Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas Receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hydrogen Mitigation Process Testing at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) developed and installed a process that addresses the issue of hydrogen buildup in Acciona's Nevada Solar One power plant. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure from 10 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. Laboratory testing at NREL showed that the sensor function had an accuracy of +/-7%, and the hydrogen extraction rate for separator function was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP completed installation and initial testing of a mitigation process at ASP's Nevada Solar One power plant in Boulder City, Nevada. In this paper, we report on the completed installation, initial testing, and plans to bring the process to full automation, so that it can be operated unattended on a daily schedule.

chemical elements↗

System and method for characterization of retrofit opportunities in building using data from communicating thermostats

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

System and method for characterization of retrofit opportunities in building using data from interval meters

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

System and method for characterization of air leakage in building using data from communicating thermostats and/or interval meters

Systems and methods for characterization of retrofit opportunities are described. Some embodiments are directed to methods for determining the air leakage rate of a building, and accordingly, for determining suitability of sealing of air leaks to improve the energy efficiency of a building. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter. To isolate the impact of air leakage, subsets of the HVAC runtime data at time intervals selected to have substantially the same conditions, but different wind speeds, may be computed.

Zeifman, Michael↗

Prototype Development, Testing, and Modeling for a Solar Light-Trapping Planar-Cavity Particle Receiver

Many applications for concentrating solar thermal power (CSP) technologies of high efficiency power cycles or thermochemical processes require higher operating temperatures and alternative heat transfer media. Inert solid particles for next-generation CSP and reactive gas and/or solid media for solar thermochemical processes are common options; however, these have significantly lower heat transfer capabilities than thermal oil, molten salt, or molten metal media. Conventional solar receivers operating temperatures >700 degrees Celsius face challenges including thermal performance and thermal-mechanical issues. To overcome these limitations, we have developed a novel light-trapping, planar-cavity receiver (LTPCR) that can heat solid-phase media within an enclosed receiver while maintaining a high aperture solar flux concentration for high efficiency. This paper presents progress on design, fabrication, and testing of a 100 kWt prototype receiver to demonstrate the LTPCR operability and its commercial feasibility.

14 SOLAR ENERGY↗

Impact of Biofuel Blends on Black Carbon Emissions from a Gas Turbine Engine

With a view towards renewable feedstock while decreasing the CO2 footprint associated with jet travel, biofuels are receiving increasing interest. Presented here is an overview of non-volatile particulate matter (nvPM) emissions, i.e. “soot” as gauged by varied TEM analyses for a J-85 turbojet fueled with Jet-A as well as with blends of Jet-A using Camelina biofuel. A unifying explanation is provided encompassing fuels and spanning length scales across three orders of magnitude. The variation of primary particle size, aggregate size and nanostructure are analyzed as a function of biofuel blend across range of engine thrust levels. The postulate is based on where fuels start along the soot formation pathway. Increasing biofuel content lowers aromatic concentration while placing increasing dependence upon fuel pyrolysis reactions to form the requisite concentration of aromatics for particle inception and growth. The required “kinetic” time for pyrolysis reactions to produce benzene and multi-ring PAHs allows increased fuel-air mixing by turbulence, diluting the fuel-rich soot-forming regions, effectively lowering their equivalence ratio. With a lower precursor concentration, particle inception is slowed, the resulting concentration of primary particles is lowered and smaller aggregates. The lower equivalence ratio also results in smaller primary particles given the lower concentration of growth species.

Kumal, Raju R.↗

A reduced-order modeling of a tubular solar reactor for long duration thermochemical energy storage

The storage of solar energy in a solid form, referred to as a “solar fuel”, can be achieved through a process known as endothermic solar thermochemistry. This process transforms the absorbed solar energy into a stable and retrievable form that can be stored for extended periods of time. This paper presents a low–order heat transfer model of a counter–current tubular falling bed reactor designed to produce thermally reduced magnesium manganese oxide pellets for long duration thermochemical energy storage. The energy required for the endothermic reduction was supplied by concentrated solar energy or renewable electricity via indirect heating of the gas and solid reactants flowing in a ceramic tube. The counter-current gas flow enhances the mixing of the solid particles with the heat recuperation zone, allowing the gas and particles to enter and exit the tubular reactor close to room temperature. Further, the reactor was vertically oriented and was heated circumferentially by an adjustable level heat flux along a finite segment of its length. The temperature distribution of the reactor in response to transient changes along the tube was modeled by considering conduction, convection, and radiation heat transfer. Governing equations for the heat transfer model were solved by discretizing the reactor tube into a finite number of control volumes and using an energy balance for the heat exchange between the reactor wall, gas, and particles within the control volume. The energy absorbed during this endothermic reaction was modeled numerically by fitting the data of the chemical conversion rate with the corresponding temperature of particles in the heating zone. The numerical model has been experimentally validated using a reactor prototype made of a 121.92 cm alumina tube heated by a 7kW electric tube–furnace. The alumina tube receives magnesium manganese oxide pellets of 3.66±0.516 mm in diameter from the top, and a counter–current gas flow from the bottom. The reactor wall temperature was monitored by six thermocouples installed along the reactor tube length. The experimental procedure was numerically simulated, and the temperature variation along the reactor tube was compared with a matrix of experimental runs for a range of particles mass flowrates (0.75–1.25g/s) and corresponding gas flowrates (36–65 SLPM). The reactor system was heated gradually from room temperature to a steady state temperature of 1673K, and then cooled down to room temperature. The heating and cooling processes were simulated, and the numerical and experimental results were compared throughout processes. The numerical model showed similar trends to the experimental results, with an error of 0.69 to 7.9% for the particle inlet and 0.7 to 7.9% for the gas inlet during steady-state operation. The proposed numerical model can be implemented as a simplified physical model to design a feedback control system to regulate reactor temperature.

14 SOLAR ENERGY↗

Prototype Development, Testing, and Modeling for a Solar Light-Trapping Planar-Cavity Particle Receiver (LTPCR)

Many applications for concentrating solar thermal power (CSP) technologies of high efficiency power cycles or thermochemical processes require higher operating temperatures and alternative heat transfer media. Inert solid particles for next-generation CSP and reactive gas and/or solid media for solar thermochemical processes are common options; however, these have significantly lower heat transfer capabilities than thermal oil, molten salt, or molten metal media. Conventional solar receivers operating temperatures >700 degrees Celsius face challenges including thermal performance and thermal-mechanical issues. To overcome these limitations, we have developed a novel light-trapping, planar-cavity receiver (LTPCR) that can heat solid-phase media within an enclosed receiver while maintaining a high aperture solar flux concentration for high efficiency. This paper presents progress on design, fabrication, and testing of a 100 kWt prototype receiver to demonstrate the LTPCR operability and its commercial feasibility.

14 SOLAR ENERGY↗

Illinois Compressed Air Energy Storage

Compressed Air Storage Energy (CAES) is one of the few mid- technology readiness level (TRL) energy storage technologies that can address the long-duration infrastructure needed for dealing with variable electric output from renewable energy sources and be reliable backup source for replacing natural gas during supply interruptions. In CAES the goal is to capture and store compressed air in subsurface sedimentary strata when off-peak power is available, or there is a need for grid balancing. The stored high-pressure air is returned to the surface and used to power turbines during reductions in either renewable energy or supply issues with fossil fuels. The Illinois CAES project evaluates the feasibility of capturing surplus electrical energy from renewable sources and off-peak energy at a fossil fuel power plant at the University of Illinois Urbana - Champaign (UIUC) campus. The UIUC Abbott Power Plant uses natural gas and coal to generate electricity (capacity: 35 MWe by coal and 49 MWe by NG). UIUC receives additional electricity from on campus solar farm, and off-campus wind farm. Also, UIUC offsets electricity usage by integrating geothermal energy systems into building heating Also, UIUC offsets steam, hot and chilled water usage by integrating geothermal energy systems into building heating and cooling systems. Furthermore, the two UIUC solar farms (Solar Farm 1 is 21 acres and Solar Farm 2 is 54 acres) to generate 4.68 megawatts (MW) and 12.1 MW, respectively. Campus receives 8.6% of the wind-generated electricity from the Rail Splitter Wind Farm. The project objectives were to design an integrated system to 1) capture surplus electrical energy from renewable sources and the Abbott Power Plant using a CAES system, 2) store both the compressed air and the thermal heat generated by compression in the subsurface as part of an adiabatic system, 3) simulate the movement of the air and heat in the subsurface, 4) recover the compressed air and stored thermal heat to rotate turbine generators during sustained interruption due to weather events or fossil fuel disruptions.

03 NATURAL GAS↗

Comparison of direct and CO 2 -oxidative dehydrogenation of propane

Propane dehydrogenation to propylene has received increasing attention due to the fast growth in propylene demand and the exploration of shale gas containing propane. Direct dehydrogenation of propane (DDHP) offers high propylene selectivity but is limited by quick deactivation due to coke formation. CO 2 -assisted oxidative dehydrogenation of propane (CO 2 -ODHP) can consume CO 2 and meanwhile reduce coke deposition via the reverse Boudouard reaction. Here in the current review, direct and CO 2 -assisted dehydrogenation of propane has been compared from three aspects: reaction mechanisms, catalyst compositions, and CO 2 footprint analysis. As the average CO 2 emissions from electricity generation decrease due to the utilization of renewable energy, CO 2 -ODHP potentially leads to a net-negative CO 2 footprint while DDHP cannot.

58 GEOSCIENCES↗

Comparative life cycle analysis on ethylene production from electrocatalytic reduction of carbon dioxide

Ethylene is one of the largest greenhouse gas emitters and the most diversly used commodity chemicals globally. Electrocatalytic reduction of CO 2 to ethylene received great attention from the research society to decarbonize the ethylene production. Here, in this study, a life-cycle analysis is conducted using the Greenhouse Gases, Regulated Emissions, and Energy use in Technologies (GREET) model on the three electrocatalytic CO 2 -reduction pathways (or “e-ethylene” pathways): i) cascade conversion via carbon monoxide intermediate; ii) single-step conversion in membrane electrode assembly (MEA); and iii) single-step conversion in alkaline flow cell. The results showed that the electricity consumption is the lowest for the cascade pathway (164 MJ/kg), thus resulting in the lowest cradle-to-gate carbon intensity [18 kgCO 2 e/kg with United States (US) average grid)] among the three pathways followed by the single-step MEA (32 kgCO 2 e/kg) and then by the single-step alkaline (56 kgCO 2 e/kg). However, all three e-ethylene pathways were significantly more carbon-intensive than their fossil-based counterpart (1.1 kgCO 2 e/kg) due to their excessive energy consumption with the current state of technology. With renewable electricity, all three pathways yielded negative carbon intensity: from -3.1 kgCO 2 e/kg to -1.6 kgCO 2 e/kg depending on the source of CO 2 . The threshold carbon intensity of electricity (TCIE), defined as the upper bound of the carbon intensity of electricity to achieve lower carbon intensity for e-ethylene compared to fossil-based ethylene, is calculated for both current and future state of e-ethylene technologies. The cascade pathway had the highest TCIE out of the three e-ethylene pathways for both current (92 gCO 2 e/kWh) and future (124 gCO 2 e/kWh) state of technologies. However, the carbon intensity of average US grid (i.e., 467 and 303 gCO 2 e/kWh for current and future projections) were higher than the TCIEs of the corresponding timeline. Thus, reducing electricity requirement for e-ethylene pathways and bringing low-carbon generation mix in the United States (US) grid faster than the current projection are both essential to decarbonize ethylene and its downstream chemicals/polymers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Irradiation Vehicles for Evaluating SiC/SiC Cladding Bowing Under Neutron Flux Gradients

Silicon carbide fiber–reinforced silicon carbide matrix (SiC/SiC) composites are among the most promising candidates for long term accident-tolerant nuclear fuel cladding. A key challenge related to their deployment is lateral bowing caused by differential radiation-induced swelling under dose or temperature gradients, which could obstruct coolant flow or interfere with control rod/blade movements. Although previous modeling efforts have predicted bowing behavior in light-water reactor (LWR) environments, experimental validation remains limited, especially at prototypic LWR temperatures. This study addresses that gap by irradiating six reduced-length SiC/SiC cladding tubes (~600 mm) in the High Flux Isotope Reactor (HFIR) at ~300°C, which is representative of LWR conditions. The tubes will be housed in a sealed vessel with an inert gas gap to maintain target temperatures and prevent direct coolant contact. Arranged in three pairs, each set will receive a different radiation dose (low, medium, high), with the central pair receiving ~0.1 displacements per atom (dpa)—the expected dose for peak bowing. The experiment will determine the dose-dependent bowing behavior and validate predictive finite element models. In this work, the tubes are freely suspended from pins to allow for unconstrained bowing; however, we present a concept for introducing localized constraints to represent grid spacer effects. Post-irradiation examination will include swelling measurements and profilometry to assess bowing and compare the results with model predictions. This work aims to confirm the conditions under which maximum bowing occurs so as to improve the reliability of SiC/SiC performance models in nuclear applications.

Russell, Nick [ORNL] (ORCID:0000000296099820)↗

End-of-Life Evaluation of Compressed Natural Gas Vehicle Fuel Tanks

This study evaluated the structural integrity of Type III and Type IV CNG fuel tanks from the Los Angeles (LA) County Metropolitan Transportation Authority to characterize the fuel tank conditions after experiencing a full service life of 15 years in transit bus application. The data produced provide insight about the condition of the CNG fuel tanks at the conclusion of their defined EOL and potential risks of continued operation of the CNG vehicle without replacement of the expired fuel tanks. In addition to physical testing performed on the fuel tanks, a nondestructive evaluation of modal acoustic emission (MAE) was utilized to assess the structural integrity of the tanks. The CNG fuel tanks were evaluated in their received condition and after experiencing artificial damage. The MAE results were then compared to visual inspection results of the procedures defined in the Compressed Gas Association’s (CGA’s) C-6.2 and C-6.4 standards (Compressed Gas Association 2013; 2012) to better understand the effectiveness of the visual inspection and potential safety risks of continued use of the tanks.

03 NATURAL GAS↗

Calculating the Effects of Solids Input and Removal as a Temperature Control in the Advanced Scale Up Reactor Experiment (ASURE) Facility at NETL Using Aspen

The Advanced Scale Up Reactor Experiment (ASURE) facility at NETL is being designed to be a fuel-flexible multi-purpose reactor that can be used for pyrolysis/gasification or evaluation of other high pressure “circulating fluidized bed” (CFB) chemical processes. The initial system design calculations for pyrolysis/gasification are presented in this work showing the expected performance of the ASURE facility when used as a biomass conversion reactor. Several other areas of application include gasification of any carbonaceous fuel including biomass, coal, plastics, and other waste materials. The reactor can therefore be used to produce SYNGAS of various compositions and hydrogen as well as other high value chemicals resulting from a typical tuned gasification process. This paper discusses an ASPEN model of the facility, focusing on the riser of the CFB reactor and the solids recirculation loop. The ASPEN model divides the riser into two sections. A bottom section which receives ash, char and sand which have been recirculated from a return loop. In this section an inert fluidization gas, (N2 or CO2), is introduced which acts as the primary mover of the solids through the system. The bottom section is equipped with a restricted air feed so that the recirculated char can be partially oxidized. This oxidation process along with the inventory of recirculating sand are used to effectively control the temperature in the following two chemical conversion sections of the reactor which are the pyrolysis zone followed by a tar cracking zone. Fresh fuel is added to the pyrolysis zone and undergoes drying and devolatilization. The products ash, char, volatile matter, and water vapor exit the pyrolysis zone and enter the reaction block for tar cracking. Steam and CO2 gasification reactions will be incorporated into the tar cracking zone, however at the design operating temperature, conversion from these reactions is expected to be essentially zero. The unit when completed in 2026 will test mixtures of biomass, plastics, and waste coal. This presentation discusses the basic ASPEN engineering design model for this project and provides preliminary sensitivity studies to determine how the various parts of the reactor will perform.

ASSURE↗

Calculating the Effects of Solids Input and Removal as a Temperature Control in the Advanced Scale Up Reactor Experiment (ASURE) Facility at NETL Using Aspen

The Advanced Scale Up Reactor Experiment (ASURE) facility at NETL is being designed to be a fuel-flexible multi-purpose reactor that can be used for pyrolysis/gasification or evaluation of other high pressure “circulating fluidized bed” (CFB) chemical processes. The initial system design calculations for pyrolysis/gasification are presented in this work showing the expected performance of the ASURE facility when used as a biomass conversion reactor. Several other areas of application include gasification of any carbonaceous fuel including biomass, coal, plastics, and other waste materials. The reactor can therefore be used to produce SYNGAS of various compositions and hydrogen as well as other high value chemicals resulting from a typical tuned gasification process. This paper discusses an ASPEN model of the facility, focusing on the riser of the CFB reactor and the solids recirculation loop. The ASPEN model divides the riser into two sections. A bottom section which receives ash, char and sand which have been recirculated from a return loop. In this section an inert fluidization gas, (N2 or CO2), is introduced which acts as the primary mover of the solids through the system. The bottom section is equipped with a restricted air feed so that the recirculated char can be partially oxidized. This oxidation process along with the inventory of recirculating sand are used to effectively control the temperature in the following two chemical conversion sections of the reactor which are the pyrolysis zone followed by a tar cracking zone. Fresh fuel is added to the pyrolysis zone and undergoes drying and devolatilization. The products ash, char, volatile matter, and water vapor exit the pyrolysis zone and enter the reaction block for tar cracking. Steam and CO2 gasification reactions will be incorporated into the tar cracking zone, however at the design operating temperature, conversion from these reactions is expected to be essentially zero. The unit when completed in 2026 will test mixtures of biomass, plastics, and waste coal. This paper presents the basic ASPEN engineering design model for this project and provides preliminary sensitivity studies to determine how the various parts of the reactor will perform.

ASSURE↗

Techno-economic Analysis of the Cryogenic Flux Capacitor Compared to Other forms of Hydrogen Production and Storage

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. The hydrogens storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 49% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at equivalent densities. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce GH2. The TEA compares pure hydrogen burning in a combined cycle gas turbine (CCGT) to hydrogen fuel cells with an overall net power output of 650 MW. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity is developed based on the capital cost and operating cost of the systems. Sensitivities are discussed around the cost of natural gas, ranging from 1.93 USD per MMBTU to 6.75 USD per MMBTU, and carbon dioxide disposal, ranging from 7 USD per tonne to 10 USD per tonne. For comparison to the conventional CCGT baseline, a baseload scenario is adopted with 85% capacity factor. The results of the study show that onsite hydrogen generation from SMR is about 1 to 3 USD per kg over the life of the plant and the PV hydrogen production produces at 4 to 5 USD per kg. The cost of storage for CFC is compared to other systems, including high-pressure GH2 and atmospheric LH2. The system is shown to provide the lowest costs for all these options at the grid scale, due to its higher capacity than high-pressure GH2 and ability to operate at 80K, receiving refrigeration from liquid nitrogen systems reducing capital and operating costs when compared LH2 storage systems. SMR is competitive with CCGT at the gas prices, both of which have lower LCOE than the PV system. When accounting for variability in gas prices, the PV and electrolyzer system is less sensitive to these changes and provides the lowest LCOE across the whole range.

08 HYDROGEN↗

Experimental investigation of Multi-Mode heat transfer to a Free-Falling dilute particle cloud in a heated vertical tube

The development of dilute particle heat exchangers and reactors for advanced energy systems requires an understanding of the multi-mode heat transfer from a heated wall to falling particles. This study presents experimental results of the overall heat transfer coefficient for a free-falling, dilute flow of particles with solid volume fraction from 0.0005 to 0.006 corresponding to feed rates from 3.7 kg s -1 m -2 to 44 kg s -1 m -2 in a vertical, heated tube containing quiescent air at atmospheric pressure. Tube wall temperatures are varied between 300°C to 900°C while keeping the particle inlet temperature constant. The experimental results show that the overall heat transfer coefficient is a strong function of particle feed rate and surface temperature. Good agreement was obtained with prior studies conducted at comparable temperatures but lower particle feed rates (< 4 kg m -2 s -1 ). The established correlations for particle-to-wall radiation and particle-to-gas convection were used to estimate the wall-to-gas convective contribution from the measured overall heat transfer coefficient. The experimental results indicated a 4 to 6 times improvement in the wall convection in the solid-gas mixture compared to that expected from natural convection in a single-phase gas. Furthermore, the data presented here are applicable to characterize heat transfer in dilute particle heat exchangers, furnaces, and solar receivers.

14 SOLAR ENERGY↗

The need to consider regional supply chains and water usage in H 2 –steel transition

The iron and steel industry is one of the largest contributors to U.S. and global greenhouse gas emissions. Hydrogen can act as a promising reducing agent and clean energy carrier to decarbonize this sector, and has received significant attention in terms of process modelling, techno-economic analysis, and life cycle assessment in recent years. Policy incentives, hydrogen storage and transportation, and water stress levels are key factors that require significantly more consideration in order to realize hydrogen’s potential to decarbonize this industry. This review demonstrates the need for a systematic understanding and critical assessment of these areas, and their profound impacts on the decarbonization of the iron and steel sector. Furthermore, hydrogen and water supply face competition from other hard-to-decarbonize sectors, which should be considered on national and regional levels. Lastly, future research should also consider the impact of other environmental factors and hydrogen leak when deploying hydrogen at scale for industrial decarbonization.

Green steel↗