Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Application of eye tracking for measurement and evaluation in human factors studies in control room modernization - 309

An important element of human factors engineering (HFE) pertains to measurement and evaluation (M and E). The role of HFE-M and E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collect and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M and E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M and E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synchrotron‐source micro‐x‐ray computed tomography for examining butterfly eyes

Comparative anatomy is an important tool for investigating evolutionary relationships among species, but the lack of scalable imaging tools and stains for rapidly mapping the microscale anatomies of related species poses a major impediment to using comparative anatomy approaches for identifying evolutionary adaptations. We describe a method using synchrotron source micro-x-ray computed tomography (syn-μXCT) combined with machine learning algorithms for high-throughput imaging of Lepidoptera (i.e., butterfly and moth) eyes. Our pipeline allows for imaging at rates of ~15 min/mm 3 at 600 nm 3 resolution. Image contrast is generated using standard electron microscopy labeling approaches (e.g., osmium tetroxide) that unbiasedly labels all cellular membranes in a species-independent manner thus removing any barrier to imaging any species of interest. To demonstrate the power of the method, we analyzed the 3D morphologies of butterfly crystalline cones, a part of the visual system associated with acuity and sensitivity and found significant variation within six butterfly individuals. Despite this variation, a classic measure of optimization, the ratio of interommatidial angle to resolving power of ommatidia, largely agrees with early work on eye geometry across species. We show that this method can successfully be used to determine compound eye organization and crystalline cone morphology. Our novel pipeline provides for fast, scalable visualization and analysis of eye anatomies that can be applied to any arthropod species, enabling new questions about evolutionary adaptations of compound eyes and beyond.

59 BASIC BIOLOGICAL SCIENCES↗

Electron dose distributions caused by the contact-type metallic eye shield: Studies using Monte Carlo and pencil beam algorithms

A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shield was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Eye-Safe 1.5 and 2.0 Micron Laser Power Conversion Using Metamorphic InGaAs Photovoltaic Devices

Laser power transmission at 1.5 and 2.0 microns are considered eye-safe up to 0.1 W/cm2 irradiance. Further, the atmospheric bands at these two wavelengths may provide the highest optical transmission through the atmosphere in hazy conditions. By slowly changing the lattice-constant of InGaAs with a Compositionally Graded Buffer (CGB), we have fabricated InGaAs photovoltaic (PV) devices over a wide range of bandgaps useful for multijunction concentrating photovoltaic devices, thermophotovoltaic devices, and Laser Power Converters (LPC). Here, we have demonstrated monochromatic power conversion of 1.5-micron light with an eye-safe efficiency of 39.8% at 0.1 W/cm2 with InGaAs devices lattice-matched to InP with an Antireflection Coating (ARC). We have also demonstrated 30.2% and 24.5% eye-safe LPC efficiency of metamorphic InGaAs devices grown on GaAs substrates using GaInP and AlGaAsP CGBs, respectively. Finally, we have demonstrated metamorphic InGaAs devices grown on InP and GaAs substrates that are estimated to have eye-safe LPC efficiencies at 2.0 microns of 27.4% and 20.9% respectively. The efficiencies of all these LPC devices continues to increase up to about 30-70 times the eye-safe irradiance.

eye-safe↗

Parabolic flight reveals independent binocular control of otolith-induced eye torsion

To examine otolith-governed ocular torsion in hyper- and hypogravity, eight subjects, including two astronauts, underwent parabolic flight while seated upright with head fixed. A mask fitted with two video cameras provided synchronized images of both eyes at a rate of 25/sec during 15 parabolas, the individual parabolas separated by a few minutes of level 1 G flight. Three main findings emerged: 1) After the first parabola, most subjects showed differential torsional offset of the two eyes in the 1 G portions between parabolas, compared to the conjugate baseline position of the eyes prior to the first parabola. 2) Changes in binocular torsion in the 0 G and 1.8 G portions of parabolic flight revealed in most subjects systematic reversal of direction. The reversal was consistent within, but not across subjects. 3) Disconjugacy defined as the moment-to-moment difference in the movements of the two eyes, and evaluated without the contribution of the differential offset, found two subjects with relatively high disconjugacy scores, and the remaining six with low scores. On the basis of prior studies (9, 20), we would predict the first two would be subject to SMS, the remainder not. The two astronauts, who did not have SMS on their space missions, fell into the low scoring group. We propose that the disconjugacies may be due to intrinsic asymmetries in the otolith receptors on the two sides of the head, which appear to be independently linked to the extraocular muscles of the two eyes, a phenomenon masked in normal 1 G states by adaptation. The apparently independent control of the two sides cannot be detected by the simpler and more common monocular studies.

Non-NASA Center↗

Oculomotor control of primary eye position discriminates between translation and tilt

We have previously shown that fast phase axis orientation and primary eye position in rhesus monkeys are dynamically controlled by otolith signals during head rotations that involve a reorientation of the head relative to gravity. Because of the inherent ambiguity associated with primary otolith afferent coding of linear accelerations during head translation and tilts, a similar organization might also underlie the vestibulo-ocular reflex (VOR) during translation. The ability of the oculomotor system to correctly distinguish translational accelerations from gravity in the dynamic control of primary eye position has been investigated here by comparing the eye movements elicited by sinusoidal lateral and fore-aft oscillations (0.5 Hz +/- 40 cm, equivalent to +/- 0.4 g) with those during yaw rotations (180 degrees/s) about a vertically tilted axis (23.6 degrees). We found a significant modulation of primary eye position as a function of linear acceleration (gravity) during rotation but not during lateral and fore-aft translation. This modulation was enhanced during the initial phase of rotation when there was concomitant semicircular canal input. These findings suggest that control of primary eye position and fast phase axis orientation in the VOR are based on central vestibular mechanisms that discriminate between gravity and translational head acceleration.

NASA Discipline Neuroscience↗

Properties of cerebellar fastigial neurons during translation, rotation, and eye movements

The most medial of the deep cerebellar nuclei, the fastigial nucleus (FN), receives sensory vestibular information and direct inhibition from the cerebellar vermis. We investigated the signal processing in the primate FN by recording single-unit activities during translational motion, rotational motion, and eye movements. Firing rate modulation during horizontal plane translation in the absence of eye movements was observed in all non-eye-movement-sensitive cells and 26% of the pursuit eye-movement-sensitive neurons in the caudal FN. Many non-eye-movement-sensitive cells recorded in the rostral FN of three fascicularis monkeys exhibited convergence of signals from both the otolith organs and the semicircular canals. At low frequencies of translation, the majority of these rostral FN cells changed their firing rates in phase with head velocity rather than linear acceleration. As frequency increased, FN vestibular neurons exhibited a wide range of response dynamics with most cells being characterized by increasing phase leads as a function of frequency. Unlike cells in the vestibular nuclei, none of the rostral FN cells responded to rotational motion alone, without simultaneously exhibiting sensitivity to translational motion. Modulation during earth-horizontal axis rotation was observed in more than half (77%) of the neurons, although with smaller gains than during translation. In contrast, only 47% of the cells changed their firing rates during earth-vertical axis rotations in the absence of a dynamic linear acceleration stimulus. These response properties suggest that the rostral FN represents a main processing center of otolith-driven information for inertial motion detection and spatial orientation.

Non-NASA Center↗

Mapping the Residual Stress Distribution in Polycrystalline Quartz Tiger's Eye Using Raman Spectroscopy

Stress distribution maps in polycrystalline materials are needed to reveal stress pathways caused by short‐and long‐range interactions of crystallites. Stress induced changes to wavenumbers in Raman spectroscopy is a well‐known phenomenon that occurs when a crystalline material undergoes elastic strain. Using spatially resolved Raman spectroscopy, we have developed a technique to experimentally measure grain‐scale residual stresses across a sample of polycrystal quartz Tiger's Eye. The results of this technique are validated using multiple criteria, including evaluation of the residual stress map itself and the accuracy of the measurements taken. The residual map of Tiger's Eye shows striking similarity to observed characteristics of other polycrystalline residual stress distributions, revealing heterogenous areas of high and low magnitude stresses. The stress magnitudes are consistent with residual stress magnitudes previously measured from polycrystalline quartz. Characterization of Tiger's Eye quartz also revealed the geometric nature of the iron oxide inclusions, not previously observed in Tiger's Eye quartz. With this technique, we present a residual stress map of Tiger's Eye quartz that shows with accuracy a heterogeneous stress state with inter‐ and intra‐granular detail.

36 MATERIALS SCIENCE↗

Quantum eye: Lattice plasmon effect on quantum fluctuations and photon detection

In this work, arrays of plasmonic nanoparticles coupled to a detector are designed and considered as a quantum eye. In the designed system, the plasmonic nanoparticles have a role like an ommatidium in the artificial compound eye; however, the quantum eye ommatidium acts with different functionality. To better understand this system, we analyze it with the full quantum theory, quantize lattice plasmon generated by the array of plasmonic nanoparticles, and finally derive bosonic operators using Heisenberg–Langevin equations. Moreover, we theoretically derive the radiative and non-radiative losses introduced by this system and examine lattice plasmon effect on spontaneous emission of the quantum dot (Purcell factor). The main goal of this article is to investigate the quantum eye’s quantum properties such as quantum fluctuations, which is modeled and analyzed by studying the second-order correlation function. This function exhibits a significant bunching as a function of lattice plasmon optical properties. We can easily manipulate and improve the lattice plasmon optical properties, which dramatically depend on the array geometry. Finally, we study the quantum eye photon detection by a quantum measuring approach and show that the lattice plasmon has a strong effect on quantum properties after the one-count process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical Modeling of the Eye for Multimodal Treatment Planning for External Beam Radiation Therapy of Intraocular Tumors

Purpose: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. Methods and Materials: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. Results: Cross-validation revealed a dice similarity of 95% {+-} 2% for the sclera and cornea and 91% {+-} 2% for the lens. Overall, mean segmentation error was found to be 0.3 {+-} 0.1 mm. Average segmentation time was 14 {+-} 2 s on a standard personal computer. Conclusions: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A biomimetic eye with a hemispherical perovskite nanowire array retina

Human eyes possess exceptional image-sensing characteristics such as an extremely wide field of view, high resolution and sensitivity with low aberration1. Biomimetic eyes with such characteristics are highly desirable, especially in robotics and visual prostheses. However, the spherical shape and the retina of the biological eye pose an enormous fabrication challenge for biomimetic devices2,3. In this paper, we present an electrochemical eye with a hemispherical retina made of a high-density array of nanowires mimicking the photoreceptors on a human retina. The device design has a high degree of structural similarity to a human eye with the potential to achieve high imaging resolution when individual nanowires are electrically addressed. Additionally, we demonstrate the image-sensing function of our biomimetic device by reconstructing the optical patterns projected onto the device. This work may lead to biomimetic photosensing devices that could find use in a wide spectrum of technological applications.

42 ENGINEERING↗

Fabrication of moth-eye structures on silicon by direct six-beam laser interference lithography

This paper presents a new method for the generation of cross-scale laser interference patterns and the fabrication of moth-eye structures on silicon. In the method, moth-eye structures were produced on a surface of silicon wafer using direct six-beam laser interference lithography to improve the antireflection performance of the material surface. The periodic dot arrays of the moth-eye structures were formed due to the ablation of the irradiance distribution of interference patterns on the wafer surface. The shape, size, and distribution of the moth-eye structures can be adjusted by controlling the wavelength, incidence angles, and exposure doses in a direct six-beam laser interference lithography setup. The theoretical and experimental results have shown that direct six-beam laser interference lithography can provide a way to fabricate cross-scale moth-eye structures for antireflection applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel lobster-eye imaging system based on Schmidt-type objective for X-ray-backscattering inspection

This paper presents a novel lobster-eye imaging system for X-ray-backscattering inspection. The system was designed by modifying the Schmidt geometry into a treble-lens structure in order to reduce the resolution difference between the vertical and horizontal directions, as indicated by ray-tracing simulations. The lobster-eye X-ray imaging system is capable of operating over a wide range of photon energies up to 100 keV. In addition, the optics of the lobster-eye X-ray imaging system was tested to verify that they meet the requirements. X-ray-backscattering imaging experiments were performed in which T-shaped polymethyl-methacrylate objects were imaged by the lobster-eye X-ray imaging system based on both the double-lens and treble-lens Schmidt objectives. The results show similar resolution of the treble-lens Schmidt objective in both the vertical and horizontal directions. Moreover, imaging experiments were performed using a second treble-lens Schmidt objective with higher resolution. The results show that for a field of view of over 200 mm and with a 500 mm object distance, this lobster-eye X-ray imaging system based on a treble-lens Schmidt objective offers a spatial resolution of approximately 3 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of voluntary eye movement and convergence on the binocular appreciation of depth.

Scaling techniques were employed to establish the relation between perceived distance ratio and physical distance ratio. Measurements were made both with and without free eye movement and under two states of convergence. The results were confirmed using a matching technique. With free eye movement, the perceived ratio is a monotonic increasing function of the physical ratio. Without eye movement, the perceived ratio generally increases, then decreases, as the physical ratio increases. For a given physical ratio, perceived distance ratio is less in the absence of voluntary eye movements. Convergence produces depth micropsia when eye movements are permitted, but not in their absence.

Foley, J. M.↗

Human eye movements during various forms of linear acceleration and weightlessness

Eye movements of human subjects were recorded electronystagmographically in complete darkness during rectilinear horizontal accelerations as achieved in cars on the ground and also during aircraft parabolic flight. The results were compared to the movements of blinded goldfish subjected to similar changes of gravitoinertial forces. The results indicate that there is a human correlation with the gravity reference response of fish. During horizontal forward accelerations on the ground the human eyes turn downward and during horizontal backward acceleration the eyes turn upward. The human eye response to g-loads below 1 g and to weightlessness is the reverse of the tilt of the fish. While fish dive down during low g, or loop forward during weightlessness, the eyes of subjects sitting upright in an aircraft which flies at 0 g move upward.

Vonbaumgarten, R. J.↗

A relationship between eye movement patterns and performance in a precognitive tracking task

Eye movements made by various subjects in the performance of a precognitive tracking task are studied. The tracking task persented by an antiaircraft artillery (AAA) simulator has an input forcing function represented by a deterministic aircraft fly-by. The performance of subjects is ranked by two metrics. Good, mediocre, and poor trackers are selected for analysis based on performance during the difficult segment of the tracking task and over replications. Using phase planes to characterize both the eye movement patterns and the displayed error signal, a simple metric is developed to study these patterns. Two characterizations of eye movement strategies are defined and quantified. Using these two types of eye strategies, two conclusions are obtained about good, mediocre, and poor trackers. First, the eye tracker who used a fixed strategy will consistently perform better. Secondly, the best fixed strategy is defined as a Crosshair Fixator.

Repperger, D. W.↗

Restriction of pursuit eye movement range during a concurrent auditory task

A two-part experiment was performed using 10 naive adult male subjects to determine the effects of a concurrent auditory dot/dash identification task on pursuit eye movements. Results indicated there was a significant (20 percent) but transitory task-induced restriction of the range of both an 18 deg horizontal and a 14 deg vertical pursuit eye movement visual angle. Furthermore, doubling the presentation rate of the concurrent task accounted for an additional 5 percent restriction of pursuit eye movement range. Results also indicated that the eye movement range is unaffected by both prior knowledge of the task and four consecutive practice trials. It is suggested that both the rapidity of target movement and the presence of concurrent mental tasks could significantly shrink an operator's pursuit eye movement ranges during viewing of dynamic visual displays such as airborne low-level television and forward-looking infrared.

Malmstrom, F. V.↗

Eye-scan behavior in a flight simulation task as a function of level of training

The present study explored eye-scan behavior as a function of level of subject training. Oculometric (eye-scan) measures were recorded from each of ten subjects during training trials on a CRT-based flight simulation task. The task developed for the study incorporated subtasks representative of specific activities performed by pilots, but which could be performed at asymptotic levels within relatively short periods of training. Changes in eye-scan behavior were examined as initially untrained subjects developed skill in the task. Eye-scan predictors of performance on the task were found. Examination of eye-scan in proximity to selected task events revealed differences in the distribution of looks at the instruments as a function of level of training.

Comstock, J. R., Jr.↗