Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLOVEBOXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Centrifuge Facility Life Sciences Glovebox configuration study

Crew operations associated with nonhuman life sciences research on Space Station Freedom will be conducted in the Life Sciences Glovebox, whose enclosed work volume must accommodate numerous life science procedures. Two candidate Glovebox work volume concepts have been developed: one in which two operators work side-by-side, and another that conforms to the reach envelope of a single operator. Six test volunteers tested the concepts according to preestablished operational criteria. The wrap-around, single-operator concept has been judged the superior system.

Sun, Sidney C.↗

The USML-1 wire insulation flammability glovebox experiment

Flame spreading tests have been conducted using thin fuels in microgravity where buoyant convection is suppressed. In spacecraft experiments flames were ignited in quiescent atmospheres with an elevated oxygen content, demonstrating that diffusional mechanisms can be sufficient alone to sustain flame spreading. In ground-based facilities (i.e. drop towers and parabolic aircraft) low-speed convection sustains flames at much lower concentrations of atmospheric oxygen than in quiescent microgravity. Ground-based experiments are limited to very thin fuels (e.g., tissue paper); practical fuels, which are thicker, require more test time than is available. The Glovebox Facility provided for the USML 1 mission provided an opportunity to obtain flame spreading data for thicker fuel Herein we report the results from the Wire Insulation Flammability (WIF) Experiment performed in the Glovebox Facility. This experiment explored the heating, ignition and burning of 0.65 mm thick polyethylene wire insulation in low-speed flows in a reduced gravity environment. Four tests were conducted, two each in concurrent flow (WIF A and C) and opposed flow (WIF B and D), providing the first demonstration of flame spreading in controlled forced convection conducted in space.

Greenberg, Paul S.↗

Mir Glovebox Facility

The Glovebox Facility on Mir was developed by the Marshall Space Flight Center for use on the space shuttle middeck and modified slightly for use on the Mir Space Station. Its design is based on a similar facility provided by the European Space Agency for use on Spacelab and flown on the USML-I and 2 missions. Its purpose is to provide a work space for experiments which is isolated from the manned environment while allowing a high degree of access to the experiment apparatus. It also provides experiment power, lighting, and data acquisition. This facility has successfully supported 7 experiments representing the fluid physics and combustion disciplines during NASA increments 2 - 5. During over 400 hours of operation, only 3 minor facility anomalies were encountered, none of which prevented science operations or resulted in hazardous conditions. No in-flight maintenance has been required through increment 5. Crew comments have been generally favorable, stressing the usefulness, reliability and ease of use of the facility. The success of the glovebox to date demonstrates the value of this type of multi-use facility in a space station environment.

Kroes, Roger L.↗

NASA Virtual Glovebox: An Immersive Virtual Desktop Environment for Training Astronauts in Life Science Experiments

The International Space Station will soon provide an unparalleled research facility for studying the near- and longer-term effects of microgravity on living systems. Using the Space Station Glovebox Facility - a compact, fully contained reach-in environment - astronauts will conduct technically challenging life sciences experiments. Virtual environment technologies are being developed at NASA Ames Research Center to help realize the scientific potential of this unique resource by facilitating the experimental hardware and protocol designs and by assisting the astronauts in training. The Virtual GloveboX (VGX) integrates high-fidelity graphics, force-feedback devices and real- time computer simulation engines to achieve an immersive training environment. Here, we describe the prototype VGX system, the distributed processing architecture used in the simulation environment, and modifications to the visualization pipeline required to accommodate the display configuration.

Twombly, I. Alexander↗

Robotic Sample Manipulator for Handling Astromaterials Inside the Geolab Microgravity Glovebox

Future human and robotic sample return missions will require isolation containment systems with strict protocols and procedures for reducing inorganic and organic contamination. Robotic handling and manipulation of astromaterials may be required for preliminary examination inside such an isolation containment system. In addition, examination of astromaterials in microgravity will require constant contact to secure samples during manipulation. The National Space Grant Foundation exploration habitat (XHab) academic innovative challenge 2012 administered through the NASA advanced exploration systems (AES) deep space habitat (DSH) project awarded funding to the University of Bridgeport team to develop an engineering design for tools to facilitate holding and handling geological samples for analysis in a microgravity glovebox environment. The Bridgeport XHab team developed a robotic arm system with a three-finger gripper that could manipulate geologic samples within the existing GeoLab glovebox integrated into NASA's DSH called the GeoLab Robotic Sample Manipulator (see fig. 1 and 2). This hardware was deployed and tested during the 2012 DSH mission operations tests [1].

Bell, Mary S.↗

Microgravity Science Glovebox (MSG) Space Science's Past, Present, and Future on the International Space Station (ISS)

The Microgravity Science Glovebox (MSG) is a double rack facility designed for microgravity investigation handling aboard the International Space Station (ISS). The unique design of the facility allows it to accommodate science and technology investigations in a "workbench" type environment. MSG facility provides an enclosed working area for investigation manipulation and observation in the ISS. Provides two levels of containment via physical barrier, negative pressure, and air filtration. The MSG team and facilities provide quick access to space for exploratory and National Lab type investigations to gain an understanding of the role of gravity in the physics associated research areas. The MSG is a very versatile and capable research facility on the ISS. The Microgravity Science Glovebox (MSG) on the International Space Station (ISS) has been used for a large body or research in material science, heat transfer, crystal growth, life sciences, smoke detection, combustion, plant growth, human health, and technology demonstration. MSG is an ideal platform for gravity-dependent phenomena related research. Moreover, the MSG provides engineers and scientists a platform for research in an environment similar to the one that spacecraft and crew members will actually experience during space travel and exploration. The MSG facility is ideally suited to provide quick, relatively inexpensive access to space for National Lab type investigations.

Spivey, Reggie A.↗

Organic Contamination Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

Future planned sample return missions to carbon-rich asteroids and Mars in the next two decades will require strict handling and curation protocols as well as new procedures for reducing organic contamination. After the Apollo program, astromaterial collections have mainly been concerned with inorganic contamination [1-4]. However, future isolation containment systems for astromaterials, possibly nitrogen enriched gloveboxes, must be able to reduce organic and inorganic cross-contamination. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs that could be used as a benchmark for future mission designs.

Calaway, Michael J.↗

Lunar Processing Cabinet 2.0: Retrofitting Gloveboxes into the 21st Century

In 2014, the Apollo 16 Lunar Processing Glovebox (cabinet 38) in the Lunar Curation Laboratory at NASA JSC received an upgrade including new technology interfaces. A Jacobs - Technology Innovation Project provided the primary resources to retrofit this glovebox into the 21st century. NASA Astromaterials Acquisition & Curation Office continues the over 40 year heritage of preserving lunar materials for future scientific studies in state-of-the-art facilities. This enhancement has not only modernized the contamination controls, but provides new innovative tools for processing and characterizing lunar samples as well as supports real-time exchange of sample images and information with the scientific community throughout the world.

Calaway, M. J.↗

Overview of the Life Sciences Glovebox (LSG) Facility

The Life Sciences Glovebox (LSG) is a rack-level payload facility designed to house biological investigations in a "workbench" type environment aboard the International Space Station (ISS). The facility is scheduled to be launched in September 2018 and will be installed in the Japanese Experiment Module (JEM) of the ISS. LSG is comprised of an extendable work volume, an airlock, an avionics package, a laptop, and supporting structure. The 450L work volume provides two levels of containment for investigations via the physical barrier of its structure and an internal, filtered airflow that results in a negative pressure relative to ISS cabin pressure. The facility provides many other resources for investigation use including 28 VDC power, 120 VAC power, heat rejection, data connections, and video. Portions of the interior surfaces of the work volume are ferrous, allowing investigations and supporting hardware to be magnetically affixed to these surfaces. A UV decontamination system and a variety of ancillary hardware are available for investigations to use while occupying LSG. An engineering unit on the ground is used for payload development and integrated verification testing. Once the facility is installed and commissioned, it will be managed by the same team that manages the Microgravity Science Glovebox (MSG), another rack-level payload facility that has been operating aboard the ISS since 2002. Experienced Investigation Payload Integration Managers (IPIMs), who also support MSG payloads, will be available to assist payload developers through the integration process. This presentation will provide an overview of the LSG facility and the planned investigation flow for the near future.

Jordan, Lee↗

Life Sciences Glovebox (LSG)

The Life Sciences Glovebox (LSG) accommodates life science and technology investigations in a “workbench” type environment. It is used for biological studies, including rodent research and cell biology. The facility has an enclosed Work Volume (WV) that is held at a negative pressure with respect to the crew living area. This allows the facility to provide two levels of containment for handling Biohazard Level II and lower biological materials. The LSG facility is operated by the Payloads Operations Integration Center at MSFC. Payloads may also operate remotely from different telescience centers located in the United States and different countries. The Glovebox Integration Engineer (GIE) is the focal to assist organizations that have payloads operating in the LSG facility. NASA provides an LSG engineering unit for payload developers, fit checks, and to verify that the hardware is operating properly before beginning actual operations on the ISS.

biology↗

CHARACTERIZATION OF GLOVEBOX GLOVES FOR THE SAVANNAH RIVER SITE

A task was undertaken to characterize glovebox gloves that are currently used in the facilities at Savannah River Site (SRS) as well as some experimental and advanced compound gloves that have been proposed for use. Gloves from four manufacturers were tested for permeation in hydrogen and air, thermal stability, tensile properties, puncture resistance and dynamic mechanical response. The gloves were compared to each other within the type and also to the butyl rubber glove that is widely used at the SRS. The permeation testing demonstrated that the butyl compounds from three of the vendors behaved similarly and exhibited hydrogen permeabilities of .52‐.84 x10{sup ‐7} cc H{sub 2}*cm / (cm{sup 2}*atm). The Viton glove performed at the lower edge of this bound, while the more advanced composite gloves exhibited permeabilities greater than a factor of two compared to butyl. Thermogravimetric analysis was used to determine the amount of material lost under slightly aggressive conditions. Glove losses are important since they can affect the life of glovebox stripper systems. During testing at 90, 120, and 150°C, the samples lost most of the mass in the initial 60 minutes of thermal exposure and as expected increasing the temperature increased the mass loss and shortened the time to achieve a steady state loss. The ranking from worst to best was Jung butyl‐Hypalon with 12.9 %, Piercan Hypalon with 11.4 %, and Jung butyl‐Viton with 5.2% mass loss all at approximately 140°C. The smallest mass losses were experienced by the Jung Viton and the Piercan polyurethane. Tensile properties were measured using a standard dog bone style test. The butyl rubber exhibited tensile strengths of 11‐15 MPa and elongations or 660‐843%. Gloves made from other compounds exhibited lower tensile strengths (5 MPa Viton) to much higher tensile strengths (49 MPa Urethane) with a comparable range of elongation. The puncture resistance of the gloves was measured in agreement with an ASTM standard. The Butyl gloves exhibited puncture resistance from 183 - 296 lbs/in for samples of 0.020 - 0.038 thick. Finally, the glass transition temperature and the elastic and viscoelastic properties as a function of temperature up to maximum use temperature were determined for each glove material using Dynamic Mechanical Analysis. The glass transition temperatures of the gloves were ‐60°C for butyl, ‐30°C for polyurethane, ‐ 16°C Hypalon, ‐16°C for Viton, and ‐24°C for polyurethane‐Hypalon. The glass transition was too complex for the butyl‐Hypalon and butyl‐Viton composite gloves to be characterized by a single glass transition temperature. All of the glass transition temperatures exceed the vendor projected use temperatures.

42 ENGINEERING↗

Neutron Radiation Shielding Strategies for Glovebox Applications

Practical methods for implementing neutron radiation shielding into glovebox applications is discussed. Basic neutron emission shielding strategy and mathematical modeling is introduced. Typical materials used for shielding are introduced along with cost benefit considerations of each. Two examples of neutron radiation shielding implemented into glovebox applications is presented and discussed.

42 ENGINEERING↗

Ergonomic glovebox workspace layout tool and associated method of use

The present invention provides an elongate tool that aides in the placement of objects and machinery within a glovebox, such that the objects and machinery can be safely handled by a user. The tool includes a plurality of visual markings (in English units, metric units, other units, grooves, ridges, varying widths, etc.) that indicate distance from the user within the glovebox, optionally broken into placement preference zones that are color coded, grayscale coded, or the like.

47 OTHER INSTRUMENTATION↗

Transfer ports for confinement gloveboxes and related methods

Transfer ports for confinement gloveboxes may include a flange sized and shaped to be secured within an opening in a wall of a glovebox. A sleeve may be secured to the flange and define a passage through the flange. A first cap may be removably secured to the sleeve on a first side of the flange and obstruct the passage on the first side. A second cap may be removably secured to the sleeve on a second, opposite side of the flange and obstruct the passage on the second side.

Balsmeier, Aaron A.↗

Engineering Controls for the Processing and Repackaging of Gloveboxes Contaminated with Plutonium - 19629

Gloveboxes used for processing plutonium (Pu)-238 at the US DOE Mound site in Miamisburg, Ohio, in support of the United States space mission were packaged in non-standard waste boxes and sent to the INL Site for temporary disposal. In addition to the gloveboxes, an assortment of smaller items, all with varying levels of Pu-238 contamination, were found in the non-standard waste boxes. The characteristics of Pu-238 make it especially difficult to contain and control contamination; alpha recoil phenomena and nanometer particle sizes lend to the contamination exhibiting near gas like characteristics. The Idaho Cleanup Project Core contractor, Fluor Idaho, LLC, engineered and deployed a waste processing containment with specialized ventilation and processes to characterize and disposition this waste. This paper summarizes the successes and lessons learned from processing Pu-238-contaminated waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A case history in glovebox glove selection

Here, glovebox glove selection for a unique experiment is discussed, including gloves that deteriorated so that they required replacement over the course of experimentation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An open-walled ionization chamber appropriate to tritium monitoring for glovebox

An open-walled ionization chamber is developed to monitor the tritium concentration in gloveboxes in tritium processing systems. Two open walls are used to replace the sealed wall in common ionization chambers, through which the tritium gas can diffuse into the chamber without the aid of pumps and pipelines. Some basic properties of the chamber are examined to evaluate its performance. Results turn out that an open-walled chamber of 1 l in volume shows a considerably flat plateau over 700 V for a range of tritium concentration. The chamber also gives a good linear response to gamma fields over 4 decades under a pressure condition of 1 atm. The pressure dependence characteristics show that the ionization current is only sensitive at low pressures. The pressure influence becomes weaker as the pressure increases mainly due to the decrease in the mean free path of {beta} particles produced by tritium decay. The minimum detection limit of the chamber is 3.7x10{sup 5} Bq/m{sup 3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Glovebox Gloves for Effective Permeation Control

A research and development task was undertaken to determine the permeabilities of hydrogen and dry air through different polymeric glove materials that are used to maintain the integrity of glovebox secondary containment. Fifteen different glove samples were obtained from four different manufacturers and samples cut from these gloves were tested. The gloves included baseline butyl rubber, Viton * , Dupont * Hypalon * , polyurethane, as well as composite gloves. The testing indicated that all of the vendor's butyl rubber gloves and the Jung Viton * gloves performed comparably in both gases.

08 HYDROGEN↗