Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fiber Lens”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Optical properties and zero photoelastic constant of ns{sup 2}-type metal cation containing oxide glasses

Zero photoelasticity and the relevant optical properties in binary RO–SiO{sub 2} (R = Sn, Pb) and R′{sub 2}O{sub 3}–SiO{sub 2} (R′ = Sb, Bi) and ternary Bi{sub 2}O{sub 3}–B{sub 2}O{sub 3}–SiO{sub 2} glasses were systematically studied. The zero photoelastic silicate glass leads to zero stress-induced birefringence, providing application to an optical lens, a filter, a beam splitter, and a fiber optic sensor without stress-induced birefringence. In this study, a variety of zero photoelastic binary silicate and ternary borosilicate glasses with optical bandgaps of 3.1–3.9 eV containing highly polarized ns{sup 2}-type cations are reported.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Sub miniaturized laser doppler velocimeter sensor

A miniaturized laser Doppler velocimeter is formed in a housing that is preferably 3 mm in diameter or less. A laser couples light to a first diffractive optical element that is formed on the fiber end. The light is coupled to a lens that also includes a diffractive optical element. The same lens is also used to collect receive light, and receives includes another diffractive optical element to collect that received light.

Gharib, Morteza↗

Optoelectronic System Measures Distances to Multiple Targets

An optoelectronic metrology apparatus now at the laboratory-prototype stage of development is intended to repeatedly determine distances of as much as several hundred meters, at submillimeter accuracy, to multiple targets in rapid succession. The underlying concept of optoelectronic apparatuses that can measure distances to targets is not new; such apparatuses are commonly used in general surveying and machining. However, until now such apparatuses have been, variously, constrained to (1) a single target or (2) multiple targets with a low update rate and a requirement for some a priori knowledge of target geometry. When fully developed, the present apparatus would enable measurement of distances to more than 50 targets at an update rate greater than 10 Hz, without a requirement for a priori knowledge of target geometry. The apparatus (see figure) includes a laser ranging unit (LRU) that includes an electronic camera (photo receiver), the field of view of which contains all relevant targets. Each target, mounted at a fiducial position on an object of interest, consists of a small lens at the output end of an optical fiber that extends from the object of interest back to the LRU. For each target and its optical fiber, there is a dedicated laser that is used to illuminate the target via the optical fiber. The targets are illuminated, one at a time, with laser light that is modulated at a frequency of 10.01 MHz. The modulated laser light is emitted by the target, from where it returns to the camera (photodetector), where it is detected. Both the outgoing and incoming 10.01-MHz laser signals are mixed with a 10-MHz local-oscillator to obtain beat notes at 10 kHz, and the difference between the phases of the beat notes is measured by a phase meter. This phase difference serves as a measure of the total length of the path traveled by light going out through the optical fiber and returning to the camera (photodetector) through free space. Because the portion of the path length inside the optical fiber is not ordinarily known and can change with temperature, it is also necessary to measure the phase difference associated with this portion and subtract it from the aforementioned overall phase difference to obtain the phase difference proportional to only the free-space path length, which is the distance that one seeks to measure. Therefore, the apparatus includes a photodiode and a circulator that enable measurement of the phase difference associated with propagation from the LRU inside the fiber to the target, reflection from the fiber end, and propagation back inside the fiber to the LRU. Because this phase difference represents twice the optical path length of the fiber, this phase difference is divided in two before subtraction from the aforementioned total-path-length phase difference. Radiation-induced changes in the photodetectors in this apparatus can affect the measurements. To enable calibration for the purpose of compensation for these changes, the apparatus includes an additional target at a known short distance, located inside the camera. If the measured distance to this target changes, then the change is applied to the other targets.

Liebe, Carl Christian↗

Solid-state Laser Development for the in Situ Spectroscopic Europa Explorer Instrument

The in Situ Spectroscopic Europa Explorer (iSEE) instrument is an ultra-compact laser-enabled Raman spectrometer instrument that meets the top-level science requirements for multiple future planetary in situ missions to explore the surface and atmospheric chemistry of planetary bodies across the Solar System. Enceladus, Europa, the Moon, Mars, and Venus are some of the primary targets for future NASA missions to search for extraterrestrial life and potentially habitable environments beyond Earth, further our understanding of the timing and formation of the Solar System and identify potentially viable economic resources such as water and/or valuable metal assets. We report on the advancement and space flight qualification of a compact, robust, solid-state laser operating at 515 nm that serves as the excitation source for the iSEE investigation. The iSEE instrument is being developed under a NASA Maturation of Instruments for Solar System Exploration (MatISSE) program. The iSEE laser is a diode pumped 1030 nm Yb:YAG microchip laser with a second harmonic generator to achieve an output wavelength of 515 nm and coupled to a multi-mode fiber for delivery to the Raman spectrometer probe. The fundamental 1030 nm laser operates at a pulse repetition frequency (PRF) of 1-10 kHz with pulse energy of 95 μJ and ~800 ps pulse width. A 15 mm long Type II KTP crystal is used for second harmonic generation from 1030 nm to 515 nm. The residual fundamental 1030 nm is separated from the 515 nm beam using a pair of dichroic filters. A focusing lens couples the 515 nm beam to the optical fiber to produce an output laser pulse energy of 20 μJ. A custom vacuum fiber feedthrough assembly was designed with two 105 μm core fibers, and two 200 μm core fibers. One fiber is needed for coupling the laser to the iSEE instrument, and the additionally fibers provide redundancy and design flexibility. The laser enclosure is pressurized with >1 atm of clean dry air. The laser has been designed to minimize the size, weight, and power (SWaP) for a lander instrument with minimal resources. The laser will go through environmental testing including vibration and thermal vacuum testing for space flight qualification. Here we discuss the design, trade studies, performance, and environmental qualificationtesting of the iSEE laser.

Solid state laser, Raman spectrometer, visible las↗

Laser-Induced Incandescence Calibration via Gravimetric Sampling

Various beam imaging and/or sheet forming optics delivered light at 1064 nm from a pulsed Nd:YAG laser for use either as a beam of 3 mm radius or as a laser sheet. Imaging measurements were performed with a grated intensified array camera equipped with an ultraviolet f4.5 lens and a 40 mm extension tube. Point measurements were performed using an ultraviolet 250 mm focal length lens to collect and focus the laser induced incandescence (LII) signal into a 1 meter long quartz optical fiber which directed the LII signal to a 1/4 meter monochromator. An aperture preceding the lens restricted the signal collection region to 1 cm along the laser beam at the center of the gravimetric chimney. Signals from the PMT were processed by a boxcar integrator whereas the images were captured digitally using a frame-grabber with 16 MByte of on-board memory. Both 'point' and planar measurements were made with detector gates of 250 ns to minimize possible morphology bias in collection of the LII signal. Additionally, the imaging measurements were performed with broadband spectral collection of the LII signal to maximize the signal and again minimize any potential effects of morphology dependent heating and/or cooling rates. Digital delay generators controlled the firing of he laser, detector gates and data acquisition. Neutral density filters were used for both sets of measurements to maintain signal levels within linear dynamic ranges of the detectors, the range being determined prior to experiments.

VanderWal, R. L.↗

A Compact Fiber Optic Eye Diagnostic System

A new fiber optic probe developed for determining transport properties of sub-micron particles in fluid experiments in a microgravity environment has been applied to study different parts of an eye. The probe positioned in front of an eye, delivers a low power (approximately few microW) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like materials in the vitreous humor. In a clinical setting, the probe can be mounted on a standard slit-lamp apparatus simply using a Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.

Ansari, Rafat R.↗

A Compact Fiber Optic Eye Diagnostics System

A new fiber optic probe development for determining transport properties of sub-micron particles in fluids experiments in a microgravity environment has been applied to study different parts of the eye. The probe positioned in front of an eye, delivers a low power (approximately a few mu W) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. For a clinical use, the probe is mounted on a standard slit-lamp apparatus simply using Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.

Ansari, Rafat R.↗

MACS, An Instrument, and a Methodology for Simulations and Global Measurements of the Coronal Electron Temperature and the Solar Wind Velocity on the Solar Corona

The determination of the radial and latitudinal temperature and wind profiles of the solar corona is of great importance in understanding the coronal heating mechanism and the dynamics of coronal expansion. Cram presented the theory for the formation of the K-coronal spectrum and identified two important observations. He observed the existence of temperature sensitive anti-nodes at certain wavelengths in the theoretical K-coronal spectra. The anti-nodes are separated by temperature-insensitive nodes. Remarkably, Cram showed that the wavelengths of the nodes and anti-nodes are almost independent of altitude above the solar limb. Because of these features, Cram suggested that the intensity ratios at two anti-nodes could be used as a diagnostic of the electron temperature in the K-corona. Based on this temperature diagnostic technique prescribed by Cram a slit-based spectroscopic study was performed by Ichimoto et al. on the solar corona in conjunction with the total solar eclipse of 3 Nov 1994 in Putre, Chile to determine the temperature profile of the solar corona. In this thesis Cram's theory has been extended to incorporate the role of the solar wind in the formation of the K-corona, and we have identified both temperature and wind sensitive intensity ratios. The instrument, MACS, for Multi Aperture Coronal Spectrometer, a fiber optic based spectrograph, was designed for global and simultaneous measurement of the thermal electron temperature and the solar wind velocity in the solar corona. The first ever experiment of this nature was conducted in conjunction with the total solar eclipse of 11 Aug 1999 in Elazig, Turkey. In this instrument one end of each of twenty fiber optic tips were positioned in the focal plane of the telescope in such a way that we could observe conditions simultaneously at many different latitudes and two different radial distances in the solar corona. The other ends of the fibers were vertically aligned and placed at the primary focus of the collimating lens of the spectrograph to obtain simultaneous and global spectra on the solar corona. By isolating the K-coronal spectrum from the spectrum recorded by each fiber the temperature and the wind sensitive intensity ratios were calculated to obtain simultaneous and global measurements of the thermal electron temperature and the solar wind velocity. We were successful in obtaining reliable estimates of the coronal temperature at many positions in the corona. This is the first time that simultaneous measurements of coronal temperatures have been obtained at so many points. However due to instrumental scattering encountered during observations, reliable estimates of the wind velocity turned out to be impossible to obtain. Although remedial measures were taken prior to observation, this task proved to be difficult owing to the inability to replicate the conditions expected during an eclipse in the laboratory. The full extent of the instrumental scattering was apparent only when we analyzed the observational sequence. Nevertheless the experience obtained from this very first attempt to simultaneously and globally measure both the wind velocity and the temperature on the solar corona have provided valuable information to conduct any future observations successfully.

Reginald, Nelson L.↗

Hybrid catadioptric system for advanced optical cavity velocimetry

A probe including reflector is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface by the probe and then reflected back from the surface, is Doppler shifted by the moving surface, collected into probe, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to one or more lens groups and a reflector, such as a parabolic reflector having a mirrored interior surface.

36 MATERIALS SCIENCE↗

GBT20, a 20.48 Gbps PAM4 Optical Transmitter Module for Particle Physics Experiments

We present a pluggable radiation-tolerant 4-level Pulse-Amplitude-Modulation (PAM4) optical transmitter module called GBT20 (Giga-Bit Transmitter at 20 Gbps) for particle-physics experiments. GBT20 has an OSFP or firefly connector to input 16-bit data each at 1.28 Gbps. The GBT20 drives a VCSEL die with an LC lens or a VCSEL TOSA and interfaces an optical fiber with a standard LC connector. The minimum module, including the host connector, occupies 41 mm x 13 mm x 6 mm. At 20.48 Gbps, the minimum Transmitter Dispersion Eye Closure Quaternary (TDECQ) is around 0.7 dB. The power consumption is around 164 mW in the low-power mode. The SEE cross-section is below 7.5x10^(-14) cm^2. No significant performance degrades after a TID of 5.4 kGy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robust incoherent fiber optic bundle decoder

Apparatus and method for calibrating an incoherent fiber optic bundle for use in transmitting visual or infrared coherent images. The apparatus includes a computer, a computer video monitor, an objective lens adjacent to the input end of the bundle, a second lens adjacent the output end of the bundle, and a CCD camera. The camera transmits video data to the monitor to produce an illuminated fiber optic image. The coordinates for the center of each fiber is found through an imaging process and the output fibers coordinates are related to the input fiber coordinates and processed in the computer to produce a mapping lookup-table (LUT) unique to the specific fiber bundle. Remapping of the LUT due to changes in the lens focus, CCD camera, or the addition of an infrared filter is accomplished by a software utility in the computer.

Roberts, Hilary E.↗

Galaxy and Mass Assembly: A Comparison between Galaxy–Galaxy Lens Searches in KiDS/GAMA

Strong gravitational lenses are a rare and instructive type of astronomical object. Identification has long relied on serendipity, but different strategies—such as mixed spectroscopy of multiple galaxies along the line of sight, machine-learning algorithms, and citizen science—have been employed to identify these objects as new imaging surveys become available. We report on the comparison between spectroscopic, machine-learning, and citizen-science identification of galaxy–galaxy lens candidates from independently constructed lens catalogs in the common survey area of the equatorial fields of the Galaxy and Mass Assembly survey. In these, we have the opportunity to compare high completeness spectroscopic identifications against high-fidelity imaging from the Kilo Degree Survey used for both machine-learning and citizen-science lens searches. We find that the three methods—spectroscopy, machine learning, and citizen science—identify 47, 47, and 13 candidates, respectively, in the 180 square degrees surveyed. These identifications barely overlap, with only two identified by both citizen science and machine learning. We have traced this discrepancy to inherent differences in the selection functions of each of the three methods, either within their parent samples (i.e., citizen science focuses on low redshift) or inherent to the method (i.e., machine learning is limited by its training sample and prefers well-separated features, while spectroscopy requires sufficient flux from lensed features to lie within the fiber). These differences manifest as separate samples in estimated Einstein radius, lens stellar mass, and lens redshift. The combined sample implies a lens candidate sky density of ∼0.59 deg{sup −2} and can inform the construction of a training set spanning a wider mass–redshift space. A combined approach and refinement of automated searches would result in a more complete sample of galaxy–galaxy lens candidates for future surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

Systematic Effects in Galaxy-Galaxy Lensing with DESI

The Dark Energy Spectroscopic Instrument (DESI) survey will measure spectroscopic redshifts for millions of galaxies across roughly $14,000 \, \mathrm{deg}^2$ of the sky. Cross-correlating targets in the DESI survey with complementary imaging surveys allows us to measure and analyze shear distortions caused by gravitational lensing in unprecedented detail. In this work, we analyze a series of mock catalogs with ray-traced gravitational lensing and increasing sophistication to estimate systematic effects on galaxy-galaxy lensing estimators such as the tangential shear $\gamma_{\mathrm{t}}$ and the excess surface density $\Delta\Sigma$ . We employ mock catalogs tailored to the specific imaging surveys overlapping with the DESI survey: the Dark Energy Survey (DES), the Hyper Suprime-Cam (HSC) survey, and the Kilo-Degree Survey (KiDS). Among others, we find that fiber incompleteness can have significant effects on galaxy-galaxy lensing estimators but can be corrected effectively by up-weighting DESI targets with fibers by the inverse of the fiber assignment probability. Similarly, we show that intrinsic alignment and lens magnification are expected to be statistically significant given the precision forecasted for the DESI year-1 data set. Our study informs several analysis choices for upcoming cross-correlation studies of DESI with DES, HSC, and KiDS.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Measurement of Mass Flow of a Two-Phase Fluid

An optoelectronic system utilizes wavelength-dependent scattering of light for measuring the density and mass flow of a two-phase fluid in a pipe. The apparatus was invented for original use in measuring the mass flow of a two-phase cryogenic fluid (e.g., liquid hydrogen containing bubbles of hydrogen gas), but underlying principles of operation can readily be adapted to non-cryogenic two-phase fluids. The system (see figure) includes a laser module, which contains two or more laser diodes, each operating at a different wavelength. The laser module also contains beam splitters that combine the beams at the various wavelengths so as to produce two output beams, each containing all of the wavelengths. One of the multiwavelength output beams is sent, via a multimode fiberoptic cable, to a transmitting optical coupler. The other multiwavelength output beam is sent, via another multimode fiber-optic cable, to a reference detector module, wherein fiber-optic splitters split the light into several multiwavelength beams, each going to a photodiode having a spectral response that is known and that differs from the spectral responses of the other photodiodes. The outputs of these photodiodes are digitized and fed to a processor, which executes an algorithm that utilizes the known spectral responses to convert the photodiode outputs to obtain reference laser-power levels for the various wavelengths. The transmitting optical coupler is mounted in (and sealed to) a hole in the pipe and is oriented at a slant with respect to the axis of the pipe. The transmitting optical coupler contains a collimating lens and a cylindrical lens that form the light emerging from the end of the fiber-optic cable into a fan-shaped beam in a meridional plane of the pipe. Receiving optical couplers similar to the transmitting optical couplers are mounted in the same meridional plane at various longitudinal positions on the opposite side of the pipe, approximately facing the transmitting optical coupler along the same slant. Light collected by each receiving optical coupler is sent, via a multimode fiber-optic cable, to a detector module similar to the reference detector module. The outputs of the photodiodes in each detector module are digitized and processed, similarly to those of the reference detector module, to obtain indications of the amounts of light of each wavelength scattered to the corresponding receiving position. The value for each wavelength at each position is also normalized to the reference laser-power level for that wavelength. From these normalized values, the density and the mass flow rate of the fluid are estimated.

Wiley, John↗

A Digital Twin Approach to Study Additive Manufacturing Processing Using Embedded Optical Fiber Sensors and Numerical Modeling

One of the major challenges for metal-powder-based additive manufacturing is measuring and mitigating residual strain induced during the manufacturing processes. This article reports distributed fiber optic sensors embedded in Inconel alloy components as experimental means to validate numerical models of additive manufacturing process. Electroplating was used to deposit a metal protective jacket onto standard telecom single-mode fibers for strain measurements, Fiber sensors were embedded in an Inconel alloy substrate using the laser engineered net shaping (LENS) process. Here by using a Rayleigh-scattering optical frequency domain reflectometer (OFDR), temperature changes, and residual strain in the metal substrate were monitored with 5 mm spatial resolution during the LENS process. Using finite element analysis, temperature and strain profiles induced by the LENS deposition processes were also numerically studied. Discrepancies between the simulated temperature and strain profiles and those measured directly were less than 10%. Results presented in this article demonstrates a digital twin approach to fuse modeling results with distributed fiber sensor measurement data to study additive manufacturing process toward design and fabrication process optimization.

36 MATERIALS SCIENCE↗

Protection against UV and X-ray cataracts using dynamic light scattering

Static and dynamic light scattering (SLS and DLS) analysis was used to investigate the aggregation of lens proteins in a hyperbaric oxygen (HBO)/guinea pig in vivo model for nuclear cataract. Nuclear cataract, an opacity which occurs in the center of the lens, is a major type of human maturity-onset cataract for which the cause is not well-understood. HBO is commonly used in major hospitals for treating complications such as poor wound healing due to impaired blood circulation. It is known that treatment of human patients with HBO for extended periods of time can produce nuclear cataract. Guinea pigs, initially 18 months old, were treated with HBO (2.5 atm of 100% O2 for 2.5 hr) 3x per week for 7 months to increase tie level of lens nuclear light scattering. Age-matched animals were used for controls. The eyes of the animals were analyzed in vivo using an integrated static and DLS fiber optic probe in collaboration with the NASA group. DLS in vivo was used to measure the size of lens proteins at 50 different locations across the optical axis of the guinea pig lens.

Giblin, Frank J.↗

High resolution color band pyrometer ratioing

The sensing head of a two-color band ratioing pyrometer of a known type using a fiber optic cable to couple radiation to dual detector photodiodes is improved to have high spatial resolution by focusing the radiation received through an objective lens (i.e., by focusing the image of a target area) onto an opaque sheet spaced in front of the input end of the fiber optic cable. A two-mil hole in that sheet then passes radiation to the input end of the cable. The detector has two channels, one for each color band, with an electronic-chopper stabilized current amplifier as the input stage followed by an electronic-chopper stabilized voltage amplifier.

Bickler, Donald B.↗