel capillary restrictors for pressure reduction and downstream throttling valves for flow control. It is used in conjunction with a sampling valve and minimizes alterations of the sampled gas.

Langdon, W. M.↗

Ammonia Analysis by Gas Chromatograph/Infrared Detector (GC/IRD)

Methods are being developed at Marshall Space Flight Center's Toxicity Lab on a CG/IRD System that will be used to detect ammonia in low part per million (ppm) levels. These methods will allow analysis of gas samples by syringe injections. The GC is equipped with a unique cryogenic-cooled inlet system that will enable our lab to make large injections of a gas sample. Although the initial focus of the work will be analysis of ammonia, this instrument could identify other compounds on a molecular level. If proper methods can be developed, the IRD could work as a powerful addition to our offgassing capabilities.

Scott, Joseph P.↗

Investigating Commercial Off-The-Shelf (COTS) Glovebox and Support Components Compared to Custom Curatorial Laboratories

There is a need envisioned to investigate the application of commercial off-the-shelf (COTS) systems as tools that could be used within commercial preliminary curation as the expected space economy is supported and begins to take flight. NASA is involved with supporting and developing the space economy [1] and therefore it’s feasible that at some point, a commercial space company would bring back materials and either store initially, or permanently, within COTS equipment as a stand-in for custom curation laboratories. While utilizing opportunities to explore this capability at NASA-Johnson Space Center (JSC) during the establishment of other laboratories [2] it was realized that cleanliness and/or other properties could be evaluated for these COTS systems during their installation in advanced research facilities that are not ISO-class rated clean rooms. Several aspects of a COTS-Curation system were explored including various gloves for curation manipulation within a negative pressure glovebox (Fig.1), Balazs organic and inorganic contaminant levels testing prior to glovebox ever being used, mode swapping comparison of recirculation vs. single pass, constant monitoring of oxygen (O2) and moisture (H2O) levels in various conditions, etc. To acquire inorganic and organic compound loads inside the glovebox, Balazs wafer testing and gas sampling were implemented. These are standardized analytical tests provided by Balazs™ NanoAnalysis, a division of Air Liquide USA. Deployment of 8-inch silicon wafer witness plates for 24-hours in an undisturbed environment capture the organic compound load and inorganic trace metal contents which can be obtained by Vapor Phase Decomposition Inductively Coupled Plasma Mass Spectrometry (VPD ICP-MS). Balazs gas sample analysis was also performed for better measurements of volatile organic compounds (VOC) in glovebox air analyzed by Thermal Desorption Gas Chromatography Mass Spectrometry (TD GC-MS). These analytical testings were carried out in a controlled ultra high pure (UHP) gaseous nitrogen (N2)-purged environment where oxygen and moisture contents were continuously monitored at certain temperature and pressure. The preliminary outcomes of these testings are promising. The COTS systems appear to maintain the steady-state controlled environment for days, if not weeks, with uninterrupted gaseous N2-supply which was operated from a standard medium pressure LN2 250L 230L dewar, exchanged as needed. The outgassing load can be maintained by selecting the glove materials that have the least outgassing and particle shedding performances. Further experiments will be considered to validate the preliminary findings. While this project is exploratory, it is not intended as an endorsement by NASA Curation for approved materials or usage for advanced curatorial activities. NASA does not endorse nor promote any one particular product or company. References: [1] McCubbin F. M. et al. (2019) Space Science Reviews 215:A48. [2] Lewis, E.K. et. al (2024) LPSC LV, Abstract #2457.

Curation↗

Intramolecular 13 C isotope distributions of butane from natural gases

A single-step method allowing the measurement of 13 C intramolecular distribution of butane isomers (n- and i-butane) from natural gas samples was developed. The method builds up on the one that has been developed for propane, using on-line pyrolysis followed by isotope analysis of the pyrolytic fragments. The isotopic filiation between n-butane and its pyrolytic fragments was elucidated using samples spiked with 13 C on terminal positions. The isotopic filiation for i-butane could not be shown experimentally due to the lack of commercially available enriched i-butane. We thus used a recent model named Reaction Mechanism Generator (RMG) to assess the origin of the fragments arising from i-butane pyrolysis. Butanes from natural gas samples from the Carnarvon Basin (Australia) and the Arkoma Basin (USA) were analyzed. The results are consistent with a model for thermogenic natural gas generation and suggest that combined intramolecular isotope composition of propane and n-butane can be related to the gas maturity. In addition, the method allows the detection and shed light on the mechanism of n-butane and i-butane biodegradation in natural gas reservoirs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploratory tests of two strut fuel injectors for supersonic combustion

Results of supersonic mixing and combustion tests performed with two simple strut injector configurations, one with parallel injectors and one with perpendicular injectors, are presented and analyzed. Good agreement is obtained between static pressure measured on the duct wall downstream of the strut injectors and distributions obtained from one-dimensional calculations. Measured duct heat load agrees with results of the one-dimensional calculations for moderate amounts of reaction, but is underestimated when large separated regions occur near the injection location. For the parallel injection strut, good agreement is obtained between the shape of the injected fuel distribution inferred from gas sample measurements at the duct exit and the distribution calculated with a multiple-jet mixing theory. The overall fraction of injected fuel reacted in the multiple-jet calculation closely matches the amount of fuel reaction necessary to match static pressure with the one-dimensional calculation. Gas sample measurements with the perpendicular injection strut also give results consistent with the amount of fuel reaction in the one-dimensional calculation.

Anderson, G. Y.↗

Using SF 6 and Xe to Monitor Gas Migration Through Explosion-Generated Fracture Networks

Here we describe a field study where tracer gas was injected into a subsurface cavity created by a small chemical explosion beneath the water table. The main objective of the study is to compare the migration of sulfur hexafluoride (SF 6 ) and xenon (Xe) through an explosion-generated fracture network and to study the influence of ground water on gas transport. A mixture of tracer gases (50% of SF 6 and 50% of Xe) was injected on 31 October 2018 and gas sampling continued until 8 November 2018. We observe similar trends in SF 6 and Xe concentrations at four ground surface sampling sites. The changes in the SF 6 /Xe ratios with time show that more SF 6 than Xe is observed during the barometric pressure lows when the absolute measured concentrations are highest. Conversely, the ratio SF 6 /Xe is less than 1 during the high-pressure intervals when absolute measured concentrations are low. The results of the experiment suggest that during barometric pressure lows the tracer is migrating to the surface primarily by advective gas phase transport, whereas during barometric pressure highs, advection is suppressed and near-surface evaporation of interstitial pore fluid with tracer dissolved in it becomes more important. Thus, the results of the experiment show that the gas concentrations at the surface are controlled by the combined effects of the gas dissolution into pore water and the barometric pressure fluctuations.

58 GEOSCIENCES↗

Application of ion-induced nucleation mass spectrometry in the analysis of trace gases evolved from a polyimide film during the thermal curing stages

Trace gases evolved from a polyimide film during its thermal curing stages have been studied using ion-induced nucleation mass spectrometry. The technique involved exposing the test gas sample to a low energy beta source and recording the masses of the ion-induced molecular clusters formed in the reaction chamber. On the basis of the experimentally observed molecular cluster spectra, it has been concluded that the dominant trace component had a molecular weight of 87 atomic mass units. This component has been identified as a molecule of dimethylacetamide (DMAC) which had been used as a solvent in the preparation of the test polyimide specimen. This identification has been further confirmed by comparing the spectra of the test gas sample and the DMAC calibration sample obtained with a conventional mass spectrometer. The advantages of the ion-induced nucleation mass spectrometer versus the conventional mass spectrometer are discussed.

Smith, A. C.↗

Mars Molecular and Isotopic Analysis Research Study

Recently, the Martian atmosphere and surface constituents have become of great interest. The Viking in situ gas chromatograph mass spectrometer experiment contributed greatly to our knowledge of the composition of the Martian atmosphere. However, important questions remain such as the abundance of water on Mars. The Viking experiment employed solid reagents to enhance their carbon measurements. Techniques of chemical conversion using simple solid reagents have advanced considerably in the past 20 years. In this investigation we researched the advancements in techniques to reversibly adsorb and desorb water and focused on the techniques potentially useful for the temperatures and pressures on the Martian surface. During the granting period from June 15, 1998 to August 14, 1998, a literature study of the material appropriate for use in a chemical conversion device and the availability of these materials were undertaken. The focus of this investigation was searching for methods and materials potentially useful in enhancing the measurements of water. Three different methods were considered for the means to extract water from a given gas sample. These methods included adsorption in a desiccant, adsorption on a clean metal surface, and adsorption in a carbon molecular sieve or zeolite. Each method was evaluated with feasibility and reversibility in mind. By far the simplest and perhaps cheapest way to remove water from a gaseous sample is by means of a bulk desiccant. Desiccants are commercially available from many companies including those that supply chemicals. The main feature of a desiccant is its ability to rapidly bind or absorb water from the atmosphere. Calcium chloride, for example, is frequently incorporated into drying tubes by organic chemists when reactions require the absence of water. Other desiccants include sodium hydroxide, calcium hydride, and commercial products such as Drierite, available from Aldrich Chemical. The disadvantage to most desiccants is a direct consequence of what makes them so advantageous. Desiccants rapidly and strongly bind water, often reacting chemically with it. This strong binding makes reversibly desorbing the water from the desiccant very difficult. The third method by which to absorb water from a gas sample involves the use of molecular sieves of other ziolites.

Manning, Heidi L. K.↗

The Origin of Carbon-bearing Volatiles in Surprise Valley Hot Springs in the Great Basin: Carbon Isotope aud Water Chemistry Characterizations

There are numerous hydrothermal fields within the Great Basin of North America, some of which have been exploited for geothermal resources. With methane and other carbon-bearing compounds being observed, in some cases with high concentrations, however, their origins and formation conditions remain unknown. Thus, studying hydrothermal springs in this area provides us an opportunity to expand our knowledge of subsurface (bio)chemical processes that generate organic compounds in hydrothermal systems, and aid in future development and exploration of potential energy resources as well. While isotope measurement has long been used for recognition of their origins, there are several secondary processes that may generate variations in isotopic compositions: oxidation, re-equilibration of methane and other alkanes with CO2, mixing with compounds of other sources, etc. Therefore, in addition to isotopic analysis, other evidence, including water chemistry and rock compositions, are necessary to identify volatile compounds of different sources. Surprise Valley Hot Springs (SVHS, 41º32'N, 120º5'W), located in a typical basin and range province valley in northeastern California, is a terrestrial hydrothermal spring system of the Great Basin. Previous geophysical studies indicated the presence of clay-rich volcanic and sedimentary rocks of Tertiary age beneath the lava flows in late Tertiary and Quaternary. Water and gas samples were collected for a variety of chemical and isotope composition analyses, including in-situ pH, alkalinity, conductivity, oxidation reduction potential (ORP), major and trace elements, and C and H isotope measurements. Fluids issuing from SVHS can be classified as Na-(Cl)-SO4 type, with the major cation and anion being Na+ and SO4 2-, respectively. Thermodynamic calculation using ORP and major element data indicated that sulfate is the most dominant sulfur species, which is consistent with anion analysis results. Aquifer temperatures at depth estimated by both dissolved SiO2 and Na-K-Ca geothermometers are in the range of 125.0 to 135.4 oC, and higher than the values measured at orifices (77.3 to 90.0 oC). CO2 and homologs of straight chain alkanes (C1-C5) were identified in gas samples. Carbon isotope values of alkanes increase with carbon numbers. The 13C fractionation between CO2 and dissolved inorganic carbon suggests they are out of carbon isotope equilibrium. The hypothesis regarding the formation of carbon-bearing compounds in SVHS may involve two processes: 1) Under high heat flow conditions which are caused by regional faulting and crustal extension, original high molecular weight organic compounds (kerogens) in clay-rich rocks decomposed to generate methane and other alkane homologs. 2) The SVHS area is associated with outflow structures, and distant from the heat source. Anaerobic oxidation of methane (AOM) with sulfate at shallow depth (< 90 oC) is suggested as being responsible for the generation of CO2 in SVHS.

Fu, Qi↗

The Origin of Carbon-bearing Volatiles in Surprise Valley Hot Springs in the Great Basin: Carbon Isotope and Water Chemistry Characterizations

There are numerous hydrothermal fields within the Great Basin of North America, some of which have been exploited for geothermal resources. With methane and other carbon-bearing compounds being observed, in some cases with high concentrations, however, their origins and formation conditions remain unknown. Thus, studying hydrothermal springs in this area provides us an opportunity to expand our knowledge of subsurface (bio)chemical processes that generate organic compounds in hydrothermal systems, and aid in future development and exploration of potential energy resources as well. While isotope measurement has long been used for recognition of their origins, there are several secondary processes that may generate variations in isotopic compositions: oxidation, re-equilibration of methane and other alkanes with CO2, mixing with compounds of other sources, etc. Therefore, in addition to isotopic analysis, other evidence, including water chemistry and rock compositions, are necessary to identify volatile compounds of different sources. Surprise Valley Hot Springs (SVHS, 41 deg 32'N, 120 deg 5'W), located in a typical basin and range province valley in northeastern California, is a terrestrial hydrothermal spring system of the Great Basin. Previous geophysical studies indicated the presence of clay-rich volcanic and sedimentary rocks of Tertiary age beneath the lava flows in late Tertiary and Quaternary. Water and gas samples were collected for a variety of chemical and isotope composition analyses, including in-situ pH, alkalinity, conductivity, oxidation reduction potential (ORP), major and trace elements, and C and H isotope measurements. Fluids issuing from SVHS can be classified as Na-(Cl)-SO4 type, with the major cation and anion being Na+ and SO4(2-), respectively. Thermodynamic calculation using ORP and major element data indicated that sulfate is the most dominant sulfur species, which is consistent with anion analysis results. Aquifer temperatures at depth estimated by both dissolved SiO2 and Na-K-Ca geothermometers are in the range of 125.0 to 135.4 C, and higher than the values measured at orifices (77.3 to 90.0 C). CO2 and homologs of straight chain alkanes (C1-C5) were identified in gas samples. Carbon isotope values of alkanes increase with carbon numbers. The C-13 fractionation between CO2 and dissolved inorganic carbon suggests they are out of carbon isotope equilibrium. The hypothesis regarding the formation of carbon-bearing compounds in SVHS may involve two processes: 1) Under high heat flow conditions which are caused by regional faulting and crustal extension, original high molecular weight organic compounds (kerogens) in clay-rich rocks decomposed to generate methane and other alkane homologs. 2) The SVHS area is associated with outflow structures, and distant from the heat source. Anaerobic oxidation of methane (AOM) with sulfate at shallow depth (< 90 C) is suggested as being responsible for the generation of CO2 in SVHS.

Fu, Qi↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

A new approach to mass spectrometer measurements of thermospheric density

The gas sampling problem in satellite and high velocity probes was investigated by applying the theory of a drifting Maxwellian gas. A lens system using a free stream ion source was developed and experimentally evaluated over the pressure range of 0.00001 to 0.01 N/m sq (approx. 10 to the minus 7th power to 0.0001 torr). The source has high beam transparency, which minimizes gas-surface collisions within, or near, the ionization volume. It is shown that for high ion energy (60 eV), the extracted ion beam has an on-axis energy spread of less than 4 eV, and that 90 percent of the ions are within 2.5 deg of the beam axis. It is concluded that the molecular beam mass spectrometer concept, developed for gas density measurements in the upper atmosphere, substantially reduces gas-surface scattering and gas-surface reactions in the sample, and preserves the integrity of the gas sample during the analysis process. Studies show that both the Scout and Delta launch vehicles have adequate volume, control, velocity, and data acquisition capability necessary to obtain thermospheric number density in real time.

Melfi, L. T., Jr.↗

High pressure, high flow rate batch mixing apparatus for high throughput experiments

An automated, high pressure, high flow rate batch mixing apparatus has been designed and constructed for rapid, stable, and repeatable mixing of multiple gases and vapors. The apparatus operates as an intermittent batch mixer with cycles of topping off fresh mixture to maintain pressure in an accumulator tank until consumed in an experimental apparatus. At high duty cycles, the apparatus can also function at steady state. This style of mixing is suitable for experiments such as high repetition rate shock tubes and other devices with intermittent flow demands. It is compact and portable, facilitating use in locations such as synchrotron light sources. The entire apparatus is heated to permit the mixing of vapors from species with low volatilities. The apparatus is fully automated and runs for extended periods with the only intervention being to refresh reagent supplies. Here, the accuracy and repeatability of the apparatus were verified by periodic gas sampling and analysis with gas chromatography. Multi-component mixtures spanning a wide range of complexity, dilution, and volatility of constituents have been prepared. The compositions of the majority of the mixture were found to be stable over several filling cycles, repeatable, and with the proper calibration of set-point conditions, accurate. Challenges were encountered preparing a mixture from multi-component liquids, and potential solutions are discussed.

47 OTHER INSTRUMENTATION↗

In situ measurements of nitric oxide, water vapour and ozone from an aircraft

This paper describes flight tests of prototype instruments for the NASA global atmospheric sampling program (GASP). Three gas sampling instruments were included in the installation: (1) a chemiluminescent nitric oxide monitor; (2) an ultraviolet absorption ozone monitor; and (3) an aluminum oxide water vapor hygrometer. Results indicate the range and kind of variability in NO, H2O, and O3 that can be expected in routine tropospheric air sampling. They have also demonstrated the need for increasing instrument sensitivities, particularly in NO measurement.

Briehl, D. C.↗