Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exact two component”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

75 records · Page 5

Transporting Non-Compliant TRU Wastes in the OPTIMUS{sup TM} Packages - 20493

The OPTIMUS{sup TM} product line of packages was developed with the purpose of providing a versatile and modular packaging option for shipping problematic wastes and fissile material contents. The product line includes a high-activity design in the OPTIMUS-H and a low activity design in the OPTIMUS-L. The two variants utilize a singular containment vessel design, that is enclosed in different protective components that offer different levels of shielding along with thermal and impact protection. The thick shielding provided by the OPTIMUS-H packaging allows for higher activity contents than the OPTIMUS-L to be transported. But the lightweight design of the OPTIMUS-L packaging allows for more packages to be transported in a single shipment. The containment vessel design shared between the two packages provides leak-tight containment of all radioactive contents along with the capabilities to easily leak test and the option to inert and backfill the contents, as necessary, prior to each shipment of the package. Together the OPTIMUS package designs offer significant flexibility and are capable of handling a wide variety of waste materials and other radioactive contents. One of the primary contents covered in the initial design effort for these packages is TRU waste contents beyond the standard waste materials that are compliant with the WIPP Waste Acceptance Criteria. More specifically, the initial content of interest is TRU Waste drums containing sealed containers with potentially flammable gases. While there are multiple other packaging options available for transporting standard WIPP compliant TRU wastes, the goal of the OPTIMUS packages is to offer a superior option for transporting both standard TRU wastes as well as the more problematic non-compliant wastes, among other contents. The non-compliant TRU waste contents explicitly included for the OPTIMUS packages are standard aerosol cans and DOT 3E lecture bottles. However, the methods applied for the package containment can be easily adjusted to cover other sealed container types with potentially flammable gases. The primary challenges with including these items are both the obvious issue of potential for flammable gases (e.g. aerosol propellants) in the package, but also the uncertainty in the exact state of the contents. Because these desired contents are waste materials, the characterization of the materials present in the waste may include some uncertainties. For example, though it may be known that there are one or more aerosol cans in a TRU waste drum, it may not be known if this can is full, spent, or anywhere in between. Also there may be equal uncertainty in the contents of the aerosol can, specifically in the potentially flammable propellant remaining in the can. To include these types of non-compliant items as acceptable contents for the package, the methods utilized in the safety analyses of the OPTIMUS packages must consider all of the uncertainties in the characterization of the waste. The methods utilized cover a range of concerns with transporting contents of this nature including pressure buildup, gas generation, and gaseous combustion for demonstrating the containment of the package. The ability to transport these problematic contents in the OPTIMUS packages gives TRU waste generating sites the option to relocate these drums to an offsite location where the non-compliant items can be properly managed through removal or destruction. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of $\nu_\mu$ CC Interactions With Two-Proton Final State in MINERvA

This dissertation presents a measurement of charged–current (CC) muon–neutrino interactions with exactly two protons and no pions in the final state (CC~$2p\,0\pi$), using data collected by the MINERvA detector in the NuMI medium–energy beam at Fermilab. Such two–proton topologies are a sensitive probe of nuclear dynamics in the few–GeV regime, including multi–nucleon correlations (npnh, notably $2p2h$) and intranuclear final–state interactions (FSI) such as pion absorption and nucleon rescattering. A precise experimental characterization of these processes is essential both for neutrino–interaction theory and for reducing systematic uncertainties in oscillation experiments that rely on accurate modeling of neutrino–nucleus interactions. Events are selected by requiring a $\nu_\mu$ CC interaction with a reconstructed $\mu^-$ and two proton tracks originating from a common vertex in MINERvA’s finely segmented scintillator tracker, with no reconstructed mesons. Muon charge and momentum are constrained by matching to the MINOS Near Detector, while proton identification exploits energy–loss profiles and stopping–proton features. Backgrounds from pion–producing channels that enter the signal region through FSI or reconstruction effects are constrained with data–driven sidebands (Michel–electron and isolated–cluster “blob” samples) and tuned via a simultaneous fit across signal and sideband regions. To correct detector resolution and acceptance effects, the analysis employs iterative Bayesian unfolding with extensive validation: statistical pseudo–experiments, and robustness checks against generator systematic “universes” and additional strong shape warps. Single–differential cross sections are reported for three observables tailored to the two–proton final state: the opening–angle cosine $\cos\!\left(\theta_{pp}\right)$, the leading–proton momentum, and the subleading–proton momentum. Systematic uncertainties include contributions from neutrino flux, interaction modeling (e.g., npnh and resonance parameters, pion FSI), and detector response (calibration, reconstruction efficiencies). The resulting distributions provide targeted constraints on the interplay of multi–nucleon dynamics and FSI that shape CC~$2p\,0\pi$ final states on hydrocarbon. Comparisons to modern GENIE–based simulations highlight kinematic regions where model components require refinement. These measurements thus inform generator tuning and improve the reliability of neutrino–energy reconstruction strategies for current and future long–baseline oscillation programs.

Syrotenko, Vladyslav S. [Tufts U.]↗

Hyperspectral Detection of the Fluorescence Shift between Chirality-Sorted Empty and Water-Filled Single-Wall Carbon Nanotube Enantiomers

Single-wall carbon nanotubes (SWCNTs) have extraordinary electronic and optical properties that depend strongly on their exact chiral structure and their interaction with their inner and outer environment. The fluorescence (PL) of semiconducting SWCNTs, for instance, will shift depending on the molecules with which the SWCNT’s hollow core is filled. These interaction-induced shifts are challenging to resolve on the ensemble level in samples containing a mixture of different filling contents due to the relatively large inhomogeneous line width of the ensemble SWCNT PL compared to the size of these shifts. To circumvent this inhomogeneous broadening, single-tube spectroscopy and hyperspectral imaging are often applied, which until now required time-consuming statistical studies. Here, we present hyperspectral PL microscopy combined with automated SWCNT segmenting based on either principal component analysis or a convolutional neural network, capable of both spatially and spectrally resolving the PL along the length of many individual SWCNTs at the same time and automatically fitting peak positions and line widths of individual SWCNTs. The methodology is demonstrated by accurately determining the emission shifts and line widths of thousands of left- and right-handed empty and water-filled SWCNTs coated with a chiral surfactant, resulting in four statistical distributions which cannot be resolved in ensemble spectroscopy of unsorted samples. The results demonstrate a robust method to quickly probe ensemble properties with single-enantiomer spectral resolution. Moreover, it promises to be an absolute quantitative method to characterize the relative abundances of SWCNTs with different handedness or filling content in macroscopic samples, simply by counting individual species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗