Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GODIVA REACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

79 records · Page 5

Godiva IV Shielding Benchmark Overview [Slides]

This presentation shows that Integral experiments increase the level of realism from that of data measurements. Further, Godiva IV is capable of intensities to activate foils. IER 498 uses a relative measurement to provide an intermediate level of realism. With reproducibility and room return management are key components. The test matrix put forward in CED-2 enables numerous cross-comparisons. IER 498 facilitates various additional works using a room return shield to isolate the source. IER 557 demonstrated burst reproducibility sufficient for IER 498.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity of posterior parameter correlations and response parameter correlations to prior response uncertainty

The two parameters one response model of the generalized linear least squares parameter adjustment methodology was used in order to analyze the procedure of improving cross sections agreement with integral experimental results. Two extreme adjustment cases were considered. One case is using extremely accurate measured integral responses, such as k{sub eff} of Godiva or Jezebel for instance. The other one is modifying only one parameter, for instance the modification of {nu}-bar in ENDF/B-VII, in order to improve agreement of calculated responses with corresponding integral measurements results. In both cases new posterior parameters correlations are generated. The conclusion is that it is not advised to use integral measurements information in the evaluation process of a general purpose nuclear data file. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A new dose assessment method for the UK system of criticality accident dosimetry - 14420

A new method for the measurement and interpretation of the Harwell criticality accident dosemeter has been developed. The new method treats the dosemeter components as individual detector elements with unique energy-dependent response functions generated with MCNP6. A bespoke deconvolution code was written that generates a parameterized neutron spectrum from the integral activities in each detector element. The spectrum can be folded with any set of fluence-to-dose conversion coefficients to determine an integral dose. The new method has been validated computationally using realistic neutron spectra and experimentally in a series of test irradiations using the Godiva-IV, CALIBAN and PROSPERO critical assemblies. The method was able to reproduce the true dose with a small positive bias and a combined relative uncertainty of 25 % across the full range of spectra considered (10 pGy cm{sup 2} to 45 pGy cm{sup 2}). (authors)

42 ENGINEERING↗

LLNL Final Design for PDV Measurements of Godiva for Validation of Multi-Physics Simulation

This document is a Final Design (CED-2) Report for IER-268, “PDV Measurements of Godiva for Validation of Multi-Physics Simulation”. These measurements will measure surface velocities in several locations, the initial α and α-t curve as a function of fission yield using existing LLNL assets including: The portable Photonic Doppler Velocimeter (PDV) detector; The “alpha box”, and; Aluminum-encapsulated 235 U fission foils. These experiments will be simulated using multi-physics methods funded separately under LLNL-AM2. A supercritical benchmark specification will be developed; and, if funding permits, an ICSBEP (or classified equivalent) evaluation will be published.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

National Criticality Experiments Research Center: Capability and Status

After seven years, the former Los Alamos Critical Experiments Facility (LACEF), or Pajarito Site, has reopened for business as the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS). Four critical assembly machines (Comet, Planet, Flat-Top, and Godiva-IV) made the journey from Los Alamos to the NNSS. All four machines received safety system upgrades along with new digital control systems. Between these machines, systems ranging from the thermal through the intermediate to the fast spectrum may be assembled. Steady-State, transient, and super-prompt critical conditions may be explored. NCERC is the sole remaining facility in the United States capable of conducting general-purpose nuclear materials handling including the construction and operation of high-multiplication assemblies, delayed critical assemblies, and prompt critical assemblies. Reconstitution of the unique capabilities at NCERC ensures the viability of (1) The Nuclear Renaissance, (2) Stockpile Stewardship, and (3) and the next generation of criticality experimentalists.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Awe Bonner sphere measurements of the neutron leakage spectrum from the GODIVIA-IV critical assembly at NCERC - 14413

The US National Criticality Experiments Research Centre (NCERC) is home to several critical assembly machines that were relocated from Los Alamos National Laboratory in the last decade. The centre is sponsored by the Department of Energy's Nuclear Criticality Safety Program (NCSP), which has the mission to ensure the safe handling of fissile materials from a criticality perspective. Under the auspices of the NCSP, Lawrence Livermore National Laboratory (LLNL) is planning to host an international inter-comparison of nuclear accident dosimetry (NAD) using the Godiva-IV assembly at NCERC. The inter-comparison is motivated by a decline in the frequency of performance testing of NADs (both in the US, the UK and France) and the desire to modernize and harmonize dosimetry systems. A pre-requisite for the inter-comparison is the characterisation of the neutron and gamma-ray leakage spectra associated with the Godiva-IV assembly at NCERC. AWE provided its Bonner-sphere spectrometry capability to LLNL for two experimental campaigns, in November 2013 and May 2014, to measure the neutron leakage spectrum of the assembly in both a sub-critical 'steady-state' and a super-prompt-critical 'burst'. Nine points, at distances from 2 to 4 meters from the machine were measured with the Bonner-sphere spectrometer using both an active He-3 detector and a passive technique employing gold foils. This paper presents the spectra unfolded from the data and integral dose values, and compares these to previously published data. The limitations of the work and future plans are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Joint neutron measurements on the flat-top HEU critical assembly machine - 14388

Flat-Top is a critical assembly with a spherical core (either ∼17 kg of HEU or ∼6 kg of δ-phase Pu) surrounded by a spherical 1000 kg natural uranium reflector. In 2013, joint LANL and CEA measurements were conducted to measure Flat-Top configurations with the HEU core using He-3 detector systems. Similar experiments were previously documented in which the Caliban and Godiva critical assemblies were measured. The core and reflector of Flat-Top have a glory hole in which nuclear material or non-nuclear material may be placed. Five configurations were measured and included subcritical configurations at various reactivity states as well as a configuration at delayed critical. The various reactivity states were achieved by varying the placement of the safety blocks and control rods (composed of natural uranium). A description of the assembly and the specific configurations measured will be presented. The subcritical and delayed critical measurements were analyzed using the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This analysis can be used to calculate the multiplication of each configuration, from which the multiplication factor and reactivity are determined. These results are compared to the reactivity states based upon control rod worth curves and MCNP simulations. For this work, a new MCNP model was made to accurately represent the measured configurations. The ICSBEP handbook contains a benchmark of Flat-Top but all models are very simple and do not have the required fidelity to accurately represent the measured configurations. This work also examines the number of neutrons emitted per fission for this assembly (which has a significant contribution of induced fissions in U-238 due to the large natural uranium reflector). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗