Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fixed grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Virtualized Logical Qubits: A 2.5D Architecture for Error-Corrected Quantum Computing

Current, near-term quantum devices have shown great progress in the last several years culminating recently with a demonstration of quantum supremacy. In the medium-term, however, quantum machines will need to transition to greater reliability through error correction, likely through promising techniques like surface codes which are well suited for near-term devices with limited qubit connectivity. We discover quantum memory, particularly resonant cavities with transmon qubits arranged in a 2.5D architecture, can efficiently implement surface codes with substantial hardware savings and performance/fidelity gains. Specifically, we virtualize logical qubits by storing them in layers of qubit memories connected to each transmon. Surprisingly, distributing each logical qubit across many memories has a minimal impact on fault tolerance and results in substantially more efficient operations. Our design permits fast transversal application of CNOT operations between logical qubits sharing the same physical address (same set of cavities) which are 6x faster than standard lattice surgery CNOTs. We develop a novel embedding which saves approximately 10x in transmons with another 2x savings from an additional optimization for compactness. Although qubit virtualization pays a 10x penalty in serialization, advantages in the transversal CNOT and in area efficiency result in fault-tolerance and performance comparable to conventional 2D transmon-only architectures. Our simulations show our system can achieve fault tolerance comparable to conventional two-dimensional grids while saving substantial hardware. Furthermore, our architecture can produce magic states at 1.22x the baseline rate given a fixed number of transmon qubits. Here, this is a critical benchmark for future fault-tolerant quantum computers as magic states are essential and machines will spend the majority of their resources continuously producing them. This architecture substantially reduces the hardware requirements for fault-tolerant quantum computing and puts within reach a proof-of-concept experimental demonstration of around 10 logical qubits, requiring only 11 transmons and 9 attached cavities in total.

quantum computing↗

From Modular ADMS to Plug-and-Play Ops: Distribution Grid Operations with Platform-Level Orchestration to Enable Ambitious App Hosting

The core function of the distribution grid is to provide electricity to consumers affordably, reliably, and securely. In pursuing these core objectives, distribution utilities are accountable to customers, regulators, and in some cases, shareholders. Other third parties such as aggregators and microgrids can also have a stake in the smooth operation of the grid. Each of these stakeholders has economic, business, and/or governance objectives that inform their expectations of the distribution grid. This multi-objective, multi-stakeholder environment creates tension that must be reconciled to successfully design and operate the distribution grid. Innovative companies are competing to bring high-tech solutions to electric utilities and their customers that address each of these objectives. Many developers of advanced distribution management systems (ADMS) and distributed energy resource management systems (DERMS) have adopted a modular architecture that allows grid operators to select functions and features according to their individual system needs. A modular platform also allows the solution provider to develop and integrate specific new product modules; however, the need to pursue multiple objectives with a fixed set of controllable devices makes integration expensive whether it is done at the product development stage or the deployment stage. This cost creates a significant barrier to adoption and can lengthen the product to market time of new solutions. To fundamentally address the complexity of system integration for distribution grid operations, the U.S. Department of Energy Office of Electricity has funded the GridAPPS-D project at PNNL, which streamlines integration by contributing to standards development, defining system architecture, applying advanced mathematics, and developing open-source software to demonstrate the concept of an open data-integration platform for distribution operations. The open data-integration platform concept enables system operators and solution providers to deploy ambitious, best-of-breed applications (or apps) without continually reengineering for integration. Ambitious apps developed by different solution providers will inevitably attempt to achieve different control objectives with the same set of controllable devices. If the open platform itself can resolve these conflicts in a way that achieves the best available outcomes for all apps, doesn’t restrict the ambitious design of apps, and ensures safe and secure operations, apps will be able to plug-and-play with the platform at the same time as other ambitious apps. In this paper, we describe a framework called App Deconfliction that empowers a platform to assign setpoints to controllable devices based on the values preferred by different apps (and even external stakeholder entities like customers or aggregators). The App Deconfliction framework is compatible with several methods for determining setpoint values. We present two methods based on game theory that provide a subtle built-in incentive structure for developers to adapt their apps to the fact that they will be operating in a moderated multi-app environment and to favor device setpoints that have the most effect on their objectives over those that have the least effect. Our simulation-based demonstrations have shown that game-theory-based deconfliction can lead to a 7% improvement in control space utilization compared to design-based methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Beyond Price Taker: Conceptual Design and Optimization of Integrated Energy Systems Using Machine Learning Market Surrogates

Future electricity generation systems must be optimized to provide flexibility that counteracts the variability of non-dispatchable renewable energy sources and ensures the reliability and safety of critical infrastructure, including the electric grid. The current state-of-the-art is to co-optimize the design and operation of integrated energy systems (IES) treating historical or predicted time-series electricity prices as fixed parameters. Recent literature has shown the limitations of this price taker assumption, which neglects how IES optimization decisions influence market outcomes. As such, this paper proposes a new optimization formulation that uses machine learning surrogate models, trained from a library of annual market operation simulations, to embed IES market interactions into the co-optimization problem directly. Using a thermal generator example built in the open-source IDAES computational environment, we show that the price taker approach routinely over-predicts annual revenues by 8% or more compared to a validation simulation, where the proposed approach has a typical relative error of 1% or less.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Re-evaluating probable maximum precipitation estimates: sensitivity to transposition domains and storm rotation using modern datasets

This study examines the sensitivity of Probable Maximum Precipitation (PMP) estimates to key methodological decisions embedded in the legacy approach adopted in the U.S. National Weather Service Hydrometeorological Reports No. 51 and No. 52. Although widely used for infrastructure design and risk regulation, fundamental aspects of PMP estimation—such as storm sample size, transposition domain, maximization procedures, and storm rotation—remain poorly constrained and lack formal guidance. Using the Red Rock watershed in Iowa as a case study, and leveraging the 2002–2023 NOAA Analysis of Record for Calibration (AORC) precipitation dataset, we systematically evaluate how each methodological choice, individually and in combination, influences PMP estimates. Our findings demonstrate that PMP is not a fixed physical upper bound but rather a modeling construct shaped heavily by user-defined assumptions. Notably, PMP values derived from modern gridded rainfall datasets can be substantially higher than the legacy estimate used in the original spillway design for Red Rock Dam. Decisions regarding storm sample size, domain extent, climatological window, and particularly storm rotation all contributed to higher PMP estimates. Storm rotation alone—a loosely constrained element in the current PMP practice—can amplify PMP by more than 25%. These results reveal the lack of standardized bounds in current PMP workflows and the need for systematic sensitivity and uncertainty analysis. As PMP estimation shifts toward probabilistic approaches, incorporating physically meaningful storm attributes will be key to developing more transparent, defensible methods for dam safety and climate-resilient infrastructure.

Probable maximum precipitation↗

High-resolution particle-in-cell simulations of two-dimensional Bernstein–Greene–Kruskal modes

We present two-dimensional (2D) particle-in-cell (PIC) simulations of 2D Bernstein–Greene–Kruskal modes, which are exact nonlinear steady-state solutions of the Vlasov–Poisson equations, on a 2D plane perpendicular to a background magnetic field, with a cylindrically symmetric electric potential localized on the plane. PIC simulations are initialized using analytic electron distributions and electric potentials from the theory. We confirm the validity of such solutions using high-resolutions up to a 20482 grid. We show that the solutions are dynamically stable for a stronger background magnetic field, while keeping other parameters of the model fixed, but become unstable when the field strength is weaker than a certain value. When a mode becomes unstable, we observe that the instability begins with the excitation of azimuthal electrostatic waves that ends with a spiral pattern.

Physics↗

Synchrophasor Data Anomaly Detection on Grid Edge by 5G Communication and Adjacent Compute

The fifth-generation mobile communication (5G) technology offers the opportunities to enhance the grid real-time monitoring. The 5G-enabled phasor measurement units (PMUs) features flexible positioning and cost-effective long-term maintenance, without constraints of fixing wire. This paper is the first to demonstrate the applicability of 5G in PMU communication, and the experiment was carried out at Verizon non-standalone testbed at Pacific Northwest National Laboratory (PNNL) Advanced Wireless Communication lab. The performance of 5G-enabled PMU communication setup is reviewed and discussed in this paper, and the paper presents a real-time dynamic linear model (DML) based synchrophasor data anomaly detection application. Last but not least, the practicability of implementing 5G for wide-area protection strategies is explored and discussed by analyzing the experimental results.

5G, Synchrophasor data, machine learning, anomaly ↗

A Cooperative Game Theory-based Approach to Under-frequency Load Shedding Control

This paper proposes a cooperative game theory-based under-frequency load shedding (UFLS) approach for frequency stability and control in power systems. UFLS is a crucial factor for frequency stability and control especially in power grids with high penetration of renewable energy sources and restructured power systems. Conventional UFLS methods, most of which are off-line, usually shed fixed amounts of predetermined loads based on a predetermined schedule which can lead to over or under curtailment of load. This paper presents a co-operative game theory-based two-stage strategy to effectively and precisely determine locations and amounts of loads to be shed for UFLS control. In the first stage, the total amount of loads to be shed, also referred to as deficit in generation or the disturbance power, is computed using the initial rate of change of frequency (ROCOF) referred to the equivalent inertial center. In the second stage, the Shapley value, one of the solution concepts of cooperative game theory, is used to determine load shedding amounts and locations. The proposed method is implemented on the reduced 9-bus 3-machine Western Electricity Coordinating Council (WECC) system and simulated on Real-time Digital Simulators (RTDS). The results show that the proposed UFLS approach can effectively return the system to normal state after disturbances.

42 ENGINEERING↗

Emergency Diesel Generator Reliability and Installation Energy Security

The U.S. Department of Defense’s (DoD’s) fixed installations - or military bases - are a critical element of national security. Military bases support the maintenance and deployment of weapons systems, training and mobilization of combat forces, and provide direct support to combat operations. Fixed installations do not operate without energy and they rely largely on electricity to support critical missions and functions. Installations are dependent on a commercial grid that is vulnerable to disruption due to severe weather, physical attacks, and cyberattacks. This report looks at the impact on the highest priority critical loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of Combined Lead Fast Reactor and Concentrating Solar Power Supercritical Carbon Dioxide Cycles to Demonstrate Feasibility, Efficiency Gains, and Cost Reductions

Solar power has innate issues with weather, grid demand and time of day, which can be mitigated through use of thermal energy storage for concentrating solar power (CSP). Nuclear reactors, including lead-cooled fast reactors (LFRs), can adjust power output according to demand; but with high fixed costs and low operating costs, there may not be sufficient economic incentive to make this worthwhile. We investigate potential synergies through coupling CSP and LFR together in a single supercritical CO 2 Brayton cycle and/or using the same thermal energy storage. Combining these cycles allows for the LFR to thermally charge the salt storage in the CSP cycle during low-demand periods to be dispatched when grid demand increases. The LFR/CSP coupling into one cycle is modeled to find the preferred location of the LFR heat exchanger, CSP heat exchanger, sCO 2 -to-salt heat exchanger (C2S), turbines, and recuperators within the supercritical CO 2 Brayton cycle. Three cycle configurations have been studied: two-cycle configuration, which uses CSP and LFR heat for dedicated turbocompressors, has the highest efficiencies but with less component synergies; a combined cycle with CSP and LFR heat sources in parallel is the simplest with the lowest efficiencies; and a combined cycle with separate high-temperature recuperators for both the CSP and LFR is a compromise between efficiency and component synergies. Additionally, four thermal energy storage charging techniques are studied: the turbine positioned before C2S, requiring a high LFR outlet temperature for viability; the turbine after the C2S, reducing turbine inlet temperature and therefore power; the turbine parallel to the C2S producing moderate efficiency; and a dedicated circulator loop. While all configurations have pros and cons, use of a single cycle offers component synergies with limited efficiency penalty. Using a turbine in parallel with the C2S heat exchanger is feasible but results in a low charging efficiency, while a dedicated circulator loop offers flexibility and near-perfect heat storage efficiency but increasing cost with additional cycle components.

14 SOLAR ENERGY↗

Investigating Multi-Microgrid Black Start Methods Using Grid-Forming Inverters: Preprint

This paper examines state-of-the-art microgrid (MG) black-start technologies with high IBR penetrations and proposes black-start and interconnection methods for 100% grid-forming (GFM) inverter-based MGs. A multiple-microgrid approach is proposed and compared to the existing methods in a 4-bus, 12-GFM inverter simulation test setup. This investigation involves intelligent synchronization units called "synchrobreakers," which enable the synchronization of multiple MGs based on their terminal measurements. MGs in this setup are held at different loading levels and comprise averaged models of GFM inverters with ideal voltage sources. The results of the black-start techniques are compared, and conclusions are drawn to better prepare MG planners and DSOs for the next-generation GFM inverter-based multi-MG black-start procedures.

black start↗

Integrated solution techniques for security constrained unit commitment problem

Apparatus and methods are disclosed for solving Mixed Integer Programming (MIP) problems, such as Security Constrained Unit Commitment (SCUC) problems used by power grid authorities to perform day-ahead market clearing. In certain examples, a plurality of threads of a software tool implementing a concurrent optimizer can be executed concurrently and sequentially to generate new solutions to a SCUC problem for an upcoming planning horizon. Data can be shared among the concurrently executing threads, such as intermediate/incumbent solutions and hints regarding the fixing of variables and constraints to reduce the size of the SCUC problem. In some examples, the threads are seeded with historical solutions from prior planning horizons. The software tool can select a best solution from the solutions generated by the threads, and determine dispatch instructions for a device coupled to the power grid for the upcoming planning horizon based at least in part on the selected solution.

Pan, Feng↗

Investigating Multi-Microgrid Black Start Methods Using Grid-Forming Inverters

This paper examines state-of-the-art microgrid (MG) black-start technologies with grid-forming (GFM) inverter-based resources (IBRs) and proposes black start and interconnection methods for 100% inverter-based MGs. A multiple-MG approach is proposed and compared to the existing methods in a 4-bus, 12-GFM inverter simulation test setup. This investigation involves intelligent synchronization units that enable the autonomous synchronization of multiple MGs based on their terminal measurements. MGs in this setup are held at different loading levels and comprise averaged models of GFM inverters. The results of the black-start techniques are compared, and conclusions are drawn to better prepare MG planners and distribution system operators for next-generation, multi-MG, GFM inverter-based, black-start procedures.

black start↗

Reconductoring Economic and Financial Analysis Tool (REFA) v1.0

REFA is designed to help transmission planners better understand the financial, environmental and economic benefits of reconductoring upgrades, using traditional or advanced conductors. More specifically, the tool enables grid planners and utilities to demonstrate the entire lifetime value of reconductoring projects, providing potential justifications for projects with higher Capex - the purchase of long-term physical or fixed assets used in a business's operations. Existing tools are designed to compare technical aspects of different conductor applications. They typically do not allow a cost-benefit analysis over the lifetime of the conductor's operations.

Heleno, Miguel↗

Power System Recovery Coordinated with (Non-)Black-Start Generators

Power restoration is an urgent task after a black-out, and recovery efficiency is critical when quantifying system resilience. Multiple elements should be considered to restore the power system quickly and safely. This paper proposes a recovery model to solve a direct-current optimal power flow (DCOPF) based on mixed-integer linear programming (MILP). Since most of the generators cannot start independently, the interaction between black-start (BS) and non-black-start (NBS) generators must be modeled appropriately. The energization status of the NBS is coordinated with the recovery status of transmission lines, and both of them are modeled as binary variables. Also, only after an NBS unit receives the cranking power through connected transmission lines, will it be allowed to participate in the following system dispatch. The amount of cranking power is estimated as a fixed proportion to the maximum generation capacity. The proposed model is validated on several test systems, as well as a 1393-bus representation system of the Puerto Rican electric power grid. Test results demonstrate how the recovery of NBS units and damaged transmission lines can be optimized, resulting in an efficient and well-coordinated recovery procedure.

Zhao, Meng↗

ECAR-6585 MARVEL Core Support Structure Analysis: Project #33526

Idaho National Laboratory (INL) is developing a small microreactor to produce electrical power utilizing a small nuclear core and stirling engines for power output under the Microreactor Application Research Validation and Evaluation (MARVEL) program. The MARVEL Reactor (Figure 1) will be installed in the Transient Reactor Test (TREAT) Facility. Walsh Engineering Services, PC (WES) has contracted with the INL to detail the final design. There are six main systems in the MARVEL, one of which is the Fuel and Core System (FCS). The FCS contains a subsystem–the Core Support Structures Subsystem (CSS)–that supports and orients each of the 36 nuclear fuel pins in the MARVEL Reactor System. The FCS (apart from the fixed Beryllium Oxide radial reflectors) is shown in light green and is depicted in more detail in Figure 1 and Figure 2. The main subject of this analysis is the lower grid plate, which is the principal item in the CSS which supports the fuel, see Figure 3. Additionally, the upper grid plate thermal expansion of the upper grid plate is presented in Appendix A.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Renewable Energy Potential Model: Hawaii Geothermal Supply Curves

This dataset extends the development of the Renewable Energy Potential (reV) model to include geothermal energy, with a specific focus on Hawaii. Provided here are the results of two scenarios that were modeled for geothermal energy in Hawaii: binary enhanced geothermal systems (EGS) at a depth of 2.5 km and hydrothermal binary systems at a depth of 1.5 km. The resource data for both scenarios were derived from Lautze and Haskins (2024) using an exponential method. The PFA probability of heat map was used as a look up table for which temperature gradient to use (Lautze and Haskins, 2024). The dataset provides geospatial and techno-economic details for evaluating geothermal energy potential. It includes spatial coordinates, estimated capacity factors, developable area, resource potential, and annual energy production metrics. Economic details such as levelized cost of electricity (LCOE), site development costs, transmission costs, and fixed-charge rates are also included. The reV model, originally developed for wind and solar energy, incorporates these variables to evaluate deployment constraints related to land use, environmental and cultural factors, and grid integration.

15 GEOTHERMAL ENERGY↗

Hestia-SWIFL: hourly anthropogenic fossil fuel CO2 and heat on the 2km WRF grid, version 1.1

The Hestia-SWIFL version 1.1 anthropogenic heat (AH) and fossil fuel CO2 (FFCO2) emissions data product represent emissions due to the combustion of fossil fuel and cement production within the state of Arizona from 2019 to 2022. This product was developed as part of the Southwest Urban Corridor Integrated Field Laboratory (SW-IFL) project, which aims to provide new knowledge and tools that address extreme heat, air quality, climate change and related urban environmental issues by integrating high-resolution observations, modeling, and civic engagement. The emissions are generated using a bottom-up/engineering approach and are tied to results generated by the Vulcan Project version 4, an effort to quantify space/time-resolved FFCO2 & AH emissions for the entire United States landscape. A large number of data sources are combined to best estimate the emissions at fine scales such as air quality emissions data, traffic flow data, building information, sociodemographic information, and fuel statistics. The AH product provides emissions for two emissions sources (transportation and point source emissions) in units of Watts per hour per square meter (W/m2) per year (annual files) or per hour (hourly files). The FFCO2 product provides emissions from nine individual emission sectors as well as the total, and in units of tons of carbon (tC) per grid cell per year or per hour. The output made available here places the native spatial resolution of the Hestia FFCO2 & AH emissions data product (points, lines, and polygons) into a regularized 2km x 2km grid at hourly and annual temporal resolutions, and stored in netCDF files. The exact spatial extent is defined by the ASU Weather Research Forecast (WRF) simulation grid. All data are processed using R/Python pm high-performance computing system. 2-27-2026 updates: Bugs in airport hourly profile (both AH and FFCO2) and building spatial patterns (FFCO2 only) were fixed. Hourly emissions are reprocessed for all years to reflect those changes.

54 ENVIRONMENTAL SCIENCES↗

Updated sustainability status of cadmium telluride thin‐film photovoltaic systems and projections

This paper provides a comprehensive assessment of the up-to-date life-cycle sustainability status of cadmium-telluride based photovoltaic (PV) systems. Current production modules (Series 6 and Series 7) are analyzed in terms of their energy performance and environmental footprint and compared with the older series 4 module production and current single-crystalline Silicon (sc-Si) module production. For fixed-tilt systems with Series 6 modules operating under average US irradiation of 1800 kWh/m 2 /year, the global warming potential (GWP) is reduced from 16 g CO 2eq /kWh in Series 4 systems to 10 CO 2 eq /kWh in Series 6 systems. For operation in US-SW irradiation of 2300 kWh/m 2 /year, the GWP is reduced from 11 to 8 CO 2eq /kWh and for 1-axis tracking systems operating in Phoenix, Arizona, with point-of array irradiation of 3051 kWh/m 2 /year the GWP is reduced to 6.5 CO 2eq /kWh. Similar reductions have happened in all environmental indicators. Energy payback times (EPBT) of currently installed systems range from 0.6 years for fixed–tilt ground–mounted installations at average US irradiation at latitude tilt installations to 0.3 years for one-axis trackers at high US-SW irradiation, considering average fossil-fuel dominated electricity grids with fuel to electricity conversion efficiency of 0.3. The resulting energy return on energy investment (EROI) also depends on the conversion efficiency of the electricity grid and on the operation life expectance. For a 30-year operational life and grid conversion efficiency of 0.3, EROI ranges from 50 (at US average irradiation) to 70 for US-SW irradiation. The EROI declines with increased grid conversion efficiency; for CdTe PV operating in south California with grid conversion efficiency of 49%, the EROI is about 50 and is projected to fall to 30 when the state's 2030 target of 80% renewable energy penetration materializes. Material alternatives that show a potential of further reductions in degradation rates and materials for enhanced encapsulation that would enable longer operation lives have also been investigated. A degradation rate of 0.3%/year, which has been verified by accelerated testing, is assumed in 30-year scenarios; this is projected to be reduced to 0.2%/year in the near-term and potentially to 0.1%/year in the longer term. With such low degradation rates and enhanced edge-sealing, modules can last 40- to 50-years. Consequently, all impact indicators will be proportionally reduced while EROI will increase. This detailed LCA was conducted according to ISO standards and IEA PVPS Task 12 guidelines. Furthermore, the study revealed that the choices of system models, methods and temporal system boundaries can significantly impact the results and points out to the need to include assumptions regarding these choices in the “transparency in reporting” requirements listed in the IEA PVPS Task 12 Guidelines.

14 SOLAR ENERGY↗