Hybrid theory calculation of electron-N2 scattering at 5 and 10 eV

Hybrid theory results pertaining to e-N2 scattering have been evaluated for differential elastic and first vibrational excitation cross sections at 5 and 10 eV. Comparison with the recent experiment of Chutjian, Srivastava, and Trajmar is good (1976), although there is an indication that the calculated nonresonant (adiabatic-nuclei) contribution is somewhat too small. A short discussion engendered by this point is given.

Chandra, N.↗

Absolute elastic differential electron scattering cross sections for He - A proposed calibration standard from 5 to 200 eV

Absolute differential, integral, and momentum-transfer cross sections for electrons elastically scattered from helium are reported for the impact energy range of 5 to 200 eV. Angular distributions for elastically scattered electrons are measured in a crossed-beam geometry using a collimated, differentially pumped atomic-beam source which requires no effective-path-length correction. Below the first inelastic threshold the angular distributions were placed on an absolute scale by use of a phase-shift analysis. Above this threshold, the angular distributions from 10 to 140 deg were fitted using the phase-shift technique, and the resulting integral cross sections were normalized to a semiempirically derived integral elastic cross section. Depending on the impact energy, the data are estimated to be accurate to within 5 to 9%.

Register, D. F.↗

Straight and chopped dc performance data for a General Electric 5BT 2366C10 motor and an EV-1 controller

Performance data on the General Electric 5BT 2366C10 series wound dc motor and EV-1 Chopper Controller is supplied for the electric vehicle manufacturer. Data is provided for both straight and chopped dc input to the motor, at 2 motor temperature levels. Testing was done at 6 voltage increments to the motor, and 2 voltage increments to the controller. Data results are presented in both tabular and graphical forms. Tabular information includes motor voltage and current input data, motor speed and torque output data, power data and temperature data. Graphical information includes torque-speed, motor power output-speed, torque-current, and efficiency-speed plots under the various operating conditions. The data resulting from this testing shows the speed-torque plots to have the most variance with operating temperature. The maximum motor efficiency is between 86% and 87%, regardless of temperature or mode of operation. When the chopper is utilized, maximum motor efficiency occurs when the chopper duty cycle approaches 100%.

Edie, P. C.↗

Straight and chopped dc performance data for a Prestolite MTC-4001 motor and a general electric EV-1 controller

Performance data on the Prestolite MTC-4001 series wound dc motor and General Electric EV-1 Chopper Controller is supplied for the electric vehicle manufacturer. Data are provided for both straight and chopped dc input to the motor, at 2 motor temperature levels. Testing was done at 6 voltage increments to the motor, and 2 voltage increments to the controller. Data results are presented in both tabular and graphical forms. Tabular information includes motor voltage and current input data, motor speed and torque output data, power data and temperature data. Graphical information includes torque-speed, motor power output-speed, torque-current, and efficiency-speed plots under the various operating conditions. The data resulting from this testing show the speed-torque plots to have the most variance with operating temperature. The maximum motor efficiency is between 76% and 82%, regardless of temperature or mode of operation.

Edie, P. C.↗

Bi-directional streaming of solar wind electrons greater than 80 eV - ISEE evidence for a closed-field structure within the driver gas of an interplanetary shock

In near time coincidence with the arrival of helium enriched plasma driving the shock wave disturbance of November 12-13, 1978, strong bi-directional streaming of solar wind electrons greater than about 80 eV was observed with Los Alamos instrumentation on ISEE 3. The streaming persisted for many hours simultaneously parallel and anti-parallel to the interplanetary magnetic field which was directed roughly perpendicular to the sun-satellite line. This example of bidirectional streaming cannot be explained by field line connection to the earth's bow shock or the outward propagating interplanetary shock which passed ISEE 3 approximately 16 hours earlier. The event is explained if the local interplanetary field was a part of a magnetic bottle rooted at the sun or a disconnected loop propagating outward.

Bame, S. J.↗

Excitation cross sections for krypton by electrons in the 15-100-eV impact-energy range

Differential, integral, and momentum-transfer cross sections have been determined for the excitation of the 24 lowest electronic states of Kr (some of the transitions are unresolved). The inelastic-scattering cross sections were normalized to the absolute scale with the help of the elastic-scattering differential cross sections (DCS's) which in turn were normalized with respect to absolute He DCS's. The impact energies were 15, 20, 30, 50, and 100 eV and the DCS's were obtained over the range of 5-135 deg scattering angles. The error limits associated with the differential, integral, and momentum-transfer cross sections have been estimated at 25%, 38%, and 46%, respectively.

Trajmar, S.↗

Straight and chopped DC performance data for a General Electric 5BY436A1 DC shunt motor with a General Electric EV-1 controller

Both straight and chopped dc motor performance data for a General Electric 5BY436A1 motor with a General Electric EV-1 controller is presented in tabular and graphical formats. Effects of motor temperature and operating voltage are also shown. The maximum motor efficiency is approximately 85% at low operating temperatures in the straight dc mode. Chopper efficiency can be assumed to be 95% under all operating conditions. For equal speeds, the motor operated in the chopped mode develops slightly more torque and draws more current than it does in the straight mode.

Edie, P. C.↗

Energy accommodation of 5-50 eV ions within an enclosure

Beams of 5-50 eV He(+), Ar(+), Ne(+), O(+), and N2(+) ions were directed into an aluminum sphere, and the equilibrium number density of the atom or molecules was measured inside the sphere using a quadrupole mass spectrometer and signal averaging techniques. The equilibrium number density is inversely proportional to the average speed of the atoms; thus, the results are expressed in terms of the speed ratio, R = V(i)/V(s), where V(i) is the average speed within the enclosure, and V(s) is the average speed of atoms fully accommodated to the temperature of the wall. The speed ratios vary between 1.0 and 1.8. For N2, several values of R were less than 1; this was largely due to desorbed N2. There was no detectable number density for O, which is explained by the reaction of O with the surface.

Humphris, R. R.↗

Primary proton and helium spectra in the energy range 10 to the 12th to 10 to the 14th eV

Measurements of proton and helium spectra have been made in the energy range 10 to the 12th to 10 to the 14th eV. Large area thin emulsion calorimeters were used in the Japanese American Cooperative Emulsion Experiment balloon flight series. Power indices of the integral spectra for both nuclei are consistent with published data at lower energies. Absolute intensities are also consistent for helium and proton fluxes with extrapolations of previous data. No steepening of the proton spectrum is indicated.

Gregory, J. C.↗

Low-energy (less than 100 eV) ion pitch angle distributions in the magnetosphere by ISEE 1

Attention is given to isotropic distribution, bidirectional field alignment distribution, unidirectional field alignment distribution, and low flux, in a statistical examination of low energy ion data from the ISEE 1 plasma composition experiment whose aim was the study of pitch angle distributions in all local times of the magnetosphere. The isotropic distribution consisting of less than 10 eV ions is a persistent inner region feature, while the bidirectional field-aligned distribution consisting of warm ions is a persistent feature of the outer dayside and is seen just outside the isotropic distribution region of the nightside. On the outer nightside, the unidirectional field-aligned distribution consisting of warm ions is the dominant signature. The 'sources' of ions in various regions are discussed in view of the present and other results.

Johnson, J. F. E.↗

Development of an apparatus for obtaining molecular beams in the energy range from 2 to 200 eV

The formation and detection of molecular beams obtained by charge exchange from a low-energy ion source is discussed. Dispersion in energy of the ion source was measured and problems concerning detection of neutral beams were studied. Various methods were used, specifically secondary electron emissivity of a metallic surface and ionization of a gas target with a low ionization voltage. The intensities of neutral beams as low as 10 eV are measured by a tubular electron multiplier and a lock-in amplifier.

Clapier, R.↗

Observations of Cygnus X-3 above 10(15) eV from 1979 - 1984

The ultra high energy gamma-ray source, cygnus X-3, has been observed more or less continuously with an array sensitive to 10 to the 15th power ev primaries between 1 Jan. 1979 and 31 Dec. 1984. There is evidence for time variability in the phase of gamma-ray emission over this period.

Lambert, A.↗

Periodic gamma-ray emissions from Geminga at or = 10(12) eV

Analysis of data from an atmospheric Cerenkov telescope indicated the periodic emission of gamma rays of energy 10 to the 12th power eV, at 60.25 second period, from 2CG 195+4. The gamma ray flux at 99% confidence level is estimated to be 9.5 x 10 to 12 photons/sq cm/s.

Kaul, R. K.↗

Observations of potential ultra high energy gamma-ray sources above 10(15) eV

The Haverah Park 50 m water-Cerenkov array has been used to examine a number of periodic sources for ultra high energy gamma-ray emission above 10 to the 15th power eV. The data, recorded between 1 Jan. 1979 and 31 Dec. 1984, feature a modest angular resolution of approx 3 deg with millisecond arrival time resolution post 1982. The sources investigated include the Crab pulsar, Her X-1, Au0115 + 63 and Geminga. All objects have been detected by workers in the TeV region, with varying degrees of confidence.

Lambert, A.↗

Observation of gamma-rays from LMC X-4 above 10(16) eV

Data from the University of Adelaide air shower array at Buckland Park taken over a three year period have been analyzed to search for evidence of ultra high energy gamma-ray emission from neutron star binary X-ray sources having known orbital periods. The detection of UHE gamma-rays from LMC X-4 above 10 to the 16th power eV, is reported; the first extragalactic object to be positively detected at these energies.

Protheroe, R. J.↗

Primary cosmic ray spectrum in the 10 to the 12th power - 10 to the 16th power eV energy range from the NUSEX experiment

A primary cosmic ray spectrum was derived which fits both experimental multiple muon rates and the all-nucleon flux derived from the single muon intensities underground. In the frame of the interaction model developed by Gaisser, Elbert and Stanev, it is possible to reproduce NUSEX muon data with a primary composition in which the iron spectrum is only slightly flatter than the proton one. This result rules out the popular idea that the primary composition varies drastically with increasing energy, leading to the dominance of heavier nuclei at energies 10 to the 15th power to 10 to the 16th power eV.

Battistoni, G.↗