Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electron Target Cooling Analyses of the KIPT ADS Using MCNP and Ansys Fluent

This study presents multiphysics analyses of the electron target cooling system of the accelerator-driven system (ADS) of the Kharkiv Institute of Physics and Technology (KIPT) using MCNP and Fluent computer programs. MCNP has been used to transport electrons, gammas, and neutrons, and to calculate the energy deposition in the target materials. The MCNP mesh-tally data have been imported into Fluent by a C subroutine that has been compiled and linked to Fluent as a user-defined function.The KIPT ADS is located in Ukraine and was in operation until February 2022. The Fluent model is based on the computer-aided design files from the manufacturing process of the target assembly. Here, the Fluent results for the reference case match very well the literature results obtained by STAR-CCM+ during the design phase. Other cases that differ from the reference one have been analyzed; in these cases, it is assumed a malfunction of the electron accelerator or of the water cooling system. The target cooling system operates normally for all the analyzed cases except when the inlet water mass flow rate is decreased. The transient analysis showed that the target cooling system can operate for 180 s with full power when the inlet water mass flow rate is decreased down by 75%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of a Microbunched Electron Cooler Energy Recovery Linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55 MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1 nC, an average current of 100 mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Accelerator Physics↗

Design of a microbunched electron cooler energy recovery linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55 MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1 nC, an average current of 100 mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Accelerator Physics↗

Design of a Microbunched Electron Cooler Energy Recovery Linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55\,MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1\,nC, an average current of 100\,mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Deitrick, K. [Thomas Jefferson National Accelerato↗

DESIGN AND OPTIMIZATION OF AN ERL FOR COOLING EIC HADRON BEAMS

The baseline scheme for hadron beam cooling in the Electron Ion Collider (EIC) calls for Coherent electron Cooling (CeC) of the hadrons with non-magnetized electrons at high energy (150 MeV electrons) and additional cooling via conventional bunched beam cooling using a precooler system. The electron beam parameters for these concepts are at or beyond the current state of the art, with electron bunch charges on the order of 1 nC and average currents on the order of 100 mA and requiring an Energy Recovery Linac (ERL) to produce such beams. Using specifications provided by BNL and JLab, physicists and engineers at Xelera Research are working on a complete design of an ERL system capable of cooling EIC hadrons.

Gulliford, C.↗

An ultrafast laser pulse picker technique for high-average-current high-brightness photoinjectors

Beam diagnostics in high brightness photoinjectors requires that optical pulses from a high-power drive laser be picked up with an ultrahigh pulse contrast ratio and without temporal profile distortion. In high-average-current high-brightness photoinjectors, high-power drive lasers are routinely operated at GHz-level pulse repetition rate and it is challenging to achieve pulse picking without any pulse distortion. Here, we report on a new ultrafast pulse picker technique for beam diagnostics in high-average-current high-brightness photoinjectors. By efficiently combining an ultrafast low-power electro-optic modulator, high-power fiber laser amplifiers, a high-power Pockels Cell, and a frequency doubling module, we have successfully demonstrated optical bunch (30 pulses per bunch) pickup from a 704 MHz high-power drive laser and achieved a 10 6 :1 pulse contrast ratio and nearly zero pulse distortion. The performance of this pulse picking technique has been verified through beam characterization and electron cooling in the low energy RHIC electron cooling accelerator at Brookhaven National Laboratory.

43 PARTICLE ACCELERATORS↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Numerical modeling of a proof-of-principle experiment on optical stochastic cooling at an electron storage ring

Cooling of beams circulating in storage rings is critical for many applications including particle colliders and synchrotron light sources. A method enabling unprecedented beam-cooling rates, optical stochastic cooling (OSC), was recently demonstrated in the Integrable Optics Test Accelerator (IOTA) electron storage ring at Fermilab [J. Jarvis , ]. This paper describes the numerical implementation of the OSC process in the particle-tracking program and discusses the validation of the developed model with available experimental data. The model is also employed to highlight some features associated with different modes of operation of OSC. The developed simulation tool should be valuable in guiding future configurations of optical stochastic cooling and, more broadly, modeling self-field-based beam manipulations. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Intrinsically Slow Cooling of Hot Electrons in CdSe Nanocrystals Compared to CdS

The utilization of excited charge carriers in semiconductor nanocrystals (NCs) for optoelectronic technologies has been a long-standing goal in the field of nanoscience. Experimental efforts to extend the lifetime of excited carriers have therefore been a principal focus. To understand the limits of these lifetimes, in this work, we theoretically study the time scales of pure electron relaxation in negatively charged NCs composed of two prototypical materials: CdSe and CdS. We find that hot electrons in CdSe have lifetimes that are 5 to 6 orders of magnitude longer than in CdS when the relaxation is governed only by the intrinsic properties of the materials. Although these two materials are known to have somewhat different electronic structure, we elucidate how this enormous difference in lifetimes arises from relatively small quantitative differences in electronic energy gaps and phonon frequencies, as well as the crucial role of Fröhlich-type electron–phonon couplings.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Flow boiling in geometrically modified microchannels

Microchannels are a promising solution for high-heat-flux thermal management scenarios, including high-performance microelectronics cooling and power electronics cooling. However, thermohydraulic instabilities result from the rapid vapor bubble formation. The prior literature has examined several methods, including constricted inlet microchannels, expanding microchannels, and auxiliary jetting microchannels, to mitigate the effect of these instabilities. Computational fluid dynamics and heat transfer (CFD/HT) modeling of the flow boiling phenomena in these microchannel configurations has seen limited examination, and one-to-one numerical comparisons of the different mitigation strategies have not been performed. In the present investigation, CFD/HT analyses using a three-dimensional (3D) volume of fluid model coupled with a phase-change model for the interfacial heat and mass transfer were performed for multiple microchannel configurations (constricted inlet, expanding, and auxiliary jetting microchannels). A benchmark case of a rectangular microchannel was examined to quantify baseline thermohydraulic performance. Results demonstrated slight to significant thermal performance improvements for all cases, and significant pressure benefits for the expanding and jetting cases, consistent with experimental results in the literature. Bubble dynamics and visualization for the baseline and alternative configurations are provided to give insight into their underlying physics, and the differences in performance were investigated and compared with available literature.

Broughton, Justin (ORCID:000000026848457X)↗

Summary of the CeC Experiment in RHIC Run 21

The coherent electron cooling (CeC) experiment at RHIC is crucial for determining the feasibility of this technique for cooling the hadron beam in the electron-ion collider (EIC) and reaching the luminosity of 10 34 cm -1 s -1 . During RHIC Run 21, various progresses have been made including successfully commissioning the time resolved diagnostic beam line (TRDBL), achieving the key performance parameters (KPP) of the system and the development of novel methods for accurate alignment of the electron beam with the ion beam. While the longitudinal cooling of the ion beam with cooling time of 100 hours was observed during Run 21, it was related to the traditional electron cooling since the cooling rate was not as sensitive to the energy of the electron beam as what one would expect from the CeC. In Run 21, we were not able to observe the longitudinal cooling of the ion beam caused by CeC and the main challenges are identified as the insufficient stability of the electrons' energy. The sources of the energy jitter have been identified and we are making improvements to the stability of the CeC system for Run 22.

43 PARTICLE ACCELERATORS↗

Experimental Demonstration of Hadron Beam Cooling Using Radio-Frequency Accelerated Electron Bunches

Cooling of beams of gold ions using electron bunches accelerated with radio-frequency systems was recently experimentally demonstrated in the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. Such an approach is new and opens the possibility of using this technique at higher energies than possible with electrostatic acceleration of electron beams. The challenges of this approach include generation of electron beams suitable for cooling, delivery of electron bunches of the required quality to the cooling sections without degradation of beam angular divergence and energy spread, achieving the required small angles between electron and ion trajectories in the cooling sections, precise velocity matching between the two beams, high-current operation of the electron accelerator, as well as several physics effects related to bunched-beam cooling. Here we report on the first demonstration of cooling hadron beams using this new approach.

43 PARTICLE ACCELERATORS↗

Screening of hot electrons in the ferroelectric semiconductor In 2 Se 3

We report that in a conventional semiconductor, electrons (e) scatter efficiently with longitudinal-optical phonons (ph LO ) via the Fröhlich interaction, e.g., in polaron formation or hot-electron cooling. Recent studies on lead halide perovskites have suggested that the Fröhlich interaction may be sufficiently screened by the polar lattice. Here we show that hot-electron cooling in a layered ferroelectric semiconductor In 2 Se 3 slows down by 50% as temperature is increased from 115 to 387 K; this decrease is about four times more than that predicted by the Fröhlich model. We suggest that screening of Fröhlich interaction by polar domains or fluctuations in the ferroelectric semiconductor may be responsible for the reduced e-ph LO scattering. Such enhanced screening in polar materials featuring anharmonic lattice instability may also reduce carrier scattering with other charge carriers or with charged defects, leading to improved optoelectronic properties.

36 MATERIALS SCIENCE↗

3D Theoretical and simulation tools for microbunched cooling

The concept of microbunched electron cooling (MBEC, introduced in Ref. [1]) is currently under investigation as a candidate for the strong hadron cooling (SHC) component of EIC. Most of the theoretical treatments of this scheme are based on a simplified model for the longitudinal space charge [2–4]. In this model, the particle beams are treated as collections of thin charged disks, with the interaction function for two such disks being calculated by averaging the forces between constituent point charges. Although the disk model is flexible and captures a large part of the underlying physics, it lacks the fidelity and robustness of an analysis that explicitly treats the beams as collections of point charges. In what follows, we explore such a model, both from a theory-based and a simulation perspective.

43 PARTICLE ACCELERATORS↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dispersion effect on the cooling rates

It is known that dispersion can redistribute the electron cooling rate between longitudinal and transverse planes. This note presents a simple analytical model to explain and estimate this redistribution effect. It shows that a small horizontal dispersion on ions can enhance horizontal cooling at the expense of longitudinal cooling rate. The electron dispersion is also beneficial to this effect.

43 PARTICLE ACCELERATORS↗