Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical conductivity of soil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electrical Resistivity Tomography Monitoring of In Situ Soil Flushing at the Hanford 100-K East Area: 100KE Soil Flushing Monitoring

Former operations in the 100-KE Area at the Hanford Site resulted in vadose zone hexavalent chromium that provides a source of groundwater contamination. Previous efforts to remediate vadose zone chromium involved excavation and offsite treatment of contaminated soils. Although much of the chromium was removed, contamination still exists in native soil between the water table and the bottom of the pit, which has since been backfilled. In-situ soil flushing was tested at the 100-KE Area to accelerate the removal of the remaining hexavalent chromium in the vadose zone. Soil flushing works by applying clean flush water at the surface, which mobilizes and transports chromium as it migrates downward to the water table. Once the chromium reaches the water table, it is hydraulically contained, extracted, and treated through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. Therefore, performance monitoring requires and understanding of flush water migration through the vadose zone. It is challenging to comprehensively assess soil flushing performance via borehole access due to the limited volume of investigation afforded by a given wellbore. As an alternative, 3D time-lapse electrical resistivity tomography (ERT) was tested as a method of monitoring the distribution of flush water over time within the vadose zone. ERT is a method of imaging the bulk electrical conductivity of the subsurface, which is highly dependent on water saturation levels in unconsolidated and unsaturated sediments. Thus, the timing and location of changes in bulk conductivity caused by soil flushing can be used to infer flush water migration pathways. In this report we present results of 3D time-lapse ERT imaging during two separate soil flushing campaigns conducted during the spring and summer months of 2022 and 2023. Results show generally that: 1) Pit backfill materials appear to nominally have larger permeability than native soils. Consequently, the boundary between pit backfill and native soil had a significant impact on flush water migration, causing some flush water to migrate along the pit boundary to the bottom of the pit. 2) Non-uniform flows, likely caused by variations in hydrogeologic properties, developed in the pit backfill materials, resulting in uneven flush water distribution on the southern margin of the soil flushing zone. 3) Redistribution of water at the interface between backfill materials and Hanford formation materials likely facilitated elevated and uniform distribution of flush water within native soils beneath the deeper parts of the pit boundary beneath the center of the flush zone, which presumably overlie soils with elevated chromium contamination. These areas appear to have been infiltrated by higher volumes of flush water than the northern and southern margins of the flush zone. 4) In comparison to 2022, high flush water application rates significantly improved flush water distribution throughout the target flushing zone. 5) Imaging resolution was limited to a depth of approximate 20 meters below the land surface, due primarily to limitations on the lateral extent of the surface ERT array. The ~10 m region of the vadose zone between approximately 130 meters elevation and the water table at approximately 120 meters elevation was unresolved.

100 Area↗

Request for Discontinuation of Long-Term Monitoring Orsino Storage Yard Solid Waste Management Unit 004 Kennedy Space Center, Florida

This report presents the site history, groundwater sampling results, and recommendations from the 2021 Industrial Area (IA) LTM activities at ORSY. ORSY has been used as a staging facility for electrical equipment since 1966 (EG&G 1991). Initial investigations conducted between 1986 and 1992 focused on polychlorinated biphenyls (PCBs) in soil. A series of soil excavation interim measures (IMs) were conducted to remove soils containing total PCB concentrations of greater than 25 milligrams per kilogram (mg/kg). A Resource Conservation and Recovery Act (RCRA) Facility Investigation (RFI) was completed in several phases at ORSY from 1998 through 2005, with PCBs in soil and volatile organic compounds (VOCs) in groundwater identified as contaminants of concern.

Jennifer Lynn Joyal↗

Induced Polarization of Clayey Rocks and Soils: Non‐Linear Complex Conductivity Models

Abstract The past decades have witnessed the increased applications of induced polarization (IP) method in the critical zone studies with ubiquitous clay minerals. Although IP outperforms traditional electrical and electromagnetic methods through its unique ability to measure quadrature conductivity, the nonlinearity that quadrature conductivity behaves with salinities and frequencies greatly tortures IP practitioners, as (a) salinity‐dependency makes the quadrature conductivity a varyingly unstable parameter to quantitatively estimate hydraulic properties and clay content; (b) frequency‐dependent Cole‐Cole and Debye/Warburg decomposition models, although mathematically sound, physically mingle the properties of pore water and clay minerals and are empirical in nature. From basic principles, we demonstrate that quadrature conductivity remains a hybrid property involving both clay and water, and develop relevant models to distinguish them. Our models are validated by theories, experiments, simulations, and comparisons, all of which proclaim considerable advantages over previous models and offer the prospect of quantitative applications.

58 GEOSCIENCES↗

Estimation of soil classes and their relationship to grapevine vigor in a Bordeaux vineyard: advancing the practical joint use of electromagnetic induction (EMI) and NDVI datasets for precision viticulture

Working within a vineyard in the Pessac Léognan Appellation of Bordeaux, France, this study documents the potential of using simple statistical methods with spatially-resolved and increasingly available electromagnetic induction (EMI) geophysical and normalized difference vegetation index (NDVI) datasets to accurately estimate Bordeaux vineyard soil classes and to quantitatively explore the relationship between vineyard soil types and grapevine vigor. First, co-located electrical tomographic tomography (ERT) and EMI datasets were compared to gain confidence about how the EMI method averaged soil properties over the grapevine rooting depth. Then, EMI data were used with core soil texture and soil-pit based interpretations of Bordeaux soil types (Brunisol, Redoxisol, Colluviosol and Calcosol) to estimate the spatial distribution of geophysically-identified Bordeaux soil classes. A strong relationship (r = 0.75, p < 0.01) was revealed between the geophysically-identified Bordeaux soil classes and NDVI (both 2 m resolution), showing that the highest grapevine vigor was associated with the Bordeaux soil classes having the largest clay fraction. The results suggest that within-block variability of grapevine vigor was largely controlled by variability in soil classes, and that carefully collected EMI and NDVI datasets can be exceedingly helpful for providing quantitative estimates of vineyard soil and vigor variability, as well as their covariation. The method is expected to be transferable to other viticultural regions, providing an approach to use easy-to-acquire, high resolution datasets to guide viticultural practices, including routine management and replanting.

54 ENVIRONMENTAL SCIENCES↗

A study of hear sink performance in air and soil for use in a thermoelectric energy harvesting device

A suggested application of a thermoelectric generator is to exploit the natural temperature difference between the air and the soil to generate small amounts of electrical energy. Since the conversion efficiency of even the best thermoelectric generators available is very low, the performance of the heat sinks providing the heat flow is critical. By providing a constant heat input to various heat sinks, field tests of their thermal conductances in soil and in air were performed. Aprototype device without a thermoelectric generator was constructed, buried, and monitored to experimentally measure the heat flow achievable in such a system. Theoretical considerations for design and selection of improved heat sinks are also presented. In particular, the method of shape factoranalysis is used to give rough estimates and upper bounds for the thermal conductance of a passive heat sink buried in soil.

Thermoelectric power generation↗

Lime slurry treatment of soils developing on abandoned coal mine spoil: Linking contaminant transport from the micrometer to pedon-scale

Historical and abandoned coal mine spoil continues to generate acid- and metal(loid)-rich porewaters and represents a geographically large and diffuse non-point source of contamination to local watersheds. A potentially inexpensive approach to treat these materials and soils developing on them is through the application of lime slurries, to neutralize acidity and encourage the (co)precipitation of metal(loids) with Fe(III)-(oxy)hydroxides, and potentially other metal-oxides and/or Ca-bearing phases. Here, the efficacy of this approach was evaluated through parallel field application and laboratory-based flow-through column experiments. The field site is Huff Run sub-watershed 25 located in Tuscarawas County, Ohio and was chosen in part because it was previously classified as one of the most highly AMD-impacted sub-watersheds in the region. Two locations with historical spoil were chosen and suction lysimeters were installed at 25 and 75 cm depth to monitor porewater composition on two sides at the base of each pile. Half of each slope received seven lime slurry treatments from June through October of 2017. A suite of aqueous (ICP-OES, IC, and TOC-L) and solid phase geochemical and mineralogical approaches (quantitative SEM-EDS and synchrotron μ-XRF) were used to determine how composition, texture, morphology, and spatial distribution of mineral coatings differ in pre- and post-lime treated soils, and how that impacts the distribution and transport of trace metal(loid)s. Mine spoil porewater at site 1 was slightly less alkaline (pH ranging from 7.04 to 7.37) than at site 2 (ranging from 7.55 to 7.71), and average electrical conductivity values at site 1 (316–405 μS cm —1 ) were slightly lower than at site 2 (358–464 μS cm —1 ), although differences between the sites were not significant. Porewater pH and electrical conductivity in all lysimeters decreased over the course of the field season but there was no obvious response to lime treatment at either site or any depth. At site 1, both treatment and depth were significant factors affecting Ca, K, Ni, SO 4 2— , and DOC concentrations while only treatment effects were significant for dissolved Al and Cu (p < 0.05). For all soils, there were no trends in metal concentration observed over time although DOC and SO 4 2— decreased over the field season. Pedon-scale changes in metal porewater concentrations in response to treatment were linked to micrometer-scale changes in mineral surface coatings; specifically, higher concentrations of Ca, Fe, Mn, and Zn were observed in the coatings and no changes were observed in Fe redox speciation, whereas total S decreased likely due to oxidation of S in coal fragments. In contrast to the field experiment, the column experiments exhibited a much greater response in effluent composition with respect to lime treatment. The untreated columns had approximately an order of magnitude more H + leached over the course of the experiment (p < 0.001) and resulted in greater Ca, Al, Cu, and DIC leached and less Mn, Zn, and SO 4 2— . Soils treated with the lime slurry in the column experiments exhibited larger and thicker secondary Fe-coatings, including the addition of Fe-sulfates. Despite clear trends in the laboratory-based column experiment where the lime-to-soil ratio was higher, the effects were either muted or undetected in the field pilot project, suggesting that a higher application rate of lime in the field is needed to achieve a similar effect. This work provides evidence that a less alkaline lime slurry could be a practical and inexpensive method of treating coal mine spoil-impacted soils and represents an important step in linking laboratory-based remediation studies to implemented field-based studies.

58 GEOSCIENCES↗

Estimating Vadose Zone Flow Properties at the 100 K-East Soil Flushing Site Using ERT Monitoring Data: 2023 Interim Report - 100 KE Soil Property Estimation

In situ soil flushing is being using at the Hanford 100 K-East (100 KE) area to transport mobile chromium contamination in the vadose zone to the water table, where it can be collected and treat through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. In practice, it is infeasible to comprehensively monitor which regions of the vadose zone are being infiltrated through direct sampling of pore water. Consequently, there can be significant uncertainty about which regions of the subsurface have been treated, especially if hydrogeologic conditions are favorable for the development of unstable flows and preferred flow pathways through the vadose zone (Jarvis, Koestel, and Larsbo 2016). Current approaches for quantitative monitoring of soil flushing performance rely on contaminant concentration measurements collected from extractions wells. There is no quantitative information on the volume of flush water delivered to targeted regions of the vadose zone at the Hanford Site, leading to significant uncertainty regarding source term removal and long-term impacts to groundwater. If the subsurface hydrogeologic properties at the 100 KE Area were adequately known, qualitative metrics of soil flushing performance could be simulated, thereby negating expenses required to obtain quantitative performance information through borehole drilling/sampling. However, estimating in situ hydrogeologic properties has long proven elusive, due primarily to a lack of sufficient information to constrain heterogeneous property estimates to a useful degree of certainty. Estimating vadose zone hydrogeologic properties is particularly challenging due the dependence of hydraulic conductivity on saturation. This report describes progress toward a first-of-its-kind demonstration using surface time-lapse 3D electrical resistivity tomography (ERT) monitoring data to estimate the hydrogeologic properties that control flush water transport at the 100 KE soil flushing site. The ultimate objective is (1) to verify sufficient information exists in the ERT monitoring data to adequately resolve vadose zone hydraulic properties, and (2) generate a “digital twin” (i.e., a numerical simulator) that can be used to simulate the amount of flush water that has been delivered to each targeted region of the vadose zone, and thereby assess the efficacy of flush water delivery. Resulting performance estimates can be used in leu of comprehensive borehole drilling and direct sampling (or wellbore logging) that would otherwise be required to obtain the same information.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fractionation of mineral species by electrophoresis

The fractionation of fine-grained aggregates into their major components is a problem in many scientific areas including earth and planetary science. Electrophoresis, the transport of electrically charged particles, immersed in a suspension medium, by a direct current field (Bier, 1959), was employed in this study as a means of separating simulated lunar soil into its constituent minerals. In these tests, conducted in a static analytical cylindrical microelectrophoresis apparatus, samples of simulated lunar soil and samples of pure mineral constituents were placed in the chamber; the electrophoretic mobilities of the lunar soil and the individual mineral constituents were measured. In most of the suspension buffers employed separability was indicated, on the basis of differences in mobility, for all the constituent mineral species except ilmenite and pyroxene, which were not efficiently separable in any of the buffers. Although only a few suspension media were employed, the success of this initial study suggests that electrophoresis may be an important mineral fractionation option in fine-grained aggregate processing.

Dunning, J. D.↗

3D hydrogeophysical characterization of managed aquifer recharge basins

Aquifers are increasingly stressed. Managed aquifer recharge provides a potential solution to mitigate this stress and provide sustainable groundwater resources. Subsurface properties are known to have a strong control on the infiltration rates that can be achieved. However, these properties are often highly heterogeneous and difficult to assess with conventional probing techniques. Here, we show the application of 3D geophysical imaging to assess the recharge potential and its variation across several basins used for managed aquifer recharge. We link in-situ measurements of saturated hydraulic conductivity with the electrical resistivity of the subsurface to establish petrophysical relationships and use those relationships to estimate the distribution of hydraulic conductivity throughout the five recharge basins. Our results show a considerable variability in the hydraulic properties, i.e., soil texture and saturated hydraulic conductivity, that have a direct impact on potential infiltration rates. We use the 3D hydraulic property distributions to model groundwater recharge and provide estimates for infiltration rates and volumes, and use this approach to assess the impact of management activities on groundwater recharge performance. Having such data not only enables us to predict infiltration rates, but also provides means for optimizing such water infrastructure.

54 ENVIRONMENTAL SCIENCES↗

Foldable Instrumented Bits for Ultrasonic/Sonic Penetrators

Long tool bits are undergoing development that can be stowed compactly until used as rock- or ground-penetrating probes actuated by ultrasonic/sonic mechanisms. These bits are designed to be folded or rolled into compact form for transport to exploration sites, where they are to be connected to their ultrasonic/ sonic actuation mechanisms and unfolded or unrolled to their full lengths for penetrating ground or rock to relatively large depths. These bits can be designed to acquire rock or soil samples and/or to be equipped with sensors for measuring properties of rock or soil in situ. These bits can also be designed to be withdrawn from the ground, restowed, and transported for reuse at different exploration sites. Apparatuses based on the concept of a probe actuated by an ultrasonic/sonic mechanism have been described in numerous prior NASA Tech Briefs articles, the most recent and relevant being "Ultrasonic/ Sonic Impacting Penetrators" (NPO-41666) NASA Tech Briefs, Vol. 32, No. 4 (April 2008), page 58. All of those apparatuses are variations on the basic theme of the earliest ones, denoted ultrasonic/sonic drill corers (USDCs). To recapitulate: An apparatus of this type includes a lightweight, low-power, piezoelectrically driven actuator in which ultrasonic and sonic vibrations are generated and coupled to a tool bit. The combination of ultrasonic and sonic vibrations gives rise to a hammering action (and a resulting chiseling action at the tip of the tool bit) that is more effective for drilling than is the microhammering action of ultrasonic vibrations alone. The hammering and chiseling actions are so effective that the size of the axial force needed to make the tool bit advance into soil, rock, or another material of interest is much smaller than in ordinary twist drilling, ordinary hammering, or ordinary steady pushing. Examples of properties that could be measured by use of an instrumented tool bit include electrical conductivity, permittivity, magnetic field, magnetic permeability, temperature, and any other properties that can be measured by fiber-optic sensors. The problem of instrumenting a probe of this type is simplified, relative to the problem of attaching electrodes in a rotating drill bit, in two ways: (1) Unlike a rotating drill bit, a bit of this type does not have flutes, which would compound the problem of ensuring contact between sensors and the side wall of a hole; and (2) there is no need for slip rings for electrical contact between sensor electronic circuitry and external circuitry because, unlike a rotating drill, a tool bit of this type is not rotated continuously during operation. One design for a tool bit of the present type is a segmented bit with a segmented, hinged support structure (see figure). The bit and its ultrasonic/sonic actuator are supported by a slider/guiding fixture, and its displacement and preload are controlled by a motor. For deployment from the folded configuration, a spring-loaded mechanism rotates the lower segment about the hinges, causing the lower segment to become axially aligned with the upper segment. A latching mechanism then locks the segments of the bit and the corresponding segments of the slider/guiding fixture. Then the entire resulting assembly is maneuvered into position for drilling into the ground. Another design provides for a bit comprising multiple tubular segments with an inner alignment string, similar to a foldable tent pole comprising multiple tubular segments with an inner elastic cable connecting the two ends. At the beginning of deployment, all segments except the first (lowermost) one remain folded, and the ultrasonic/sonic actuator is clamped to the top of the lowermost segment and used to drive this segment into the ground. When the first segment has penetrated to a specified depth, the second segment is connected to the upper end of the first segment to form a longer rigid tubular bit and the actuator is moved to the upper end of the second segnt. The process as described thus far is repeated, adding segments until the desired depth of penetration has been attained. Yet other designs provide for bits in the form of bistable circular- or rectangular- cross-section tubes that can be stowed compactly like rolls of flat tape and become rigidified upon extension to full length, in a manner partly similar to that of a common steel tape measure. Albeit not marketed for use in tool bits, a bistable reeled composite product that transforms itself from a flat coil to a rigid tube of circular cross section when unrolled, is commercially available under the trade name RolaTube(TradeMark) and serves as a model for the further development of tool bits of this subtype.

Bar-Cohen, Yoseph↗

Cytochrome Nanowire XRD

Microbial metabolism plays an important role in the global cycling of carbon, nutrients, and metals. Recent discovery of microorganisms sharing energy using direct electrical connections might represent a prominent strategy by which anaerobic microorganisms interact with the diversity of environments. The purpose of the proposed research is to apply these newly developed principles of electron exchange in microbial communities to the study of biogeochemical cycling in climate and subsurface systems. Previous studies revealed that soil bacteria Geobacter sulfurreducens produce conductive pili nanofilaments that facilitate long-range electron transport to extracellular electron acceptors and other cells. This discovery has already transformed our understanding of the function of microbial communities in diverse environments, making basic contributions to microbial ecology and helping to improve practical applications such as increasing current output of microbial fuel cells and enhancing the conversion of organic waste to methane. Microbial electron exchange via pili may also contribute to methane production in terrestrial environments that are major sources of atmospheric methane. However, the mechanism of electron transport through pili is not well understood. Initial studies have suggested that pili exhibit metallic-like conductivity similar to conducting polymer polyaniline. However, these studies were limited to electrical measurements. X-ray diffraction studies have suggested that aromatic amino acids tyrosine and phenylalanine are closely packed in pili. But these studies used homology modeling to predict the pilus assembly and information about the number of monomers in each pilus assembly unit and their organization are still lacking. The central hypothesis of this proposal is aromatics in pili enable intermolecular electron delocalization due to pi-stacking that can give rise to metallic-like conductivity. By analyzing pili structure using infrared scattering-scanning near field optical microscope (IR s-SNOM) and combining with solution NMR, Focused Ion Beam (FIB and computational capabilities, this work will provide comprehensive understanding of the conduction mechanism from a structure-function perspective. The specific aims are: 1) With infrared scattering scanning near field optical microscope (IR s-SNOM), image the organization and density of pilin monomers and pH-induced conformational changes in a pilus filament. 2) With solution NMR, resolve pH-induced structural changes in the pilin monomer. 3) Using Focused Ion Beam (FIB), draw electrodes on single pili to measure their conductivity. 4) With computational modeling using the NWChem, simulate the effect of environment on the electronic properties of pili as a function of pH. The proposed work will gain the nanoscale insight into the structure of the pili, as the basis for understanding interspecies electrical communications. The improved understanding will be harnessed to accelerate bioenergy production and bioremediation using pili as well as for predictive modeling of carbon cycling in diverse environments to reach the central goals of DOE-BER to develop sustainable energy sources, regulate the contaminants in the subsurface and understand the effects of greenhouse gas emissions on biosphere. The proposed studies will provide design principles for engineering of electrical interactions among these communities by manipulating the amino acid composition of pili. Moreover, these studies will identify the forces that maintain the function of these communities in the face of environmental perturbation. Therefore, these studies will help to address the need "to incorporate process understanding of biogeochemical cycling into a scalable hierarchy of predictive capabilities" specified in EMSL's Science Themes.

59 BASIC BIOLOGICAL SCIENCES↗

Environment Monitor

Viking landers touched down on Mars equipped with a variety of systems to conduct automated research, each carrying a compact but highly sophisticated instrument for analyzing Martian soil and atmosphere. Instrument called a Gas Chromatography/Mass Spectrometer (GC/MS) had to be small, lightweight, shock resistant, highly automated and extremely sensitive, yet require minimal electrical power. Viking Instruments Corporation commercialized this technology and targeted their primary market as environmental monitoring, especially toxic and hazardous waste site monitoring. Waste sites often contain chemicals in complex mixtures, and the conventional method of site characterization, taking samples on-site and sending them to a laboratory for analysis is time consuming and expensive. Other terrestrial applications are explosive detection in airports, drug detection, industrial air monitoring, medical metabolic monitoring and for military, chemical warfare agents.

Source record↗

Life Cycle Emissions and Health Cost Impacts of Producing Ethanol and Electricity from Willow and Switchgrass in the Riparian Buffers of Mid-Atlantic United States

The United States (US Mid-Atlantic Region (MAR) has the potential to grow a variety of perennial feedstocks such as switchgrass and shrub willow to increase domestic energy production. These cellulosic feedstocks have also shown improved ecosystem services, such as soil carbon sequestration, nitrate leaching reduction, and flood mitigation along rivers and streams as partially harvested riparian buffers. To examine the effects on greenhouse gases (GHGs) and criteria air pollutants (CAPs) from using these feedstocks to produce ethanol or electricity, we conducted a comprehensive life cycle assessment (LCA) and estimated the impact on human health costs when land use is changed from corn production for ethanol. Results indicate up to 54% reduced GHG per hectare from using willow and switchgrass feedstock sources to produce ethanol instead of corn. However, there was a trade-off in terms of CAP emission, as grass-based energy emitted more NO x and SO x compared to the corn ethanol pathway, except for SO X emissions from willow-based electricity. Electricity from cellulosic biomass had higher particulate matter (PM) emission compared to that from corn ethanol. Estimates for health cost to society ranged from $2498 ha –1 for electricity from switchgrass to a net benefit of $448 ha –1 for ethanol production from willow, depending on varying biomass yield under different market scenarios. Although using cellulosic feedstocks to produce bioenergy has great potential to reduce GHG emissions, CAP control measures are needed to manage CAP-induced health costs.

Bioenergy↗

Mapping Near-Surface Salinization Using Long-wavelength AIRSAR

In May 1999, NASA's Jet Propulsion Laboratory acquired airborne synthetic aperture radar (AIRSAR) data over the Hatchel and Montague Test Sites in Texas. We analyzed P- and L-band polarimetric radar data from these AIRSAR missions to assess whether AIRSAR could be used as a rapid and remote platform for screening large areas at risk for near-surface soil and water salinization. Ongoing geological, geophysical, and hydrological studies at the Hatchel Test Site in Runnels County and the Montague Test Site in Montague County have demonstrated the utility of high-resolution airborne electromagnetic (EM) induction in mapping electrical conductivity changes that accompany shallow natural and oil-field related salinization at these sites in the Colorado and Red River basins. We compared AIRSAR and airborne EM data quantitatively by (1) selecting representative flight lines from airborne EM surveys of the Hatchel and Montague sites, (2) extracting measurement locations and apparent conductivities at the highest available EM frequency, (3) identifying and extracting all P- and L-band backscatter intensities for all locations within 5 m of an airborne EM measurement, and (4) examining the spatial and magnitude relationships between apparent conductivity and all radar polarization and polarization-ratio combinations. For both test sites, backscatter intensity in all individual P- and L-band polarizations was slightly negatively correlated with apparent conductivity. In most modes this was manifested as a decrease in the range and magnitude of backscatter intensity as apparent conductivity increased. Select single-band and cross-band polarization ratios exhibited somewhat higher correlation with apparent conductivity by partly diminishing the dominance of the vegetation contribution to V backscatter intensity. The highest correlation with conductivity was obtained using the L-band vertical- to cross-polarization ratio, the P-band vertical- to L-band cross-polarization ratio, and the P-band vertical-to cross-polarization ratio. These correlations were higher for the more arid (and less electrically conductive) Hatchel Test Site than they were for the Montague Test Site.

Paine, Jeffery G.↗

Applications of fibrous substrates containing insolubilized phase change polymers

Incorporation of polyethylene glycols into fibrous substrates produces several improved functional properties when they are insolubilized by crosslinking with a methylolamide resin or by polyacetal formation by their reaction with glyoxal. The range of molecular weights of polyols that may be insolubilized is broad as are the curing conditions (0.25-10 min at 80-200C). Most representative fiber types and blends (natural and synthetic) and all types of fabric constructions (woven, nonwoven and knit) have been modified by incorporation of the bound polyols. The most novel property is the thermal adaptability of the modified substrates to many climatic conditions. This adaptability is due to the high latent heat of the crosslinked polyols that function as phase change materials, the hydrophilic nature of the crosslinked polymer and its enhanced thermal conductivity. Other enhanced properties imparted to fabrics include flex and flat abrasion, antimicrobial activity, reduced static charge, resistance to oily soils, resiliency, wind resistance and reduced lint loss. Applications commercialized in the U.S. and Japan include sportswear and skiwear. Several examples of electric sets of properties useful for specific end uses are given. In addition, other uses are biomedical horticultural, aerospace, indoor insulation, automotive interiors and components and packaging material.

Vigo, Tyrone L.↗

Electrical properties of lunar soil sample 15301,38

Electrical property measurements have been made on an Apollo 15 lunar soil sample in ultrahigh vacuum from room temperature to 827 C for the frequency spectrum from 100 Hz through 1 MHz. The dielectric constant, the total ac loss tangent, and the dc conductivity were measured. The dc conductivity showed no thermal hysteresis, but an irreversible (in vacuum) thermal effect was found in the dielectric loss tangent on heating above 700 C and during the subsequent cooling. This appears to be related to several effects associated with lunar glass above 700 C. The sample also showed characteristic low-frequency dispersion in the dielectric constant with increasing temperature, presumably due to Maxwell-Wagner intergranular effects. The dielectric properties may be fitted to a model involving a Cole-Cole frequency distribution that is relatively temperature-independent below 200 C and follows a Boltzmann temperature distribution with an activation energy of 2.5 eV above 200 C. The dc conductivity is fitted by an exponential temperature distribution and becomes the dominant loss above 700 C.

Olhoeft, G. R.↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

Interim Measure Report South Water Pump Station Potential Release Location 213 – Location of Concern 2 Kennedy Space Center, Florida

This report presents a summary of the polychlorinated biphenyl (PCB) interim measure (IM) activities that occurred in December 2022 and March 2023 at Location of Concern (LOC) 2 – Electrical Equipment Area associated with the South Water Pump Station (SWPS) Potential Release Location (PRL) 213, located at the John F. Kennedy Space Center (KSC), Florida. The SWPS site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. Assessment activities have previously been performed at six SWPS LOCs identified during a Solid Waste Management Unit assessment in 2013. Based on the data collected during these assessments, it was determined that IM activities would be completed at one of the LOCs, LOC 2 – Electrical Equipment Area, and an IM Work Plan was prepared and approved. In 2019, demolition of the SWPS buildings and structures was completed, allowing for additional assessment at LOC 2, and it was determined that soil excavation to remove PCB-impacted soils was no longer required for LOC 2. The IM activities conducted following demolition are presented in this report and include shallow soil sample collection, conducted in December 2022, and monitoring well installation and groundwater sampling, both conducted in March 2023. AECOM Technical Services, Inc. (AECOM) personnel collected two soil samples from two boring locations, SWPS-SB0005 and SWPS-SB0018. The samples were collected at 0 to 0.5 feet below land surface (bls). AECOM also conducted oversight of one monitoring well installation, SWPS-MW0001 screened from 4 to 14 feet bls, and then subsequently collected one groundwater sample from SWPS-MW0001. The samples were submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 8082A for total PCBs. There were no detections of PCBs in soil or groundwater during the reporting period.

Chadwick Sloan Lee↗