Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow Conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Pressure Drop with Moving Contact Lines and Dynamic Contact Angles in a Hydrophobic Round Minichannel: Visualization via Synchrotron X-ray Imaging and Verification of Experimental Correlations

In hydrophobic mini- and microchannels, slug flow with moving contact lines is typically generated under various two-phase flow conditions. There is a significant pressure drop in this flow pattern with moving contact lines, which is closely related to the dynamic contact angles. Researchers have investigated dynamic contact angles experimentally for decades, but due to the limitations of visualization techniques, these experiments have typically been conducted in low Weber number regions (We < 10 –3 ). In this study, we clearly visualized the dynamic contact angles of a liquid slug in high Weber number regions (10 –3 < We <1) via synchrotron X-ray imaging with high temporal (~1000 fps) and spatial (~ 2 μm/pixel) resolutions. We precisely measured the pressure drop with moving contact lines in a hydrophobic minichannel (inner diameter = 1.018 mm). On the basis of our experimental data, we verified previous correlations for dynamic contact angles and explored the relationship between pressure drop with moving contact lines and dynamic contact angles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding spectral dependance of laser-induced damage precursors in dielectric materials (Abbreviated report_23-ERD-006)

High peak and average power laser systems are typically limited by the handling fluence of the optical components. In particular, the multilayer dielectric coatings are known to be much lower operational fluence than the more ideal bulk materials. In this project we proposed and succeeded in probing different established classes of damage prone precursors at different wavelengths to understand their fundamental laser damage response as a function of wavelength. This study helped to shed light on the fundamental physics of the non-linear precursors that govern laser damage phenomena for ns-regime pulsed laser damage. In this study, we utilized the onsite coating capabilities (VPL, IBS coating lab) to purposefully generate laser damage-prone precursors in hafnia-based coatings (both single and multi-layer coatings). Specifically, we engineered coatings with craze lines initiated by nodules, generated coatings with our xenon-based coating process to suppress nanobubble formation and generated hafnia coatings under controlled oxygen flow conditions to study hafnia sub-oxides and oxygen flow dependance. In these studies we found that craze lines are rife with precursors that are sensitive to ultra-violet light but not to infrared light; we found that the removal of nanobubbles helps with all wavelengths tested, but is most impactful for ultra-violet light; we also found that ultra-violet laser damage performance of hafnia is closely matched to oxygen flow rate, while the infrared performance may be slightly better at lower flow rates. During this LDRD we also successfully stood up a new laser damage testing capability, namely a wavelength agile damage test station to study the spectral response of known laser-induced damage precursors. This is a unique and important capability for Lawrence Livermore National Lab, allowing us to understand the spectral response of materials under high intensity irradiation and damage. This is a vital tool to understand non-linear optical response at wavelengths that we have previously been unable to test at.

36 MATERIALS SCIENCE↗

Corrosion Testing Trade Study on Testing Methods in Molten Salts

In assessing molten salt compatibility with structural materials, static testing is often reported because it is easy to conduct. However, in order to assess mass transfer, where material dissolves in the salt in the hot section and may precipitate out of the liquid in colder regions, a flowing salt experiment in a temperature gradient is needed. While a forced convection or pumped loop produces prototypic flowing conditions, it also is a multi-million dollar investment. Among the less expensive dynamic testing options, the thermal convection loop (TCL) was favored during the 1960’s development of molten salt reactor technology. Because the workforce and core facilities are currently available to conduct TCL experiments, it is the least expensive strategy to evaluate candidate structural alloys in flowing molten salt conditions.

36 MATERIALS SCIENCE↗

First principles simulation of reacting hypersonic flow over a blunt wedge

This article presents molecular-level analysis of a reactive, near-continuum, Mach 21 nitrogen flow over a blunt wedge using the direct molecular simulation (DMS) method. The flow conditions lead to internal energy excitation and dissociation in the flow field, resulting in thermal and chemical nonequilibrium in the flow. Thermal nonequilibrium in the vibrational mode is observed to extend to the molecular level, where the vibrational energy distributions at various points in the flow field are observed to be non-Boltzmann. Furthermore, this is the first reactive DMS calculation where the wall is assumed to be isothermal and full momentum accommodation of the particles is enforced, hence incorporating viscous wall effects. Since the DMS method uses a quantum mechanically generated interaction potential as its only modeling input, all thermochemical and transport properties of the flow field can directly be attributed to the ab initio potential energy surface. Using the DMS solution as a benchmark, this article assesses the performance of Navier–Stokes computational fluid dynamics solutions using lower fidelity two-temperature models. Two models are chosen as points of comparison: the well-known Park two-temperature model and the recently developed modified Marrone and Treanor model.

Mechanics↗

Development of fracture diagnostic methods for fluid distribution based on quantitative interpretation of distributed acoustic sensing and distributed temperature sensing

Multistage hydraulic fracturing design on horizontal wells has significantly evolved with larger fluid volume, more fracturing stages, and tighter perforation cluster spacing to efficiently stimulate unconventional reservoirs. From the published field observations, the recent fracturing design results in complex fracture networks or swarm of fractures. Fracture treatment evaluation is extremely challenging in such a case because of the large amount of variables in well completion and stimulation design. Combined measurements from different technologies can help in fracture diagnosis. Fluid distribution, either during fracture injection or during production, directly relates to the stimulation efficiency at the cluster level and at the stage level. Because it is unlikely in the real world to distribute the injected fluid uniformly among all the clusters, we need diagnostic techniques to generate the flow profile along a lateral. Fiber-optic measurements, such as distributed acoustic sensing (DAS) and distributed temperature sensing (DTS), are currently used to diagnose downhole flow conditions. This technology allows us to qualitatively confirm the fluid flow profile and other issues occurring downhole during fracturing such as leakage through plugs. For optimizing a fracturing design, we also need to understand how the design parameters are correlated with the stimulation efficiency. In this study, we combine two sets of models of DAS and DTS data interpretation for injected fluid volume distribution. The DAS is interpreted based on an empirical correlation between fluid flow rates and frequency band energy from the acoustic signals. The DTS is interpreted by performing temperature history match-based thermal energy conservation. Because of the completely different physics behind the interpretations, the confirmation of two interpretations provides confidence in fluid distribution.

Geochemistry & Geophysics↗

Finite element modeling of biomass hopper flow

Hoppers are widely used biomass handling devices that channel bulk biomass from storage to subsequent handling equipment. Jenike’s longstanding approach, based on the Mohr-Coulomb model, has been successfully used to design hoppers handling cohesionless granular materials such as grains and other agricultural produces. However, designing a hopper to ensure reliable biomass flow is found to be challenging due to cohesion, irregular particle shape, and bulk material elastoplasticity. This study aims to address the biomass handling engineering challenge with alternative constitutive material models concerning the flow behavior of bulk solids. Finite element modeling is an approach that allows for implementation of different material models, whose underlying constitutive theories assist in investigating the origin and manifestation of bulk mechanical behavior of granular materials. This study focuses on the incipient gravity hopper flow of two types of biomass feedstocks, i.e., ground corn stover and Douglas fir wood. Three widely used constitutive material models, i.e., Mohr-Coulomb model, modified Cam-Clay model, and Drucker-Prager/Cap model, are implemented. Using the flow pattern represented by the volume of biomass exhibiting more than 7% of axial strain (Kamath and Puri, 1999), the finite element model predicts that the bulk corn stover particulate material forms an arch, which represents a hampered transition from the static state to the dynamic flow-state out of the hopper, whereas bulk Douglas fir wood particulate material develops a reliable mass flow pattern. A laboratory scale hopper was used to experimentally determine the biomass flow conditions, which were subsequently compared with the predicted onset of flow by a finite element model (FEM). The developed FEM was found to correctly predict the initiation of mass flow for the milled Douglas fir wood, whereas corn stover was predicted to establish a strong core flow suggesting an unreliable handling characteristic. This observation aligns with the reported poor handling of milled corn stover.

09 BIOMASS FUELS↗

Feasibility Assessment of a Natural-Circulation Salt Irradiation Loop in the Advanced Test Reactor

Molten-salt reactors will likely require some level of irradiation testing as part of their licensing basis. An ideal experiment would consider the integrated effect of neutron flux and fission product generation in addition to circulating flow conditions. The feasibility of a natural-circulation irradiation salt loop in the Advanced Test Reactor (ATR) is assessed here. The flow is induced by the innovative combination of gas gaps and fin gaps along the capsule wall to fine-tune radial heat conductance, and therefore drive an axial temperature gradient across the experiment height. Following multiple design optimizations, a promising configuration has been identified. The 45-kW experiment would generate a 0.15 m/s flow velocity with 6 kg of fuel-bearing salt. This demonstrates the possibility of generating appreciable flow rates within manageable experimental conditions (e.g., total size and heat generation). An initial assessment of species mass tracking inside the experiment was also performed to gain an understanding of radionuclide behavior within the system. Results showed that significant quantities of Xe can be extracted in the off-gas (1.7 kCi) for an 8% bubble removal efficiency rate. Here, these results highlight the potential value of such experiments. Further work will involve detailed engineering drawings and analyses of the loop, as well as more computationally expensive modeling of species mass tracking.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Transfer Experiments of a 1st Stage Blade Cascade for Supercritical CO2 Oxy-Combustion Turbine Application

The results of internally cooled 1st stage blade (S1B) cascade testing in a supercritical CO2 environment is presented. The turbine blade design has been previously established for the end application of an oxy-combustion turbine operating in the Allam-Fetvedt cycle with turbine inlet conditions of 305 bar and 1150°C. The internally cooled blade features leading edge (LE) region impingement cooling, mid-section ribbed serpentine passages, and a pin-finned trailing edge (TE) region before cooling ejection holes. The geometry for the tested blade cascade has a cooled central blade with un-cooled blades on either side to match flowpath areas of the actual turbine. The flowpath reuses internal components previously employed for mid-section region ribbed serpentine passage experiments that established Nusselt number enhancement ratios over a range of Reynolds numbers from 100,000-400,000. New components include flow conditioning plates upstream and downstream of the blade cascade to adequately represent the flow field and blade external heat transfer coefficient profiles for the actual turbine. The cooled central blade utilizes uniform crystal temperature sensors (UCTS) with six sensors each on the blade pressure and suction surfaces distributed radially and from LE to TE. The post-processed UCTS quantified the maximum wall temperature seen at each installed sensor location. The test procedure consisted of establishing supercritical CO2 cooling flow temperature and flow rate and maintaining it throughout the test. The flow rate aims to match that for the actual in-service turbine blade design and is maintained through an orifice restriction to keep the pressure differential between internal cooling flow and external hot flow nearly constant. For the sCO2 flow path external to the blade, temperatures were ramped throughout the test via control of the test loop’s natural gas burner heater. The maximum temperature seen was 468°C and held constant for a duration of 10 minutes at which the blade metal temperature was predicted to be at its maximum before ramping down. For the turbine blade design for service inlet conditions, external flow path computational fluid dynamics (CFD) results and an internal cooling 1-D thermal and hydraulic flow network model using experimentally validated correlations served as thermal finite element (FE) boundary conditions to predict blade metal temperatures. These predicted temperatures were subsequently utilized in a structural FE model to predict blade life ratings dictated by Haynes 282 creep strength data, having a strong dependence on temperature. The boundary conditions experienced during testing are used in the same workflow and compared to the experimental results, with the goal of validating the analysis methodology and providing insight on the uncertainty in local metal temperature predictions.

20 FOSSIL-FUELED POWER PLANTS↗

Generative AI for Wind-Wave Inflows

Extreme wind-wave conditions can create dangerous or damaging environmental conditions for sea-based structures and watercrafts. However, the model of consistent, coupled wind-wave flow conditions is computational expensive, even for simple flow scenarios. This work examines the use of diffusion-based generative artificial intelligence tools to accelerate the generation of these two-phase flows and to characterize probabilities of various states to help with the generation of extreme patterns.

17 WIND ENERGY↗

Experimental investigation on heat transfer performance of drain water heat recovery heat exchangers

Water heating accounts for 18 % of residential energy consumption, and a substantial portion of this energy can be recovered through drain water heat recovery systems. Here, this paper investigates the heat transfer performance of drain water heat recovery heat exchangers. Two heat exchanger configurations were studied: vertical (gravity film exchanger) and horizontal. The heat recovery performance of the exchangers was quantified using sensible effectiveness and characteristic curves following the ε-NTU approach. Depending on the flow conditions, heat exchangers with a vertical configuration offered higher heat transfer effectiveness compared with the horizontal configuration under similar operating conditions. Furthermore, the results showed that properly designed and sized heat exchangers can effectively recover considerable amounts of waste heat from drains, depending on flow rates. Additionally, in the vertical heat exchanger configuration, low flow rates result in partially wet conditions, resulting in lower heat transfer effectiveness. Therefore, two distributor configurations are proposed to improve the heat transfer performance of vertically configured heat exchangers at low flow rates. The proposed distributor configurations and data presented in this paper will be useful in the design and development of drain water heat recovery systems in building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational fluid dynamics analysis of char conversion in Sandia’s pressurized entrained flow reactor

Design and analysis of practical reactors utilizing solid feedstocks rely on reaction rate parameters that are typically generated in lab-scale reactors. Evaluation of the reaction rate information often relies on assumptions of uniform temperature, velocity, and species distributions in the reactor, in lieu of detailed measurements that provide local information. This assumption might be a source of substantial error, since reactor designs can impose significant inhomogeneities, leading to data misinterpretation. Spatially resolved reactor simulations help understand the key processes within the reactor and support the identification of severe variations of temperature, velocity, and species distributions. In this work, Sandia’s pressurized entrained flow reactor is modeled to identify inhomogeneities in the reaction zone. Tracer particles are tracked through the reactor to estimate the residence times and burnout ratio of introduced coal char particles in gasifying environments. The results reveal a complex mixing environment for the cool gas and particles entering the reactor along the centerline and the main high-speed hot gas reactor flow. Furthermore, the computational fluid dynamics (CFD) results show that flow asymmetries are introduced through the use of a horizontal gas pre-heating section that connects to the vertical reactor tube. Computed particle temperatures and residence times in the reactor differ substantially from the idealized plug flow conditions typically evoked in interpreting experimental measurements. Furthermore, experimental measurements and CFD analysis of heat flow through porous refractory insulation suggest that for the investigated conditions (1350 °C, <20 atm), the thermal conductivity of the insulation does not increase substantially with increasing pressure.

47 OTHER INSTRUMENTATION↗

Near-Real-Time Statistical Analysis and Visualization of Streamflow from a Deep-Learning Rainfall-Runoff Model

Near-real-time (NRT) streamflow data are critical importance for timely water resources management. Here, we developed an open-source tool, FlowStats, for NRT streamflow analysis and visualization in Germany, based on NRT meteorological data from the German Weather Service and simulated streamflow from a long short-term memory neural network (LSTM). The LSTM model achieved very good overall performance, median NSE of 0.80 for the test period across 1,479 catchments. FlowStats provides options for deriving various streamflow statistics, from normal and abnormal streamflow detection to drought and flood analyses. An example analysis from FlowStats revealed widespread below-normal to extreme low-flow conditions across Germany from March to May 2025, which weakened from June to September 2025. Drought analysis for September 2025 highlighted severe to extreme drought conditions in northwestern Germany, while flood classifications indicated that high-flow events occurred in southwestern Germany. FlowStats can be used for various hydrological assessments to support water resources management.

Hydrological modeling↗

Generalized Analysis of Dynamic Flow Fouling on Heat Transfer Surfaces

Several energy applications involve flow of untreated heat transfer fluids that contain trace amounts of mineral salts, such as calcium carbonate and calcium sulfate, which show reverse solubility with temperature. The gradual accretion of these salts onto the heat transfer surfaces causes fouling that degrades thermal performance over time. While fouling of bare surfaces has been extensively studied, fouling of nonwetting superhydrophobic or liquid-infused surfaces is less understood, especially under dynamic flow conditions. This study presents a systematic experimental analysis to elucidate dynamic flow fouling of calcium carbonate and calcium sulfate on smooth, superhydrophobic and liquid-infused surfaces in a generalized manner. Here, copper tubes with modified inner surface wettability are fabricated and subjected to forced convection at different flow rates and fouling salt concentrations. Fouling characteristics of the two salts on the different surfaces are examined through microstructural analysis, and quantified in terms of asymptotic fouling resistance that measures the total extent of fouling, and a threshold time, which correlates to the onset of significant fouling. Using Taguchi design of experiments, the study reports, for the first time, closed-form analytical relationships for the asymptotic fouling thermal resistance and threshold time on the Reynolds number, dimensionless concentration of fouling agent and dimensionless infused liquid viscosity that represents the different surface types in a unified manner. It is shown that the analytical model accurately predicts the fouling characteristics in up to about 97% of the data, based on which contour maps of optimum surface designs for minimizing fouling resistance are presented. The results provide information on designing surfaces for reduced fouling or for estimating the fouling characteristics for a given surface in applications.

36 MATERIALS SCIENCE↗

Catalytic Consequences of Hierarchical Pore Architectures within MFI and FAU Zeolites for Polyethylene Conversion

The benefits of hierarchical zeolites for the conversion of bulky molecules like polymeric waste have been reported in the literature; however, the impact of mesopore sizes and connectivities on rates, product selectivities, and catalyst deactivation in the context of plastic upcycling has not been systematically probed. Here, in this study, we synthesized a suite of hierarchical MFI and FAU zeolites via desilication under varying conditions for metal-free polyethylene conversion reactions under batch and flow conditions (473–523 K). Polyethylene (solid) conversion rates (normalized by Bro̷nsted acid site density) were higher on hierarchical than parent microporous MFI regardless of mesopore connectivities, i.e., open or constricted, suggesting that the incorporation of mesopores facilitates diffusion of intermediate products to access medium-pore protons for successive scission events. Furthermore, higher branched:linear gaseous product ratios were produced on hierarchical than parent MFI, since mesopores allow for egress of bulkier molecules without undergoing further secondary events, e.g., isomerization back to linear alkanes/alkenes or beta scission. Solid conversion rates on hierarchical FAU synthesized via desilication with cetyltrimethylammonium bromide (CTABr), however, were not higher than parent FAU, likely because the presence of CTABr facilitates recrystallization of leached species to form composites (hierarchical FAU and ordered mesoporous materials) with more isolated mesopores. The stagnation in rates, despite increased mesopore volumes (>0.22 cm 3 g –1 ), highlights the importance of confinement effects provided by micropores for cleaving C–C bonds at modest reaction conditions. In situ 1 H MAS NMR performed on polyethylene with MFI zeolite show that PE isomerizes (and potentially deconstructs) at temperatures near 450 K, highlighting the role of Bro̷nsted acid sites in activating C–C bonds under mild reaction conditions. Catalyst recyclability studies showed that all catalysts undergo deactivation during plastic upcycling reactions, but to varying extents. Overall, hierarchical materials have better catalyst stability than parent materials, although the differences in stability between hierarchical and parent FAU are smaller than those for MFI. Taken together, these findings demonstrate how rates, selectivities, and catalyst deactivation from plastic upcycling reactions can be controlled via fine-tuning the identity and connectivity of mesopores.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facilitating Hydrogen Dissociation over Dilute Nanoporous Ti–Cu Catalysts

The dissociation of H 2 is an essential elementary step in many industrial chemical transformations, typically requiring precious metals. Here, we report a hierarchical nanoporous Cu catalyst doped with small amounts of Ti (npTiCu) that increases the rate of H 2 –D 2 exchange by approximately one order of magnitude compared to the undoped nanoporous Cu (npCu) catalyst. The promotional effect of Ti was measured via steady-state H 2 –D 2 exchange reaction experiments under atmospheric pressure flow conditions in the temperature range of 300–573 K. Pretreatment with flowing H 2 is required for stable catalytic performance, and two temperatures, 523 and 673 K, were investigated. The experimentally determined H 2 –D 2 exchange rate is 5–7 times greater for npTiCu vs the undoped Cu material under optimized pretreatment and reaction temperatures. The H 2 pretreatment leads to full reduction of Cu oxide and partial reduction of surface Ti oxide species present in the as-prepared catalyst as demonstrated using in situ ambient pressure X-ray photoelectron spectroscopy and X-ray absorption spectroscopy. The apparent activation energies and pre-exponential factors measured for H 2 –D 2 exchange are substantially different for Ti-doped vs undoped npCu catalysts. Density functional theory calculations suggest that isolated, metallic Ti atoms on the surface of the Cu host can act as the active surface sites for hydrogen recombination. Furthermore, the increase in the rate of exchange above that of pure Cu is caused primarily by a shift in the rate-determining step from dissociative adsorption on Cu to H/D atom recombination on Ti-doped Cu, with the corresponding decrease in activation entropy that it produces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Code Validation of SAM Using Forced and Natural Circulation Data from NACIE-UP Benchmark

Heavy liquid metals (HLMs) are promising candidates as coolants of Generation IV fast reactors due to their thermophysical properties. In the last decade, experimental work has been proposed as part of research and development efforts to develop such systems. In this context, researchers from the Brasimone Research Center have conducted many experiments using the Natural Circulation Experiment Upgrade (NACIE-UP) facility to study the thermofluid dynamic behavior of HLMs in rod bundle configurations with or without wire wrappers. This facility consists of a rectangular loop operated with lead-bismuth eutectic. Sensors across the loop monitor relevant parameters, i.e. temperatures, heat transfer, and flow conditions. Here, in the present work, we carefully select published data from NACIE-UP to validate the System Analysis Module (SAM), a modern system analysis code developed at Argonne National Laboratory. We developed one SAM model using specifications of the facility geometry and materials existing in relevant papers and reports. On top of that, these references provided the boundary conditions for simulating natural circulation and forced convection experiments in either steady or transient conditions. The SAM model simulates five test cases with diverse operating conditions. Ultimately, the code is proven to predict temperatures and mass flow rates that closely match the experiments. The discrepancies between numerical predictions and diverse transients are limited to a few degrees Celsius, showcasing that SAM is well suited for analyzing nuclear systems relying on HLM coolants.

advanced reactors↗

Evaluation of High Vacuum Pump for Tritium Service

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. Since turbomolecular pumps are used in tritium processing, it is thought that pumps similar to the turbomolecular pumps would be of interest. A newer model turbomolecular pump with a variable rotation speed has been identified for use in tritium processing. The turbomolecular pump, backed by a Metal Bellows MB-601 pump with the pump heads in series, was characterized for static and gas flow conditions to determine the suction pressure at various discharge pressures or flow rates for various gases.

42 ENGINEERING↗

Statorless mixed flow turbine for transonic pulsating inflow

Effective harvesting of power from high speed highly transient inflows such as the outflow of rotating detonation combustors (RDCs) is key to achieving their promised cycle efficiency step jump. To increase power density and efficiency simultaneously, a concept that can directly ingest transonic outflow, addressing the choking is needed, i.e. without additional transition elements. A new statorless design was assessed using a comprehensive approach to quantify all contributions to loss generation in transient flows, locally and globally. The turbine rotor was designed under steady flow conditions with a genetic algorithm. The comparison of power and loss generation between steady and unsteady flow results shows that a design methodology under steady-state conditions is suitable to characterize the performance of different designs. Three design families were further assessed under highly transient transonic conditions including traveling shock waves with a relative total pressure amplitude of 149.6% around the mean value and inflow angle variations from -26.5 deg to +51.8 deg. The oblique shock impinging on the pressure side (PS) of the turbine augments the shaft power extraction. When the oblique shock reflects between the pressure side and suction side (SS), its strength diminishes. This paper provides design guidelines on efficient turbine work extraction from the shocks emanating from detonation combustors.

rotating detonation engines↗