Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fast counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Molybdenum oxide and sulfide active sites for isobutane dehydrogenation with methanol as a probe molecule

Molybdenum oxides and sulfides are alternative catalysts for several reactions, including alkane dehydrogenation. Correlations have been developed between reactivity and structure, but it is difficult to compare different catalysts without determining numbers of active sites. Here, methanol temperature programmed surface reaction (TPSR) is applied to bulk MoS 2 and a series of supported molybdenum oxides and sulfides used for isobutane dehydrogenation. Rates and deactivation behavior are similar between supported molybdenum oxides and sulfides. Coking increases with loading and correlates well with the fraction of Mo-based CO 2 -forming sites from methanol TPSR. Normalizing isobutane dehydrogenation rates by formaldehyde-forming sites unifies rates over oxide and sulfide materials. Further, these measurements confirm earlier hypotheses that MoS 2 and higher loadings of oxides and sulfides are intrinsically fast catalysts, but they have few active sites and are prone to coking. In general, methanol TPSR is proposed as an accessible route to count sites on both supported oxides and sulfides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-energy neutron spectroscopy with thick silicon detectors

The high-energy neutron component of the space radiation environment in thick structures such as the International Space Station contributes to the total radiation dose received by an astronaut. Detector design constraints such as size and mass have limited the energy range of neutron spectrum measurements in orbit to about 12 MeV in Space Shuttle studies. We present a new method for high-energy neutron spectroscopy using small silicon detectors that can extend these measurements to more than 500 MeV. The methodology is based on measurement of the detector response function for high-energy neutrons and inversion of this response function with measured deposition data to deduce neutron energy spectra. We also present the results of an initial shielding study performed with the thick silicon detector system for high-energy neutrons incident on polyethylene.

Non-NASA Center↗

The Faint "Heartbeats" of IGR J17091-3624: An Exceptional Black Hole Candidate

We report on the first 180 days of Rossi X-Ray Timing Explorer observations of the outburst of the black hole candidate IGR Jl7091-3624. This source exhibits a broad variety of complex light curve patterns including periods of strong flares alternating with quiet intervals. Similar patterns in the X-ray light curves have been seen in the (up to now) unique black hole system GRS 1915+105. In the context of the variability classes defined by Belloni et al. for GRS 1915+105, we find that JGR J17091-3624 shows the nu, rho, alpha, lambda, Beta, and mu classes as well as quiet periods which resemble the chi class, all occurring at 2-60 keY count rate levels which can be 10-50 times lower than observed in GRS 1915+\05. The so-called rho class "heartbeats" occur as fast as every few seconds and as slow as approx 100 s, tracing a loop in the hardness-intensity diagram which resembles that previously seen in GRS 1915+\05. However, while GRS 1915+105 traverses this loop clockwise, IGR Jl7091-3624 does so in the opposite sense. We briefly discuss our findings in the context of the models proposed for GRS 1915+105 and find that either all models requiring near Eddington luminosities for GRS 1915+105-like variability fail, or IGR Il7091-3624 lies at a distance well in excess of 20 kpc, or it harbors one of the least massive black holes known( <3 solar M).

Altamirano, D.↗

Small, Fast TES Microcalorimeters with Unprecedented X-ray Spectral Performance

Driven initially by the desire for X-ray microcalorimeter arrays suitable for imaging the dynamic solar corona, we have developed a transition-edge-sensor (TES) microcalorimeter optimization that exhibits a unique combination of high spectral resolving power and a wide X-ray bandpass. These devices have achieved spectral performance of dE approximately 1.3 eV FWHM at 1.5 keV, 1.6 eV at 6 keV, and 2.0 eV at 8 keV, using small TESs (e.g., approximately 35 micron x 35 micron) that operate in a regime in which the superconducting transition is highly current dependent. In order to accommodate high X-ray count rates, the devices sit directly on a solid substrate instead of on membranes, and we use an embedded heatsinking layer to reduce pixel-to-pixel crosstalk. We will present results from devices with a range of TES and absorber sizes, and from device wafers with varied embedded heatsink materials. This contribution will focus on count-rate capabilities, including a discussion of the trade-off between count rate and energy resolution, and the heatsinking design. We will also present preliminary tests of array readout using a code-division multiplexed SQUID readout scheme, which may be necessary to enable large arrays of these fast devices.

Eckart, M. E.↗

Verification and Validation Tests of Gamma Library of MC2-3 for Coupled Neutron and Gamma Heating Calculation

For the accurate assessment of the heat generation rate in fast reactors, the gamma library of MC2 -3 and the MC2 -3 + GAMSOR procedure employing the coupled neutron and gamma heating calculation has been thoroughly verified against Monte Carlo results and validated using the ZPPR-15D gamma dose measurement data. NJOY outputs are post-processed in a consistent way with the NJOY procedure to avoid any missing data or double counting of data. Prompt heating for 379 out of 391 isotopes in the gamma library was verified against MCNP6.2 to within 1% relative error in total heating for most isotopes. For both a simple one-dimensional slab problem representing a sodium cooled fast reactor and the Experimental Breeder Reactor II (EBR-II) benchmark problem, the root-mean-square values of assembly power error were less than 0.5% for fuel assemblies, ~1% in blankets and ~1 to ~3% in reflectors compared to MCNP6.2 results. The most plausible cause for the 3% error in a reflector assembly is believed to be the error in the multigroup neutron cross sections for the reflector assembly. For validation, gamma doses measured with thermoluminiscent dosimeters (TLDs) in the ZPPR-15D experiment were calculated using GAMSOR. Due to the uncertainty in the TLD measurement with regards to the energy deposition of photons and neutrons, the validation data leads to a 12.7% uncertainty on the experimental measurement. With this uncertainty bound, the calculated doses all fell within one standard deviation of the measured value. Combined with the accurate calculation of reaction rate distributions and neutron spectrum measurements, these results indicate good agreement for the neutron and gamma heating calculations that were performed.

coupled neutron and gamma heating↗

Solar maximum mission/ultraviolet spectrometer and polarimeter studies

This final report for NASA Contract No. NAS8-35921 describes various studies performed for the Ultraviolet Spectrometer and Polarimeter (UVSP) experiment, one of several instruments on the Solar Maximum Mission (SMM) satellite which was launched on 14 February 1980. The UVSP consisted primarily of a Gregorian telescope and an Ebert-Fastie spectrometer with a polarimeter that could be inserted into the light path. The spacecraft and most of the instruments, including the UVSP, operated successfully until 23 November 1980, when part of the SMM attitude control system (fine pointing control) failed. The UVSP was then unable to observe the Sun until 18 April 1984, when the SMM was visited by the space shuttle and the attitude control module was replaced by astronauts. The SMM mission ended when the spacecraft reentered the atmosphere of the Earth and was thereby destroyed on 2 December 1989. The topics covered in this report include the following: (1) ultraviolet stellar polarimetry (probably the first such attempted measurement); no polarization as detected and the upper limits, based on the sensitivity as determined by the observed count rate, are rather high; (2) an investigation into the possible position of the UVSP wavelength drive after it became stuck on 26 April 1985; (3) fast timing tests for sit-and-state observations involving one or two detectors; (4) development of computer subroutines to allow the calculation of the component of the SMM spacecraft orbital velocity along the line of sight to the Sun at any desired time during the 1984/1985 period when the UVSP wavelength drive was operating properly; (5) listing of published research papers; (6) description of the UVSP catalog of observations; and (7) description of UVSP calibration report and data users guide.

Henze, William, Jr.↗

Investigation of fast and efficient lossless compression algorithms for macromolecular crystallography experiments

Structural biology experiments benefit significantly from state-of-the-art synchrotron data collection. One can acquire macromolecular crystallography (MX) diffraction data on large-area photon-counting pixel-array detectors at framing rates exceeding 1000 frames per second, using 200 Gbps network connectivity, or higher when available. In extreme cases this represents a raw data throughput of about 25 GB s −1 , which is nearly impossible to deliver at reasonable cost without compression. Our field has used lossless compression for decades to make such data collection manageable. Many MX beamlines are now fitted with DECTRIS Eiger detectors, all of which are delivered with optimized compression algorithms by default, and they perform well with current framing rates and typical diffraction data. However, better lossless compression algorithms have been developed and are now available to the research community. Here one of the latest and most promising lossless compression algorithms is investigated on a variety of diffraction data like those routinely acquired at state-of-the-art MX beamlines.

36 MATERIALS SCIENCE↗

Synergetic Use of the WSR-88D Radars, GOES-R Satellites, and Lightning Networks to Study Microphysical Characteristics of Hurricanes

Abstract This study analyzes the microphysics and precipitation pattern of Hurricanes Harvey (2017) and Florence (2018) in both the eyewall and outer rainband regions. From the retrievals by a satellite red–green–blue scheme, the outer rainbands show a strong convective structure while the inner eyewall has less convective vigor (i.e., weaker upper-level reflectivities and electrification), which may be related to stronger vertical wind shear that hinders fast vertical motions. The WSR-88D column-vertical profiles further confirm that the outer rainband clouds have strong vertical motion and large ice-phase hydrometeor formation aloft, which correlates well with 3D Lightning Mapping Array source counts in height and time. From the results from this study, it is determined that the inner eyewall region is dominated by warm rain, whereas the external rainband region contains intense mixed-phase precipitation. External rainbands are defined here as those that reside outside of the main hurricane circulation, associated with surface tropical storm wind speeds. The synergy of satellite and radar dual-polarization parameters is instrumental in distinguishing between the key microphysical features of intense convective rainbands and the warm-rain-dominated eyewall regions within the hurricanes. Substantial amounts of ice aloft and intense updrafts in the external rainbands are indicative of heavy surface precipitation, which can have important implications for severe weather warnings and quantitative precipitation forecasts. The novel part of this study is to combine ground-based radar measurement with satellite observations to study hurricane microphysical structure from surface to cloud top so as to fill in the gaps between the two observational techniques.

Meteorology & Atmospheric Sciences↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Phase Recovery and Locking in a PPM Laser Communication Link

Free-space optical communication holds great promise for future space missions requiring high data rates. For data communication in deep space, the current architecture employs pulse position modulation (PPM). In this scheme, the light is transmitted and detected as pulses within an array of time slots. While the PPM method is efficient for data transmission, the phase of the laser light is not utilized. The phase coherence of a PPM optical signal has been investigated with the goal of developing a new laser communication and ranging scheme that utilizes optical coherence within the established PPM architecture and photon-counting detection (PCD). Experimental measurements of a PPM modulated optical signal were conducted, and modeling code was developed to generate random PPM signals and simulate spectra via FFT (Fast Fourier Transform) analysis. The experimental results show very good agreement with the simulations and confirm that coherence is preserved despite modulation with high extinction ratios and very low duty cycles. A real-time technique has been developed to recover the phase information through the mixing of a PPM signal with a frequency-shifted local oscillator (LO). This mixed signal is amplified, filtered, and integrated to generate a voltage proportional to the phase of the modulated signal. By choosing an appropriate time constant for integration, one can maintain a phase lock despite long dark times between consecutive pulses with low duty cycle. A proof-of-principle demonstration was first achieved with an RF-based PPM signal and test setup. With the same principle method, an optical carrier within a PPM modulated laser beam could also be tracked and recovered. A reference laser was phase-locked to an independent pulsed laser signal with low-duty-cycle pseudo-random PPM codes. In this way, the drifting carrier frequency in the primary laser source is tracked via its phase change in the mixed beat note, while the corresponding voltage feedback maintains the phase lock between the two laser sources. The novelty and key significance of this work is that the carrier phase information can be harnessed within an optical communication link based on PPM-PCD architecture. This technology development could lead to quantum-limited efficient performance within the communication link itself, as well as enable high-resolution optical tracking capabilities for planetary science and spacecraft navigation.

Aveline, David C.↗

Fast digital lossy compression for X-ray ptychographic data

Increases in X-ray brightness from synchrotron light sources lead to a requirement for higher frame rates from hybrid pixel array detectors (HPADs), while also favoring charge integration over photon counting. However, transfer of the full uncompressed data will begin to constrain detector design, as well as limit the achievable continuous frame rate. Here a data compression scheme that is easy to implement in a HPAD's application-specific integrated circuit (ASIC) is described, and how different degrees of compression affect image quality in ptychography, a commonly employed coherent imaging method, is examined. Using adaptive encoding quantization, it is shown in simulations that one can digitize signals up to 16383 photons per pixel (corresponding to 14 bits of information) using only 8 or 9 bits for data transfer, with negligible effect on the reconstructed image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photon-Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST

The gravity from the quantum entanglement of space-time (GQuEST) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present a practicable interferometer design featuring a novel photon-counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent “geontropic” quantum gravity models. The accelerated accrual of Fisher information offered by the photon-counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design, thus, enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 3C 279 Campaign of Winter 1999: A Gamma-Optical Correlation?

Preliminary results are presented from the gamma-optical campaign of January-February 1999 on 3C 279. During this period we obtained good optical sampling of the source, the best ever for a gamma-bright OVV quasar. Its large and fast variations have been compared with the gamma-ray fluxes obtained simultaneously by Energy Gamma Ray Experiment Telescope (EGRET), on Compton Gamma Ray Observatory (CGRO). Despite rather poor counting statistics in the gamma-ray data, a fair correlation is found, with the gamma variations following those in the optical by 3-4 days. This is the first time such a significant day-scale correlation has been observed between the optical and gamma emissions from a OVV quasar. Its implications are currently under study.

Hartman, R. C.↗

Applications of activation analysis to geochemical, meteoritic and lunar studies.

The application of activation analysis techniques to the analysis of cosmological materials, i.e., terrestrial, tektitic, meteoritic, and lunar matter, is reviewed. Elemental determinations can be made by instrumental fast-neutron and thermal-neutron activation analysis, photonuclear and charged-particle activation analysis, and by radiochemical neutron activation analysis. Partition-coefficient methods, autoradiography studies, gamma-gamma coincidence counting, and age determination by neutron activation are discussed. Attention is given to K-Ar and I-Xe dating of meteorites.

Showalter, D. L.↗

Lunar and Planetary Science XXXVI, Part 10

The Problem of Incomplete Mixing of Interstellar Components in the Solar Nebula: Very High Precision Isotopic Measurements with Isoprobes P and T. Finally: Presolar Graphite Grains Identified in Orgueil. Basaltic Ring Structures as an Analog for Ring Features in Athabasca Valles, Mars. Experimental Studies of the Water Sorption Properties of Mars-Relevant Porous Minerals and Sulfates. Silicon Isotope Ratio Variations in CAI Evaporation Residues Measured by Laser Ablation Multicollector ICPMS. Crater Count Chronology and Timing of Ridged Plains Emplacement at Schiaparelli Basin, Mars. Martian Valley Networks and Associated Fluvial Features as Seen by the Mars Express High Resolution Stereo Camera (HRSC). Fast-Turnoff Transient Electromagnetic (TEM) Field Study at the Mars Analog Site of Rio Tinto, Spain. Time Domain Electromagnetics for Mapping Mineralized and Deep Groundwater in Mars Analog Environments. Mineralogical and Seismological Models of the Lunar Mantle. Photometric Observations of Soils and Rocks at the Mars Exploration Rover Landing Sites. Thermal Infrared Spectral Deconvolution of Experimentally Shocked Basaltic Rocks Using Experimentally Shocked Plagioclase Endmembers.

Source record↗

Neutron Measurements at the Lunar Surface (NMLS)

The Neutron Measurement System (NMS-Lunar) is an instrument payload manifested on Astrobotic’s Peregrine Mission One (M1). Astrobotic Mission One will land at Lacus Mortis (~44oN, 254oE). Astrobotic will fly up to fourteen NASA payloads to the lunar surface in addition to other payload customers on M1. NMS-Lunar is a re-design of the MSFC Fast Neutron Spectrometer (FNS) currently operating on the ISS. The design of NMS-Lunar enables operation on the lunar surface, integration onto the Peregrine lander, and measurement of thermal neutron count rates on the lunar surface. The primary science objectives for NMS-Lunar is to provide ground truth of mapped neutron data from the Lunar Reconnaissance Orbiter and Lunar Prospector missions. Neutrons are created when galactic cosmic rays interact with the lunar regolith, and can provide valuable elemental composition information.

Haviland, H. Fuqua↗

Determining Research Priorities for Astronomy Using Machine Learning

We summarize the first exploratory investigation into whether Machine Learning (ML) techniques can augment science strategic planning. We find that an approach based on Latent Dirichlet Allocation (LDA) using abstracts drawn from high-impact astronomy journals may provide a leading indicator of future interest in a research topic. We show two topic metrics that correlate well with the high-priority research areas identified by the 2010 National Academies’ Astronomy and Astrophysics Decadal Survey. One metric is based on a sum of the fractional contribution to each topic by all scientific papers (“counts”) while the other is the Compound Annual Growth Rate (CAGR) of counts. These same metrics also show the same degree of correlation with the whitepapers submitted to the same Decadal Survey. Our results suggest that the Decadal Survey may under-emphasize fast growing research. A preliminary version of our work was presented by Thronson et al. (2021).

Astronomy↗

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗