Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEED SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Oxidative instability of ionomers in hydroxide-exchange-membrane water electrolyzers

Hydroxide-exchange membrane (HEM) electrolyzers can produce green H 2 with only earth-abundant catalysts and electrolyte-free (nominally pure) water feed, significantly decreasing system cost and complexity. However, HEM technology suffers from short lifetimes, attributed in part to poor stability of anion-exchange polymers used in the membrane and catalyst layers. We use electrochemical analysis and ex situ characterization techniques to study anion-exchange-polymer degradation in electrolyzers. Using multiple ionomers, catalyst-layer additives, and electrolyte feed, we show how anode-ionomer oxidation is the dominant degradation mechanism for all HEM-based electrolyzer cells tested. Here, we find improved device stability using oxidation-resistant catalyst-layer binders and propose new design strategies for advanced ionomer and catalyst-layer development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Fouling, Low Cost Electrolytic Coagulation & Disinfection for Treating Flowback and Produced Water for Reuse

Executive Summary This Final Report is composed of two major sections. The first section presents experimental results obtained in the laboratory during Budget Period 1. The second section presents results from the field test conducted during Budget Period 2. Laboratory Results This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water from hydraulic fracturing and oil production operations. The treatment system improves the effectiveness and lowers the cost of coagulation processes using Fe3+ as the coagulant. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe3+ coagulating agent. The base is used to neutralize the treated water. Compared to conventional electrocoagulation (EC), the main advantage of the ECG system is an order of magnitude lower cost for the source of iron. The second advantage over conventional EC is that it can deliver Fe3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen in the water required to oxidize ferrous to ferric iron. The capital costs for conventional EC and the ECG system are similar, but the operational costs for the ECG system are an order of magnitude lower than conventional EC. The combined costs for iron and electrical energy for treating 1 m3 of FPW with 1 mM Fe3+ is estimated to be $0.87 for conventional EC, and $0.087 for the ECG system. The estimated all-in cost for treating FPW with a 2 mM Fe3+ dose is $0.73/m3 ($0.12/bbl). Field Test Results The field test was conducted at the Paul Foster Central Tank Battery (CTB) in Lea County, New Mexico from November 10, 2022 through December 15, 2022. The feed water to the system was produced water from the Tatanka 1H formation. After approximately two weeks of testing, the initial batch of produced water had been treated and no untreated produced water was available. Thus, after this time, the feed water to the system consisted of previously treated water (i.e., recycled water). The recycled water had nearly all colloidal particles removed, and had a much lower alkalinity due to precipitation of carbonate minerals during the first pass through the system. Although the recycled water was not an ideal test solution due to its low particulate concentrations, its lower alkalinity did allow us to identify the main problem with the treatment system. The main problem with the treatment system was caused by the high alkalinity of the initial feed water (5.4 meq/L) that consumed a significant fraction of the electrochemically generated acid. This resulted in pH values exiting the iron contact tank that were too high to dissolve enough iron to effectively treat the produced water. Tests performed with recycled water with lower alkalinity did not have this issue, and dissolved iron concentrations greater than 20 mM could be achieved. One consistent observation was that effluent water from the iron contact tank was always free of particulates, even when fed with circumneutral solutions. This suggests that there is no need to dissolve high concentrations of iron if all the water to be treated is passed through the scrap iron canister. In this case, dissolved O2 and hypochlorous acid can promote sufficient iron corrosion to provide an effective coagulating agent – even in neutral pH water. This solves the problem resulting from highly alkaline produced water. Modifications to the design of the treatment system were made based on the field test results. These modifications will add minimal additional cost, and were tested in bench-scale laboratory experiments. In short-term testing, the modified treatment process was able to remove colloidal FeS particulates to levels below detection. Long-term, steady state testing will be required to determine whether the modified process is suitable for commercial treatment systems.

54 ENVIRONMENTAL SCIENCES↗

Resolving Anodic Current and Temperature Distributions in a Polymer Electrolyte Membrane Water Electrolysis Cell Using a Pseudo-Two-Phase Computational Fluid Dynamics Model

Expanding upon our prior experimental work, we constructed a three-dimensional model of a polymer electrolyte membrane water electrolyzer using computational fluid dynamics. We applied the assumption of pseudo-two-phase flow, the flow of two phases with equal velocity. Experimental data were used to obtain parameters and to determine the conditions under which this model was valid. Anodic distributions of current density, temperature, liquid saturation, and relative humidity were obtained at various flow rates. The overall current density and temperature difference from inlet to outlet at the anode agreed strongly with experimental measurements under most circumstances. This verification allowed us to further examine the apparent gas coverage calculated from experimental and model temperature data. Results suggested a low liquid saturation and low relative humidity at the anode due to the consumption of liquid water and water vapor. However, we questioned the accuracy of the pseudo-two-phase assumption at low water feed rates. We concluded that the model was applicable to systems with liquid water feed rates greater than 0.6 ml min -1 cm -2 . Therefore, it is a fair screening method that can advise which operating conditions lead to excessive temperatures or drying at the anode, thereby promoting the longevity of the membrane and catalyst.

25 ENERGY STORAGE↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Plant science decadal vision 2020–2030: Reimagining the potential of plants for a healthy and sustainable future

Abstract Plants, and the biological systems around them, are key to the future health of the planet and its inhabitants. The Plant Science Decadal Vision 2020–2030 frames our ability to perform vital and far‐reaching research in plant systems sciences, essential to how we value participants and apply emerging technologies. We outline a comprehensive vision for addressing some of our most pressing global problems through discovery, practical applications, and education. The Decadal Vision was developed by the participants at the Plant Summit 2019, a community event organized by the Plant Science Research Network. The Decadal Vision describes a holistic vision for the next decade of plant science that blends recommendations for research, people, and technology. Going beyond discoveries and applications, we, the plant science community, must implement bold, innovative changes to research cultures and training paradigms in this era of automation, virtualization, and the looming shadow of climate change. Our vision and hopes for the next decade are encapsulated in the phrase reimagining the potential of plants for a healthy and sustainable future. The Decadal Vision recognizes the vital intersection of human and scientific elements and demands an integrated implementation of strategies for research (Goals 1–4), people (Goals 5 and 6), and technology (Goals 7 and 8). This report is intended to help inspire and guide the research community, scientific societies, federal funding agencies, private philanthropies, corporations, educators, entrepreneurs, and early career researchers over the next 10 years. The research encompass experimental and computational approaches to understanding and predicting ecosystem behavior; novel production systems for food, feed, and fiber with greater crop diversity, efficiency, productivity, and resilience that improve ecosystem health; approaches to realize the potential for advances in nutrition, discovery and engineering of plant‐based medicines, and "green infrastructure." Launching the Transparent Plant will use experimental and computational approaches to break down the phytobiome into a "parts store" that supports tinkering and supports query, prediction, and rapid‐response problem solving. Equity, diversity, and inclusion are indispensable cornerstones of realizing our vision. We make recommendations around funding and systems that support customized professional development. Plant systems are frequently taken for granted therefore we make recommendations to improve plant awareness and community science programs to increase understanding of scientific research. We prioritize emerging technologies, focusing on non‐invasive imaging, sensors, and plug‐and‐play portable lab technologies, coupled with enabling computational advances. Plant systems science will benefit from data management and future advances in automation, machine learning, natural language processing, and artificial intelligence‐assisted data integration, pattern identification, and decision making. Implementation of this vision will transform plant systems science and ripple outwards through society and across the globe. Beyond deepening our biological understanding, we envision entirely new applications. We further anticipate a wave of diversification of plant systems practitioners while stimulating community engagement, underpinning increasing entrepreneurship. This surge of engagement and knowledge will help satisfy and stoke people's natural curiosity about the future, and their desire to prepare for it, as they seek fuller information about food, health, climate and ecological systems.

59 BASIC BIOLOGICAL SCIENCES↗

Synthetic, Realistic Transmission and Distribution Co-Simulation for Voltage Control Benchmarking: Preprint

As distributed energy resources play an increasing role in generation and grid services, control and market paradigms will need to be tested with models that incorporate transmission and distribution systems. The test systems will need to be realistic and accessible for researchers to form conclusions about realistic behaviors and maintain comparability and repeatability of results. These test systems also must have high resolution models of sufficient size for realistic distribution and transmission interaction. This paper demonstrates the tightly coupled co-simulation of realistic synthetic distribution and transmission models for the Austin metropolitan area and how this framework can be used to analyze resultant behaviors from distributed resources and their controls. The comparison of a distribution system run with fixed feed-in voltage is compared to the closely tied distribution-transmission co-simulation. It is determined that even without advanced voltage controls, the feed-in voltage response of the transmission system shows a lower level of voltage excursions. Therefore, control methods for voltage stability should be benchmarked on realistic transmission and distribution co-simulations for more accurate assessment of voltage profiles.

27 ARPA - Advanced Research Projects Agency-Energy↗

Removal and recovery of ammonia from simulated wastewater using Ti3C2Tx MXene in flow electrode capacitive deionization

Abstract Flowing electrode capacitive deionization systems (FE-CDI) have recently garnered attention because of their ability to prevent cross contamination and operate in uninterrupted cycles ad infinitum. Typically, FE-CDI electrodes suffer from low conductivity, reducing deionization performance. Utilization of higher mass loadings to combat this leads to poor rheological properties. Herein, Ti 3 C 2 T x MXene was introduced as 1 mg mL −1 slurry electrodes in an FE-CDI system for the removal and recovery of ammonia from simulated agricultural wastewater. The electrode performance was evaluated by operating the FE-CDI system with a feed solution of 500 mg L −1 NH 4 Cl running in batch mode at a constant voltage of 1.20 and −1.20 V in charging and discharging modes, respectively. Despite the low loading, Ti 3 C 2 T x flowing electrodes showed markedly improved performance, achieving 60% ion removal efficiency in a saturation time of 115 min with an adsorption capacity of 460 mg g −1 . To understand the high adsorption performance of the electrodes, physiochemical and structural analysis was done via a variety of characterization techniques such as SEM, TEM, XRD, DLS, and Raman spectroscopy. Cyclic voltammetry and galvanostatic charge/discharge profiles were obtained to evaluate the electrochemical properties of the electrodes. The system proved to be an energy-saving technology by exhibiting a charge efficiency of 58–70% while operating at an energy consumption of 0.45 kWh kg −1 . A 92% regeneration efficiency showed that the electrodes were stable and suitable for long term and scalable usage. The results demonstrate that MXenes have the potential to improve the FE-CDI process for energy-efficient removal and recovery of ammonia.

36 MATERIALS SCIENCE↗

Substitution of virgin carbon fiber with low-cost recycled fiber in automotive grade injection molding polyamide 66 for equivalent composite mechanical performance with improved sustainability

Recycled carbon fiber has historically proven challenging to integrate into composite manufacturing due in no small part to the low-density, randomly oriented, discontinuous fiber format that results from typical recycling. Discontinuous fiber requires the use of alternative technologies than those traditionally applied to continuous fiber (e.g., hand lay-up, winding). Extrusion compounding is one such applicable technology, but material transfer into the system requires alternative feeding equipment or the use of an altered procedure as trialed in this research. In this study, an injection molding compound for automotive applications was prepared with recycled carbon fiber and compared against an existing commercial compound. Input fibers and molded compound were evaluated for mechanical performance, while relevant variables such as compounded fiber alignment and aspect ratio were compared to the existing baseline material to confirm a like-for-like composite material structure. Overall, analysis indicates that recycled fiber performs similarly to virgin fiber reinforcement, demonstrating that recycled fiber may be a viable drop-in replacement for short-fiber discontinuous applications.

42 ENGINEERING↗

Optimal design of multi-stage vacuum membrane distillation and integration with supercritical water desalination for improved zero liquid discharge desalination

Herein this paper proposes a novel concept for the optimal design of multi-stage vacuum membrane distillation (VMD). Generally, a multi-stage VMD is designed with an equal temperature difference between each stage. However, such a design is energy inefficient and increases VMD area. An analytical methodology for calculating the optimal stage temperature is proposed. By selecting the optimal stage temperature, the energy efficiency and required membrane area can be potentially improved by 16% and 30%, respectively. The proposed concept applies to all heat sources, including latent, sensible, and waste heat. To illustrate the method, multi-stage VMD is integrated with the waste heat from a supercritical water desalination (SCWD) system to achieve zero liquid discharge. SCWD is an energy-intensive process, requires high-quality thermal heat (>450 °C), and exhibits high waste heat rejection. The integrated VMD-SCWD approach is approximately 50% more energy-efficient and 35% more cost-efficient than the standalone SCWD system. Compared to the commercially used brine concentrator and crystallizer, the multi-stage VMD-SCWD system is more energy efficient for feed concentrations >5%. VMD-SCWD system is 30% cheaper, due to less expensive membrane distillation modules compared to a brine concentrator. The proposed design concept can replace the brine concentrator and crystallizer as an improved alternative for a zero-liquid discharge desalination system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed Load Shedding Application Architecture and Bi-Level Predictive Estimator Algorithm

Increasing penetrations of distributed renewables are decreasing the effectiveness of traditional decentralized under-frequency load shedding (UFLS) schemes. As more distribution circuits begin to back-feed the transmission system, operation of traditional UFLS may exacerbate frequency instability. This paper presents the conceptual framework for a data-rich environment to coordinate UFLS across multiple distribution providers based on the laminar coordination framework in order to ensure optimal adaptive setting of UFLS relays. Communication and control are enabled through a distributed implementation of the IEC 61968-1 Common Information Model message bus structure. In addition to the proposed architecture, a novel adaptive UFLS scheme informed by a bi-level state estimator to create optimal relay setpoints is introduced. Initial simulation results are presented for the IEEE 14-bus test system on scenarios leading to mis-operation of traditional UFLS.

Anderson, Alexander A.↗

Performance of a Natural Gas Solid Oxide Fuel Cell System With and Without Carbon Capture

The fuel cell program at the United States Department of Energy (DOE) National Energy Technology Laboratory (NETL) is focused on the development of low-cost, highly efficient, and reliable fossil-fuel-based solid oxide fuel cell (SOFC) power systems that can generate environmentally-friendly electric power with at least 90 percent carbon capture. NETL’s SOFC technology development roadmap is aligned with near-term market opportunities in the distributed generation sector to validate and advance the technology while paving the way for utility-scale natural gas (NG)- and coal-derived synthesis gas-fueled applications via progressively larger system demonstrations. The present study represents a part of a series of system evaluations being carried out at NETL to aid in prioritizing technological advances along research pathways to the realization of utility-scale SOFC systems, a transformational goal of the fuel cell program. In particular, the system performance of utility-scale NG fuel cell (NGFC) systems with and without carbon dioxide (CO2) capture is presented. The NGFC system analyzed features an external auto-thermal reformer (ATR) feeding the fuel to the SOFC system consisting of planar anode-supported SOFC with separated anode and cathode off-gas streams. In systems with CO2 capture, an air separation unit (ASU) is used to provide the oxygen for the ATR and for the combustion of unutilized fuel in the SOFC anode exhaust along with a CO2 purification unit to provide a nearly pure CO2 stream suitable for transport for usage in enhanced oil recovery operations or for storage in underground saline formations. Remaining thermal energy in the exhaust gases is recovered in a bottoming steam Rankine cycle while supplying any process heat requirements. A reduced order model (ROM) developed at the Pacific Northwest National Laboratory (PNNL) is used to predict the SOFC performance. The ROM, while being computationally effective for system studies, provides other detailed information about the state of the stack, such as the internal temperature gradient, generally not available from simple performance models often used to represent the SOFC. Such additional information can be important in system optimization studies to preclude operation under off-design conditions that can adversely impact overall system reliability. The NGFC system performance was analyzed by varying salient system parameters, including the percent of internal (to the SOFC module) NG reformation—ranging from 0 to 100 percent—fuel utilization, and current density. The impact of advances in underlying SOFC technology on electrical performance was also explored.

solid oxide fuel cell (SOFC), natural gas fuel cel↗

Influence of Supporting Electrolyte on Hydroxide Exchange Membrane Water Electrolysis Performance: Catholyte

Alkaline or hydroxide exchange membrane water electrolysis (HEMWE) is a promising technology for green hydrogen production using platinum group metal-free catalysts and stainless steel, an advantage of alkaline water electrolysis (AWE), and a gas-impermeable membrane, a parallel to proton exchange membrane electrolysis (PEMWE). However, the HEMWE requires supporting electrolytes and there is minimal understanding of their role on the respective reactions. Without SELs, HEMWE performance and durability are worse than PEMWE systems. Herein, consistently feeding potassium hydroxide anolyte, we systematically study the effects of catholyte SELs in HEMWEs including dry vs. wet operation, cation effects, anion effects, and cation/OH ratios on cell potential and stability. We report that (i) hydration of the cathode improves high current density operation by preventing dehydration of the hydroxide exchange membrane (HEM), (ii) there was no correlation between cation type and cell potential, (iii) cell potential and high frequency resistance did not correlate with SEL conductivity, (iv) cathodic carbonate SEL had a significant negative effect on cell performance, (v) increased cation/OH ratio also caused increased cell potentials. Overall, this study concludes that feeding water or potassium hydroxide solution is desirable to improve the AEMWE performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Play Fairway Analysis of the Snake River Plain, Idaho (Final Report)

The Snake River Plain (SRP) volcanic province overlies a thermal anomaly that extends deep into the mantle; it represents one of the highest heat flow provinces in North America. The Yellowstone hotspot continues to feed a magma system that underlies much of southern Idaho and has produced basaltic volcanism as young as 2000 years old. It has been estimated to host up to 855 MW of potential geothermal power production, most of which is associated with the Snake River Plain volcanic province in Idaho, which lies outside the area of Yellowstone National Park (Neely, K.W. and Galinato, G., 2007, Geothermal power generation in Idaho: an overview of current developments and future potential, Open File Report, Idaho Office of Energy Resources).

15 GEOTHERMAL ENERGY↗

Metal Hydride Compressor for High-Pressure (875 bar) Hydrogen Delivery

Metal hydride hydrogen compression utilizes a reversible heat-driven interaction of a hydride-forming metal alloy with hydrogen gas. This paper reports on the development of a laboratory scale two-stage Metal Hydride Compressor (MHC) system with a feed pressure of 150 bar delivering high purity H2 gas at outlet pressures up to 875 bar. Stage 1 and stage 2 AB 2 metal hydrides are identified based on experimental characterization of the pressure-composition-temperature (PCT) behavior of candidate materials. The selected metal hydrides are each combined with expanded natural graphite, increasing the thermal conductivity of the composites by an order of magnitude. These composites are integrated in two compressor beds with internal heat exchangers that alternate between hydrogenation and dehydrogenation cycles by thermally cycling between 20 °C and 150 °C. The prototype compressor achieved compression of hydrogen from 150 bar to 700 bar with an average flow rate of 33.6 g/hr.

08 HYDROGEN↗

Integrated Process Optimization for Biochemical Conversion

This research is motivated by the challenges faced during biomass processing in bioenergy plants. It has been observed that variations in biomass characteristics, such as moisture, ash, and carbohydrate contents cause variations in feeding of the system which led to underutilization of equipment and the reactor. The objective of this research is to ensure a continuous flow of biomass to the reactor in plants that use the biochemical conversion process to generate liquid fuels. The overall goal is to lower the cost of producing biofuels, which could lead to improving US’s energy independency and growing US’s rural economy. The research team developed analytical models, such as discrete element method (DEM) models and mathematical models. The DEM models are unit-level models that explicitly capture biomass characteristics and quantify the impacts of biomass characteristics on bulk material properties and the performance of specific equipment. The mathematical models are system-level models that capture the impacts of system infeed rate, equipment processing rate, storage location and capacity, and biomass characteristics on system throughput. The functional relations predicting the bulk material properties from DEM models are incorporated to the mathematical models. The models developed were validated and evaluated using data collected at Idaho National Laboratory’s biomass processing facility. Via these models, we identified process control strategies that ensure a continuous flow of biomass to the reactor, while meeting the requirements of biochemical conversion process. Our analysis indicates that sequencing of biomass bales based on moisture level, and carbohydrate contents could have a positive impact on reducing processing time and inventory level and increasing throughput rate. Short bale sequences that repeat frequently, seem to have the greatest impact on improving system’s performance. Based on our experiments, the total annual system operating costs reduced by 20-30%, and the maximum inventory level reduced by 3 to 4 times. The operating costs include the annual equipment amortization cost and processing cost. The implementation of the models developed requires the use of standardized bale format, Radio Frequency Identification technology, sensing and real time monitoring of material attributes, automated material handling equipment, and automated process control. The scope of the model proposed can be extended to include the whole supply chain. The supply chain models help identify how many bales of different biomass feedstock to purchase given biomass availability in the region, biomass price and quality, and the biomass processing capabilities of the biorefinery. Thus, the outcomes of supply chain models can be used to inform the design of long-term contracts among farmers and the biorefinery.

09 BIOMASS FUELS↗

Transmitter with fully re-assignable segments for reconfigurable FFE taps

Methods and systems of performing feed forward equalization (FFE) on data streams are described. A circuitry may generate staggered data streams from data streams of an input signal. The staggered data streams may include data in staggered unit intervals. The circuitry may include a plurality of segments. A segment may define a specific unit interval to carve the staggered data streams into one unit interval pulses positioned at the specific unit interval. The specific unit interval to carve the staggered data streams may indicate an assignment of the segment as one of a FFE pre tap, a FFE main tap, and a FFE post tap. The plurality of segments may be assigned to different FFE taps based on different clock signal selection defining different unit intervals to perform the carving. The plurality of segments may output respective one unit interval pulses to reproduce the input signal.

Toprak-Deniz, Zeynep↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase I Conceptual Study)

The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and the proposed system is an improvement over alternate low carbon dispatchable power options. Our demonstration will include 54 MWh of hydrogen storage. CO 2 capture inherent to the CHG process can capture 90% of the CO 2 (with upgrades to >98%) in a commercial system (~300 MWth) for sequestration or other uses. The hydrogen will be utilized in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with the existing Southern Company fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load. However, H 2 production is relatively constant by storing H 2 , and revenues are improved by arbitrage between use of low-cost off-peak variable electricity generation or use of stored H 2 under peak demand. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via system requirements review with the whole team. These requirements were then incorporated into/iterated with our Heat & Mass Balance models and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Our system generates power at 17.4% lower cost than other low carbon approaches for the H 2 generation, H 2 compression and storage, carbon sequestration, and HRSG added electricity production for a large-scale duct-fired system. Our team recommends completing the Phase II Pre-FEED study for the proposed system as the next step for the project and its tasks will achieve the overall objective and be ready to launch the FEED. The Pre-FEED tasks include updating the requirements, Concept of Operations, plant scope/process description, component modeling, system modeling, performance estimates, emission estimates, block flow diagrams, fluid/process conditions (PFD), utility usage, and facility sizing/definition. The approach will be to complete these updates in a greater level of detail for the selected site. The approach for developing the EIV is to use the updated results, including model outputs, for carbon dioxide and waste streams.

03 NATURAL GAS↗

FY 23 Filtration of Hanford Tank 241-SY-101 Supernatant at 16 °C

Approximately 9 liters of supernatant from Hanford waste tank 241-SY-101 was delivered by Washington River Protection Solutions to the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory. The thirty-six SY-101 sample bottles were comprised of six sets of six samples, with each set pulled from a unique tank sampling level. Prior to testing, samples from each level were composited to provide nominally level-independent feed for dead end filtration and ion exchange testing. The composited 241-SY-101 supernatant was chilled to 16 °C for 1 week prior to testing. Filtration testing was then conducted using a backpulse dead-end filter (BDEF) system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the RPL. This was done to provide waste processing benchmarks for 200 West Area wastes in the West Area Risk Management project. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 . During filtration of the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased little over the filtration campaign and never reached 2 psid (the Tank Side Cesium Removal system action limit). This indicates that the Media Grade 5 filter should perform well when processing SY-101 supernatant. After completing filtration of the SY-101 feed, the filter was cleaned. Solids concentrated from the backpulse solutions displayed calcium phosphate, aluminum oxides, aluminum-chromium nanoparticle agglomerates. Electron diffraction was used to determine the types of phases that were present in the solids. Most of the phases found were only weakly crystalline, possibly owing to their rapid precipitation during the process water treatment. The identifications of the phases therefore are tentative.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗