Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “End Use Load Profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Machine learning surrogate of physics-based building-stock simulator for end-use load forecasting

Building energy models are used to simulate heat and mass transfer and estimate end-use load in buildings. With the proliferation of solar photovoltaics on residential and commercial buildings, increasingly, buildings are expected to provide grid services, for which accurate and computationally efficient building energy simulations and end-use load prediction are imperative. Existing building energy simulation tools, however, have significant computational overhead that make them less practical in real-time deployment for optimization, design, uncertainty quantification and control in building energy management systems. Here this article presents a data-driven machine learning model based on light gradient boosting method (LightGBM) as a surrogate for a physics-based simulator for residential buildings to predict end-use load. The machine learning based surrogate model accounts for time-series related variables, seasonality and trend component of end-use load, and history of end-use load. The accuracy of the surrogate model is assessed on the prediction of the load profiles of 100 different houses in Cook County, Illinois, USA. The LightGBM surrogate model is shown to reduce the root-mean-squared error by 53% relative to a reference decision tree (DT) based model reported previously in the literature. Moreover, the model predicts the load spikes and high-ramp rate events throughout the year which are often the Achilles heel of other models in the literature. The machine learning based surrogate model is demonstrated to be computationally efficient, with a ten-fold reduction in the computational time compared to a physics-based building energy simulation, and suitable for uncertainty analysis and real-time control of building characteristics in response to uncertainty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Caldera Infrastructure Charge Module (ICM)

Caldera ICM is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. The foundation of Caldera ICM is it’s first-of-its-kind library of high-fidelity charging models for a wide variety of vehicles, validated by test data under a range of operating conditions. The charging models are used to accurately model the EV charging on an electric vehicle supply equipment (EVSE) – also known as a charger. ICM uses as inputs, the EV characteristics such as battery size, battery chemistry (i.e. NMC, LTO), watt hour per mile, inverter efficiency and max charge rate; as well as EVSE characteristics such as max current and supply equipment type (i.e. L2 vs XFC). Using these inputs Caldera ICM creates an uncontrolled charging profile curve for each compatible EV-EVSE pair. These charge profiles can be used stand alone to estimate charge duration given start State Of Charge (SOC) and end SOC or charge energy size given start SOC and charge duration. In Caldera Grid, another tool in the Caldera software platform, these charge profiles are used to represent EV charging as a load on the grid using charge event data such as EV type, SE type, start SOC, final SOC, park start time and park end time. ICM currently supports energy shifting Smart Charge Management (SCM) strategies such as "Time Of Use (TOU) immediate”, “TOU random” and “random start” by delaying the charge to start at a preferable time with respect to the strategy and, one voltage support SCM strategy named autonomous voltage control strategy by providing reactive power back to the electric grid.

Sundarrajan, ManojKumar Cebol↗

Electrification Futures Study: Methodological Approaches for Assessing Long-Term Power System Impacts of End-Use Electrification

By its nature, electrification enhances the coupling between the electric sector and end-use sectors. Assessing the impacts of electrification requires both an examination of the complex interactions between sectors and a broader assessment of multiple parts of the energy system. The Electrification Futures Study (EFS) uses several complementary modeling and analysis tools to analyze the impacts of electrification on the U.S. energy system. In particular, the EFS relies on an overarching scenario analysis approach, but through the use of separate modeling approaches designed to assess various electricity demand- and supply-side futures. The primary model employed to generate the supply-side scenarios is the Regional Energy Deployment System (ReEDS) model, which is a capacity expansion model for the U.S. electricity system through 2050. Traditionally, the model has been primarily exercised in scenario analysis that implicitly assumed limited electrification. Because of this assumption, resulting future load profiles are approximated by historical ones, load growth is driven primarily by population and economic growth only, and changes in direct end-use natural gas consumption do not effect natural gas costs for electricity generation. In this report, we (1) reflect the potential for resource sharing between regions given these changes in demand, (2) represent how changes in natural gas consumption in end-use sectors could impact the economics of natural gas-fired generation, and (3) document a new model representation of demand-side flexibility used for the EFS. These improvements to ReEDS are employed for the EFS supply-wide analysis, which is summarized in a companion EFS report titled Electrification Futures Study: Scenarios of Power System Evolution and Infrastructure Development for the United States (Murphy et al. 2019). The data and methods documented in this report could also be adapted for other models with similar scope and limitations as ReEDS, and these data and methods could be used to assess future electric system scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conceptual Waste Packaging Options for Deep Borehole Disposal

This report presents four concepts for packaging of radioactive waste for disposal in deep boreholes. Two of these are reference-size packages (11 inch outer diameter) and two are smaller (5 inch) for disposal of Cs/Sr capsules. All four have an assumed length of approximately 18.5 feet, which allows the internal length of the waste volume to be 16.4 feet. However, package length and volume can be scaled by changing the length of the middle, tubular section. The materials proposed for use are low-alloy steels, commonly used in the oil-and-gas industry. Threaded connections between packages, and internal threads used to seal the waste cavity, are common oilfield types. Two types of fill ports are proposed: flask-type and internal-flush. All four package design concepts would withstand hydrostatic pressure of 9,600 psi, with factor safety 2.0. The combined loading condition includes axial tension and compression from the weight of a string or stack of packages in the disposal borehole, either during lower and emplacement of a string, or after stacking of multiple packages emplaced singly. Combined loading also includes bending that may occur during emplacement, particularly for a string of packages threaded together. Flask-type packages would be fabricated and heat-treated, if necessary, before loading waste. The fill port would be narrower than the waste cavity inner diameter, so the flask type is suitable for directly loading bulk granular waste, or loading slim waste canisters (e.g., containing Cs/Sr capsules) that fit through the port. The fill port would be sealed with a tapered, threaded plug, with a welded cover plate (welded after loading). Threaded connections between packages and between packages and a drill string, would be standard drill pipe threads. The internal flush packaging concepts would use semi-flush oilfield tubing, which is internally flush but has a slight external upset at the joints. This type of tubing can be obtained with premium, low-profile threaded connections at each end. The internal-flush design would be suitable for loading waste that arrives from the originating site in weld-sealed, cylindrical canisters. Internal, tapered plugs with sealing filet welds would seal the tubing at each end. The taper would be precisely machined onto both the tubing and the plug, producing a metal-metal sealing surface that is compressed as the package is subjected to hydrostatic pressure. The lower plug would be welded in place before loading, while the upper plug would be placed and welded after loading. Conceptual Waste Packaging Options for Deep Borehole Disposal July 30, 2015 iv Threaded connections between packages would allow emplacement singly or in strings screwed together at the disposal site. For emplacement on a drill string the drill pipe would be connected directly into the top package of a string (using an adapter sub to mate with premium semi-flush tubing threads). Alternatively, for wireline emplacement the same package designs could be emplaced singly using a sub with wireline latch, on the upper end. Threaded connections on the bottom of the lowermost package would allow attachment of a crush box, instrumentation, etc.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗

Development of fundamental power coupler for high-current superconducting RF cavity

Brookhaven National Laboratory took a project of developing a 704 MHz five-cell superconducting RF cavity for high-current linacs, including Energy Recovery Linac (ERL) for planned electron-hadron collider eRHIC. The cavity will be fed by a high-power RF amplifier using a coaxial Fundamental Power Coupler (FPC), which delivers 20 kW of CW RF power to the cavity. The design of FPC is one of the important aspects as one has to take into account the heat losses dissipated on the surface of the conductor by RF fields along with that of the static heat load. Using a simple simulation model we show the temperature profile and the heat load dissipated along the coupler length. To minimize the heat load on FPC near the cavity end, a thermal intercept is required at an appropriate location on FPC. A 10 K intercept was chosen and its location optimized with our simulation code. The requirement on the helium gas flow rate for the effective heat removal from the thermal intercept is also discussed.

43 PARTICLE ACCELERATORS↗

Identification of Porphyrin-Silica Composite Nanoparticles using Atmospheric Solids Analysis Probe Mass Spectrometry

Porphyrins are critical pigments involved in biological energy transduction processes. Their abilities to absorb light, then convert it to energy, have raised the interest of using porphyrin nanoparticles as photosensitizers in photodynamic therapy. A current study showed that self- assembled porphyrin-silica composite nanoparticles can selectively destroy tumor cells, but detection of the cellular uptake of porphyrin-silica composite nanoparticles was limited to imaging microscopy. In this work, we developed a novel method to rapidly identify porphyrin-silica composite nanoparticles using Atmospheric Solids Analysis Probe-Mass Spectrometry (ASAP-MS). ASAP-MS can directly analyze complex mixtures without the need for sample preparation. Porphyrin-silica composite nanoparticles were vaporized using heated nitrogen desolvation gas, and their thermo-profiles were examined to identify distinct mass- to-charge (M/Z) signatures. HeLa cells were incubated in growth media containing the nanoparticles, and after sufficient washing to remove residual nanoparticles, the cell suspension was loaded onto the end of ASAP glass capillary probe. Upon heating, HeLa cells were degraded and porphyrin-silica composite nanoparticles were released. Vaporized nanoparticles were ionized and detected by MS. Furthermore, the cellular uptake of porphyrin-silica composite nanoparticles was identified using this ASAP-MS method.

36 MATERIALS SCIENCE↗

The Effect of Trailing Edge Grid Resolution in Large-Eddy Simulations

Ceramic Matrix Composite (CMC) with environmental barrier coating can tolerate significantly higher temperatures compared with the conventional metal alloy blades and thus can help achieve higher thermal efficiency in gas turbine engines. Due to the complex fabrication process of CMC blades, larger blade trailing edge thicknesses and larger leading-edge radii of curvature are expected. These features significantly alter aerodynamic performance especially near the trailing edge and thus the loss profile. In previous studies, the authors used the large eddy simulation (LES) as well as the Reynolds Averaged Navier-Stokes (RANS) coupled with an intermittency function-based transition model to simulate an aerodynamics performance of three different CMC blades and compared the predictions against the data acquired at NASA Glenn Transonic Turbine Blade Cascade Rig. Although we were able to successfully predict different characteristics of aerodynamic performance among three different blades (e.g., pressure loading and integrated losses), LES consistently predicted a small recirculation bubble at the end of the suction side. This was not inconsistent with the physics of the flow, but the pressure loading, locally, near the trailing edge, and as a result, the measured wake profiles did not match the experimental data. To delve further into these issues, a new LES grid with a much finer mesh near the trailing edge was generated where the spanwise extent of the grid was increased by 50%. An LES simulation for the CMC blade with the largest trailing edge thicknesses at the high-freestream turbulence (Tu=13%) condition showed that using such a mesh is necessary for LES to accurately capture the transition phenomena on the suction side. The resulting total pressure coefficient profile and the shift of the wake profile were greatly improved.

CMC↗

The Effect of Trailing Edge Grid Resolution in Large-Eddy Simulations

Ceramic Matrix Composite (CMC) with environmental barrier coating can tolerate significantly higher temperatures compared with the conventional metal alloy blades and thus can help achieve higher thermal efficiency in gas turbine engines. Due to the complex fabrication process of CMC blades, larger blade trailing edge thicknesses and larger leading-edge radii of curvature are expected. These features significantly alter aerodynamic performance especially near the trailing edge and thus the loss profile. In previous studies, the authors used the large eddy simulation (LES) as well as the Reynolds Averaged Navier-Stokes (RANS) coupled with an intermittency function-based transition model to simulate an aerodynamics performance of three different CMC blades and compared the predictions against the data acquired at NASA Glenn Transonic Turbine Blade Cascade Rig. Although we were able to successfully predict different characteristics of aerodynamic performance among three different blades (e.g., pressure loading and integrated losses), LES consistently predicted a small recirculation bubble at the end of the suction side. This was not inconsistent with the physics of the flow, but the pressure loading, locally, near the trailing edge, and as a result, the measured wake profiles did not match the experimental data. To delve further into these issues, a new LES grid with a much finer mesh near the trailing edge was generated where the spanwise extent of the grid was increased by 50%. An LES simulation for the CMC blade with the largest trailing edge thicknesses at the high-freestream turbulence (Tu=13%) condition showed that using such a mesh is necessary for LES to accurately capture the transition phenomena on the suction side. The resulting total pressure coefficient profile and the shift of the wake profile were greatly improved.

LES↗

Studying the Impact of Distributed Solar PV on Power Systems using Integrated Transmission and Distribution Models: Preprint

This paper presents the results of a distributed solar PV impact assessment study that was performed using a synthetic integrated transmission (T) and distribution (D) model. The primary objective of the study was to present a new approach for distributed solar PV impact assessment, where along with detailed models of transmission and distribution networks, consumer loads were modeled using the physics of end-use equipment, and distributed solar PV was geographically dispersed and connected to the secondary distribution networks. The highlights of the study results were (i) increase in the Area Control Error (ACE) at high penetration levels of distributed solar PV; and (ii) differences in distribution voltages profiles and voltage regulator operations between integrated T&D and distribution only simulations.

14 SOLAR ENERGY↗

Solar plus: A review of the end-user economics of solar PV integration with storage and load control in residential buildings

Batteries and load control devices can increase the value of distributed solar photovoltaics (PV) from multiple perspectives - end-user, utility, and social. This review paper summarizes the end-user economics of battery and load control technologies that increase the value of PV by controlling and temporally shifting PV output, an approach referred to as 'solar plus.' Solar plus can increase on-site PV use. The literature shows that these values justify the incremental costs of solar plus devices for a wide variety of technologies, geographies, and customer load profiles, especially for customers in three rate structure contexts: where PV is sold to the grid at a lower value than the customer's retail rate, in time-of-use rates where peak periods do not coincide with PV output, and in demand charge rates where load peaks do not coincide with PV output. Rate structure and policy reform may be necessary to ensure that increasing solar plus deployment provides both end-user and system-level benefits.

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Dispatch Schedule Generation for Demand Flexibility Measures

This supplemental document describes the methodology used for determining the dispatch timing of various EUSS demand flexibility measures. Demand flexibility measures are designed to reduce/dispatch electricity demand in buildings during especially beneficial/critical times. The method used in this work utilizes predictions of building loads to generate a schedule that reflects the periods when the building's daily peak load occurs to support decision making in demand flexibility measures. The dispatch schedule generation method described in this document creates an hourly schedule that includes a load dispatch (peak) window for each day for a whole year based on load prediction, with options using different prediction methods: perfect prediction, bin-sampling method, fixed schedule, and outdoor air temperature (OAT)-based prediction method. The perfect prediction method performs a simulation to obtain the annual load profile as predicted load, representing the scenario of perfect load prediction. The bin-sampling method (1) categorizes days into representative bins by temperature characteristics, (2) performs simulations on sample days from each of those bins to create representative (or predicted) load, and (3) assigns representative loads for all days in a year based on the bin categorization. The fixed schedule method defines uniform start and end time of peak window with assumed fixed daily peak time, for all days in a season or a year. The OAT-based prediction method uses the statistics of OAT (minimum and maximum) as the indicators of peak load, with specified delay response time from building loads to temperature. Given the load prediction, daily peak periods are determined as a time window with specified length in each day that include the predicted daily peak load and with a secondary rule such as maximizing energy saving potential. The dispatch schedule generation method is not a standalone measure and is intended to be combined with other demand flexibility measures that could leverage the peak schedule and apply demand controls on specific systems or devices for demand response, such as measures described in "Measure Documentation - Thermostat Control for Load Shedding" and "Measure Documentation - Thermostat Control for Load Shifting".

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Data-Driven Democratized Control Architecture for Regional Transmission Operators

As probably the most complicated and critical infrastructure system, U.S. power grids become increasingly vulnerable to extreme events such as cyber-attacks and severe weather, as well as higher DER penetrations and growing information mismatch among system operators, utilities (transmission or generation owners), and end-users. This paper proposes a data-driven democratized control architecture considering two democratization pathways to assist transmission system operators, with a targeted use case of developing online proactive islanding strategies. Detailed discussions on load capability profiling at transmission buses and disaggregation of DER generations are provided and illustrated with real-world utility data. By Combining network and operational constraints, transmission system operators can be equipped with new tools built on top of this architecture, to derive accurate, proactive, and strategic islanding decisions to incorporate the wide range of dynamic portfolios and needs when facing extreme events or unseen grid contingencies.

Power System Reliability, Islanding, Democratized ↗

Data-driven method for electric vehicle charging demand analysis: Case study in Virginia

Electric vehicle (EV) adoption in the U.S. will be accelerated by the historic $7.5 billion public investments in EV charging infrastructure. Careful analysis of EV charging demands plays a vital role in understanding the energy requirements, power grid impact, and smart charging management opportunities of EVs. To this end, this paper develops a data-driven trip-chaining-based modeling framework including five steps: Trip data acquisition and preprocessing, EV adoption modeling, travel itinerary synthesis, EV charging demand simulation and EV load profile generation. The developed analysis framework was demonstrated using real-world data for one region in Virginia, U.S. The results show that the proposed modeling framework can work effectively. For the study region in 2040, the predicted number of plug-in EVs is 470,114, resulting in a weekly charging demand of 38,078,127 kWh (55% home, 9% work, and 36% public) in September and 45,920,358 kWh (61% home, 9% work, and 30% public) in February.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stochastic simulation of occupant-driven energy use in a bottom-up residential building stock model

The residential buildings sector is one of the largest electricity consumers worldwide and contributes disproportionally to peak electricity demand in many regions. Strongly driven by occupant activities, household energy consumption is stochastic and heterogeneous in nature. However, most residential energy models applied by industry use homogeneous, deterministic activity schedules, which work well for predictions of annual energy consumption, but can result in unrealistic hourly or sub-hourly electric load profiles, with exaggerated or muted peaks. The increasing proportion of variable renewable energy generators means that representing the heterogeneity and stochasticity of occupant behavior is now crucial for reliable planning at both bulk-power and distribution-system scales. This work presents a novel and open-source occupancy simulation approach that can simulate a diverse set of individual occupant and household event schedules for all major electricity, fuel, and hot water end uses. To accomplish this, we evaluated three alternative occupant activity simulation approaches before selecting a hybrid combining time-inhomogeneous Markov chains and probability-sampling of event durations and magnitudes. Further, we integrated the stochastic occupancy simulation with an open-source bottom-up physics-simulation building stock model and published a set of 550,000 diverse household end-use activity schedules representing a national housing stock. The simulator was verified against time-use survey data, and simulation results were validated against measured end-use electricity data for accuracy and reliability. While we use data for the United States, our application demonstrates how similar approaches could be applied using the time-use survey data collected in many countries around the world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of high-fidelity ion cyclotron range of frequencies antenna coupling simulations in full 3D geometry against experiments in the ASDEX Upgrade tokamak

We address the validation of finite elements ion cyclotron range of frequencies (ICRF) antenna coupling simulation against experiments performed in the ASDEX Upgrade tokamak. Measurements of the loading resistance in ICRF-heated, magnetically-perturbed 3D plasma discharges are compared against numerical predictions of the RAPLICASOL code. To this end, the 3D induction field and the 3D density profile are modeled by concatenating the PARVMEC, BMW and EMC3-EIRENE codes. The 3D density is input to RAPLICASOL, where full-wave simulations are performed on a finite element mesh retaining full 3D geometry in the ICRF antenna model and the plasma description. The results are further compared with RAPLICASOL simulations using a 1D density profile as measured at the outboard midplane in the same experiments. We find that simulations using a 1D density profile overestimate the change in loading resistance by a factor of ~197 -248%, while simulations using the full 3D density profile are in agreement with experiments within a factor ~16%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring and Understanding the Energy Use Signatures of a Bank Building

The Pacific Northwest National Laboratory measured and analyzed the energy end-use patterns in a bank building located in the north-eastern United States. This work was performed in collaboration with PNC Financial Service Group under the US DOE’s Commercial Building Partnerships Program. This paper presents the metering study and the results of the metered data analysis. It provides a benchmark for the energy use of different bank-related equipments. The paper also reveals the importance of metering in fully understanding building loads and indentifying opportunities for energy efficiency improvements that will have impacts across PNC’s portfolio of buildings and were crucial to reducing receptacle loads in the design of a net-zero bank branches. PNNL worked with PNC to meter a 4,000 ft2 bank branch in the state of Pennsylvania. 71 electrical circuits were monitored and 25 stand-alone watt-hour meters were installed at the bank. These meters monitored the consumption of all interior and exterior lighting, receptacle loads, service water heating, and the HVAC rooftop unit at a 5-minute sampling interval from November 2009 to November 2010. A total of over 8 million data records were generated, which were then analyzed to produce the end-use patterns, daily usage profiles, rooftop unit usage cycles, and inputs for calibrating the energy model of the building.

ASHRAE↗