Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FAILURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Metabolic Response on Post-therapy FDG-PET Predicts Patterns of Failure After Radiotherapy for Cervical Cancer

Purpose: To determine the patterns of failure in patients with cervical cancer treated with definitive radiotherapy and evaluated for metabolic response with early posttherapy {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET). Methods and Materials: The records of 238 patients with cervical cancer were reviewed. All patients were treated with a combination of external radiotherapy and intracavitary brachytherapy. Two hundred and nineteen patients (92%) received concurrent chemotherapy. All patients underwent pretreatment FDG-PET, and posttherapy FDG-PET was performed within 8-16 weeks of the completion of radiotherapy. Posttherapy FDG-PET results were categorized as complete metabolic response (CMR), partial metabolic response (PMR), and progressive disease (PD). Failure patterns were categorized as none, isolated local failure (central pelvis {+-} pelvic lymph nodes), distant failure, or combined local plus distant failure. Results: Of the 91 patients (38%) who had a recurrence, 22 had isolated local failures, and 69 had distant failures (49 distant failures and 20 combined local plus distant failures). Of the 173 patients with a CMR, 40 (23%) experienced treatment failure. All 25 patients with PD experienced treatment failure, which was distant in 24 patients (96%). Among the 40 patients with PMR, no failure has been observed for 14 patients (35%). Of the 26 failures within the PMR group, 15 (58%) were limited to the pelvis. Differences in the patterns of failure between the three groups (CMR, PMR, PD) were statistically significant (chi-square test; p < 0.0001). Conclusions: The majority of failures after definitive radiotherapy for cervical cancer include distant failures, even in the setting of concurrent chemotherapy. PMR within the cervix or lymph nodes is more commonly associated with isolated local recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rethinking PCMI Failures Under Transient Conditions

Under PCMI conditions, the cladding strain is driven by either pellet swelling during normal operation or pellet thermal expansion in transients. The loading in PCMI is displacement controlled because friction between the pellet and the cladding results in a strain compatibility at the pellet/cladding interface. Failure is known to occur under PCMI loading conditions during operation when normal power changes result in release of iodine (and other fission products) causing stress corrosion cracking where the crack-propagation rate is dependent upon the cladding stress but slow relative to strictly mechanical failures. Failures after normal power changes are often referred to as failure by pellet-cladding interaction or PCI to distinguish it from PCMI. Such failures are considered displacement-controlled failures, as noted above, and occur with limited plastic strain. This is different to what is typically thought of as PCMI failure under transient conditions, either Anticipated Operational Occurrences (AOOs) or Reactivity Insertion Accidents (RIAs), which is generally assumed to occur once the cladding reaches a mechanical strain limit. But there are two features in the typical PCMI failure in an RIA that are not consistent with the PCMI assumptions. The first is the ductile shear failure feature in cross section and the second is a large crack opening post failure (e.g., see OI-11 failure in NSRR program). The ductile feature is indicative of a plastic instability that requires very large local strains, and the large crack opening must be the result of a release of energy, both of which are not expected if stress in the cladding was only driven by thermal expansion in the pellet. It is concluded that there must be a mechanism (likely related to rod internal pressure) that eliminates strain compatibility between the pellet and cladding – allowing strain localization to occur in what are known as PCMI transient failures. In some sense, these PCMI failures may actually be early burst failures that occur when thermal expansion causes uniform strains greater than a defined limit and fission gas pressure eliminate the strain compatibility

Cantonwine, Paul↗

An Investigation of Digital Instrumentation and Control System Failure Modes

A study sponsored by the Nuclear Regulatory Commission study was conducted to investigate digital instrumentation and control (DI&C) systems and module-level failure modes using a number of databases both in the nuclear and non-nuclear industries. The objectives of the study were to obtain relevant operational experience data to identify generic DI&C system failure modes and failure mechanisms, and to obtain generic insights, with the intent of using results to establish a unified framework for categorizing failure modes and mechanisms. Of the seven databases studied, the Equipment Performance Information Exchange database was found to contain the most useful data relevant to the study. Even so, the general lack of quality relative to the objectives of the study did not allow the development of a unified framework for failure modes and mechanisms of nuclear I&C systems. However, an attempt was made to characterize all the failure modes observed (i.e., without regard to the type of I&C equipment under consideration) into common categories. It was found that all the failure modes identified could be characterized as (a) detectable/preventable before failures, (b) age-related failures, (c) random failures, (d) random/sudden failures, or (e) intermittent failures. The percentage of failure modes characterized as (a) was significant, implying that a significant reduction in system failures could be achieved through improved online monitoring, exhaustive testing prior to installation, adequate configuration control or verification and validation, etc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity analysis applied to SiC failure probability in TRISO modeled with BISON

Here, a sensitivity analysis on the failure probability of the Silicon Carbide (SiC) layer in tristructural isotropic (TRISO) nuclear fuel during transient conditions predicted by the BISON fuel performance code is performed. The principal goal of the analysis is to understand the most important parameters dictating SiC failure behavior in BISON during Reactivity Initiated Accidents (RIAs). SiC brittle fracture probability is modeled using Weibull statistics. A total of seven inputs related to SiC failure has been selected for the analysis, including the Weibull statistics parameters, elastic moduli for SiC and Pyrolitic Carbon (PyC) and SiC stress-free temperature. A 1D TRISO BISON model has been established for various reactivity insertions performed at the Nuclear Safety Research Reactor (NSRR). The principal advantage associated with the 1D TRISO model developed in this work is its computational efficiency. The Sobol variance decomposition method is used, and the sensitivity indices are presented for eight different values of the energy deposition. The results show that the two most important parameters impacting the predicted SiC failure probability are the Weibull modulus and the characteristic stress, and a co-variance amongst these parameters is obtained for low reactivity insertions. An additional new finding of this work is that the relative importance of Weibull parameters depends on the energy deposition, and thus reactivity, regime. For low energy depositions, two parameters are of influence on SiC failure probability, while for high energy depositions only one parameter impacts failure probability results. Moreover, optimization of the Weibull modulus and characteristic stress is performed by minimizing the RMSE between BISON failure probability predictions and experimental failure fractions for each energy deposition. This work also demonstrates the validity of the NSRR tests BISON simulations and of the respective sensitivity analysis results as conservative, yet indicative for slower transients characterized by lower deposited energies. Such verification is achieved through the partial extension of the analysis to a group Control Rod Withdrawal reproduced from a previous study. Another novel result of this analysis is that no single set of Weibull parameters can reproduce all reactivity insertion experimental failure results, which is related to the intrinsic nature of SiC failure properties, and a new range for the parameters is proposed to produce a failure probability envelope that encompasses the experimental fractions. Additionaly, this work proposes a new approach for future failure analysis with BISON, consisting in the use of Weibull parameters ranges, rather than fixed sets, along with failure envelopes generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prospective Assessment of Patterns of Failure After High-Precision Definitive (Chemo)Radiation in Head-and-Neck Squamous Cell Carcinoma

Purpose: To prospectively analyze patterns of failure in patients with head-and-neck squamous cell carcinoma treated with definitive high-precision radiotherapy with a focus on location of failure relative to target volume coverage. Methods and Materials: Sixty patients treated with three-dimensional conformal radiotherapy or intensity-modulated radiation therapy were included. Locoregional failure volume was defined on the planning data set at relapse, and dose received was analyzed by use of dose-volume histograms. Results: Thirteen patients were deemed to have had locoregional failures, of which two did not have any viable tumor on salvage neck dissection, leaving eleven patients with proven persistent or recurrent locoregional disease. Of these, 9 patients had in-field failure, 1 marginal failure, and 1 both in-field and marginal failures. Overall, only 2 of 11 patients (18%) with relapse had any marginal failure. Of the 20 sites of locoregional failure, 15 (75%) were in-field and 5 (25%) marginal. Distant metastases were detected in 3 patients, whereas a second new primary developed in 3 others. With a median follow-up of 26 months (interquartile range, 18-31 months) for surviving patients, the 3-year local control, locoregional control, disease-free survival, and overall survival rates were 75.3%, 74%, 67.2%, and 60.5%, respectively. Conclusions: Locoregional relapse remains the predominant pattern of failure in head-and-neck squamous cell carcinoma treated with high-precision definitive radiotherapy with the majority of failures occurring 'in-field' within the high-dose volume. Marginal failures can occur, particularly in the vicinity of the spared parotid gland. The therapeutic index of high-precision conformal radiotherapy is largely dependent on adequate selection and delineation of target volumes and organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure criteria of unidirectional carbon fiber reinforced polymer composites informed by a computational micromechanics model

Failure prediction for carbon fiber reinforced polymer (CFRP) composites has been a longstanding challenge. In this paper, we address this challenge by first applying a well-established computational micromechanics model based on representative volume element to predict the failure envelopes of unidirectional (UD) CFRP composites. Then, these failure envelopes are compared with the classical failure criteria. We have evaluated the performances of these failure criteria and identified the aspects for further improvement in their accuracies for the UD CFRP composites studied herein. Based on the failure mechanisms from computational analyses and the comparisons between predicted failure envelopes and classical failure criteria, a new set of homogenized failure criteria is proposed. Additionally, the newly proposed failure criteria show significant improvement according to our computational and experimental results. Furthermore, we have compared the proposed failure criteria with existing experimental data and computational results available in the literature for different types of composites. Good agreements are generally observed.

36 MATERIALS SCIENCE↗

Patterns of Failure After Proton Therapy in Medulloblastoma; Linear Energy Transfer Distributions and Relative Biological Effectiveness Associations for Relapses

Purpose: The pattern of failure in medulloblastoma patients treated with proton radiation therapy is unknown. For this increasingly used modality, it is important to ensure that outcomes are comparable to those in modern photon series. It has been suggested this pattern may differ from photons because of variations in linear energy transfer (LET) and relative biological effectiveness (RBE). In addition, the use of matching fields for delivery of craniospinal irradiation (CSI) may influence patterns of relapse. Here we report the patterns of failure after the use of protons, compare it to that in the available photon literature, and determine the LET and RBE values in areas of recurrence. Methods and Materials: Retrospective review of patients with medulloblastoma treated with proton radiation therapy at Massachusetts General Hospital (MGH) between 2002 and 2011. We documented the locations of first relapse. Discrete failures were contoured on the original planning computed tomography scan. Monte Carlo calculation methods were used to estimate the proton LET distribution. Models were used to estimate RBE values based on the LET distributions. Results: A total of 109 patients were followed for a median of 38.8 months (range, 1.4-119.2 months). Of the patients, 16 experienced relapse. Relapse involved the supratentorial compartment (n=8), spinal compartment (n=11), and posterior fossa (n=5). Eleven failures were isolated to a single compartment; 6 failures in the spine, 4 failures in the supratentorium, and 1 failure in the posterior fossa. The remaining patients had multiple sites of disease. One isolated spinal failure occurred at the spinal junction of 2 fields. None of the 70 patients treated with an involved-field-only boost failed in the posterior fossa outside of the tumor bed. We found no correlation between Monte Carlo-calculated LET distribution and regions of recurrence. Conclusions: The most common site of failure in patients treated with protons for medulloblastoma was outside of the posterior fossa. The most common site for isolated local failure was the spine. We recommend consideration of spinal imaging in follow-up and careful attention to dose distribution in the spinal junction regions. Development of techniques that do not require field matching may be of benefit. We did not identify a direct correlation between lower LET values and recurrence in medulloblastoma patients treated with proton therapy. Patterns of failure do not appear to differ from those in patients treated with photon therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review and categorization of existing studies on the estimation of probabilistic failure metrics for Reactor Coolant Pressure Boundary piping and steam generator tubes in Nuclear Power Plants

This article presents the first output of the International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP), titled Methodology for Assessing Pipe Failure Rates in Advanced Water-Cooled Reactors (AWCRs), launched in 2018. This IAEA CRP is aimed at developing a good-practices document for estimating the probabilistic failure metrics of piping in AWCRs. The reliability of piping that comprise the Reactor Coolant Pressure Boundary (RCPB) is important for maintaining safe and stable operations of Nuclear Power Plants (NPPs) because failure of those piping components could lead to undesirable consequences, such as plant shutdown, costly repair, the occurrence of Loss-of-Coolant Accidents (LOCAs) and, possibly, subsequent core damage or large release events. Probabilistic failure metrics (e.g., failure rate, failure frequency, or failure probability) of RCPB components are the key inputs to the Probabilistic Safety/Risk Assessment (PSA/PRA) and risk management of NPPs. The estimation of probabilistic failure metrics, however, is challenging, especially for AWCRs, due to the lack of operating experience. Therefore, as the first step of the IAEA CRP activities, this paper is developed to provide a literature review of the existing studies (from 2000 to April 2019) on the estimation of probabilistic failure metrics for RCPB piping and Steam Generator (SG) tubes of NPPs and to categorize them based on four criteria: (1) explicitness of incorporation of physical failure mechanisms; (2) types of failure characterization; (3) types of physical models for degradation; and (4) explicitness of consideration of maintenance. The existing studies are also analyzed from the viewpoint of the following key aspects: (i) uncertainty analysis, (ii) sensitivity analysis, (iii) validation strategies, and (iv) the areas of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analyzing a Five-Year Failure Record of a Leadership-Class Supercomputer

Extreme-scale computing systems are required to solve some of the grand challenges in science and technology. From astrophysics to molecular biology, supercomputers are an essential tool to accelerate scientific discovery. However, large computing systems are prone to failures due to their complexity. It is crucial to develop an understanding of how these systems fail to design reliable supercomputing platforms for the future. This paper examines a five-year failure and workload record of a leadership-class supercomputer. To the best of our knowledge, five years represents the vast majority of the lifespan of a supercomputer. This is the first time such analysis is performed on a top 10 modern supercomputer. We performed a failure categorization and found out that: i) most errors are GPU-related, with roughly 37% of them being double-bit errors on the cards; ii) failures are not evenly spread across the physical machine, with room temperature presumably playing a major role; and iii) software errors of the system bring down several nodes concurrently. Our failure rate analysis unveils that: i) the system consistently degrades, being at least twice as reliable at the beginning, compared to the end of the period; ii) Weibull distribution closely fits the mean-time-between-failure data; and iii) hardware and software errors show a markedly different pattern. Finally, we correlated failure and workload records to reveal that: i) failure and workload records are weakly correlated, except for certain types of failures when segmented by the hours of the day; ii) several categories of failures make jobs crash within the first minutes of execution; and iii) a significant fraction of failed jobs exhaust the requested time with a disregard of when the failure occurred during execution.

Rojas, Elvis↗

SU-E-T-495: Neutron Induced Electronics Failure Rate Analysis for a Single Room Proton Accelerator

Purpose: To determine the failure rate as a function of neutron dose of the range modulator's servo motor controller system (SMCS) while shielded with Borated Polyethylene (BPE) and unshielded in a single room proton accelerator. Methods: Two experimental setups were constructed using two servo motor controllers and two motors. Each SMCS was then placed 30 cm from the end of the plugged proton accelerator applicator. The motor was then turned on and observed from outside of the vault while being irradiated to known neutron doses determined from bubble detector measurements. Anytime the motor deviated from the programmed motion a failure was recorded along with the delivered dose. The experiment was repeated using 9 cm of BPE shielding surrounding the SMCS. Results: Ten SMCS failures were recorded in each experiment. The dose per monitor unit for the unshielded SMCS was 0.0211 mSv/MU and 0.0144 mSv/MU for the shielded SMCS. The mean dose to produce a failure for the unshielded SMCS was 63.5 ± 58.3 mSv versus 17.0 ±12.2 mSv for the shielded. The mean number of MUs between failures were 2297 ± 1891 MU for the unshielded SMCS and 2122 ± 1523 MU for the shielded. A Wilcoxon Signed Ranked test showed the dose between failures were significantly different (P value = 0.044) while the number of MUs between failures were not (P value = 1.000). Statistical analysis determined a SMCS neutron dose of 5.3 mSv produces a 5% chance of failure. Depending on the workload and location of the SMCS, this failure rate could impede clinical workflow. Conclusion: BPE shielding was shown to not reduce the average failure of the SMCS and relocation of the system outside of the accelerator vault was required to lower the failure rate enough to avoid impeding clinical work flow.

07 ISOTOPE AND RADIATION SOURCES↗

Graded approach for assessing digital system failure susceptibilities - 305

Owner/operators of nuclear plants must be able to identify and assess susceptibilities to digital system failures and unintended behaviors that could lead to plant system malfunctions, including common-cause failures (CCFs) of multiple controlled components that may impact overall plant safety. Nuclear plant designers and regulators often assess and manage potential failure modes by assuming the failure occurs and showing by analysis that the results are acceptable. In 2016 EPRI published a guideline on Methods for Assuring Safety and Dependability when Applying Digital Instrumentation and Control Systems (EPRI 3002005326), which takes a more holistic approach that considers digital system failure modes from the perspective of their impact on plant risk and includes a graded approach based on safety significance. This paper describes that graded approach. The methodology in EPRI 3002005326 systematically identifies potential I and C vulnerabilities that could lead to significant malfunctions of controlled components and systems, including common-cause failures (CCF), and discusses in detail methods to protect against them. It considers both preventive measures that reduce the likelihood of failures, and plant systems and features that mitigate the effects of component failures and misbehaviors. Coping analysis is then performed as appropriate to provide additional assurance of protection. The safety significance based graded approach is an important feature in that it can help users focus attention on overall plant safety, including potentially risk-significant scenarios that might not be considered in traditional safety analyses. The purpose is to help the user ensure that modifications to the I and C that could potentially be safety significant are treated appropriately and at the same time not waste valuable resources on excessive protection against changes that have little or no impact on safety. The graded approach allows the design engineer to tailor the rigor of the preventive, limiting, and mitigative measures commensurately with the effects the I and C modification has on overall plant safety. The graded approach focuses on safety significance impact, which is effectively a qualitative measure of the potential change in safety (or risk) caused by a proposed I and C modification, as compared to the I and C that is being replaced. Safety significance impact should not be confused with importance to safety or risk significance. It is possible that an upgrade to safety-related and/or risk-significant I and C systems may have little or no safety significant impact and vice versa. The approach considers three factors that influence the impact on safety significance of a proposed I and C modification: context, likelihood of failure, and consequences of failure. The most significant of the three factors is context - what the I and C is connected to, both directly and indirectly, including its potential effects on plant systems that respond to transients or accidents. The graded approach is particularly helpful in assessing potential CCFs resulting from digital I and C failures, and shows why the most problematic CCFs will be those that can affect multiple plant systems. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surrogate Models for Estimating Failure in Brittle and Quasi-Brittle Materials

In brittle fracture applications, failure paths, regions where the failure occurs and damage statistics, are some of the key quantities of interest (QoI). High-fidelity models for brittle failure that accurately predict these QoI exist but are highly computationally intensive, making them infeasible to incorporate in upscaling and uncertainty quantification frameworks. The goal of this paper is to provide a fast heuristic to reasonably estimate quantities such as failure path and damage in the process of brittle failure. Towards this goal, we first present a method to predict failure paths under tensile loading conditions and low-strain rates. The method uses a k-nearest neighbors algorithm built on fracture process zone theory, and identifies the set of all possible pre-existing cracks that are likely to join early to form a large crack. The method then identifies zone of failure and failure paths using weighted graphs algorithms. We compare these failure paths to those computed with a high-fidelity fracture mechanics model called the Hybrid Optimization Software Simulation Suite (HOSS). A probabilistic evolution model for average damage in a system is also developed that is trained using 150 HOSS simulations and tested on 40 simulations. A non-parametric approach based on confidence intervals is used to determine the damage evolution over time along the dominant failure path. For upscaling, damage is the key QoI needed as an input by the continuum models. This needs to be informed accurately by the surrogate models for calculating effective moduli at continuum-scale. We show that for the proposed average damage evolution model, the prediction accuracy on the test data is more than 90%. In terms of the computational time, the proposed models are ≈ O ( 10 6 ) times faster compared to high-fidelity fracture simulations by HOSS. These aspects make the proposed surrogate model attractive for upscaling damage from micro-scale models to continuum models. We would like to emphasize that the surrogate models are not a replacement of physical understanding of fracture propagation. The proposed method in this paper is limited to tensile loading conditions at low-strain rates. This loading condition corresponds to a dominant fracture perpendicular to tensile direction. The proposed method is not applicable for in-plane shear, out-of-plane shear, and higher strain rate loading conditions.

36 MATERIALS SCIENCE↗

Assessment of Cladding-Cladding Delamination Failures in U-Mo Fuel Plates

Monolithic fuel is a candidate fuel form for the conversion of high-performance research reactors. This plate-type fuel consists of a high-density, U-Mo alloy-based fuel in a monolithic form that is sandwiched between zirconium diffusion barriers and encapsulated in an aluminum cladding. To qualify this fuel system, the program must demonstrate that the fuel meets the safety standards, has a predictable behavior, and performs well in a reactor. Although many plates have shown satisfactory thermo-mechanical performance in reactor, a small number of experimental plates exhibited failures, rendering performance of these plates unacceptable. Post-irradiation examinations of failed plates have revealed that various failures modes are present, including pillowing, blistering, buckling, warping, delamination, fracture, rupture, oxide spallation, etc. Previous studies have implied that such various operational and loading conditions could generate a complex stress-strain state, facilitating distinct failure modes that could impact the structural integrity. To understand such various failure modes, a comprehensive set of studies focusing on failure modes is being performed. As a part of these studies, this work studies the cladding-cladding separation failures that were observed in some of previous irradiation tests. To understand the root cause of cladding separation failures, selected plates from previous irradiation experiments were simulated under comparable operational conditions. Stress-strain state of the plates at the interface were examined. The results were comparatively evaluated to understand possible effects of stress state of the bond-line on delamination failures. This paper presents these findings, discusses such failure modes, and examines the influence of various factors on previously observed cladding delamination failures.

42 ENGINEERING↗

Correlation Between Weather Alerts and Grid Component Failures for Grid Alert

Weather events cause most grid failures. Often, we even get notifications on our phones to take cover or be prepared for an imminent event. If electric grid utilities had a similar warning that also included probable scenarios and the equipment involved, they could prepare and minimize the effects. Recent research at Idaho National Laboratory into electric grid risk analysis methods resulted in a tool that allows for the development of the most likely scenarios given failure probabilities of grid components. INL has a project with the U.S. Department of Energy’s Cybersecurity, Energy Security, and Emergency Response (CESER) program to develop a Grid Alert application that receives messages from the existing emergency alert system, filters and determines components possibly affected by the emergency event, calculates probable scenarios uses MASTERRI and then notifies the utility if there is significant risk. Historical failure data of elements that comprise the U.S. electric grid have been compiled by utilities and organizations such as the international regulatory body North American Electric Reliability Corporation (NERC). Nominal failure rates are obtained from this data. To make this tool possible, estimated failure rates are needed for different component types given the alert type, severity, and location. Historic weather-related grid element failures are correlated with historic weather events from Integrated Public Alert & Warning System (IPAWS). These correlated events and failures are used along with Bayesian updates from the historical norms to provide a modified failure rate for grid elements in the alert areas and calculate probable scenarios. This discusses the Grid Alert project plan but focuses on the data gathered and process used in determining failure rates for possible grid failure scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Failure propagation in multi-cell lithium ion batteries

Traditionally, safety and impact of failure concerns of lithium ion batteries have dealt with the field failure of single cells. However, large and complex battery systems require the consideration of how a single cell failure will impact the system as a whole. Initial failure that leads to the thermal runaway of other cells within the system creates a much more serious condition than the failure of a single cell. This work examines the behavior of small modules of cylindrical and stacked pouch cells after thermal runaway is induced in a single cell through nail penetration trigger [1] within the module. Cylindrical cells are observed to be less prone to propagate, if failure propagates at all, owing to the limited contact between neighboring cells. However, the electrical connectivity is found to be impactful as the 10S1P cylindrical cell module did not show failure propagation through the module, while the 1S10P module had an energetic thermal runaway consuming the module minutes after the initiation failure trigger. Modules built using pouch cells conversely showed the impact of strong heat transfer between cells. In this case, a large surface area of the cells was in direct contact with its neighbors, allowing failure to propagate through the entire battery within 60-80 seconds for all configurations (parallel or series) tested. This work demonstrates the increased severity possible when a point failure impacts the surrounding battery system.

25 ENERGY STORAGE↗

Prognostic model and failure mechanisms of steam generators in Sodium-Cooled fast reactors

This paper presents a prognostic model for sodium-cooled fast reactor (SFR) steam generators (SGs). Here, the purpose of the model is to estimate the remaining useful life of SFR SGs and thus to support the decision-making of autonomous control. SFR SGs are of great interest for plant integrity due to their harsh operation environment. They operate at higher temperatures and higher coolant-to-steam pressure differences than those of current light water reactors (LWR). The severity of the SFR SG failure consequences, which include water-sodium contact, is another reason. Understanding its failure mechanisms is important for the development of its prognostic model. Based on our literature review and physics-based analysis, we concluded that creep would be a dominant degradation mode of SFR SGs due to SFR’s high-temperature and high-pressure environment. Thus, creep is the focus of the prognostic model. Various other failure modes were also investigated in this study. The mechanical fatigue due to flow-induced vibration is usually observed in early developmental phases and would not be an important issue during normal operation. The thermal fatigue due to thermal stripping is occasionally observed in other components in SFRs but does not affect SG integrity. Pure water stress corrosive crack, fretting, and so on are commonly observed in LWR SGs but are significantly less important in SFR SGs because of the high temperatures, high pressure differences, and chemical properties of liquid sodium. Based on these investigations, a prognostic model focusing on creep failures was developed. It estimates the failure probability profile by sampling the Larson-Miller parameter (LMP) and temperature and associated uncertainties through Monte Carlo methods. Two case studies were presented. The first one demonstrated the model’s capability to calculate the failure probability for a new specimen within a given time. If the tube is working under temperatures of 500C ± 3 and pressures of 15.2 MPa, which leads to LMP of 20,100 ± 50, the failure probabilities within 50, 70, and 90 years are approximately 0.1 %, 3.2 %, and 17.5 %. The second demonstrated how adjusting the workload can help to protect the integrity of the component. For an old tube reaching 99 % of its lifespan, continuing to run at temperatures of 500C ± 3 and LMP of 20,100 ± 50 leads to a failure probability of about 29.0 % within a year. If the temperature is reduced by 5C, the failure probability can be reduced to 2.5 %, and, if the pressure is also reduced such that the LMP is increased by 100, the failure probability can further be reduced to 0.12 %.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Understanding and Exploiting Spatial Properties of System Failures on Extreme-Scale HPC Systems, In: 2015 45th Annual IEEE/IFIP International Conference on Dependable Systems and Networks

As we approach exascale, the scientific simulations are expected to experience more interruptions due to increased system failures. Designing better HPC resilience techniques requires understanding the key characteristics of system failures on these systems. While temporal properties of system failures on HPC systems have been well-investigated, there is limited understanding about the spatial characteristics of system failures and its impact on the resilience mechanisms. Therefore, we examine the spatial characteristics and behavior of system failures. We investigate the interaction between spatial and temporal characteristics of failures and its implications for system operations and resilience mechanisms on large-scale HPC systems. We show that system failures have "spatial locality" at different granularity in the system, study impact of different failure-types, and investigate the correlation among different failure-types. Finally, we propose a novel scheme that exploits the spatial locality in failures to improve application and system performance. Our evaluation shows that the proposed scheme significantly improves the system performance in a dynamic and production-level HPC system.

Computer Science↗

SU-F-T-247: Collision Risks in a Modern Radiation Oncology Department: An Efficient Approach to Failure Modes and Effects Analysis

Purpose: Collisions between treatment equipment and patients are potentially catastrophic. Modern technology now commonly involves automated remote motion during imaging and treatment, yet a systematic assessment to identify and mitigate collision risks has yet to be performed. Failure modes and effects analysis (FMEA) is a method of risk assessment that has been increasingly used in healthcare, yet can be resource intensive. This work presents an efficient approach to FMEA to identify collision risks and implement practical interventions within a modern radiation therapy department. Methods: Potential collisions (e.g. failure modes) were assessed for all treatment and simulation rooms by teams consisting of physicists, therapists, and radiation oncologists. Failure modes were grouped into classes according to similar characteristics. A single group meeting was held to identify implementable interventions for the highest priority classes of failure modes. Results: A total of 60 unique failure modes were identified by 6 different teams of physicists, therapists, and radiation oncologists. Failure modes were grouped into four main classes: specific patient setups, automated equipment motion, manual equipment motion, and actions in QA or service mode. Two of these classes, unusual patient setups and automated machine motion, were identified as being high priority in terms severity of consequence and addressability by interventions. The two highest risk classes consisted of 33 failure modes (55% of the total). In a single one hour group meeting, 6 interventions were identified. Those interventions addressed 100% of the high risk classes of failure modes (55% of all failure modes identified). Conclusion: A class-based approach to FMEA was developed to efficiently identify collision risks and implement interventions in a modern radiation oncology department. Failure modes and interventions will be listed, and a comparison of this approach against traditional FMEA methods will be presented.

60 APPLIED LIFE SCIENCES↗