Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ESI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Applying an Internal Standard to Improve the Repeatability of In-electrospray H/D Exchange of Carbohydrate-Metal Adducts

In-electrospray (ESI) hydrogen/deuterium exchange–mass spectrometry (HDX-MS) has been used to characterize solvated carbohydrate structures. However, the rapid exchange rate of hydroxyls, as well as variations in source conditions and ambient humidity, alter the extent of forward and back exchange, resulting in poor repeatability when quantifying D-uptake on different days. Herein, we compare two internal standards, a peptide and derivatized carbohydrate, to improve the repeatability of in-ESI HDX of carbohydrate-metal adducts. Our results show that maltoheptaose, derivatized with Girard’s T reagent, is a suitable internal standard for improving the repeatability of in-ESI HDX analyses of carbohydrates of varying size. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development and biodistribution studies of 77 As-labeled trithiol RM2 bioconjugates for prostate cancer: Comparison of [ 77 As]As-trithiol-Ser-Ser-RM2 vs. [ 77 As]As-trithiol-Glu-Ser-RM2

Recent progress with the production of 72 As (2.49 Mev β + max (64%), 3.33 Mev β + max (16%), 834 keV (81%), t 1/2 : 26 h) and 77 As (0.683 Mev β- max (97%), 239 keV (1.59%), t 1/2 : 38.8 h) has facilitated their evaluation as a potential “theranostic pair” for PET imaging and radiotherapy. Our 3 rd generation trithiol chelate with two carboxylic acid groups was further developed as a bifunctional chelate for radioarsenic. The As complex with the trithiol chelate was synthesized and characterized. No carrier added (nca) [ 77 As][H 2 AsO 4 - ] was used for radiolabeling studies. Here, the trithiol chelate was conjugated to the RM2 peptide (DPhe-Gln-Trp-Ala-VaI-Gly-His-Sta-Leu-NH 2 ) via solid phase peptide synthesis with two different linkers, Ser-Ser and Glu-Ser. The trithiol chelate and its RM2 bioconjugates were radiolabeled with nca 77 As, and the RM2 bioconjugates were compared in initial biodistribution studies. The As diacid trithiol complex was characterized by 1 H NMR, 13 C NMR and HR-ESI-MS. The trithiol-RM2 precursor and As trithiol bioconjugates were characterized by HR-ESI-MS and/or LC-ESI-MS. Radiolabeling of the RM2 bioconjugates with 77 As resulted in over 85% radiochemical yield for [ 77 As]As-trithiol-Ser-Ser-RM2 ([ 77 As]8) and 90% for [ 77 As]As-trithiol-Glu-Ser-RM2 ([ 77 As]9). Both radiotracers demonstrated excellent in vitro stability (≥ 90% remaining intact through 24 h in PBS buffer) and were more hydrophilic than previous analogues based on log D 7.4 values. Biodistribution results of the two radiotracers in healthy CF-1 male mice demonstrated blockable pancreatic uptake at 1 h (82% for ([ 77 As]8 and 78% for [ 77 As]9) indicating specific gastrin-releasing peptide receptor (GRPR) uptake. The primary route of excretion was through the gastrointestinal system for both radiotracers. A new trithiol chelate with improved hydrophilicity was successfully conjugated to the RM2 peptide via two linkers, and high radiolabeling yield with nca 77 As was achieved. In vivo biodistribution studies with both radiotracers demonstrated blockable pancreatic uptake suggestive of specific receptor uptake.

07 ISOTOPE AND RADIATION SOURCES↗

In Situ Liquid Secondary Ion Mass Spectrometry: A Surprisingly Soft Ionization Process for Investigation of Halide Ion Hydration

The understanding of ion solvation phenomenon is of significance due to their influences on many important chemical, biological and environmental processes. Mass spectrometry (MS) based methods have been used to investigate this topic with molecular insights. As ion-solvent interactions are weak, ionization processes should be as soft as possible in order to retain solvation structures. An in situ liquid secondary ion MS (SIMS) approach developed in our group has been recently utilized in investigations of Li ion solvation in non-aqueous solution and detected a series of solvated Li ions. As traditionally SIMS has long been recognized as a hard ionization process with strong damage occurring at the sputtering interface, it is very interesting to study further how soft in situ liquid SIMS can be. In this work, we used halide ion hydration as an example to compare the ionization performance of in situ liquid SIMS approach with regular electrospray ionization MS (ESI-MS). Results show that although ESI has been recognized as a soft ionization method, nearly no solvated halide ions were detected by ESI-MS analysis, which acquired only strong signals of salt ion clusters. In contrast, in liquid SIMS spectra, a series of obvious hydrated halide ion compositions could be observed. We further evaluated the hydration numbers of halide ions and revealed the effects of the ion size, charge density and polarizability on the hydration phenomenon. Our findings demonstrated that the in situ liquid SIMS approach is surprisingly soft, and expected to have very broad applications on investigation of various ion-solvent interactions and many other interesting chemical processes (e.g., the initial nucleation of nanoparticle formation) in liquid environment.

Zhang, Yanyan↗

Droplet Imbibition Enables Nonequilibrium Interfacial Reactions in Charged Microdroplets

A droplet imbibition experiment is proposed to study interfacial effects, which appears to be the main factor influencing reaction acceleration in charged microdroplets produced by electrospray ionization (ESI). One reagent is deposited onto the surface of rapidly moving microdroplets containing the second reagent to be reacted. In this manner, reactions are hindered from reaching equilibrium and monitored in real time by mass spectrometry. We demonstrated this phenomenon using Katritzky chemistry, which is known to proceed either by the solvent-stabilized 2H-pyran intermediate or via the surface-active pseudobase intermediate. Additionally, comparisons with reactions performed using ESI show obvious surface effects in favor of the droplet imbibition experiment. By keeping reactant mole ratio constant, it was demonstrated that similar interfacial effects observed in the droplet imbibition experiment can be reached by allowing ESI microdroplets containing premixed reagents to traverse a distance >16 mm. At such spray distance, molecular diffusion and droplet lifetime become comparable allowing reactants to be enriched at droplet surface. Reactions were also conducted in rapid mixing, theta capillary-based droplets, which showed markedly reduced yields compared with the interfacial droplet imbibition experiment.

36 MATERIALS SCIENCE↗

Compositional analysis of organosolv poplar lignin by using high-performance liquid chromatography/high-resolution multi-stage tandem mass spectrometry

Organosolv treatment is an efficient and environmentally friendly process to degrade lignin into small compounds. The capability of characterizing the individual compounds in the complex mixtures formed upon organosolv treatment is essential for the optimization of the further lignin conversion processes and for the rational genetic engineering of plants used to produce lignin in order to improve lignin properties. In this study, an organosolv poplar lignin sample was initially analyzed by high-resolution mass spectrometry coupled with negative-ion mode electrospray ionization ((-)ESI HRMS). Lignin monomers and dimers were found to constitute the majority of the compounds in the organosolv lignin sample. Larger lignin oligomers, such as trimers and tetramers, and some not lignin-related compounds, were also detected. A high-performance liquid chromatograph/linear quadrupole ion trap/orbitrap mass spectrometer capable of multi-stage high-resolution tandem mass spectrometry experiments (HRMS n ), equipped with an (-)ESI source (HPLC/(-)ESI HRMS n ), was employed to separate the unknown compounds in the organosolv mixture and to obtain structural information for the deprotonated compounds via collision-activated dissociation (CAD) HRMS n experiments. To improve the understanding of the CAD behavior of deprotonated lignin-related compounds, 16 deprotonated model compounds with different functionalities and linkage types were examined. This approach enabled the assignment of likely structures for several lignin monomers, dimers, trimers, and tetramers, and some not lignin-related compounds, most likely fatty acids. Based on the proposed structures, compounds in the organosolv lignin sample contain β-O-4, 5–5, β-5, and possibly also 4-O-5 linkages. Most compounds contain G- and S-monomeric units although a small amount of H-units were also detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optically detected, single nanoparticle mass spectrometer with pre-filtered electrospray nanoparticle source

An instrument designed for non-destructive mass analysis of single trapped nanoparticles is described. The heart of the instrument is a 3D quadrupole (Paul) trap constructed to give optical access to the trap center along ten directions, allowing passage of lasers for particle heating and detection, particle injection, collection of scattered or fluorescent photons for particle detection and mass analysis, and collection of particles on TEM grids for analysis, as needed. Nanoparticles are injected using an electrospray ionization (ESI) source, and conditions are described for spraying and trapping polymer particles, bare metal particles, and ligand stabilized particles with masses ranging from 200 kDa to >3 GDa. Conditions appropriate to ESI and injection of different types of particles are described. The instrument is equipped with two ion guides separating the ESI source and nanoparticle trap. The first ion guide is mostly to allow desolvation and differential pumping before the particles enter the trap section of the instrument. The second is a linear quadrupole guide, which can be operated in mass selective or mass band-pass modes to limit transmission to species with mass-to-charge ratios in the range of interest. With a little experience, the design allows injection of single particles into the trap upon demand.

36 MATERIALS SCIENCE↗

CFM-ID 4.0 – a web server for accurate MS-based metabolite identification

The CFM-ID 4.0 web server (https://cfmid.wishartlab.com) is an online tool for predicting, annotating and interpreting tandem mass (MS/MS) spectra of small molecules. It is specifically designed to assist researchers pursuing studies in metabolomics, exposomics and analytical chemistry. More specifically, CFM-ID 4.0 supports the: 1) prediction of electrospray ionization quadrupole time-of-flight tandem mass spectra (ESI-QTOF-MS/MS) for small molecules over multiple collision energies (10 eV, 20 eV, and 40 eV); 2) annotation of ESI-QTOF-MS/MS spectra given the structure of the compound; and 3) identification of a small molecule that generated a given ESI-QTOF-MS/MS spectrum at one or more collision energies. The CFM-ID 4.0 web server makes use of a substantially improved MS fragmentation algorithm, a much larger database of experimental and in silico predicted MS/MS spectra and improved scoring methods to offer more accurate MS/MS spectral prediction and MS/MS-based compound identification. Compared to earlier versions of CFM-ID, this new version has an MS/MS spectral prediction performance that is ~22% better and a compound identification accuracy that is ~35% better on a standard (CASMI 2016) testing dataset. CFM-ID 4.0 also features a neutral loss function that allows users to identify similar or substituent compounds where no match can be found using CFM-ID’s regular MS/MS-to-compound identification utility. Finally, the CFM-ID 4.0 web server now offers a much more refined user interface that is easier to use, supports molecular formula identification (from MS/MS data), provides more interactively viewable data (including proposed fragment ion structures) and displays MS mirror plots for comparing predicted with observed MS/MS spectra. These improvements should make CFM-ID 4.0 much more useful to the community and should make small molecule identification much easier, faster, and more accurate.

59 BASIC BIOLOGICAL SCIENCES↗

Incentivizing Distributed Energy Resource Participation in Grid Services

The bulk power system is experiencing a dramatic shift as renewable generation growth continues to accelerate. Large-scale renewables adoption will help societies transition to a low-carbon, low-cost, and environmentally friendly electrical power system. However, the transition from a paradigm of generation following load to one where load follows generation will require large-scale interconnection and coordinated operation of Distributed Energy Resources (DERs), supported by open communication protocols. In this future grid scenario, DER aggregations will provide critical grid services that enable high penetration levels of renewable generation. This position paper presents an Energy Service Interface (ESI) that defines scope for ensuring secure, trustworthy information exchange between grid service providers and DERs. The goal of the ESI is to encourage large-scale participation of DERs in order to provide grid services through dispatch of DER aggregations. This position paper also presents an open smart energy communications protocol that allows DERs to advertise their characteristics and participate in grid services, within constraints established by the ESI. The paper presents several monetization incentives that grid service providers could use to encourage large-scale DER participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guest Editorial

Energy Systems Integration (ESI) is the process of coordinating the operation and planning of energy systems across multiple pathways and/or geographical scales to deliver reliable, cost-effective energy services with minimal impact on the environment. Energy systems have evolved from individual systems with little or no dependencies into a complex set of integrated systems at scales that include customers, cities, and regions. This evolution has been driven by political, economic, and environmental objectives. As we try to meet the globally recognized imperative to reduce carbon emissions through the deployment of large renewable energy capacities while also maintaining reliability and competitiveness, flexible energy systems are required. This flexibility can be attained through integrating various systems: by physically linking energy vectors, namely electricity, heat, and fuels; by coordinating these vectors across other infrastructures, namely water, data, and transport; by institutionally coordinating energy markets; and, spatially, by increasing market footprint with granularity all the way down to the customer level. Smart grids and ESI are related, in particular, the coupling between electricity, consumers, data and transport. This special section focuses on the aspects of ESI where electricity is coupled to water, heat and fuels and where this coupling brings challenges and/or opportunities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State of Common Grid Services Definitions

This document is prepared as part of the Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) 2.5.2 project, whose goal is to develop and socialize a common set of grid service definitions relevant to grid-related interactions with distributed energy resources (DER: responsive generation, storage, and loads), and to advance the concept and requirements of the Energy Services Interface (ESI) to the point of launching related interface standards and guides that can be implemented in communication protocols and business process definitions. The notion of “grid services” is integral to the definition of an ESI because a key principle of the ESI is that it permits coordination between grid operators and DER facilities in a way that is service-oriented, with an understanding of performance expectations. This document reviews the current state of grid service definitions, including those actively used in the market today as well as new services that have been proposed for future implementation. The document describes grid services used in transmission as well as distribution systems. In defining grid services, this document also distinguishes between two fundamental concepts: an “operational objective” and a “grid service,” which describes a generator’s or customer’s expected physical performance in delivering power to or consuming power from the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Common Grid Services: Terms and Definitions Report

This document is prepared as part of the Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) 2.5.2 project, whose goal is to develop and socialize a common set of grid service definitions relevant to grid-related interactions with distributed energy resources (DER: responsive generation, storage, and loads) and to advance the concept and requirements of the Energy Services Interface (ESI) to the point of launching related interface standards and guides that can be implemented in communication protocols and business process definitions. The notion of grid services is associated with the definition of an ESI because a key principle of the ESI is that it permits coordination between grid operators and DER facilities in a way that is service-oriented with an understanding of performance expectations. The project investigated the current state of North American grid service definitions from various market operators and utilities, as well as the Federal Energy Regulatory Commission and the North American Electric Reliability Corporation, actively used today (Liu et al. 2022). This document builds on that work to propose terms and definitions for a set of grid service types that address operational objectives commonly found in power system operations. These grid service types derive from existing grid services used in bulk electric market operations, recognizing that each operational authority uses somewhat different names with variations on service performance parameters. Finding commonality at the wholesale or bulk system operation level will hopefully engender progress in seeking agreement on grid services for DER engagement at the distribution level in the emerging retail marketplace.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computational Methods for Modeling Electrospray Microdroplet Chemistry for Improved Quantitative Mass Spectrometry

This project aimed at enhancing the quantitative analysis capabilities of electrospray ionization mass spectrometry (ESI-MS) by developing advanced computational methods. The primary focus was to integrate continuum and molecular dynamics simulations to study the behavior of microdroplets in the ESI process, from formation to evaporation. Through this research, we sought to bridge significant length and time scales to provide a comprehensive understanding of how analyte concentrations evolve from bulk solutions into gas-phase ions. This understanding is crucial for addressing challenges such as ionization efficiency, solvent effects, and ion suppression, which currently limit the accuracy of quantitative ESI-MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low Cost Entry, Descent, and Landing (EDL) Instrumentation for Planetary Missions

Missions that involve traversing through a planetary atmosphere are unique opportunities that require elements of entry, descent, and landing (EDL). Many aspects of the EDL sequence are qualified using analysis and simulation due to the inability to conduct appropriate ground tests, however validating flight data are often lacking, especially for missions not involving Earth re-entry. NASA has made strategic decisions to collect EDL flight data in order to improve future mission designs. For example, MEDLI1 and EFT-1 gathered hypersonic pressure and in-depth temperature data in the thermal protection system (TPS). However, the ability to collect EDL flight data from the smaller competed missions, such as Discovery and New Frontiers, has been limited in part due to the Principal Investigator-managed cost-caps (PIMCC). The recent NASA decision to consider EDL instrumentation earlier in the mission design cycle led to the inclusion of a requirement in the Discovery 2014 Announcement of Opportunity which requires all missions that involve EDL to include an Engineering Science Investigation (ESI).2 The ESI would involve sensors for aerothermal environment and TPS; atmosphere, aerodynamics, and flight dynamics; atmospheric decelerator; and/or vehicle structure.3 The ESI activity would be funded outside of the PIMCC.

and Landing↗

Electrospray Ionization Mass Spectrometry

Electrospray Ionization (ESI) is a process whereby gas phase ions are created from molecules in solution. As a solution exits a narrow tube in the presence of a strong electric field, an aerosol of charged droplets are is formed that produces gas phase ions as they it desolvates. ESI-MS comprises the creation of ions by ESI and the determination of their mass to charge ratio (m/z) by MS.

Environmental Molecular Sciences Laboratory↗

Improving the Sensitivity of Mass Spectrometry by Using a New Sheath Flow Electrospray Emitter Array at Subambient Pressures

Arrays of chemically etched emitters with individualized sheath gas capillaries have been developed to enhance electrospray ionization (ESI) at subambient pressures. By including an emitter array in a subambient pressure ionization with nanoelectrospray (SPIN) source, ionization and transmission efficiency can be maximized allowing for increased sensitivity in mass spectrometric analyses. The SPIN source eliminates the major ion losses at conventional ESI-mass spectrometry (MS) interface by placing the emitter in the first vacuum region of the instrument. To facilitate stable electrospray currents in such conditions we have developed an improved emitter array with individualized sheath gas around each emitter. The utility of the new emitter arrays for generating stable multi-electrosprays at subambient pressures was probed by coupling the emitter array/SPIN source with a time of flight (TOF) mass spectrometer. The instrument sensitivity was compared between single emitter/SPIN-MS and multi-emitter/SPIN-MS configurations using an equimolar solution of 9 peptides. An increase in sensitivity correlative to the number of emitters in the array was observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Macrocycle-Directed Construction of Tetrahedral Anion-pi Receptors for Nesting Anions with Complementary Geometry

The unprecedented tetrahedral anion-? receptors have been successfully constructed by a macrocycle-directed approach. The use of large macrocycle precursors bearing four reaction sites enabled kinetic-favored cross-linking pathway and afforded otherwise-inaccessible tetrahedral cages in considerable yields. Crystal structure suggested that the tetrahedral cages have an enclosed three-dimensional cavity surrounded by four electron-deficient triazine faces in a tetrahedral array. The complementary accommodation of a series of tetrahedral and relevant anions including BF4-, ClO4-, H2PO4-, HSO4-, SO42- and PF6- has been observed by ESI-MS. Two complex crystal structures with ClO4- and PF6- demonstrated the anion was nicely encapsulated within the tetrahedral cavity through up to quadruple cooperative anion-? interactions by an excellent shape and size match. The favored complexation energies were established by DFT calculation and further confirmed by negative ion photoelectron spectroscopy study.

Luo, Jian↗

V IV O and V IV Species Formed in Aqueous Solution by the Tridentate Glutaroimide–Dioxime Ligand – An Instrumental and Computational Characterization

Complexation of V IV in aqueous solution with glutaroimide–dioxime (H 3 L), a ligand proposed for the possible sequestration of uranium from seawater, was studied by the combined application of spectroscopic (EPR and UV/Vis), spectrometric (ESI‐MS), electrochemical (CV), and computational (DFT) techniques. The results indicate that a rare non‐oxido V IV species, with formula [V IV L 2 ] 2– , is formed in the pH range 3–5. It transforms into a usual V IV O complex, [V IV OL(OH)] 2– , at pH > 6. The non‐oxido species is characterized by a “ type 3 ” EPR spectrum with A z ≈ 126 × 10 –4 cm –1 and a UV/Vis signal with ε > 2000 m –1 cm –1 in the visible region. The detection of V V species by ESI‐MS spectrometry was related to two possible oxidation processes, the first one in solution and the second one in‐source during the recording of the spectra. The cyclic voltammogram of [V IV L 2 ] 2– shows two quasi‐reversible processes, at E 1/2 = –0.75 V and E 1/2 = 0.03 V, assigned to the V IV /V III reduction and V IV /V V oxidation, respectively. All the experimental results were verified by DFT calculations, which indicated that the geometry of the non‐oxido V IV complex is intermediate between an octahedron and a trigonal prism and allowed us to predict its 51 V hyperfine coupling (HFC) tensor A , the electron absorption spectrum, the two redox processes in the cyclic voltammogram, and the electronic structure that, in turn, determines its EPR and UV/Vis behavior.

Sanna, Daniele↗