Levelized Cost of Energy Analysis of Marine and Hydrokinetic Reference Models: Preprint

In 2010 the U.S. Department of Energy initiated the development of six marine energy converter reference models. The reference models are point designs of well-known marine energy converters. Each device was designed to operate in a specific marine resource, instead of a generic device that can be deployed at any location. This method allows each device to be used as a benchmark for future reference model to benchmark future devices. The six designs consist of three current energy converters and three wave energy converters. The reference model project has generated both technical and economic data sets that are available in the public domain. The methodology to calculate the levelized cost of energy for the reference model project and an overall comparison of the cost of energy from these six reference-model designs are presented in this paper.

13 HYDRO ENERGY↗

NREL Data, Modeling, and Tools Empower Marine Energy Analysis

NREL performs R&D and economic analyses to drive and empower the development of wave energy and tidal, ocean, and river current energy technologies. These technologies deliver renewable electricity to the grid and provide energy solutions that support the evolving "blue economy."

HYDRO ENERGY↗

Retrofit Energy Analysis and Central Thermal modeling (REACT) v1.0

REACT is a website designed to simplify the analysis and decision-making process for retrofitting existing central plant heating and cooling systems with advanced heat pump technologies. The tool evaluates the technical and economic viability of replacing traditional boilers with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. Retrofitting traditional boiler and chiller systems with water-to-water or air-to-water heat pumps can significantly reduce energy consumption and lower lifecycle costs. The REACT provides: User-Friendly Tools: A user friendly web interface for quick, intuitive analysis accessible to non-experts. Advanced Modeling: A Python-powered engine for detailed parametric studies, optimization, and research applications. Comprehensive Analysis: Lifecycle cost evaluation, energy consumption modeling, and environmental impact assessment. Visual Insights: A variety of plots to visualize system performance and design trade-offs. The engine for the website (REACT) bases on several Python libraries, and the website will be hosted on an ETA server.

Kim, Donghun [Lawrence Berkeley National Laborator↗

Beam Position Monitor and Energy Analysis at the Fermilab Accelerator Science and Technology Facility

Fermilab Accelerator Science and Technology Facility has produced its first beam with an energy of 20 MeV. This energy is obtained by the acceleration at the Electron Gun and the Capture Cavity 2 (CC2). When fully completed, the accelerator will consist of a photoinjector, one International Liner Collider (ILC)-type cryomodule, multiple accelerator R&D beamlines, and a downstream beamline to inject 300 MeV electrons into the Integrable Optics Test Accelerator (IOTA). We calculated the total energy of the beam and the corresponding energy to the Electron Gun and CC2. Subsequently, a Beam Position Monitors (BPM) error analysis was done, to calculate the device actual resolution.

43 PARTICLE ACCELERATORS↗

Traveling Wave Energy Analysis of Faults on Power Distribution Systems

This paper explores the most important factors that define the Traveling Wave (TW) propagation on distribution systems. The factors considered in this work are: the distance to the fault location, the fault type, and the crossing of system elements (such as regulators, capacitor banks, laterals, and extra loads within the protection zones). This work uses a realistic, yet simplified, distribution system composed of two protection zones, in which, several combinations of the previously mentioned factors are considered. The simulated fault measurements undergo a signal processing stage in which, first, they are decomposed into independent modes using the Karrenbauer transform. Second, a time–frequency representation is obtained using the Stationary Wavelet Transform (SWT), dividing the signal into several frequency bands. Finally, the Parseval’s Energy (PE) theorem is applied to calculate the signal energy in each frequency band. A qualitative analysis is performed based on the previously calculated energies to outline which are the factors that most affect the TW energy during propagation. The results show that distance, the presence of regulators, either in the propagation path or upstream, and the type of fault are the main factors that affect TW propagation across the system, and therefore they should be considered for TW-based protection schemes for distribution systems.

Jiménez-Aparicio, Miguel (ORCID:000000016864461X)↗

An integral turbulent kinetic energy analysis of free shear flows

Mixing of coaxial streams is analyzed by application of integral techniques. An integrated turbulent kinetic energy (TKE) equation is solved simultaneously with the integral equations for the mean flow. Normalized TKE profile shapes are obtained from incompressible jet and shear layer experiments and are assumed to be applicable to all free turbulent flows. The shear stress at the midpoint of the mixing zone is assumed to be directly proportional to the local TKE, and dissipation is treated with a generalization of the model developed for isotropic turbulence. Although the analysis was developed for ducted flows, constant-pressure flows were approximated with the duct much larger than the jet. The axisymmetric flows under consideration were predicted with reasonable accuracy. Fairly good results were also obtained for the fully developed two-dimensional shear layers, which were computed as thin layers at the boundary of a large circular jet.

Peters, C. E.↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed Resource Energy Analysis and Management System (DREAMS) Development for Real-time Grid Operations

This project supports development of the next generation, integrated energy management infrastructure (EMS) able to incorporate advance visualization of behind-the-meter distributed resource information and probabilistic renewable energy generation forecasts to inform real-time operational decisions. The project involves end-users and active feedback from an Utility Advisory Team (UAT) to help inform how information can be used to enhance operational functions (e.g. unit commitment, load forecasting, Automatic Generation Control (AGC) reserve monitoring, ramp alerts) within two major EMS platforms. Objectives include: Engaging utility operations personnel to develop user input on displays, set expectations, test and review; Developing ease of use and timeliness metrics for measuring enhancements; Developing prototype integrated capabilities within two operational EMS environments; Demonstrating an integrated decision analysis platform with real-time wind and solar forecasting information and timely distributed resource information; Seamlessly integrating new 4-dimensional information into operations without increasing workload and complexities; Developing sufficient analytics to inform and confidently transform and adopt new operating practices and procedures; Disseminating project lessons learned through industry sponsored workshops and conferences;Building on collaborative utility-vendor partnership and industry capabilities

14 SOLAR ENERGY↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

Multi-degree of Freedom Energy Analysis for Identification of Failure Risk in Structural Components Subjected to Random Vibration and Shock Loading

When designing or analyzing a mechanical system, energy quantities provide insight into the severity of shock and vibration environments; however, the energy methods in the literature do not address localized behavior because energy quantities are usually computed for an entire structure. The main objective of this paper is to show how to compute the energy in the components of a mechanical system. The motivation for this work is that most systems fail functionally due to component failure, not because the primary structure was overloaded, and the ability to easily compute the spatial distribution of energy helps identify failure sensitive components. The quantity of interest is input energy. That input energy can be decoupled modally is well known. What is less appreciated is that input energy can be computed at the component level exactly, using the component effective modal mass. We show the steady state input energy can be decomposed both spatially and modally and computed using input power spectra. A numerical example illustrates the spatial and modal decomposition of input energy and its utility in identifying components at risk of damage in random vibration and shock environments. Our work shows that the modal properties of the structure and the spectral content of the input must be considered together to assess damage risk. Because input energy includes absorbed energy as well as relative kinetic energy and dissipated energy, it is the recommended energy quantity for assessing the severity for both random vibration and shock environments on a structure.

42 ENGINEERING↗

Quantifying Systemic Efficiency using Exergy and Energy Analysis for Ground Source Heat Pumps: Domestic Space Conditioning and Water Heating Applications.

Although air temperatures over land surfaces show wide seasonal and daily variations, the ground, approximately 10 meters below the earth s surface, remains relatively stable in temperature thereby serving as an energy source or sink. Ground source heat pumps can heat, cool, and supply homes with hot water efficiently by utilizing the earth s renewable and essentially inexhaustible energy resources, saving fossil fuels, reducing greenhouse gas emissions, and lowering the environmental footprint. In this paper, evidence is shown that ground source heat pumps can provide up to 79%-87% of domestic hot water energy needs, and up to 77% of space heating needs with the ground s thermal energy resources. The case refers to a 12-month study conducted at a 253 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days and CDD of 723 C-days under simulated occupancy conditions. A single 94.5m vertical bore interfaced the heat pump with the ground. The research shows that this technology is capable of achieving US DOE targets of 25 % and 35% energy savings in HVAC, and in water heating, respectively by 2030. It is also a viable technology to meet greenhouse gas target emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources. The paper quantifies systemic efficiencies using Exergy analysis of the major components, clearly pointing areas for further improvement.

exergy↗

Computerized energy analysis for the Mars operations support building

A detailed computerized building load simulation of the Operations Support Building at the Mars Deep Space Station, Goldstone, California is described. Five energy conservation suggestions were investigated prior to implementation. The results showed that cost savings of about 16 percent of present energy costs are possible.

Yung, C. S.↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Unlock Expert Energy Analysis with REopt Lite

NREL’s REopt Lite software is a free online tool designed to help building owners, developers, utilities, and researchers find the most cost-effective and resilient energy solution for a specific site. REopt Lite evaluates the economic viability of solar PV, battery storage, and wind energy at a site, identifies system sizes and battery dispatch strategies to minimize energy costs, and estimates how long a system can sustain a site’s critical load during a grid outage. The software delivers powerful insights with as few as three site-specific inputs, allowing users to evaluate the tradeoffs between initial capital expenditures and reduced utility costs over the project lifetime.

97 MATHEMATICS AND COMPUTING↗

Exploring New Ways to Classify Industries for Energy Analysis and Modeling

As the US moves closer to embracing a net zero greenhouse gas emissions position, combustion processes outside the power sector are becoming urgent concerns. Industry is an important end user of energy and relies on fossil fuels used directly for process heating and as feedstocks for a diverse range of applications. Fuel and energy use by industry is heterogeneous, meaning that even a single product group can vary broadly in its production routes and associated energy usage. In the US, the North American Industry Classification System (NAICS) serves as the basis for data collection and reporting. In turn, data based on NAICS is the foundation of most US energy modeling. Thus, the effectiveness of NAICS at representing energy use is a limiting condition for plans to improve energy efficiency and alternatives to fossil fuels in industry. Facility-level data to build more detail into heterogeneous sectors is scarce. This work explores alternative classification schemes for industry based on energy use characteristics, and provides a validation of an approach to make facility-level energy use estimates based on publicly available data from the greenhouse gas reporting program. First, several approaches to industrial taxonomies and their usefulness for industrial energy modeling are summarized. Data from Industrial Assessment Centers is analyzed using unsupervised machine learning techniques to detect clusters. Cladistics, an approach from biology, is adapted to energy and process characteristics of industries. A cladogram is presented for evolutionary directions in the iron and steel sector. Cladograms are a promising tool for constructing scenarios and summarizing directions of sectoral innovation. Finally, validation is performed for facility-level energy estimates from the US EPA Greenhouse Gas Reporting Program. This validation assists in making this data source available for use in energy modeling. Together, this work explores alternative approaches for categorizing industries in a way that aids understanding energy use, and presenting pathways for the future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A kinetic energy analysis of the meso beta-scale severe storm environment

Analyses are performed of the meso beta-scale (20-200 km wavelengths and several hours to one-day periods) severe storm kinetic energy balance on the fifth day of the AVE SESAME campaign of May 1979. A 24-hr interval covering the antecedent, active and post-convective outbreak activity over Oklahoma are considered. Use is made of the kinetic energy budget equation (KEBE) for a finite volume in an isobaric coordinate system. Rawindsonde data with 75 km resolution were treated. The KEBE model covered changes in kinetic energy due to the cross contour flows, horizontal and vertical components of flux divergence, and volumic mass changes on synoptic and subsynoptic scales. The greatest variability was concentrated above 400 mb height and over the most intense storm activity. Energy was generated at the highest rates in divergence and decreased the most in convection. The meso beta-scale lacked sufficient resolution for analyzing mesoscale activity.

Fuelberg, H. E.↗