Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrocardiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fractal correlation properties of R-R interval dynamics and mortality in patients with depressed left ventricular function after an acute myocardial infarction

BACKGROUND: Preliminary data suggest that the analysis of R-R interval variability by fractal analysis methods may provide clinically useful information on patients with heart failure. The purpose of this study was to compare the prognostic power of new fractal and traditional measures of R-R interval variability as predictors of death after acute myocardial infarction. METHODS AND RESULTS: Time and frequency domain heart rate (HR) variability measures, along with short- and long-term correlation (fractal) properties of R-R intervals (exponents alpha(1) and alpha(2)) and power-law scaling of the power spectra (exponent beta), were assessed from 24-hour Holter recordings in 446 survivors of acute myocardial infarction with a depressed left ventricular function (ejection fraction </=35%). During a mean+/-SD follow-up period of 685+/-360 days, 114 patients died (25.6%), with 75 deaths classified as arrhythmic (17.0%) and 28 as nonarrhythmic (6.3%) cardiac deaths. Several traditional and fractal measures of R-R interval variability were significant univariate predictors of all-cause mortality. Reduced short-term scaling exponent alpha(1) was the most powerful R-R interval variability measure as a predictor of all-cause mortality (alpha(1) <0.75, relative risk 3.0, 95% confidence interval 2.5 to 4.2, P<0.001). It remained an independent predictor of death (P<0.001) after adjustment for other postinfarction risk markers, such as age, ejection fraction, NYHA class, and medication. Reduced alpha(1) predicted both arrhythmic death (P<0.001) and nonarrhythmic cardiac death (P<0.001). CONCLUSIONS: Analysis of the fractal characteristics of short-term R-R interval dynamics yields more powerful prognostic information than the traditional measures of HR variability among patients with depressed left ventricular function after an acute myocardial infarction.

Non-NASA Center↗

Analysis of the ST-T complex of the electrocardiogram using the Karhunen--Loeve transform: adaptive monitoring and alternans detection

The Karhunen-Loeve transform (KLT) is applied to study the ventricular repolarisation period as reflected in the ST-T complex of the surface ECG. The KLT coefficients provide a sensitive means of quantitating ST-T shapes. A training set of ST-T complexes is used to derive a set of KLT basis vectors that permits representation of 90% of the signal energy using four KLT coefficients. As a truncated KLT expansion tends to favor representation of the signal over any additive noise, a time series of KLT coefficients obtained from successive ST-T complexes is better suited for representation of both medium-term variations (such as ischemic changes) and short-term variations (such as ST-T alternans) than discrete parameters such as the ST level or other local indices. For analysis of ischemic changes, an adaptive filter is described that can be used to estimate the KLT coefficient, yielding an increase in the signal-to-noise ratio of 10 dB (u = 0.1), with a convergence time of about three beats. A beat spectrum of the unfiltered KLT coefficient series is used for detection of ST-T alterans. These methods are illustrated with examples from the European ST-T Database. About 20% of records revealed quasi-periodic salvos of ischemic ST-T change episodes and another 20% exhibit repetitive, but not clearly periodic patterns of ST-T change episodes. About 5% of ischemic episodes were associated with ST-T alterans.

NASA Discipline Cardiopulmonary↗

Sympathetic adaptations to one-legged training

The purpose of the present study was to determine the effect of leg exercise training on sympathetic nerve responses at rest and during dynamic exercise. Six men were trained by using high-intensity interval and prolonged continuous one-legged cycling 4 day/wk, 40 min/day, for 6 wk. Heart rate, mean arterial pressure (MAP), and muscle sympathetic nerve activity (MSNA; peroneal nerve) were measured during 3 min of upright dynamic one-legged knee extensions at 40 W before and after training. After training, peak oxygen uptake in the trained leg increased 19 +/- 2% (P < 0.01). At rest, heart rate decreased from 77 +/- 3 to 71 +/- 6 beats/min (P < 0.01) with no significant changes in MAP (91 +/- 7 to 91 +/- 11 mmHg) and MSNA (29 +/- 3 to 28 +/- 1 bursts/min). During exercise, both heart rate and MAP were lower after training (108 +/- 5 to 96 +/- 5 beats/min and 132 +/- 8 to 119 +/- 4 mmHg, respectively, during the third minute of exercise; P < 0.01). MSNA decreased similarly from rest during the first 2 min of exercise both before and after training. However, MSNA was significantly less during the third minute of exercise after training (32 +/- 2 to 22 +/- 3 bursts/min; P < 0.01). This training effect on MSNA remained when MSNA was expressed as bursts per 100 heartbeats. Responses to exercise in five untrained control subjects were not different at 0 and 6 wk. These results demonstrate that exercise training prolongs the decrease in MSNA during upright leg exercise and indicates that attenuation of MSNA to exercise reported with forearm training also occurs with leg training.

Non-NASA Center↗

Heart rate dynamics before spontaneous onset of ventricular fibrillation in patients with healed myocardial infarcts

The traditional methods of analyzing heart rate (HR) variability have failed to predict imminent ventricular fibrillation (VF). We sought to determine whether new methods of analyzing RR interval variability based on nonlinear dynamics and fractal analysis may help to detect subtle abnormalities in RR interval behavior before the onset of life-threatening arrhythmias. RR interval dynamics were analyzed from 24-hour Holter recordings of 15 patients who experienced VF during electrocardiographic recording. Thirty patients without spontaneous or inducible arrhythmia events served as a control group in this retrospective case control study. Conventional time- and frequency-domain measurements, the short-term fractal scaling exponent (alpha) obtained by detrended fluctuation analysis, and the slope (beta) of the power-law regression line (log power - log frequency, 10(-4)-10(-2) Hz) of RR interval dynamics were determined. The short-term correlation exponent alpha of RR intervals (0.64 +/- 0.19 vs 1.05 +/- 0.12; p <0.001) and the power-law slope beta (-1.63 +/- 0.28 vs -1.31 +/- 0.20, p <0.001) were lower in the patients before the onset of VF than in the control patients, but the SD and the low-frequency spectral components of RR intervals did not differ between the groups. The short-term scaling exponent performed better than any other measurement of HR variability in differentiating between the patients with VF and controls. Altered fractal correlation properties of HR behavior precede the spontaneous onset of VF. Dynamic analysis methods of analyzing RR intervals may help to identify abnormalities in HR behavior before VF.

Non-NASA Center↗

Fractal analysis of heart rate dynamics as a predictor of mortality in patients with depressed left ventricular function after acute myocardial infarction. TRACE Investigators. TRAndolapril Cardiac Evaluation

A number of new methods have been recently developed to quantify complex heart rate (HR) dynamics based on nonlinear and fractal analysis, but their value in risk stratification has not been evaluated. This study was designed to determine whether selected new dynamic analysis methods of HR variability predict mortality in patients with depressed left ventricular (LV) function after acute myocardial infarction (AMI). Traditional time- and frequency-domain HR variability indexes along with short-term fractal-like correlation properties of RR intervals (exponent alpha) and power-law scaling (exponent beta) were studied in 159 patients with depressed LV function (ejection fraction <35%) after an AMI. By the end of 4-year follow-up, 72 patients (45%) had died and 87 (55%) were still alive. Short-term scaling exponent alpha (1.07 +/- 0.26 vs 0.90 +/- 0.26, p <0.001) and power-law slope beta (-1.35 +/- 0.23 vs -1.44 +/- 0.25, p <0.05) differed between survivors and those who died, but none of the traditional HR variability measures differed between these groups. Among all analyzed variables, reduced scaling exponent alpha (<0.85) was the best univariable predictor of mortality (relative risk 3.17, 95% confidence interval 1.96 to 5.15, p <0.0001), with positive and negative predictive accuracies of 65% and 86%, respectively. In the multivariable Cox proportional hazards analysis, mortality was independently predicted by the reduced exponent alpha (p <0.001) after adjustment for several clinical variables and LV function. A short-term fractal-like scaling exponent was the most powerful HR variability index in predicting mortality in patients with depressed LV function. Reduction in fractal correlation properties implies more random short-term HR dynamics in patients with increased risk of death after AMI.

Non-NASA Center↗

Abnormalities of the QT interval in primary disorders of autonomic failure

BACKGROUND: Experimental evidence shows that activation of the autonomic nervous system influences ventricular repolarization and, therefore, the QT interval on the ECG. To test the hypothesis that the QT interval is abnormal in autonomic dysfunction, we examined ECGs in patients with severe primary autonomic failure and in patients with congenital dopamine beta-hydroxylase (DbetaH) deficiency who are unable to synthesize norepinephrine and epinephrine. SUBJECTS AND METHODS: Maximal QT and rate-corrected QT (QTc) intervals and adjusted QTc dispersion [(maximal QTc - minimum QTc on 12 lead ECG)/square root of the number of leads measured] were determined in blinded fashion from ECGs of 67 patients with primary autonomic failure (36 patients with multiple system atrophy [MSA], and 31 patients with pure autonomic failure [PAF]) and 17 age- and sex-matched healthy controls. ECGs of 5 patients with congenital DbetaH deficiency and 6 age- and sex-matched controls were also analyzed. RESULTS: Patients with MSA and PAF had significantly prolonged maximum QTc intervals (492+/-58 ms(1/2) and 502+/-61 ms(1/2) [mean +/- SD]), respectively, compared with controls (450+/-18 ms(1/2), P < .05 and P < .01, respectively). A similar but not significant trend was observed for QT. QTc dispersion was also increased in MSA (40+/-20 ms(1/2), P < .05 vs controls) and PAF patients (32+/-19 ms(1/2), NS) compared with controls (21+/-5 ms(1/2)). In contrast, patients with congenital DbetaH deficiency did not have significantly different RR, QT, QTc intervals, or QTc dispersion when compared with controls. CONCLUSIONS: Patients with primary autonomic failure who have combined parasympathetic and sympathetic failure have abnormally prolonged QT interval and increased QT dispersion. However, QT interval in patients with congenital DbetaH deficiency was not significantly different from controls. It is possible, therefore, that QT abnormalities in patients with primary autonomic failure are not solely caused by lesions of the sympathetic nervous system, and that the parasympathetic nervous system is likely to have a modulatory role in ventricular repolarization.

Non-NASA Center↗

Mechanisms underlying very-low-frequency RR-interval oscillations in humans

BACKGROUND: Survival of post-myocardial infarction patients is related inversely to their levels of very-low-frequency (0.003 to 0.03 Hz) RR-interval variability. The physiological basis for such oscillations is unclear. In our study, we used blocking drugs to evaluate potential contributions of sympathetic and vagal mechanisms and the renin-angiotensin-aldosterone system to very-low-frequency RR-interval variability in 10 young healthy subjects. METHODS AND RESULTS: We recorded RR intervals and arterial pressures during three separate sessions, with the patient in supine and 40 degree upright tilt positions, during 20-minute frequency (0.25 Hz) and tidal volume-controlled breathing after intravenous injections: saline (control), atenolol (0.2 mg/kg, beta-adrenergic blockade), atropine sulfate (0.04 mg/kg, parasympathetic blockade), atenolol and atropine (complete autonomic blockade), and enalaprilat (0.02 mg/kg, ACE blockade). We integrated fast Fourier transform RR-interval spectral power at very low (0.003 to 0.03 Hz), low (0.05 to 0. 15 Hz), and respiratory (0.2 to 0.3 Hz) frequencies. Beta-adrenergic blockade had no significant effect on very-low- or low-frequency RR-interval power but increased respiratory frequency power 2-fold. ACE blockade had no significant effect on low or respiratory frequency RR-interval power but modestly (approximately 21%) increased very-low-frequency power in the supine (but not upright tilt) position (P<0.05). The most profound effects were exerted by parasympathetic blockade: Atropine, given alone or with atenolol, abolished nearly all RR-interval variability and decreased very-low-frequency variability by 92%. CONCLUSIONS: Although very-low-frequency heart period rhythms are influenced by the renin-angiotensin-aldosterone system, as low and respiratory frequency RR-interval rhythms, they depend primarily on the presence of parasympathetic outflow. Therefore the prognostic value of very-low-frequency heart period oscillations may derive from the fundamental importance of parasympathetic mechanisms in cardiovascular health.

Non-NASA Center↗

Diagnostic yield and optimal duration of continuous-loop event monitoring for the diagnosis of palpitations. A cost-effectiveness analysis

BACKGROUND: Continuous-loop event recorders are widely used for the evaluation of palpitations, but the optimal duration of monitoring is unknown. OBJECTIVE: To determine the yield, timing, and incremental cost-effectiveness of each week of event monitoring for palpitations. DESIGN: Prospective cohort study. PATIENTS: 105 consecutive outpatients referred for the placement of a continuous-loop event recorder for the evaluation of palpitations. MEASUREMENTS: Diagnostic yield, incremental cost, and cost-effectiveness for each week of monitoring. RESULTS: The diagnostic yield of continuous-loop event recorders was 1.04 diagnoses per patient in week 1, 0.15 diagnoses per patient in week 2, and 0.01 diagnoses per patient in week 3 and beyond. Over time, the cost-effectiveness ratio increased from $98 per new diagnosis in week 1 to $576 per new diagnosis in week 2 and $5832 per new diagnosis in week 3. CONCLUSIONS: In patients referred for evaluation of palpitations, the diagnostic yield of continuous-loop event recording decreases rapidly after 2 weeks of monitoring. A 2-week monitoring period is reasonably cost-effective for most patients and should be the standard period for continuous-loop event recording for the evaluation of palpitations.

NASA Discipline Cardiopulmonary↗

An episode of ventricular tachycardia during long-duration spaceflight

An episode of nonsustained ventricular tachycardia was recorded from a crew member during the second month aboard the MIR space station. Although asymptomatic, this cardiac event increases the concern that serious cardiac dysrhythmias may be a limiting factor during long-duration spaceflight.

NASA Center JSC↗

Contributions of tidal lung inflation to human R-R interval and arterial pressure fluctuations

We studied the effects of mechanical lung inflation on respiratory frequency R-R interval and arterial pressure fluctuations in nine healthy young adults undergoing elective orthopedic surgery. We conducted this research to define the contribution of pulmonary and thoracic stretch receptor input to respiratory sinus arrhythmia. We compared fast Fourier transform spectral power during three modes of ventilation: (1) spontaneous, frequency-controlled (0.25 Hz) breathing, (2) intermittent positive pressure ventilation (0.25 Hz, with a tidal volume of 8 ml/kg) and (3) high frequency jet ventilation (5.0 Hz, 2.5 kg/cm2), after sedation and vecuronium paralysis. Mean R-R intervals, arterial pressures and arterial blood gas levels were comparable during all three breathing conditions. Respiratory frequency systolic pressure spectral power was comparable during spontaneous breathing and conventional mechanical ventilation, but was significantly reduced during high frequency jet ventilation (P < 0.05). Respiratory frequency R-R interval spectral power (used as an index of respiratory sinus arrhythmia) declined dramatically with sedation and muscle paralysis (P < 0.05), but was greater during conventional mechanical, than high frequency jet ventilation (P < 0.05). These results suggest that although phasic inputs from pulmonary and thoracic stretch receptors make a statistically significant contribution to respiratory sinus arrhythmia, that contribution is small.

Clinical Trial↗

Controlled breathing protocols probe human autonomic cardiovascular rhythms

The purpose of this study was to determine how breathing protocols requiring varying degrees of control affect cardiovascular dynamics. We measured inspiratory volume, end-tidal CO2, R-R interval, and arterial pressure spectral power in 10 volunteers who followed the following 5 breathing protocols: 1) uncontrolled breathing for 5 min; 2) stepwise frequency breathing (at 0.3, 0.25, 0.2, 0.15, 0.1, and 0.05 Hz for 2 min each); 3) stepwise frequency breathing as above, but with prescribed tidal volumes; 4) random-frequency breathing (approximately 0.5-0.05 Hz) for 6 min; and 5) fixed-frequency breathing (0.25 Hz) for 5 min. During stepwise breathing, R-R interval and arterial pressure spectral power increased as breathing frequency decreased. Control of inspired volume reduced R-R interval spectral power during 0.1 Hz breathing (P < 0.05). Stepwise and random-breathing protocols yielded comparable coherence and transfer functions between respiration and R-R intervals and systolic pressure and R-R intervals. Random- and fixed-frequency breathing reduced end-tidal CO2 modestly (P < 0.05). Our data suggest that stringent tidal volume control attenuates low-frequency R-R interval oscillations and that fixed- and random-rate breathing may decrease CO2 chemoreceptor stimulation. We conclude that autonomic rhythms measured during different breathing protocols have much in common but that a stepwise protocol without stringent control of inspired volume may allow for the most efficient assessment of short-term respiratory-mediated autonomic oscillations.

Non-NASA Center↗

Nonlinear pattern analysis of ventricular premature beats by mutual information

The frequency of ventricular premature beats (VPBs) has been related to the risk of mortality. However, little is known about the temporal pattern of occurrence of VPBs and its relationship to autonomic activity. Hence, we applied a general correlation measure, mutual information, to quantify how VPBs are generated over time. We also used mutual information to determine the correlation between VPB production and heart rate in order to evaluate effects of autonomic activity on VPB production. We examined twenty subjects with more than 3000 VPBs/day and simulated random time series of VPB occurrence. We found that mutual information values could be used to characterize quantitatively the temporal patterns of VPB generation. Our data suggest that VPB production is not random and VPBs generated with a higher value of mutual information may be more greatly affected by autonomic activity.

NASA Discipline Regulatory Physiology↗

Effect of perturbations and a meal on superior mesenteric artery flow in patients with orthostatic hypotension

Our aims were to evaluate to role of superior mesenteric blood flow in the pathophysiology of orthostatic hypotension in patients with generalized autonomic failure. METHODS: Twelve patients with symptomatic neurogenic orthostatic hypotension and 12 healthy controls underwent superior mesenteric artery flow measurements using Doppler ultrasonography during head-up tilt and tilt plus meal ingestion. Autonomic failure was assessed using standard tests of the function of the sympathetic adrenergic, cardiovagal and postganglionic sympathetic sudomotor function. RESULTS: Superior mesenteric flow volume and time-averaged velocity were similar in patients and controls at supine rest; however, responses to cold pressor test and upright tilt were attenuated (p < 0.05) in patients compared to controls. Head-up tilt after the meal evoked a profound fall of blood pressure and mesenteric blood flow in the patients; the reduction of mesenteric blood flow correlated (r = 0.89) with the fall of blood pressure in these patients, providing another manifestation of failed baroreflexes. We make the novel finding that the severity of postprandial orthostatic hypotension regressed negatively with the postprandial increase in mesenteric flow in patients with orthostatic hypotension. CONCLUSION: Mesenteric flow is under baroreflex control, which when defective, results in, or worsens orthostatic hypotension. Its large size and baroreflexivity renders it quantitatively important in the maintenance of postural normotension. The effects of orthostatic stress can be significantly attenuated by reducing the splanchnic-mesenteric volume increase in response to food. Evaluation of mesenteric flow in response to eating and head-up tilt provide important information on intra-abdominal sympathetic adrenergic function, and the ability of the patient to cope with orthostatic stress.

Non-NASA Center↗

Human heart rate variability relation is unchanged during motion sickness

In a study of 18 human subjects, we applied a new technique, estimation of the transfer function between instantaneous lung volume (ILV) and instantaneous heart rate (HR), to assess autonomic activity during motion sickness. Two control recordings of ILV and electrocardiogram (ECG) were made prior to the development of motion sickness. During the first, subjects were seated motionless, and during the second they were seated rotating sinusoidally about an earth vertical axis. Subjects then wore prism goggles that reverse the left-right visual field and performed manual tasks until they developed moderate motion sickness. Finally, ILV and ECG were recorded while subjects maintained a relatively constant level of sickness by intermittent eye closure during rotation with the goggles. Based on analyses of ILV to HR transfer functions from the three conditions, we were unable to demonstrate a change in autonomic control of heart rate due to rotation alone or due to motion sickness. These findings do not support the notion that moderate motion sickness is manifested as a generalized autonomic response.

NASA Discipline Neuroscience↗

Electrical alternans during rest and exercise as predictors of vulnerability to ventricular arrhythmias

This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise protocol. Sensitive spectral signal-processing techniques are able to detect beat-to-beat alternation of the amplitude of the T wave, which is not visible on standard electrocardiogram. Previous animal and human investigations using atrial or ventricular pacing have demonstrated that T-wave alternans is a marker of vulnerability to ventricular arrhythmias. Using a spectral analysis technique incorporating noise reduction signal-processing software, we evaluated electrical alternans at rest and with the heart rate elevated during a bicycle exercise protocol. In this study we defined optimal criteria for electrical alternans to separate patients from those without inducible arrhythmias. Alternans and signal-averaged electrocardiographic results were compared with the results of vulnerability to ventricular arrhythmias as defined by induction of sustained ventricular tachycardia or fibrillation at electrophysiologic evaluation. In 27 patients alternans recorded at rest and with exercise had a sensitivity of 89%, specificity of 75%, and overall clinical accuracy of 80% (p <0.003). In this patient population the signal-averaged electrocardiogram was not a significant predictor of arrhythmia vulnerability. This is the first study to report that repolarization alternans can be detected with heart rate elevated with a bicycle exercise protocol. Alternans measured using this technique is an accurate predictor of arrhythmia inducibility.

Clinical Trial↗

Vagal and sympathetic mechanisms in patients with orthostatic vasovagal syncope

BACKGROUND: Autonomic and particularly sympathetic mechanisms play a central role in the pathophysiology of vasovagal syncope. We report direct measurements of muscle sympathetic nerve activity in patients with orthostatic vasovagal syncope. METHODS AND RESULTS: We studied 53 otherwise healthy patients with orthostatic syncope. We measured RR intervals and finger arterial pressures and in 15 patients, peroneal nerve muscle sympathetic activity before and during passive 60 degree head-up tilt, with low-dose intravenous isoproterenol if presyncope did not develop by 15 minutes. We measured baroreflex gain before tilt with regression of RR intervals or sympathetic bursts on systolic or diastolic pressures after sequential injections of nitroprusside and phenylephrine. Orthostatic vasovagal reactions occurred in 21 patients, including 7 microneurography patients. Presyncopal and nonsyncopal patients had similar baseline RR intervals, arterial pressure, and muscle sympathetic nerve activity. Vagal baroreflex responses were significantly impaired at arterial pressures below (but not above) baseline levels in presyncopal patients. Initial responses to tilt were comparable; however, during the final 200 seconds of tilt, presyncopal patients had lower RR intervals and diastolic pressures than nonsyncopal patients and gradual reduction of arterial pressure and sympathetic activity. Frank presyncope began abruptly with precipitous reduction of arterial pressure, disappearance of muscle sympathetic nerve activity, and RR interval lengthening. CONCLUSIONS: Patients with orthostatic vasovagal reactions have impaired vagal baroreflex responses to arterial pressure changes below resting levels but normal initial responses to upright tilt. Subtle vasovagal physiology begins before overt presyncope. The final trigger of human orthostatic vasovagal reactions appears to be the abrupt disappearance of muscle sympathetic nerve activity.

Non-NASA Center↗

Dynamic analysis of heart rate may predict subsequent ventricular tachycardia after myocardial infarction

Dynamics analysis of RR interval behavior and traditional measures of heart rate variability were compared between postinfarction patients with and without vulnerability to ventricular tachyarrhythmias in a case-control study. Short-term fractal correlation of heart rate dynamics was better than traditional measures of heart rate variability in differentiating patients with and without life-threatening arrhythmias.

NASA Discipline Cardiopulmonary↗