Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Systems Integration Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Synopsis of NREL's Automated Mobility District (AMD) Research Program and Associated Publications

An automated mobility district (AMD) envisions a system of integrated mobility options that serves major activity centers such as campuses, central business districts, and large medical facilities. The National Renewable Energy Laboratory (NREL) has been investigating the implementation prospects for fully automated passenger transport systems that are deployed to operate within dense urban settings. This document provides a synopsis of findings revealed over the last three phases of work, which have yielded insights into the creation and management of AMDs anticipated to use automated vehicle (AV) technology over the next decade. Phase I and Phase II tracked the deployment and lessons learned from 10 early-stage demonstrations of automated shuttle deployments, and their associated insights into the challenges for automated driving systems to achieve safe operations within district-scale deployments. Phase III began in-depth investigations of critical subsystem components, as automation, electrification, and on-demand service continue to converge within initial AMD operations. These directed studies focus on elements of electrification, curbfront/station management, the role of infrastructure sensing, and overall integration of AMD safety management in central, simultaneous coordination of multiple AMD fleets. Future research in AMDs includes systems engineering methodology (more frequently referred to as "digital twins") for planning, design, testing, and ongoing operation of AMDs; location (or co-location) of management functions; and human supervision and passenger communications for safety and security in unattended vehicles. The synopsis references the foundational research products (papers and presentations) that have been published through conference proceedings, journal articles, and NREL reports.

33 ADVANCED PROPULSION SYSTEMS↗

Cloud Droplet Measurement System for the ARM Tethered Balloon System (TBS) Field Campaign Report

The Mesa Photonics' cloud droplet measurement system (CDMS) performs in situ measurement of droplet size distribution and droplet number density in clouds. These characteristics are important cloud microphysical properties that are critical input parameters for atmospheric models and are also useful for proper calibration and validation of performance of other atmospheric measurement instrumentation. This small campaign was the first project (out of two) that involved integration of the CDMS into the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s tethered balloon system (TBS) and its initial testing at the ARM Southern Great Plains (SGP) atmospheric observatory. The follow-up campaign (AFC07016) involved testing of the CDMS under relevant conditions at the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska and making in situ measurements in clouds. The goal of this small field campaign was to deploy the CDMS on the ARM TBS, demonstrate its integrity and compatibility with the TBS, and test the wireless telecommunication system in preparation for subsequent in-cloud measurements at ARM’s North Slope of Alaska (NSA) observatory at Utqiagvik (formerly Barrow). The specific technical objectives included: (1) Integration of the Mesa Photonics' CDMS into the ARM TBS, (2) testing of the wireless telecommunication system of the CDMS, (3) evaluating the data acquisition software and image processing algorithms especially under high-background-illumination conditions, and (4) testing the ruggedness of the instrument's optical alignment and other performance characteristics. All objectives have been successfully met. The mounting hardware was designed and built mostly at Sandia National Laboratories (SNL), which allowed reliable mounting of the CDMS on the TBS and co-locating the CDMS with other instruments. The field tests were performed by the principal investigator (PI) in collaboration with the TBS operational crew led by D. Dexheimer. The field testing demonstrated good compatibility of the CDMS with the TBS. During the TBS flights, the crew did not experience any operational issues with the CDMS. The instrument demonstrated reliable operational characteristics, including sufficient battery life and good thermal management. The wireless telecommunication system has been successfully tested at TBS flight altitudes of up to 1000 m. During all flights, the CDMS raw data were wirelessly transmitted to the ground station and processed in real time. The ruggedness of the instrument's optical alignment was evaluated by performing calibration of the CDMS (using Mesa Photonics' fixed-size monodisperse droplet generator) before and after the campaign. The calibration was stable within the instrument's measurement precision. In summary, the campaign demonstrated good compatibility of the Mesa Photonics' CDMS with the ARM TBS. The flight tests confirmed the mechanical integrity of the CDMS and stability of its optical layout, as well as reliability of the wireless telecommunication system. Successful completion of this campaign provided a solid basis for the next campaign (AFC07016, November 2020), that involved testing of the CDMS during in-cloud TBS flights at AMF3 at Oliktok Point.

54 ENVIRONMENTAL SCIENCES↗

2-kW Solar Dynamic Space Power System Tested in Lewis' Thermal Vacuum Facility

Working together, a NASA/industry team successfully operated and tested a complete solar dynamic space power system in a large thermal vacuum facility with a simulated sun. This NASA Lewis Research Center facility, known as Tank 6 in building 301, accurately simulates the temperatures, high vacuum, and solar flux encountered in low-Earth orbit. The solar dynamic space power system shown in the photo in the Lewis facility, includes the solar concentrator and the solar receiver with thermal energy storage integrated with the power conversion unit. Initial testing in December 1994 resulted in the world's first operation of an integrated solar dynamic system in a relevant environment.

Source record↗

1. Physical Security Engineering by Design for Nuclear Facilities; 2. Nuclear Power Plant Site Security Management – A Security Strategy; 3. The UAE Women in Nuclear Energy Security

1. Security by design, or SeBD, is a comprehensive approach that integrates the physical protection system of a nuclear plant into every stage of its existence. This includes planning, designing, constructing, commissioning, and operating the facility, using a combination of analytical, physical, technological, and procedural measures. Essentially, SeBD involves intentionally applying and incorporating security into all aspects of design and operation throughout the entire lifecycle of a facility. By implementing this methodology throughout various phases such as program development, process implementation, staff training and procedures management in conjunction with plant equipment, facilities can be optimized to minimize security risks without compromising functional design requirements. This ultimately improves the overall security posture of the site and reduces the need for costly modifications or additional security resources post-design. 2. A site security strategy is a living document that is revised on a periodic or event-driven basis, ensuring that site security operations and corresponding procedures provide long-term, effective protection for the entire nuclear power plant (NPP) site. A site security strategy aims to mitigate threats across the entire NPP site via in-depth defense approaches and mutual support; therefore, if a layer is omitted or altered, then the effect across all layers must be re-evaluated. Therefore, the aim of the site security strategy is to provide an appropriate, scalable security regime that deters, denies, delays, and detects incidents and, equally importantly, reassures legitimate users and the regulator that due diligence and regulatory compliance have been achieved, ensuring that the site is safe and secure. Robust access control for vehicles and pedestrians is at the heart of the strategy. Vehicle and pedestrian searching and screening are seen as the strongest mitigation methods against vehicle- and pedestrian-borne attacks. The security strategy must also be supported through comprehensive staff training and the development of robust processes, procedures, and planning. If all these measures are to be effective, then training must be implemented during each phase of construction, partial operation/commissioning, and full operation. No single element of site security is completely isolated from the influence of other elements. Ideally, consideration of all key elements will result in a security strategy that is integrated and proportional to the threat and that does not over specify individual security solutions through the application of isolated measures but rather applies a holistic, all-encompassing approach. 3. When women enter the labor force, numerous positive outcomes emerge, including increased GDP, educational gains, and decreased maternal mortality. Despite these benefits, women's employment rates and equality vary significantly worldwide as does support for women in the workforce. This paper will explore the multifaceted benefits of women's employment, the factors influencing labor force participation rates, and the urgency to achieve gender equality as outlined in the 2015 United Nations Sustainable Development Goals (SDGs). It will then examine the emerging presence of women in the traditionally male-dominated nuclear field, specifically within the United Arab Emirates (UAE) as a testament to their resilience and determination to break social norms and advance gender equality.

Zineddin, Dr. Z.↗

System-Integrated Finite Element Analysis of a Full-Scale Helicopter Crash Test with Deployable Energy Absorbers

A full-scale crash test of an MD-500 helicopter was conducted in December 2009 at NASA Langley's Landing and Impact Research facility (LandIR). The MD-500 helicopter was fitted with a composite honeycomb Deployable Energy Absorber (DEA) and tested under vertical and horizontal impact velocities of 26-ft/sec and 40-ft/sec, respectively. The objectives of the test were to evaluate the performance of the DEA concept under realistic crash conditions and to generate test data for validation of a system integrated finite element model. In preparation for the full-scale crash test, a series of sub-scale and MD-500 mass simulator tests was conducted to evaluate the impact performances of various components, including a new crush tube and the DEA blocks. Parameters defined within the system integrated finite element model were determined from these tests. The objective of this paper is to summarize the finite element models developed and analyses performed, beginning with pre-test predictions and continuing through post-test validation.

Annett, Martin S.↗

Multiscale Experiments and Multiphysics Simulation of Multiphase Flow for Transportable Small Modular Reactors

A new type of safe, small, transportable nuclear reactor would address the intense and ever-growing global demand for energy produced via a resilient, carbon-free energy source. In this regard, transportable small modular reactors (SMRs) are being designed and developed for electricity generation within small/micro-grid/off-grid isolated systems, as well as for heat generation in industrial/residential applications. These reactors feature the capability to be fully factory fabricated and then directly transported to utilities’ sites as “plug-and-play” systems. Research and development (R&D) programs are underway at Idaho National Laboratory (INL) to successfully design, develop, and demonstrate such safe-by-design mobile reactor technologies, in collaboration with partner organizations. Multiscale experimental facilities and multiphysics simulation tools are required for reactor design verification and validation (V&V), and licensing. These advanced reactors are intended to feature passive safety systems such as passive containment cooling systems (PCCS), which consist of multiphase flows and multispecies distributions. This seminar talk will focus on designing and analyzing transportable SMR PCCS by using multiscale experiments and multiphysics computational fluid dynamics (CFD) simulations to support reactor licensing and safety. The corresponding research challenges are addressed via supportive verification and validation results generated by the models and simulation tools in combination with selective parametric and uncertainty analysis. This solution approach could blaze the trail for commercial adoption of such technologies. The facilities, simulation capabilities, and research opportunities available at INL in regard to such reactors and the integrated energy systems with which they go hand in hand are also discussed briefly, and may spark interest in deeper research as well as new collaborative projects.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Summary of Consolidated Interim Storage Advantages and Disadvantages from an Integrated Systems Perspective from Prior Reports and Studies

The question of whether centralized storage of civilian spent nuclear fuel (SNF) should be part of the federal waste management system as an intermediate step before permanent disposal has been debated for more than four decades. Centralized storage facilities were included as a potential component of the U.S. spent fuel management system in the Nuclear Waste Policy Act of 1982 (NWPA), but these facilities were not identified as being essential. When the NWPA was passed, it was expected that a permanent repository would be available around the turn of the century to meet the commitments that were made to start accepting waste by that time. For a number of reasons, a permanent repository was not available at that stage. This report summarizes the advantages and disadvantages of including an ISF as part of an integrated waste management system that have been identified in numerous analyses of the impacts of a consolidated interim storage facility (ISF), previously discussed as monitored retrievable storage, the form of ISF authorized in the NWPA) by the U.S. Department of Energy (DOE) and independent groups. Storing SNF before disposal is a functional requirement for an integrated waste management system. As described below, the studies reviewed in this report have identified a range of benefits that could be obtained by adding a consolidated ISF to the waste management system, including (1) earlier acceptance of fuel by the federal government, (2) reduction in the number of unintended long-term storage sites, (3) added system flexibility and opportunity for better integration, and (4) near-term development and demonstration of institutional and technical infrastructures for large-scale management of SNF. At the same time, these studies have identified potential drawbacks to deployment of an ISF, including (1) potential adverse impacts on development of a repository, (2) additional transportation of SNF, and (3) a large upfront economic investment to establish the consolidated storage capability. In general, the studies that have considered the positive and negative impacts of consolidated storage most comprehensively have concluded that in light of these considerations, the benefits of including an ISF as part of an integrated waste management system can outweigh any real or perceived disadvantages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nepal Himalaya offers considerable potential for pumped storage hydropower

There is a pressing need for a transition from fossil fuel to renewable energy to meet the increasing energy demands and reduce greenhouse gas emissions. The Himalayan region, with its unique topography and abundant water resources, offers substantial renewable energy potential, particularly through hydropower generation. However, the current exploitation rate is low owing to the predominance of run-of-river hydropower systems to support the power system. The utility-scale storage facility is crucial in the load scenario of an integrated power system to manage diurnal variation, peak demand, and penetration of intermittent energy sources. In this study, we assess the potential of pumped storage hydropower across Nepal, a central Himalayan country, under multiple configurations by pairing lakes, rivers, and available flat terrains. We then identify technically feasible pairs from those of potential locations. Infrastructural, environmental, operational, and other technical constraints govern the choice of feasible locations. Here, we show that 42% of the theoretical potential of 3000 GWh is technically feasible. We find the flat land-to-river configuration more promising than other configurations. Our findings provide insight into the potential of pumped storage hydropower and are of practical importance in planning sustainable power systems in the Himalayas and beyond.

13 HYDRO ENERGY↗

Validation and Verification of TEDS Facility HYBRID Modeling

The HYBRID modeling repository is an in-house developed library of models for selected integrated energy systems (IES) modelling. HYBRID models have been developed since 2015 to describe the physical operation of tightly coupled thermal systems including power generators, thermal transport systems, thermal storage, thermal-to-electric conversion systems, and other thermal applications. Here, validation and verification (V&V) capabilities are demonstrated using the Thermal Energy Distribution System (TEDS) at INL. Building upon prior work, the TEDS model has been updated and verified so that it better represents the installed system configuration and the operating control system. The model control system was changed to allow replication of actual experimental procedures. Experimental operations focusing primarily on thermocline tank performance were devised and performed. Several anomalies were found in the operation data of the experiment facility. V&V activities calibrating a selected input parameter are demonstrated on a single component as well as with a single parameter within the thermocline. Calibrating is then demonstrated on multiple components and a multi-parameter metric for the entire system. The validation methodology is successfully applied to validate the model with experimental data. It is also used to confirm a hypothesis behind one of the anomalies in experimental performance.

25 ENERGY STORAGE↗

A preliminary systems-engineering study of an advanced nuclear-electrolytic hydrogen-production facility

An advanced nuclear-electrolytic hydrogen-production facility concept was synthesized at a conceptual level with the objective of minimizing estimated hydrogen-production costs. The concept is a closely-integrated, fully-dedicated (only hydrogen energy is produced) system whose components and subsystems are predicted on ''1985 technology.'' The principal components are: (1) a high-temperature gas-cooled reactor (HTGR) operating a helium-Brayton/ammonia-Rankine binary cycle with a helium reactor-core exit temperature of 980 C, (2) acyclic d-c generators, (3) high-pressure, high-current-density electrolyzers based on solid-polymer electrolyte technology. Based on an assumed 3,000 MWt HTGR the facility is capable of producing 8.7 million std cu m/day of hydrogen at pipeline conditions, 6,900 kPa. Coproduct oxygen is also available at pipeline conditions at one-half this volume. It has further been shown that the incorporation of advanced technology provides an overall efficiency of about 43 percent, as compared with 25 percent for a contemporary nuclear-electric plant powering close-coupled contemporary industrial electrolyzers.

Escher, W. J. D.↗

Direct Air Capture Recovery of Energy for CCUS Partnership (DAC RECO 2 UP) Final Technical Report

The “Direct Air Capture Recovery of Energy for CCUS Partnership (DAC RECO 2 UP)” project employs a team approach and supports the U.S. Department of Energy Office of Fossil Energy and Carbon Management’s (DOE-FECM) goal to decrease the cost of capture through the testing of existing direct air capture (DAC) materials in integrated field units that produce a concentrated carbon dioxide (CO 2 ) stream of at least 95% purity. Solid-amine CO 2 adsorption-desorption contactor technology, proven in the laboratory, is undergoing high-fidelity design/validation. Recoverable energy is readily available from a large number of commercial locations where DAC can be deployed; therefore, advancing the fidelity of energy recovery to directly reduce the cost of DAC is a key project objective. In addition, many commercial facilities have low-concentration CO 2 vents that are uneconomical to treat alone but could provide more efficient mass and thermal transport to DAC systems with integrated energy recovery and flexible CO 2 treatment capabilities. Technology scale-up leverages past research and occurs in a commercially relevant environment at the National Carbon Capture Center. Prescreening techno-economic analysis, risk assessments, and life cycle analysis are being performed by experienced team members. Results of the project will address critical technical barriers that, when solved, will improve the capital and operating costs of DAC while validating commercial relevance of cost and product quality/need.

54 ENVIRONMENTAL SCIENCES↗

Deer Park Energy Center Natural Gas Combined Cycle Carbon Capture System Front-End Engineering Design Study (Final Scientific/Technical Report – Unlimited)

Calpine Texas CCUS Holdings, LLC (Calpine), Shell Catalysts & Technologies (SCT), Technip Energies (TEN), and Sargent & Lundy, LLC (S&L) have conducted a Front-End Engineering Design (FEED) Study to integrate a new carbon capture system at Calpine’s Deer Park Energy Center (DKEC). The DKEC facility is a nominal 1200 MW gas-fired co-generation power plant situated at the Shell Chemical Manufacturing (Shell) Facility located in Deer Park, Texas. Steam is produced for use by the adjacent Shell Chemical Manufacturing Facility as well as by the onsite steam turbine for electrical generation. The power output from DKEC is provided to the Electric Reliability Council of Texas (ERCOT) operated power grid. DKEC provides power to industrial and commercial customers via this interconnection.

03 NATURAL GAS↗

Evaluation of the Turbine Integrated Mortality Reduction (TIMR SM ) Technology as a Smart Curtailment Approach (Final Summary Report)

Wind energy is a crucial technology for achieving net-zero emissions by 2050. However, the growth and deployment of wind energy in North America have led to the deaths of many bat species due to operating wind turbines. Hundreds of thousands of bats are estimated to die at wind turbines annually in North America. Operational minimization, which includes feathering turbine blades and curtailment, has been documented to reduce bat fatality effectively. Curtailment refers to altering turbine operation based on wind speed, time of year, temperature, sensors, and activity models. However, when turbines are curtailed, they do not generate power, resulting in energy loss and revenue for wind energy facilities. The Electric Power Research Institute (EPRI) funded the development of Turbine Integrated Mortality Reduction (TIM SM ) Technology, which curtails turbine operation when bats are detected. The initial TIMR system research showed promising results, with an 85% reduction in overall bat fatalities and a 91% reduction for the little brown bat. However, these results were based on a single site during one fall season, and it was unclear if similar results could be replicated at other wind energy facilities. This research aimed to validate the TIMR system results from the prior field study at a second site in the U.S., estimate the power production and reduction in bat mortality at turbines with installed TIMR systems relative to blanket curtailment and fully operational turbines, test the TIMR system in two calendar years and during the summer and fall periods, and evaluate the operational and commercial characteristics of the TIMR system for potential wind industry adoption. The study was conducted at a 500.9-MW wind energy facility in southeast Adair County, Iowa. Three experimental treatments were involved in this randomized block design study: TIMR, Curtailment at 5.0 m/s, and Normal Operation. In 2021, three treatments were used at 18 turbines, expanding to four treatments across 36 turbines in 2022. The TIMR system worked as designed throughout the entire study; however, because of unexpected wind turbine operational challenges in 2021, there was not sufficient sample size to evaluate the treatment differences. In 2022, there were significant differences in fatality levels between treatment types and normal operating turbines. Curtailment at 5.0 m/s reduced fatalities by 30.8% compared to normal operations, and TIMR decreased fatalities by 48.6% compared to normal operations. Two different methods were used to evaluate the differences in energy loss for each treatment. The TIMR system resulted in 1.3% to 1.6 % annual energy loss in 2021 and 1.0% to 1.2 % in 2022. The Curtailment at 5.0 m/s resulted in 0.6% to 0.8 % annual energy loss in 2021 and 0.5% to 0.6 % in 2022. The project achieved all the stated objectives and demonstrated that TIMR is an effective technology that balances bat fatality reduction with energy generation. The results will support the deployment of TIMR and other acoustic sensor-based technologies. The research provides valuable insights into the impact of different treatments on fatality rates and energy outputs, contributing to the ongoing efforts to mitigate the environmental impact of wind energy.

17 WIND ENERGY↗

DETAIL Component Scaling and Methodology Comparison

The purpose of this study was to develop a process to convert input signals from one facility into another by reflecting geometric and environmental settings. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is a research facility in development. Its aim is to emulate the daily interactions among power production industry systems and receive real-time data from those systems as inputs. To convert signals and ensure that the temporal sequences and magnitudes reflect laboratory settings, the ability to scale and project data is essential. To demonstrate this ability, Dynamical System Scaling (DSS) and Hierarchical Two-Tiered Scaling (H2TS) (methodologies that enable systems to scale and project or extrapolate data sets to desired environments while conserving the observed behavior based on first principles) were applied to DETAIL’s thermocline thermal storage system in the Thermal Energy Distribution System (TEDS) facility and solid-oxide electrolysis cell in the High Temperature Hydrogen Electrolysis (HTHE) facility. Both thermocline and electrolysis cell systems were successfully scaled, and test cases were conducted to generate a doubly accelerated energy charge and discharge in reference to past experimental data from the facilities. The research results represented a case for the thermocline system that required signals to be accelerated without altering the stored energy. To enhance the quality of the accelerated data, error propagation analyses were conducted on DSS post-processing terms to determine the consequences of raw-data-associated errors.

08 HYDROGEN↗

Data Projection of the High Temperature Electrolysis System in the Dynamic Energy Transport and Integration Laboratory using Dynamic System Scaling

For nuclear power to be flexible in a functioning Integrated Energy System (IES), excess produced heat must be stored or utilized during times of low power demand to ensure a load factor of 1 while load balancing. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility that is under development to emulate IES conditions on the engineering-scale, planned to conduct virtual real time operations with industry-scale facilities, and is currently testing thermal storage and high temperature electrolysis. As part of the study to develop a method to preprocess input signals or postprocess output signals between systems of different scales via Dynamical System Scaling (DSS), the current research is one of the continued efforts branching from the data projection activity conducted for the Thermal Energy Distribution System and currently engages the High Temperature Electrolysis (HTE) System in DETAIL. The HTE SOEC electrical, fluid, and thermal dynamics Figure of Merits (FOM) were identified, governing equations and closure relations were successfully scaled, and relations between FOM scaling ratios were determined. Setting the scaling objectives to reform existing data to project a data set that doubly accelerated the electrolysis process while preserving the produced amount of hydrogen was generated for the full transient. The calculated boundary conditions were inlet temperature, stack current, and inlet steam mass flow rate at 1470 K, 121.1 A, and 1.886 g/s, respectively. The research outcomes demonstrated an output signal postprocessing case accelerating the hydrogen production without changing geometry, number of cells, and partial pressures.

08 HYDROGEN↗

Tethered Balloon System Merged Data (TBSMERGED) Value-Added Product Report

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Tethered Balloon System Merged Data (TBSMERGED) Value-Added Product (VAP) integrates data from instruments flown on ARM’s tethered balloon system missions that collect in situ measurements of temperature, humidity, wind speed, wind direction, and aerosol properties with estimates of cloud base and boundary-layer height from a surface-based ceilometer to improve the ease of use of tethered balloon system (TBS) data sets. The TBSMERGEDINCLOUD VAP, a variation of TBSMERGED, includes supercooled liquid water content (tbsslwc) measurements collected within the cloud.

54 ENVIRONMENTAL SCIENCES↗

Economic Evaluation of a Coupled Nuclear Power Plant and Hydrogen Production Facility: A Case Study

This study optimized the design sizes and operation of a power-to-hydrogen-to-power integrated energy system to allow a baseload power plant to operate flexibly in the energy market. In collaboration with a utility industry partner, the system, consisting of an electrolyzer, compressors, storage tank, and fuel cell, was optimized under conditions specific to the proposed project at the site of a nuclear power plant. The Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES) maximized net present value by optimizing sizing of components and dispatch decisions. Revenues included sale of electricity, capacity payments typical of the New York Independent System Operator, and the section 45V hydrogen production tax credit of the Inflation Reduction Act of 2022 (the tax credit was assumed to be available to legacy plants in the absence of clear guidance at present). Under default assumptions which excluded many capital expenditures, the base case optimized solution had a net present value of $\$$1.4 million over a 30 year lifetime, with a 0.365 MW fuel cell operating nearly continuously and 85% of revenues supplied by the hydrogen production tax credit (which was counted as a revenue regardless of profit, thus assuming credit monetization or offset of taxes within the larger firm was possible in all years). Beyond the base case, a sensitivity study elucidated drivers of the economics as capacity payment rate and hydrogen production tax credit rate vary. Additional sensitivity studies also extended results to variation of other, previously fixed parameters, including the fuel cell capital cost, and to imposition of further constraints. Optimization was also repeated for the default assumptions but recognizing tax credits upon use of hydrogen rather than upon its production, producing no change in the optimal solution. Most notably, capacity payments above $\$$15/kW-month drove optimal fuel cells multiple times larger than those with the default estimated capacity payment of $\$$2.5/kW-month (approaching 11 vs. 0.365 MW), and these larger fuel cells operated rarely (capacity factors of ~0.03). Furthermore, when the hydrogen production tax credit was provided for only 10 years, under the specific assumptions of this study (e.g., neither site preparation costs nor electrolyzer capital cost counted), the optimal solution avoided economic loss by ceasing system operation after the 10th year. Viewed broadly, this study demonstrated the capabilities of DISPATCHES, which can be user-adapted to serve other industrial case studies.

08 HYDROGEN↗

Real time side-by-side experimental validation of energy and comfort performance of a zero net energy retrofit package for small commercial buildings

Making buildings zero-net energy (ZNE) is one of the major strategies for achieving carbon emission reduction goals. For this strategy to be successful, it entails a very significant reduction in energy use – 50% or more. In small commercial buildings, however, owners and building management teams usually have limited resources for identifying, analyzing, and procuring appropriate retrofit measures for reducing such use. An approach to overcome this limitation is the development of bundles of energy efficiency measures that can be presented to building owners/operators as a comprehensive package. The research presented in this paper focuses on an experimental evaluation of the impacts of a retrofit package developed for small office buildings in California. Performing this evaluation in a full-scale whole-building integrated systems test facility allowed a side-by-side evaluation in real time, against a reference case, of the impact of the retrofit package not only on energy use but also on visual and thermal comfort. Here, the retrofit package evaluated is comprised of a combination of HVAC, lighting (including daylighting), and plug load measures. The evaluation occurred at different times of the year in order to account for seasonal variations in environmental conditions, including solar angles and weather. The experimental facility allowed testing for two different façade orientations: south and west. Results show that the proposed ZNE retrofit package can save significant amounts of energy for small commercial buildings. During cooling-prevalent periods, total energy savings were 65% for south orientation and 68% for west orientation; during heating-prevalent periods total energy savings were 22% for south orientation and 25% for west orientation. Measurements indicate that the ZNE retrofit package resulted in small but not very significant changes in comfort levels for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗