NOBLE METAL MASS TRANSPORT MODEL FOR MOLTEN SALT REACTOR ANALYSIS IN VERA-CS

Molten Salt Reactor designs require robust multiphysics modelling capabilities to further the development of this next generation technology. Due to the unique liquid fuel design, traditional reactor physics analysis codes do not capture all of the important physics of these reactors. This work builds upon a general species transport model implemented into the multiphysics core simulator suite VERA-CS, by adding source and sink models for non-soluble fission products, specifically the noble metals. Noble metal fission products are born in the fuel-salt, but do not form stable fluorides, and instead plate out on various surfaces in the reactor fuel loop. A concentration gradient diffusion-convection based mass transfer model is implemented into the general species transport model within CTF-the subchannel thermal hydraulics code in VERA-CS-and verified. Two noble metal decay chains are analyzed, and their steady state bulk and surface concentrations are calculated for a simple flow loop in CTF that is representative of the Oak Ridge National Laboratory Molten Salt Reactor Experiment (MSRE). Non-soluble species 99Mo to 99Tc captures wall plate out of decaying species, and non-soluble 135Te to soluble 135I and gaseous 135Xe captures wall loss of decaying species. Results are compared with MSRE data and the possible multiphysics effects of this phenomena are identified. Future work to enhance the robustness of the physical model and couple it with neutronics to evaluate these effects of Noble Metal mass transport is discussed.

Walker, Samuel↗

Membrane loop process for separating carbon dioxide for use in gaseous form from flue gas

The invention is a process involving membrane-based gas separation for separating and recovering carbon dioxide emissions from combustion processes in partially concentrated form, and then transporting the carbon dioxide and using or storing it in a confined manner without concentrating it to high purity. The process of the invention involves building up the concentration of carbon dioxide in a gas flow loop between the combustion step and a membrane separation step. A portion of the carbon dioxide-enriched gas can then be withdrawn from this loop and transported, without the need to liquefy the gas or otherwise create a high-purity stream, to a destination where it is used or confined, preferably in an environmentally benign manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Membrane loop process for separating carbon dioxide for use in gaseous form from flue gas

The invention is a process involving membrane-based gas separation for separating and recovering carbon dioxide emissions from combustion processes in partially concentrated form, and then transporting the carbon dioxide and using or storing it in a confined manner without concentrating it to high purity. The process of the invention involves building up the concentration of carbon dioxide in a gas flow loop between the combustion step and a membrane separation step. A portion of the carbon dioxide-enriched gas can then be withdrawn from this loop and transported, without the need to liquefy the gas or otherwise create a high-purity stream, to a destination where it is used or confined, preferably in an environmentally benign manner.

42 ENGINEERING↗

Demonstration and Feasibility Analyses of using the Dual-Purpose Canister Drain Pipe to Support the Filling Process

This report documents experiments that are being used to determine the feasibility of filling dual-purpose canisters (DPCs) using the existing drain pipe. Mercury was identified as a surrogate filler for the initial experiments. Oak Ridge National Laboratory’s Target Test Facility (TTF), which is a full-scale Spallation Neutron Source (SNS) prototypical mercury loop, is being used for the planned pipe experiments using mercury. The pipe experiments were divided into two phases to provide a separate effects approach to the problem and to allow for development of system scalability. The first phase included taking strain measurements in a short length pipe, as well as measurements of flow-induced vibration. The second phase consists of the design and construction of a separated mercury flow loop capable of hosting exchangeable test sections and more localized instrumentation. Data acquisition of Phase I was performed during this reporting time period, and subsequent data reduction and data analysis will be performed in the future.

36 MATERIALS SCIENCE↗

Demonstration and Feasibility Analyses of Using the Dual-Purpose Canister Drain Pipe to Support the Filling Process

This work documents experiments that are being used to determine the feasibility of filling dual-purpose canisters (DPCs) using the existing drain pipe. Mercury was identified as a surrogate filler for the initial experiments. Oak Ridge National Laboratory’s Target Test Facility (TTF), which is a full-scale Spallation Neutron Source (SNS) prototypical mercury loop, is being used for the planned pipe experiments using mercury. The pipe experiments were divided into two phases to provide a separate effects approach to the problem and to allow for development of system scalability. The first phase included taking strain measurements in a short length pipe, as well as measurements of flow-induced vibration. The second phase consists of the design and construction of a separated mercury flow loop capable of hosting exchangeable test sections and more localized instrumentation. Data acquisition of Phase I was performed during this work and is presented in the form of strain measurements and vibration frequency.

Dominguez-Ontiveros, Elvis↗

Note: A dual temperature closed loop batch reactor for determining the partitioning of trace gases within CO{sub 2}-water systems

An experimental approach is presented which can be used to determine partitioning of trace gases within CO{sub 2}-water systems. The key advantages of this system are (1) The system can be isolated with no external exchange, making it ideal for experiments with conservative tracers. (2) Both phases can be sampled concurrently to give an accurate composition at each phase at any given time. (3) Use of a lower temperature flow loop outside of the reactor removes contamination and facilitates sampling. (4) Rapid equilibration at given pressure/temperature conditions is significantly aided by stirring and circulating the water phase using a magnetic stirrer and high-pressure liquid chromatography pump, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heat Exchanger Intensification Through Powder Processing and Enhanced Design (HIPPED)

High intensity, supercritical CO 2 heat exchangers capable of operating at temperatures between 800 and 1100 ˚C and pressures greater than 80 bar are considered a critical component for high efficiency power generation and a range of next-generation industrial processes. A novel heat exchanger concept was proposed in this project. The proposed concept involved a plate-type architecture with three-dimensional fins, called twisted s-shaped fins, that capitalize on additive manufacturing. Four manufacturing processes were studied to realize the complex envisioned design: press and sinter of metallic powders, directed energy deposition, laser powder bed fusion, and a novel powder bed process involving a photoreactive polymer called SEAM (scalable expeditious additive manufacturing), that later was developed at MSU. The team was able to manufacture subscale heat exchangers using laser powder bed fusion (LPBF) and SEAM. The team settled on using SEAM as a final manufacturing approach due to its very low cost. The SEAM-manufactured heat exchanger, however, when tested under pressure, exhibited leaks and the process still requires further development beyond the timeline of the project. To support the heat exchanger design and testing, the team developed a new high temperature flow loop allowing testing under high temperature and pressure. Computational modeling of the heat exchanger was also performed for the twisted s-shaped fins and the computations were validated with experimental data. The new twisted fins resulted in enhanced heat transfer and reduced pressure drop. To further minimize pressure drop in the plate heat exchanger, the team also developed a simplified model for flow maldistribution in the manifolds, providing a new tool for designers that eliminates the need for complex CFD calculations. A technoeconomic analysis was also developed to contrast SEAM with LPBF, this tool indicated that SEAM is several times less costly and offer significant promises as a rapid low cost additive manufacturing process for metallic systems.

30 DIRECT ENERGY CONVERSION↗

Recovery of dilute aqueous butanol by membrane vapor extraction with dodecane or mesitylene

A novel, nearly isothermal, nonselective-membrane separation process, membrane vapor extraction (MVE), efficiently recovers butanol from a dilute aqueous solution, for example, from a fermentation broth (Liu et al., 2015). In MVE, feed and solvent liquids are not in contact; they are separated by vapor. Therefore, compared to conventional extraction, MVE avoids formation of difficult-to-separate emulsions. In MVE, a semi-volatile aqueous solute (e.g., butanol) vaporizes at the upstream side of a membrane, diffuses as a vapor through the membrane pores, and subsequently condenses and dissolves into a high-boiling nonpolar solvent, favorable to the solute but not to water. Design analysis of a 1.5-m long, 30-m 2 membrane-area countercurrent MVE unit for processing 2-wt% aqueous butanol by dodecane solvent at 40 °C indicates over 90% recovery of the feed butanol with essentially no water loss and with very low energy requirement (Liu et al., 2015). The separation factor is over 1500. However, the published design study gives no experimental evidence for the calculated MVE separation. Here, we present experimental data to validate the MVE process. We use an omniphobic (i.e., hydrophobic and oleophobic), 0.2-µm pore-diameter Versapor®200 R membrane (Pall Corporation, Exton, PA) housed in a 6-cm wide by 10-cm long plate-and-frame channeled flow cell with 0.8-cm gap thickness. Membrane transfer area is 28 cm 2 . The membrane flow cell is designed for minimal axial concentration change and is operated in the transient mode between two recirculating flow loops. 2-wt% aqueous butanol is extracted into dodecane or mesitylene at 25 or 40 °C. Also, 1.5-wt% furfural is extracted into dodecane at 40 °C. Since vapor transport across the membrane contributes minimal resistance, MVE performance is governed by mass transfer through feed and solvent boundary layers. Mass-transfer coefficients are determined from the Graetz-Lévêque analysis of laminar thin-slit flow (Bird et al., 2002). Predicted extraction performance agrees well with experiment using no adjustable parameters. Finally, consistent with the initial multistage-design analysis (Liu et al., 2015), our new bench-scale experimental results confirm that MVE is a viable separation process to recover dilute semi-volatile biosolutes from water with minimal energy requirement. Preliminary analysis of downstream solute recovery from the extract via distillation is more efficient than that for pervaporation because of insignificant water carry over through the MVE membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MAGNETICALLY SUSPENDED CANNED ROTOR PUMPS FOR THE INTEGRAL MOLTEN SALT REACTOR

This project developed a molten salt pump design for small modular reactors, concentrated solar, and Gen IV nuclear reactors with a magnetically levitated rotor that can operate at temperatures of up to 700 °C. This eliminates the need for rotating seals and roller element bearings which require maintenance and are prone to failure. The pump design is also more compact than existing molten salt pump designs which require long shafts to thermally isolate the electric motor. The aims of the project are to: 1) design and test the molten salt pump, 2) develop and test a high temperature position sensor needed for magnetic bearing control, and 3) develop and test high temperature coil fabrication methods for electric motor and magnetic bearing fabrication. To develop the high temperature coils, conductor materials were analyzed for oxidation, diffusion, cladding, and resistivity. Of the candidate conductor materials that met the requirements, silver was chosen. The long-term impact of radiation on silver resistivity was analyzed by developing a model of a generic molten salt fast reactor to model the conductor irradiation in worst case scenarios. The analysis showed that increased resistivity due to transmutation of silver decreases exponentially with the reactor reflector thickness. Different electrical insulation materials were tested and the final high temperature coils developed were able to withstand conductor to ground voltages up to 1800 V before insulation breakdown. Magnetic bearings require high-precision high-speed measurements of the rotor position to operate. Current commercial position sensors can only operate up to 550 °C so a novel position sensor was developed that can operate up to 800 °C. These sensors were also designed to measure the position of the metallic rotor through a thin metallic corrosion barrier that protects that coils, insulation, and magnetic cores so that the salt containment barrier does not have any penetrations. The high-temperature sensor was tested and had comparable performance to commercially available inductive position sensors. The sensor design and signal processing has led to several invention disclosures. The magnetically levitated molten salt pump design was completed and analyzed. The chloride salt test loop at Oak Ridge National Laboratory was chosen to test the pump and the pump hydraulics and power were designed for the test loop flow and pressure requirements. Classes of motor designs that do not utilize permanent magnetic were considered for the high-temperature motor. After extensive analysis of their performance, a synchronous reluctance motor was chosen for the pump. The design was refined and analyzed to optimize performance. The magnetic bearings were designed to meet the force and frequency requirements necessary to levitate the rotor and reject disturbances from rotor imbalance, motor forces, and hydraulic forces. Compliant mounts for the position sensors were designed that would not damage the ceramic sensor components and maintain sensor alignment over a wide temperature range. A thermal hydraulic analysis of the molten salt coolant flow used to cool the rotor and stator was performed to ensure that the maximum temperature in the rotor and stator will not exceed 725 °C. The corrosion barrier and casing were designed to maintain the salt fluid boundary by using compliant features to absorb large expansion mismatches due to different coefficients of thermal expansion (CTE). Finally, the salt drain and fill systems were designed along with the pump support structure, integration with the test loop, and thermal insulation and heating. Corrosion barrier fabrication experiments were performed to assess using laser cladding to apply a sub-millimeter corrosion barrier to the surface of a Fe-Co-V magnetic core material. The cladding method showed minimal mixing between materials at their interface and withstood temperature cycling without damage to the cladding. The technology commercialization is focused on the high-temperature position sensors and there has been significant interest from the nuclear industry in utilizing these sensors along with some interest from the aerospace industry. The project also led to a research collaboration with a fusion energy industrial partner to study barriers to scaling the pump design from the kW size to the MW size. This research collaboration will also study methods to create high-temperature coils that have conductor to ground breakdown voltages above 5 kV. The successful development of high-temperature electromagnetic coils and high-temperature position sensors greatly increases the temperature limits for electromagnetic devices that don’t rely on permanent magnets. This includes electric motors, magnetic bearings, linear actuators, rotary position and velocity sensing, actuated valves, and generators to name a few. This will fill a current need in molten salt reactors, concentrated solar, and fusion energy for these critical peripheral devices needed for practical reactor designs that do not currently have commercial solutions.

Hines, J Wesley↗

An integrated coupling model for solving multiscale fluid-fluid coupling problems in SAM code

In this study, an integrated coupling method has been developed for solving multiscale fluid-fluid coupling problems in plant-scale safety analysis models in SAM (System Analysis Module) code. In this method, a higher-fidelity multi-dimensional (3D) flow module is used for reactor components of complex flow features (e.g., reactor core) and a lumped parameter one-dimensional (1D) flow module for plant-scale flow loops (e.g., primary loop pipe network), respectively. In this method, the 3D fluid equation/domain and 1D fluid equation/domain are tightly coupled at the residual level and solved simultaneously using the Newton’s method to overcome the convergence issues typically seen in existing approaches like separate domain approach, where the 3D fluid equation and 1D fluid equation are solved separately. Extensive and successful code verifications and demonstrations have been performed for this newly developed method. This new modeling approach significantly simplify the work flow in developing high-fidelity plant-scale safety analysis model, e.g. for pool-type reactors and pebble-bed reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Porous media properties of reticulated shape memory polymer foams and mock embolic coils for aneurysm treatment

Background: Shape memory polymer (SMP) foams are being investigated as an alternative aneurysm treatment method to embolic coils. The goal of both techniques is the reduction of blood flow into the aneurysm and the subsequent formation of a stable thrombus, which prevents future aneurysm rupture. The purpose of this study is to experimentally determine the parameters, permeability and form factor, which are related to the flow resistance imposed by both media when subjected to a pressure gradient. Methods: The porous media properties—permeability and form factor—of SMP foams and mock embolic coils (MECs) were measured with a pressure gradient method by means of an in vitro closed flow loop. We implemented the Forchheimer-Hazen-Dupuit-Darcy equation to calculate these properties. Mechanically-reticulated SMP foams were fabricated with average cell sizes of 0.7E-3 and 1.1E-3 m, while the MECs were arranged with volumetric packing densities of 11-28%. Results: The permeability of the SMP foams was an order of magnitude lower than that of the MECs. The form factor differed by up to two orders of magnitude and was higher for the SMP foams in all cases. The maximum flow rate of all samples tested was within the inertial laminar flow regime, with Reynolds numbers ranging between 1 and 35. Conclusions: The SMP foams impose a greater resistance to fluid flow compared to MECs, which is a result of increased viscous and inertial losses. These results suggest that aneurysms treated with SMP foam will have flow conditions more favorable for blood stasis than those treated with embolic coils having packing densities ≤ 28%.

36 MATERIALS SCIENCE↗

Experimental study on rheological and settling properties of shape memory polymer for fracture sealing in geothermal formations

This article studies the rheology and annular flow of a smart lost circulation material (LCM) at 160 °C, using a high-temperature flow loop. The smart LCM is a shape memory polymer (SMP) that activates at high temperatures, and its particle size increases to seal fractures in geothermal formations. SMP was mixed with the base fluid in two different concentrations, 1.0 and 3.0 wt%, to study rheology, wellbore hydraulics, activation process, and settling behavior under different testing conditions. The results of this study showed that the SMP could be activated at high temperatures. An increase of 80–100% in the particle size was observed at 160 °C. The mud samples showed a high shear-thinning behavior at the two concentrations with a Power-law flow index (n) ranging between 0.025 and 0.101. No additional frictional pressure losses were observed when SMP was added to the base fluid. SMP particles showed an excellent suspension at 1.0 wt% while, at 3.0 wt%, a bed was formed at a low flow rate and without pipe rotation. Increasing the drill pipe rotational speed or flow rate effectively removed the bed and homogeneously dispersed the SMP particles, ensuring a better sealing efficiency. SMP particle dispersion in inclined wells was better than in horizontal wells. Moreover, the findings of this study help optimize the lost circulation treatment by considering a wide range of operating parameters that can further be extended to different systems and geometries.

02 PETROLEUM↗

Evaluation of Lost Circulation Material Sealing for Geothermal Drilling

Lost circulation is a pervasive problem in geothermal wells that can create prohibitive costs during drilling. The main issue with treatment is that the mechanism of plug formation is poorly understood. Here we applied two experimental approaches to characterize the clogging effectiveness of different materials. Fracture flow tests with different geometries were conducted with various individual materials and mixtures at relevant conditions. A high-temperature flow loop system was also developed to inject single- and mixed-material plugs into a gravel pack with a non-uniform geometry to compare with the fracture tests. The fracture tests revealed that single materials tended to form no plug or an unstable plug, while mixtures of materials were uniformly better at sealing fractures. Gravel pack tests at high temperatures show most of the materials are intact but degraded. The fibrous materials can create partial or unstable plugs in the gravel pack, but mixed-material plugs are far more effective at clogging. Both test types suggest that (1) mixed materials are more effective at blocking fluid flow and (2) fibrous materials seal fracture openings better, while granular materials seal inside fractures or pore throats better. Further research is needed to study the long-term stability of different plug configurations.

clogging tests↗

Evaluation of a Versatile Experimental Salt Irradiation Loop (VESIL) inside the Advanced Test Reactor

A Versatile Experimental Salt Irradiation Loop (VESIL) is under investigation at Idaho National Laboratory. An initial feasibility study was conducted for potential deployment inside the Advanced Test Reactor (ATR). Historical salt-irradiation tests are reviewed and summarized in this report. The study also surveys available instrumentation for this type of application and identifies key design and testing requirements. Neutronic analysis was performed in different ATR position for various salt candidates using MCNP6 and ORIGEN-6.2. The results indicate that both the B and I-positions are suitable for VESIL. The B-position allows for accelerated testing in light of its higher flux, but its smaller volume may be detrimental for a flowing loop. The O-position flux level was found to be insufficient for the purposes of this experiment; it is not recommended. In all the different salt candidates investigated, both the B and I-positions are found to able to reach adequate burnup conditions that are representative of the operating conditions inside proposed molten-salt reactor concepts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultrahigh heat flux plasma-facing components for magnetic fusion energy

Sandia and Ultramet partnered to design and test refractory metal plasma-facing components and heat exchangers for advanced, high-temperature power conversion systems. These devices consisted of high-temperature helium-to-helium and lithium-to-helium heat exchangers that operate with high efficiency due to the porous foam inserts used in the gas stream, which promote turbulence and provide extended surface area for enhanced convection. Single- and multi-channel helium panels and the Li-He heat exchanger were fabricated from either pure molybdenum, TZM, or tungsten. The design was carried out through an Ultramet subcontractor. The flow path was carefully tailored to minimize the pressure drop while maximizing the heat transfer. The single- and multi-channel helium panels were tested at Sandia's PMTF using an electron beam system and the closed helium flow loop. In 2006, a single-channel tungsten tube was successfully tested to an average heat flux of 14 MW/m{sup 2} with a localized peak of 22 MW/m{sup 2} along the axial centerline at the outer radius. Under this CRADA, multiple square-channel molybdenum components were successfully tested to heat flux levels approaching 8.5 MW/m{sup 2}. The three multi-channel prototypes experienced mechanical failure due to issues related to the design of the large unsupported span of the heated faceplates in combination with prototype material and braze selection. The Li-He heat exchanger was both designed and partially tested at the PMTF for helium and lithium flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Perspective on the oil-dominated gas hydrate plugging conceptual picture as applied to transient Shut-In/Restart

Gas hydrate formation is rarely an issue during continuous production conditions. Unplanned and/or extended shut-downs comprise the majority of scenarios where overlapping concern and uncertainty for gas hydrate blockages exist. To date, most experimental studies and theoretical analysis of gas hydrate formation derive from the steady-state conceptual picture. Yet, significant distinctions induced by phase separation and prolonged cooling suggest an altered conceptual picture is required for transient shut-in/restart operations. To address this outstanding issue, this work presents a conceptual picture for the base case of a non-surface active hydrocarbon undergoing cold restart without enacted mitigation efforts. First, phase separation upon shut-in leads to the localization of gas hydrate ingredients due to fluids density differences and pipeline inclination. Cooling to the seafloor temperature, then, induces gas hydrate film formation at the hydrocarbon interface and maximizes subcooling, resulting in rapid and confined gas hydrate growth occurring upon restart. Furthermore, this ultimately leads to plugging dominated by the deposition of porous, low conversion gas hydrate masses. Direct visual observations and results from Raman spectroscopy, hydrate contact angle and film growth, micromechanical force apparatus, rocking cell, and flow loop studies support the mechanisms outlined within each step. Similar to the influence provided by the original Colorado School of Mines steady-state conceptual picture that was introduced about 15 years ago, this transient counterpart builds a foundation that could inspire new directions of hydrate research and analysis in areas where uncertainty abounds.

02 PETROLEUM↗

SU-E-QI-06: Design and Initial Validation of a Precise Capillary Phantom to Test Perfusion Systems

Purpose: To design a precise perfusion phantom mimicking capillaries of the brain vasculature which could be used to test various perfusion protocols and algorithms which generate perfusion maps. Methods: A perfusion phantom was designed in Solidworks and built using additive manufacturing. The phantom was an overall cylindrical shape of diameter and height 20mm and containing capillaries of 200μm or 300μm which were parallel and in contact making up the inside volume where flow was allowed. We created a flow loop using a peristaltic pump and contrast agent was injected manually. Digital Subtraction Angiographic images and low contrast images with cone beam CT were acquired after the contrast was injected. These images were analyzed by our own code in LabVIEW software and Time-Density Curve, MTT and TTP was calculated. Results: Perfused area was visible in the cone beam CT images; however, individual capillaries were not distinguishable. The Time-Density Curve acquired was accurate, sensitive and repeatable. The parameters MTT, and TTP offered by the phantom were very sensitive to slight changes in the TDC shape. Conclusion: We have created a robust calibrating model for evaluation of existing perfusion data analysis systems. This approach is extremely sensitive to changes in the flow due to the high temporal resolution and could be used as a golden standard to assist developers in calibrating and testing of imaging perfusion systems and software algorithms. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Liquid-phase turbulence measurements in air-water two-phase flows using particle image velocimetry

Liquid-phase turbulence plays a vital role in determining various gas-liquid two-phase flow parameters, such as void fraction distribution, bubble morphology, bubble-bubble interactions, and interfacial area concentration. In this study, a two-phase flow database including both the gas- and liquid-phases measurements was developed focusing on three bubbly flow conditions in an air-water two-phase flow loop with a vertical one-inch diameter circular pipe test section. A particle image velocimetry (PIV) system integrating an optical phase separation method, i.e., the planar laser-induced fluorescence (PLIF) technique using fluorescent particles and optical filtration, was applied to measure the liquid-phase turbulence information, including the time-averaged velocity, Reynolds stress, and turbulent kinetic energy for the liquid phase. The PIV measurements were taken at three ports along the test section at 14.5, 51.5, and 88.5 pipe inner diameters downstream of a bubble injector. In addition, a double-sensor conductivity probe was used to measure radial distributions of the local time-averaged void fraction and gas velocity. The measured liquid-phase turbulence was used to benchmark Sato's turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. Lastly, in the two bubbly flows tested that have low void fractions being less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction.

42 ENGINEERING↗