Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY SYNCHRONIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Frequency Stability Enhancement in a Fully Solar Power Grid: A Case Study on the Saudi Model

Recently, renewable energy sources (RES) such as solar photovoltaic (PV) have been recognized for their significant potential. Several studies have explored the issue of frequency stability with high RES penetration. A significant observation related to this issue is the decline in the weighted short circuit ratio (WSCR), which has the potential to adversely affect system stability. This research uniquely focuses on the gradual transition of the Saudi Electricity Company (SEC) system to a fully integrated solar PV grid, offering insight and methodology that can be adapted for other power systems. While a variety of mitigation methods are available, synchronous condensers (SC) were used in this study to stabilize grid frequency, and their implementation has been shown to improve the overall performance of the system. In response to the observed decline in WSCR, a comprehensive short circuit analysis was applied across all regions in the Saudi power grid model to evaluate the reduction in short circuit power and highlight areas requiring enhancement. Finally, scenarios illustrating frequency response with a gradual increase in SCR were analyzed, with the objective of establishing a stable, fully solar PV power system that is resilient to sudden power grid disturbances.

14 SOLAR ENERGY↗

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structural Impact of Grid-Forming Inverters on Power System Coherency

This paper addresses the following fundamental research question: how does the integration of grid-forming inverters (GFMs) replacing conventional synchronous generators (SGs) impact the slow coherent eigen-structure and the low frequency oscillatory behavior of future power systems? Due to time-scale separated dynamics, generator states inside a coherent area synchronize over a fast time-scale due to stronger coupling, while the areas themselves synchronize over a slower time scale. Our mathematical analysis shows that due to the large-scale integration of GFMs, the weighted Laplacian structure of the frequency dynamics is preserved, however, the entries of the Laplacian may be significantly modified based on the location and penetration levels of the GFMs. This can impact and potentially significantly alter the coherency structure of the system. We have validated our findings with numerical results using the IEEE 68-bus test system.

Mukherjee, Sayak [BATTELLE (PACIFIC NW LAB)]↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV-Fed Smart Inverters for Mitigation of Voltage and Frequency Fluctuations in Islanded Microgrids

The presence of low-inertia distributed generation (DG) units makes islanded microgrids vulnerable to voltage and frequency variations. Besides, the considerable difference between the inertia of synchronous-based and inverter-based DGs results in a power imbalance between supply and demand during abnormal conditions. As a result, both voltage and frequency of microgrid ac-bus start oscillating which might have severe consequences such as blackouts. This paper deploys the traditional controller of photovoltaic (PV) units to improve the dynamic behavior of islanded microgrids by suppressing the voltage and frequency fluctuations. To this end, an adaptive piecewise droop (APD) characteristic is proposed and employed in PV units to attain a faster balance between generation and consumption during transients, leading to an enhanced frequency response. Besides, the reactive-power control loop is equipped with a droop characteristic which enables the PV units to inject/absorb reactive power during transients and participate in voltage-profile enhancement of the system. Case study results are presented using PSCAD/EMTDC to confirm the validity of proposed method in improving the dynamics of islanded microgrids.

Pilehvar, Mohsen S.↗

Extraordinary frequency stabilization by resonant nonlinear mode coupling

Here, we show that a self-sustained oscillator with a frequency-selective element operating with two nonlinearly coupled modes can achieve a level of frequency stability well beyond that available using single-mode operation. The system of interest consists of a self-sustained oscillator based on a nonlinear primary mode that is coupled via an internal resonance to a passive secondary mode. Analysis of a generic model for this resonance with both additive and multiplicative noises reveals that the stability improvements accrue from two sources: (i) nonlinear frequency veering in the primary mode, a classical analogue to quantum-level repulsion, that eliminates amplitude-to-frequency noise conversion; and (ii) phase cleaning of the oscillator through an intrinsic phase constraint arising from synchronization of the modes. This latter effect can significantly reduce the effects of intrinsic frequency fluctuations of the primary mode, which are not accessible by any known strategy using single-mode operation. The theoretical predictions are supported by experimental measurements of a microelectromechanical systems-based oscillator that demonstrate a reduction in oscillator line width of several orders of magnitude. This approach offers a means of optimizing frequency stability in self-sustained oscillators, which has direct implications for applications in timekeeping and sensing.

36 MATERIALS SCIENCE↗

Implementing Inertial Control for PMSG-WTG in Region 2 Using Virtual Synchronous Generator with Multiple Virtual Rotating Masses

With the increasing integration of renewable energy, the problems associated with a deteriorating grid frequency profile and potential power system instability have become more significant. In this paper, the inertial control algorithm using a virtual synchronous generator (VSG) is implemented on a Type 4 permanent magnet synchronous generator (PMSG) wind turbine generator (WTG). The overall nonlinear dynamic model and its small-signal linearization of the PMSG-WTG using a VSG is established and comprehensively analyzed. Inevitably, the direct application of the VSG introduces a large inertia, which causes conflict between the fast variance of available wind power and inverter control with slow dynamics, particularly in Region 2 of the wind turbine. Aiming to address such issues, a VSG with multiple virtual rotating masses is proposed to improve the active power tracking performance as well as to boost the inertial control of a VSG. The inertial responses are verified in a modified 10-MVA IEEE 14-bus microgrid system. The assessment of the simulation results demonstrates the applicability of the VSG on renewable energy generation units.

17 WIND ENERGY↗

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Forming Inverter: Laboratory-Scale Hardware Test Bed Setup and Weak Grid Operation

In recent times, the concept of grid forming inverters has gained popularity. Grid forming inverters have proven to be a promising alternative to the grid following inverters. In this paper, we present the hardware test bed implementation of grid forming inverter in islanding mode as well as in grid connected mode. The control structure includes inverter-level inner current control and outer voltage control, and plant-level P - f and Q - V droop control. The Q - V droop provides the voltage command, whereas P - f droop provides the frequency command and is also key for the synchronization process. While it is straightforward to set up the test bed for the islanded operation, it is a challenging process to set up the grid-forming inverter in the grid-connected mode. We present the key technologies and demonstrate the start-up process and weak grid operation using the hardware experiment results. Results from EMT model developed in MATLAB/SimPowerSystems are also presented for side-by-side comparison.

Mittal, Ratik↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

Virtual Synchronous Generator Control of Multi-port Autonomous Reconfigurable Solar Plants (MARS)

Multi-port autonomous reconfigurable solar power plant (MARS) is an integrated concept for integration of solar photovoltaic (PV) and energy storage systems (ESS) to transmission alternating current (ac) grid and high-voltage direct current (HVdc) links. The integrated development incorporates advanced control methods to provide enhanced grid ancillary services such as fast frequency responses and dynamic voltage support. In this paper, the virtual synchronous generator (VSG) control algorithm of MARS is discussed. The proposed VSG-based control enables enhanced synthetic inertial response and flexible frequency response characteristics of hybrid PV and ESS power plants in accordance with grid ancillary service requirements. Multi-port power electronics interface allows controlled emergency power support from MARS to local transmission ac grid and remote grid through the HVdc link. The performance of VSG control is validated using a reduced-order model of MARS in Simulink. Methods for estimating grid ancillary service capabilities of MARS are also discussed.

Pan, Jiuping↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables: Preprint

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds after disturbance. To address this challenge, this paper proposes a frequency stability unit commitment constraint considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Thus, this paper first analyzes a frequency nadir differential equation that considers SG governor model and three kinds of FFR provided by IBRs. A system frequency nadir estimation framework is developed with consideration of various conventional SG and IBR models. The accuracy of this frequency estimation framework is validated by largest N-1 contingency simulation result of a real island system. Then, the adaptive inertia frequency stability unit commitment constraint is derived from sensitivity analysis method. Finally, we demonstrate the effectiveness of our developed constraints with one year day-ahead unit commitment results of the real island system.

fast frequency response↗

Lifetime-Limited Interrogation of Two Independent 27 Al + Clocks Using Correlation Spectroscopy

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the 1 S 0 ↔ 3 P 0 transition in 27 Al + . By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12 × 10 15 Hz. Here, the observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s 3 P 0 state lifetime and represents a measurement instability of (1.8 ± 0.5) × 10 –16 /√τ/s for averaging periods longer than the probe duration when dead time is negligible.

74 ATOMIC AND MOLECULAR PHYSICS↗

Integration of fixed-frequency and FM-CW (frequency-modulated continuous-wave) reflectometers for coincident turbulence measurements on LTX- β (Lithium Tokamak eXperiment- β )

The fixed-frequency and frequency-modulated continuous-wave (FM-CW) reflectometers on LTX-β (Lithium Tokamak eXperiment-β) have been configured to use the same transmission lines and antenna arrays for coincident views of the core and edge plasma. The fixed-frequency channels (13.1–20.5 and 20–40 GHz, tunable between discharges) provide time-resolved measurements of density fluctuations, while the FM-CW channels (13.1–20.2 and 19.5–33.5 GHz) measure the density profile and fluctuations, with high spatial resolution and a sampling rate determined by the frequency sweep interval (5 μs). Data from both reflectometers are synchronously acquired to simultaneously leverage the wide bandwidth and high spatial resolution of the respective systems. Experiments showed that mutual crosstalk interference is momentary and does not diminish the capability of either system. Spectral analysis indicated broad power spectra (several hundreds of kHz) and suggests that the signals from the FM-CW system are consistent with under-sampled fixed-frequency signals. Radial correlations were explored using data from the two reflectometers, as well as from the FM-CW system alone. The core channels showed high levels of agreement between these two comparisons, suggesting that the data from the reflectometers are interchangeable for statistical estimates. For the edge channels, comparisons using data from the FM-CW reflectometer alone showed significant decorrelation due to time lag caused by the finite frequency up-sweep duration. Alternatively, this effect is eliminated when cross-correlating data from the different reflectometers. Finally, these results highlight the advantages of operating the fixed-frequency and FM-CW reflectometers in this manner, where the combined system can overcome the limitations of each separate system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Examining the Economic Optimality of Automatic Generation Control

The automatic generation control (AGC) system is temporally situated between economic dispatch and synchronous generator dynamics, and its primary role is to regulate frequency within and tie-line flows between control areas. Given appropriate choice of participation factors (feed-forward controller gains that govern the disaggregation of the area-level power requirement to individual generators), the AGC can be engineered to nudge system dynamics toward a steady-state operating point corresponding to economic optimality. This paper establishes necessary and sufficient conditions under which a widely accepted choice of participation factors guarantees the alignment of steady-state synchronous generator outputs with a global minimum of a prototypical economic dispatch problem. In so doing, it resolves several ambiguities and formalizes technical assumptions governing the role of the standard AGC architecture in the context of economic dispatch and steady-state operation. Numerical case studies tailored to a modified version of the New England 39-bus 10-machine test system validate the theoretical results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Polyphase Rotary Transformer for Field Excitation of Electric Machines

This paper presents the magnetic design of a high-frequency three-phase rotary transformer for Wound Rotor Synchronous Motors (WRSM). The traditional DC field excitation of the WRSM is highly challenging as it relies on the brushed connection. The brush/slipring-based connections need cooling, sealing and prone to wear and tear requiring regular maintenance. The proposed three-phase rotary transformer replaces the traditional brushed excitation by a high-power density polyphase wireless excitation. Furthermore, compared to a traditional single-phase rotary transformer, the proposed three-phase rotary transformer significantly enhances the power density, and reduces the eddy current losses and the output voltage ripples.

Aydin, Emrullah↗

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗