Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRATINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Aberrations of varied line-space grazing incidence gratings in converging light beams

Analyses of the imaging properties of several designs for varied-line space gratings in converging beams of light in grazing-incidence spectrometers are presented. An explicit model is defined for the case of a plane-reflection grating intercepting light that converges and is reflected to a stigmatic point associated with the zero-order image of the grating. Smooth spatial variation of the grating constant then permits aberration correction. The aberrations are expressed as polynomials in the grating lens coordinates using power series expansions. Application of the model is illustrated in terms of aberrations experienced with the short wavelength spectrometer on the EUVE satellite. Attention is given to straight and parallel in-plane grooves, curved groove in-plane designs and off-plane grooves. Aberrations due to dispersions and misalignment are also considered.

Hettrick, M. C.↗

The high energy transmission grating spectrometer for AXAF

Attention is given to a high energy transmission grating spectrometer that operates over the range 0.4-8 keV, giving resolving powers of 100-1000 and effective areas of 10-200 sq cm. The instrument, which is part of the MIT high resolution X-ray spectroscopy investigation, consists of a single array of grating facets of two types: medium energy gratings of 0.6-micron period, 0.5-micron thick silver mounted behind the outer three AXAF mirrors, and high energy gratings of 0.2-micron period, 1.0-micron thick gold mounted behind the inner three mirrors. The gratings are oriented so as to correct for coma and so that the medium and high energy spectra form a shallow 'X' at the AXAF focal plane. Likely targets include normal stars, binary X-ray sources, active galactic nuclei and quasars. The HETGS can also be used to give moderate resolution spectra of slightly extended sources and monochromatic images of sources with strong lines, such as supernova remnants in nearby galaxies.

Canizares, C. R.↗

The evaluation of a deformable diffraction grating for a stigmatic EUV spectroheliometer

A high-efficiency, extreme ultraviolet (EUV) imaging spectrometer is constructed and tested. The spectrometer employs a concave toroidal grating illuminated at normal incidence in a Rowland circle mounting and has only one reflecting surface. The toroidal grating has been fabricated by a new technique employing an elastically-deformable sub-master grating replicated in a spherical form and then mechanically distorted to produce the desired aspect ratio of the toroidal surface for stigmatic imaging over the selected wavelength range. The fixed toroidal grating used in the spectrometer is then replicated from this surface. Photographic tests and initial photoelectric tests with a two-dimensional, pulse-counting detector system verify the image quality of the toroidal grating at wavelengths near 600 A. The results of these tests and the basic designs of two instruments which could employ the imaging spectrometer for astrophysical investigations in space are described; i.e., a high-resolution EUV spectroheliometer for studies of the solar chromosphere, transition region, and corona; and an EUV spectroscopic telescope for studies of non-solar objects.

Timothy, J. G.↗

Transmission X-ray diffraction grating alignment using a photoelastic modulator

A high-resolution alignment technique which utilizes the partial polarization property of fine period transmission gratings has been developed. It is especially useful when the grating period is sufficiently small so that there are no visible diffracted orders. This technique uses a photoelastic modulator (PEM) to produce an intensity signal that is proportional to the sine of twice the angle between the grating lines and the PEM crystal axis. The experimentally demonstrated resolution of this technique on 200-nm period gold transmission gratings is better than 1 arc sec. This technique was developed to align X-ray transmission gratings for spectroscopy and interferometry applications.

Anderson, Erik H.↗

Small blaze angle gratings with various surface treatments for use in the extreme ultraviolet

Three replica gratings made from a single master, including two epoxy-overcoated gratings with different thicknesses of gold and one grating replicated directly in gold, were studied by measuring and comparing the performances of the gratings in EUV light at grazing incidence angles. The results show that, in situations which require a very low grazing angle, high-quality, mechanically ruled straight groove gratings provide good efficiency and uniform blaze independent of coating thickness up to 1000 A. However, the technique of direct replication in the surface material seems to result in substantially more light scattering and does not seem to have other obvious advantages.

Miller, Anne↗

X-ray/VUV transmission gratings for astrophysical and laboratory applications

This paper describes the techniques used to fabricate deep-submicron-period transmission gratings for astrophysical and laboratory applications, with special attention given to the major steps involved in the transmission grating fabrication. These include the holographic lithography procedure used to pattern the master transmission grating, the fabrication of X-ray mask, the X-ray lithography step used to transfer the X-ray mask pattern into a substrate, and the electroplating of the substrate to form the final grating pattern. The various ways in which transmission gratings can be used in X-ray and VUV spectroscopy are discussed together with some examples of experiments reported in the literature.

Schattenburg, M. L.↗

On the convergence of the coupled-wave approach for lamellar diffraction gratings

Among the many existing rigorous methods for analyzing diffraction of electromagnetic waves by diffraction gratings, the coupled-wave approach stands out because of its versatility and simplicity. It can be applied to volume gratings and surface relief gratings, and its numerical implementation is much simpler than others. In addition, its predictions were experimentally validated in several cases. These facts explain the popularity of the coupled-wave approach among many optical engineers in the field of diffractive optics. However, a comprehensive analysis of the convergence of the model predictions has never been presented, although several authors have recently reported convergence difficulties with the model when it is used for metallic gratings in TM polarization. Herein, three points are made: (1) in the TM case, the coupled-wave approach converges much slower than the modal approach of Botten et al; (2) the slow convergence is caused by the use of Fourier expansions for the permittivity and the fields in the grating region; and (3) is manifested by the slow convergence of the eigenvalues and the associated modal fields. The reader is assumed to be familiar with the mathematical formulations of the coupled-wave approach and the modal approach.

Li, Lifeng↗

Rocket flight of a multilayer coated high-density EUV toroidal grating

A multilayer coated high density toroidal grating was flown on a sounding rocket experiment in the Solar EUV Rocket Telescope and Spectrograph (SERTS) instrument. To our knowledge this is the first space flight of a multilayer coated grating. Pre-flight performance evaluation showed that the application of a 10-layer Ir/Si multilayer coating to the 3600 l/mm blazed toroidal replica grating produced a factor of 9 enhancement in peak efficiency near the design wavelength around 30 nm in first order over the standard gold coating, with a measured EUV efficiency that peaked at 3.3 percent. In addition, the grating's spectral resolution of better than 5000 was maintained. The region of enhanced grating efficiency due to the multilayer coating is clearly evident in the flight data. Within the bandpass of the multilayer coating, the recorded film densities were roughly equivalent to those obtained with a factor of six longer exposure on the previous flight of the SERTS instrument.

Keski-Kuha, Ritva A. M.↗

Deformed ellipsoidal gratings for far-ultraviolet spectrographs - Analytic optimization

Analytic formulas are developed for the semiaxes and for the deformation coefficients of a deformed ellipsoidal grating that minimize aberrations over a given spectral range. These include the Rowland circle mount and quasi-Rowland circle mounts, as required for systems that combine spectra from multiple gratings on a common detector. It is also shown that the necessary condition for a holographic grating to give a better performance over a conventional grating is the use of a convergent beam and a divergent beam for the recording. Examples applicable to the Far-Ultraviolet Spectroscopic Explorer are given. The light-path function for a deformed ellipsoidal holographic grating is also presented.

Content, David↗

Fiber Grating Coupled Light Source Capable of Tunable, Single Frequency Operation

Fiber Bragg grating coupled light sources can achieve tunable single-frequency (single axial and lateral spatial mode) operation by correcting for a quadratic phase variation in the lateral dimension using an aperture stop. The output of a quasi-monochromatic light source such as a Fabry Perot laser diode is astigmatic. As a consequence of the astigmatism, coupling geometrics that accommodate the transverse numerical aperture of the laser are defocused in the lateral dimension, even for apsherical optics. The mismatch produces the quadratic phase variation in the feedback along the lateral axis at the facet of the laser that excites lateral modes of higher order than the TM 00 . Because the instability entails excitation of higher order lateral submodes, single frequency operation also is accomplished by using fiber Bragg gratings whose bandwidth is narrower than the submode spacing. This technique is particularly pertinent to the use of lensed fiber gratings in lieu of discrete coupling optics. Stable device operation requires overall phase match between the fed-back signal and the laser output. The fiber Bragg grating acts as a phase-preserving mirror when the Bragg condition is met precisely. The phase-match condition is maintained throughout the fiber tuning range by matching the Fabry-Perot axial mode wavelength to the passband center wavelength of the Bragg grating.

Michael A Krainak↗

Fabrication of Extremely Short Length Fiber Bragg Gratings for Sensor Applications

A new technique and a physical model for writing extremely short length Bragg gratings in optical fibers have been developed. The model describes the effects of diffraction on the spatial spectra and therefore, the wavelength spectra of the Bragg gratings. Using an interferometric technique and a variable aperture, short gratings of various lengths and center wavelengths were written in optical fibers. By selecting the related parameters, the Bragg gratings with typical length of several hundred microns and bandwidth of several nanometers can be obtained. These short gratings can be apodized with selected diffraction patterns and hence their broadband spectra have a well-defined bell shape. They are suitable for use as miniaturized distributed strain sensors, which have broad applications to aerospace research and industry as well.

Wu, Meng-Chou↗

All-Optical Micro Motors Based on Moving Gratings in Photosensitive Media

This research effort was a feasibility study of the concept of an all-optical micro motor with a rotor driven by a traveling wave. The wave was a result of a photo induced surface deformation of a photosensitive material produced by a traveling holographic grating. Two phases modulated coherent optical beams were used to generate the grating in two types of photosensitive materials. The materials that were studied were photorefractive crystals and thin polymer films. Theoretical studies were performed on lithium niobate giving predictions of deformations of the order of nanometers. The experimental deformation size was also on the order of nanometers. The deformations were deep enough to provide conditions for the implementation of the all-optical motor using lithium niobate. We also were able to align micron-size dielectric particles along the holographic gratings by means of the periodic electric forces generated by the grating. These forces can also move the particles along the surface if the grating is moving. We then turned our attention on thin films and obtained a deformation visible on the order of 100 microns. An experimental breadboard demonstration of a prototype was done in the summer of 2001 at Glenn Research Center (GRC). The demonstration included the movement of clocks mechanical workings by an optically driven motor based on a polymer film. The application of this technology can be adapted to government as well as industrial uses. One such project is to make a chemical sensor for the detection of hazardous chemicals. The thin polymer film is highly suited for this purpose since a marker dye could be easily placed on the film in order to detect chemical compounds. This system could be a self-regulating chemical monitoring system used on launches of the space shuttle or locations where hazardous chemicals are present. The project provided support for two black minority graduate students targeting MS and PhD degrees in Applied Optics.

Adamovsky, Gregory↗

Using Dual-wavelength Fiber Bragg Gratings for Temperature and Strain Sensing at Cryogenic Temperature

By using dual-wavelength fiber-optic Bragg gratings, a new technique has been developed for sensing both temperature and strain simultaneously in cryogenic temperature range. Two Bragg gratings with different wavelengths were inscribed at the same location in an optical fiber to form a dual-wavelength sensor. By measuring the wavelength shifts that resulted from the fiber being subjected to different temperatures and strains, the wavelength-dependent thermo-optic coefficients and photoelastic coefficients of the fiber were determined. These coefficients were used to construct the elements of the K matrix, which enables to determine inversely the strain and temperature changes by measuring the wavelength shifts of the dual-wavelength Bragg grating. In this study, measurements were made over the temperature range from room temperature down to about 10 K, addressing much of the low temperature range of cryogenic tanks. A structure transition of the optical fiber during the temperature change was found from about 70 K to 140 K. This transition caused splitting of the waveforms characterizing the Bragg gratings, and the determination of wavelength shifts was consequently complicated. Several alternatives are proposed to resolve this problem. The effectiveness and sensitivities of these measurements in different temperature ranges are discussed. The separation of two wavelengths for the dual-wavelength Bragg grating has been widened to increase the sensitivities of measurement; however, this separation can still be covered in the scanning range from single scanning laser.

Wu, Meng-Chou↗

Imaging spectrometer/camera having convex grating

An imaging spectrometer has fore-optics coupled to a spectral resolving system with an entrance slit extending in a first direction at an imaging location of the fore-optics for receiving the image, a convex diffraction grating for separating the image into a plurality of spectra of predetermined wavelength ranges; a spectrometer array for detecting the spectra; and at least one concave sperical mirror concentric with the diffraction grating for relaying the image from the entrance slit to the diffraction grating and from the diffraction grating to the spectrometer array. In one embodiment, the spectrometer is configured in a lateral mode in which the entrance slit and the spectrometer array are displaced laterally on opposite sides of the diffraction grating in a second direction substantially perpendicular to the first direction. In another embodiment, the spectrometer is combined with a polychromatic imaging camera array disposed adjacent said entrance slit for recording said image.

Reininger, Francis M.↗

Mirror-grating tuning arrangement for high resolution lasers

A tuning arrangement (10) for a tunable laser comprises a single holographic grating (12) and two flat surface reflective mirrors (13 and 14). The beam (15) from the laser cavity is incident on the grating at a grazing angle for optimum beam expansion. The diffracted beam propogates from the grating to the first mirror (13), therefrom to the second mirror (14) and is reflected at the Littrow angle to the grating, whereat it is diffracted a second time and returned to the second mirror (14) for reflection to the first mirror (13). Therefrom it is reflected back to the grating. After undergoing a third diffraction it is directed back into the cavity for further amplification.

McDermid, Iain S.↗

Fiber-Optic Gratings for Lidar Measurements of Water Vapor

Narrow-band filters in the form of phase-shifted Fabry-Perot Bragg gratings incorporated into optical fibers are being developed for differential-absorption lidar (DIAL) instruments used to measure concentrations of atmospheric water vapor. The basic idea is to measure the relative amounts of pulsed laser light scattered from the atmosphere at two nearly equal wavelengths, one of which coincides with an absorption spectral peak of water molecules and the other corresponding to no water vapor absorption. As part of the DIAL measurement process, the scattered light is made to pass through a filter on the way to a photodetector. Omitting other details of DIAL for the sake of brevity, what is required of the filter is to provide a stop band that: Surrounds the water-vapor spectral absorption peaks at a wavelength of 946 nm, Has a spectral width of at least a couple of nanometers, Contains a pass band preferably no wider than necessary to accommodate the 946.0003-nm-wavelength water vapor absorption peak [which has 8.47 pm full width at half maximum (FWHM)], and Contains another pass band at the slightly shorter wavelength of 945.9 nm, where there is scattering of light from aerosol particles but no absorption by water molecules. Whereas filters used heretofore in DIAL have had bandwidths of =300 pm, recent progress in the art of fiber-optic Bragg-grating filters has made it feasible to reduce bandwidths to less than or equal to 20 pm and thereby to reduce background noise. Another benefit of substituting fiber-optic Bragg-grating filters for those now in use would be significant reductions in the weights of DIAL instruments. Yet another advantage of fiber-optic Bragg-grating filters is that their transmission spectra can be shifted to longer wavelengths by heating or stretching: hence, it is envisioned that future DIAL instruments would contain devices for fine adjustment of transmission wavelengths through stretching or heating of fiber-optic Bragg-grating filters nominally designed and fabricated to have transmission wavelengths that, in the absence of stretching, would be slightly too short.

Vann, Leila B.↗

Micro Ring Grating Spectrometer with Adjustable Aperture

A spectrometer includes a micro-ring grating device having coaxially-aligned ring gratings for diffracting incident light onto a target focal point, a detection device for detecting light intensity, one or more actuators, and an adjustable aperture device defining a circular aperture. The aperture circumscribes a target focal point, and directs a light to the detection device. The aperture device is selectively adjustable using the actuators to select a portion of a frequency band for transmission to the detection device. A method of detecting intensity of a selected band of incident light includes directing incident light onto coaxially-aligned ring gratings of a micro-ring grating device, and diffracting the selected band onto a target focal point using the ring gratings. The method includes using an actuator to adjust an aperture device and pass a selected portion of the frequency band to a detection device for measuring the intensity of the selected portion.

Park, Yeonjoon↗

Reflective long period grating

A reflection mode sensor system may include an optical fiber core and an optical fiber cladding. A first long period grating (LPG) may be positioned along the optical fiber core having a first grating period, a second LPG may be positioned along the optical fiber core having a second grating period, and a third LPG may be positioned along the optical fiber core having a third grating period. The grating periods may enable sensing of multiple parameters simultaneously. A metal coating may be applied to an end facet of the combined optical fiber core and optical fiber cladding. The metal coating may also cover a side surface of the optical fiber cladding along a length from the end facet. The metal coating may include a paste applied to the optical fiber core and the optical fiber cladding, where the paste has been cured, and includes a metal.

47 OTHER INSTRUMENTATION↗