Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERROR CORRECTING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Improving Lidar Turbulence Estimates for Wind Energy

Remote sensing devices (e.g., lidars) are quickly becoming a cost-effective and reliable alternative to meteorological towers for wind energy applications. Although lidars can measure mean wind speeds accurately, these devices measure different values of turbulence intensity (TI) than an instrument on a tower. In response to these issues, a lidar TI error reduction model was recently developed for commercially available lidars. The TI error model first applies physics-based corrections to the lidar measurements, then uses machine-learning techniques to further reduce errors in lidar TI estimates. The model was tested at two sites in the Southern Plains where vertically profiling lidars were collocated with meteorological towers. This presentation primarily focuses on the physics-based corrections, which include corrections for instrument noise, volume averaging, and variance contamination. As different factors affect TI under different stability conditions, the combination of physical corrections applied in L-TERRA changes depending on the atmospheric stability during each 10-minute time period. This stability-dependent version of L-TERRA performed well at both sites, reducing TI error and bringing lidar TI estimates closer to estimates from instruments on towers. However, there is still scatter evident in the lidar TI estimates, indicating that there are physics that are not being captured in the current version of L-TERRA. Two options are discussed for modeling the remainder of the TI error physics in L-TERRA: machine learning and lidar simulations. Lidar simulations appear to be a better approach, as they can help improve understanding of atmospheric effects on TI error and do not require a large training data set.

17 WIND ENERGY↗

Suppression of quasiparticle poisoning in transmon qubits by gap engineering

The performance of various superconducting devices operating at ultra-low temperatures is impaired by the presence of non-equilibrium quasiparticles. Inelastic quasiparticle (QP) tunneling across Josephson junctions in superconducting qubits results in decoherence and spurious excitations and, notably, can trigger correlated errors that severely impede quantum error correction. In this work, we use "gap engineering" to suppress the tunneling of low-energy quasiparticles in Al-based transmon qubits, a leading building block for superconducting quantum processors. By implementing potential barriers for QP, we strongly suppress QP tunneling across the junction and preserve charge parity for over $10^3$ seconds. The suppression of QP tunneling also results in a reduction in the qubit energy relaxation rates. The demonstrated approach to gap engineering can be easily implemented in all Al-based circuits with Josephson junctions.

Kamenov, Plamen↗

Test results of an ITER relevant FPGA when irradiated with neutrons

The data acquisition and control instrumentation cubicles room of the ITER tokamak will be irradiated with neutrons during the fusion reactor operation. A Virtex-6 FPGA from Xilinx (XC6VLX365T-1FFG1156C) is used on the ATCA-IO-PROCESSOR board, included in the ITER Catalog of I and C products - Fast Controllers. The Virtex-6 is a re-programmable logic device where the configuration is stored in Static RAM (SRAM), functional data stored in dedicated Block RAM (BRAM) and functional state logic in Flip-Flops. Single Event Upsets (SEU) due to the ionizing radiation of neutrons causes soft errors, unintended changes (bit-flips) to the values stored in state elements of the FPGA. The SEU monitoring and soft errors repairing, when possible, were explored in this work. An FPGA built-in Soft Error Mitigation (SEM) controller detects and corrects soft errors in the FPGA configuration memory. Novel SEU sensors with Error Correction Code (ECC) detect and repair the BRAM memories. Proper management of SEU can increase reliability and availability of control instrumentation hardware for nuclear applications. The results of the tests performed using the SEM controller and the BRAM SEU sensors are presented for a Virtex-6 FPGA (XC6VLX240T-1FFG1156C) when irradiated with neutrons from the Portuguese Research Reactor (RPI), a 1 MW nuclear fission reactor operated by IST in the neighborhood of Lisbon. Results show that the proposed SEU mitigation technique is able to repair the majority of the detected SEU errors in the configuration and BRAM memories. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Practical Introduction to Benchmarking and Characterization of Quantum Computers

Rapid progress in quantum technology has transformed quantum computing and quantum information science from theoretical possibilities into tangible engineering challenges. Breakthroughs in quantum algorithms, quantum simulations, and quantum error correction are bringing useful quantum computation closer to fruition. These remarkable achievements have been facilitated by advances in quantum characterization, verification, and validation (QCVV). QCVV methods and protocols enable scientists and engineers to scrutinize, understand, and enhance the performance of quantum information-processing devices. In this tutorial, we review the fundamental principles underpinning QCVV, and introduce a diverse array of QCVV tools used by quantum researchers. We define and explain QCVV’s core models and concepts—quantum states, measurements, and processes—and illustrate how these building blocks are leveraged to examine a target system or operation. We survey and introduce protocols ranging from simple qubit characterization to advanced benchmarking methods. Along the way, we provide illustrated examples and detailed descriptions of the protocols, highlight the advantages and disadvantages of each, and discuss their potential scalability to future large-scale quantum computers. This tutorial serves as a guidebook for researchers unfamiliar with the benchmarking and characterization of quantum computers, and also as a detailed reference for experienced practitioners.

open quantum systems & decoherence↗

Calibration of time-of-flight cameras for accurate intraoperative surface reconstruction

Purpose: In image-guided surgery (IGS) intraoperative image acquisition of tissue shape, motion, and morphology is one of the main challenges. Recently, time-of-flight (ToF) cameras have emerged as a new means for fast range image acquisition that can be used for multimodal registration of the patient anatomy during surgery. The major drawbacks of ToF cameras are systematic errors in the image acquisition technique that compromise the quality of the measured range images. In this paper, we propose a calibration concept that, for the first time, accounts for all known systematic errors affecting the quality of ToF range images. Laboratory and in vitro experiments assess its performance in the context of IGS.Methods: For calibration the camera-related error sources depending on the sensor, the sensor temperature and the set integration time are corrected first, followed by the scene-specific errors, which are modeled as function of the measured distance, the amplitude and the radial distance to the principal point of the camera. Accounting for the high accuracy demands in IGS, we use a custom-made calibration device to provide reference distance data, the cameras are calibrated too. To evaluate the mitigation of the error, the remaining residual error after ToF depth calibration was compared with that arising from using the manufacturer routines for several state-of-the-art ToF cameras. The accuracy of reconstructed ToF surfaces was investigated after multimodal registration with computed tomography (CT) data of liver models by assessment of the target registration error (TRE) of markers introduced in the livers.Results: For the inspected distance range of up to 2 m, our calibration approach yielded a mean residual error to reference data ranging from 1.5 ± 4.3 mm for the best camera to 7.2 ± 11.0 mm. When compared to the data obtained from the manufacturer routines, the residual error was reduced by at least 78% from worst calibration result to most accurate manufacturer data. After registration of the CT data with the ToF data, the mean TRE ranged from 3.7 ± 2.1 mm for point-based and 5.7 ± 1.9 mm for surface-based registration for the best camera to 6.2 ± 3.4 and 11.1 ± 2.8 mm, respectively. Compared to data provided by the manufacturer, the mean TRE decreased by 8%–60% for point-based and by 18%–74% for surface-based registration.Conclusions: Using the proposed calibration approach improved the measurement accuracy of all investigated ToF cameras. Although evaluated in the context of intraoperative image acquisition, the proposed calibration procedure can easily be applied to other medical applications using ToF cameras, such as patient positioning or respiratory motion tracking in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analyzing the effectiveness of a frame-level redundancy scrubbing technique for SRAM-based FPGAs

Radiation effects such as soft errors are the major threat to the reliability of SRAM-based FPGAs. This work analyzes the effectiveness in correcting soft errors of a novel scrubbing technique using internal frame redundancy called Frame-level Redundancy Scrubbing (FLR-scrubbing). This correction technique can be implemented in a coarse grain TMR design. The FLR-scrubbing technique was implemented on a mid-size Xilinx Virtex-5 FPGA device used as a case study. The FLR-scrubbing technique was tested under neutron radiation and fault injection. Implementation results demonstrated minimum area and energy consumption overhead when compared to other techniques. The time to repair the fault is also improved by using the Internal Configuration Access Port (ICAP). Lastly, neutron radiation test results demonstrated that the proposed technique is suitable for correcting accumulated SEUs and MBUs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cherenkov Video Imaging Allows for the First Visualization of Radiation Therapy in Real Time

Purpose: To determine whether Cherenkov light imaging can visualize radiation therapy in real time during breast radiation therapy. Methods and Materials: An intensified charge-coupled device (CCD) camera was synchronized to the 3.25-μs radiation pulses of the clinical linear accelerator with the intensifier set × 100. Cherenkov images were acquired continuously (2.8 frames/s) during fractionated whole breast irradiation with each frame an accumulation of 100 radiation pulses (approximately 5 monitor units). Results: The first patient images ever created are used to illustrate that Cherenkov emission can be visualized as a video during conditions typical for breast radiation therapy, even with complex treatment plans, mixed energies, and modulated treatment fields. Images were generated correlating to the superficial dose received by the patient and potentially the location of the resulting skin reactions. Major blood vessels are visible in the image, providing the potential to use these as biological landmarks for improved geometric accuracy. The potential for this system to detect radiation therapy misadministrations, which can result from hardware malfunction or patient positioning setup errors during individual fractions, is shown. Conclusions: Cherenkoscopy is a unique method for visualizing surface dose resulting in real-time quality control. We propose that this system could detect radiation therapy errors in everyday clinical practice at a time when these errors can be corrected to result in improved safety and quality of radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrating Symbolic and Statistical Methods for Testing Intelligent Systems Applications to Machine Learning and Computer Vision

Embedded intelligent systems ranging from tiny im- plantable biomedical devices to large swarms of autonomous un- manned aerial systems are becoming pervasive in our daily lives. While we depend on the flawless functioning of such intelligent systems, and often take their behavioral correctness and safety for granted, it is notoriously difficult to generate test cases that expose subtle errors in the implementations of machine learning algorithms. Hence, the validation of intelligent systems is usually achieved by studying their behavior on representative data sets, using methods such as cross-validation and bootstrapping.In this paper, we present a new testing methodology for studying the correctness of intelligent systems. Our approach uses symbolic decision procedures coupled with statistical hypothesis testing to. We also use our algorithm to analyze the robustness of a human detection algorithm built using the OpenCV open-source computer vision library. We show that the human detection implementation can fail to detect humans in perturbed video frames even when the perturbations are so small that the corresponding frames look identical to the naked eye.

Jha, Sumit Kumar↗

Cryogenic-Refined MOSFET Modeling for Oscillator, Frequency Divider, and Amplifier Designs Below 4 K

Capturing device characteristic changes at cryogenic temperatures is crucial for cryo-CMOS circuit designs. In this work, we present an isothermal cryogenic-refined modeling approach for CMOS transistors that is simple, low overhead, and easy to implement while offering the required accuracy for predicting circuit performance at the designated temperatures. Guided by die-level measurement data and circuit design principles, the model introduces corrections to only five critical parameters: threshold voltage, carrier mobility, elevated low-frequency flicker noise, dominant high-frequency shot noise, and subthreshold swing (SS). These refinements are implemented around the foundry-provided SPICE model, which is typically validated only down to about 200 K. With these adjustments, the proposed cryogenic-refined model achieves less than 5% error in both large-signal metrics (I–V characteristics) and small-signal parameters (e.g., transconductance) when compared with device measurements at deep-cryogenic temperatures. The methodology is validated in two advanced technologies: TSMC 40-nm CMOS and GlobalFoundries (GF) 45-nm RF-SOI. We further demonstrate its applicability in three representative RF circuits: a 30-GHz LC oscillator, a high-speed current-mode-logic (CML) frequency divider (FD), and a subthreshold Gb/s amplifier, all showing close agreement between simulated predictions and measurements performed at 4 and 2.5 K. Finally, we believe that the proposed approach is implementation-friendly and can significantly accelerate the development of cryo-CMOS integrated circuits.

circuit modeling↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the scaling limitations of the variational quantum eigensolver with the bond dissociation of hydride diatomic molecules

Abstract Materials simulations involving strongly correlated electrons pose fundamental challenges to state‐of‐the‐art electronic structure methods but are hypothesized to be the ideal use case for quantum computing algorithms. To date, no quantum computer has simulated a molecule of a size and complexity relevant to real‐world applications, despite the fact that the variational quantum eigensolver (VQE) algorithm can predict chemically accurate total energies. Nevertheless, because of the many applications of moderately sized, strongly correlated systems, such as molecular catalysts, the successful use of the VQE stands as an important waypoint in the advancement toward useful chemical modeling on near‐term quantum processors. In this paper, we take a significant step in this direction. We lay out the steps, write, and run parallel code for an (emulated) quantum computer to compute the bond dissociation curves of the TiH, LiH, NaH, and KH diatomic hydride molecules using the VQE. TiH was chosen as a relatively simple chemical system that incorporates d orbitals and strong electron correlation. Because current VQE implementations on existing quantum hardware are limited by qubit error rates, the number of qubits available, and the allowable gate depth, recent studies using it have focused on chemical systems involving s and p block elements. Through VQE + UCCSD calculations of TiH, we evaluate the near‐term feasibility of modeling a molecule with d‐orbitals on real quantum hardware. We demonstrate that the inclusion of d‐orbitals and the use of the UCCSD ansatz, which are both necessary to capture the correct TiH physics, dramatically increase the cost of this problem. We estimate the approximate error rates necessary to model TiH on current quantum computing hardware using VQE + UCCSD and show them to likely be prohibitive until significant improvements in hardware and error correction algorithms are available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive optical correction for in vivo two-photon fluorescence microscopy with neural fields

Adaptive optics restore ideal imaging performance in complex samples by measuring and correcting optical aberrations but often require custom-built microscopes with carefully aligned wavefront sensing/shaping devices and can be susceptible to sample motion. Here we describe NeAT, a computational framework using neural fields for adaptive optics two-photon fluorescence microscopy. NeAT estimates wavefront aberration and recovers sample structure from a 3D image stack without requiring external datasets for training. Incorporating motion correction in learning and correcting conjugation errors commonly found in commercial microscopes, NeAT is designed for deployment in biological laboratories for in vivo imaging. We validate NeAT’s performance using a custom-built microscope with a wavefront sensor under varying signal-to-noise ratios, aberration and motion conditions. With a commercial microscope, we demonstrate real-time aberration correction for in vivo morphological and functional imaging in the living mouse brain, with NeAT improving the signal and accuracy of glutamate and calcium imaging of synapses and neurons.

Kang, Iksung↗

Measuring the angular momentum of a neutron using Earth's rotation

A coupling between Earth's rotation and orbital angular momentum (OAM), known as the Sagnac effect, is observed in entangled neutrons produced using a spin-echo interferometer. After correction for instrument systematics the measured coupling is within 5% of theory, with an uncertainty of 7.2%. The OAM in our setup is transverse to the propagation direction and scales linearly with neutron wavelength (4–12.75 Å), so the Sagnac coupling can be varied without mechanically rotating the device, which avoids systematic errors present in previous experiments. The detected transverse OAM of our beam corresponds to 4098 ± 295 ℏ Å − 1 , 10 5 times lower than in the previous neutron experiments. This demonstrates the feasibility of using the Sagnac effect to definitively measure neutron OAM and paves the way towards a future observation of the quantum Sagnac effect. Published by the American Physical Society 2025

Geerits, Niels (ORCID:0000000248072084)↗

Source position verification and dosimetry in HDR brachytherapy using an EPID

Purpose: Accurate treatment delivery in high dose rate (HDR) brachytherapy requires correct source dwell positions and dwell times to be administered relative to each other and to the surrounding anatomy. Treatment delivery inaccuracies predominantly occur for two reasons: (i) anatomical movement or (ii) as a result of human errors that are usually related to incorrect implementation of the planned treatment. Electronic portal imaging devices (EPIDs) were originally developed for patient position verification in external beam radiotherapy and their application has been extended to provide dosimetric information. The authors have characterized the response of an EPID for use with an {sup 192}Ir brachytherapy source to demonstrate its use as a verification device, providing both source position and dosimetric information.Methods: Characterization of the EPID response using an {sup 192}Ir brachytherapy source included investigations of reproducibility, linearity with dose rate, photon energy dependence, and charge build-up effects associated with exposure time and image acquisition time. Source position resolution in three dimensions was determined. To illustrate treatment verification, a simple treatment plan was delivered to a phantom and the measured EPID dose distribution compared with the planned dose.Results: The mean absolute source position error in the plane parallel to the EPID, for dwells measured at 50, 100, and 150 mm source to detector distances (SDD), was determined to be 0.26 mm. The resolution of the z coordinate (perpendicular distance from detector plane) is SDD dependent with 95% confidence intervals of ±0.1, ±0.5, and ±2.0 mm at SDDs of 50, 100, and 150 mm, respectively. The response of the EPID is highly linear to dose rate. The EPID exhibits an over-response to low energy incident photons and this nonlinearity is incorporated into the dose calibration procedure. A distance (spectral) dependent dose rate calibration procedure has been developed. The difference between measured and planned dose is less than 2% for 98.0% of pixels in a two-dimensional plane at an SDD of 100 mm.Conclusions: Our application of EPID dosimetry to HDR brachytherapy provides a quality assurance measure of the geometrical distribution of the delivered dose as well as the source positions, which is not possible with any current HDR brachytherapy verification system.

61 RADIATION PROTECTION AND DOSIMETRY↗

QIS for Applied Quantum Field Theory

Precision predictions in HEP and non-equilibrium dynamics in the early universe require quantum computational technologies. Future quantum devices offer the possibility of performing these, complementing lattice quantum chromodynamics (QCD) studies on classical computers. We are investigating many aspects of the quantum simulation of quantum field theories. Specific topics include simulation-suitable formulations of gauge theories, state preparation, time evolution, extracting HEP-related observables from simulations, quantum error correction (QEC), and entanglement. We are exploring strategies for simulation of scattering in QFTs, and dynamics of the early Universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Logical error rates for the surface code under a mixed coherent and stochastic circuit-level noise model inspired by trapped ions

With fault-tolerant quantum computing (FTQC) on the horizon, it is critical to understand sources of logical errors in plausible hardware implementations of quantum error-correcting codes. Detailed error modeling of computational instructions on particular FTQC architectures will enable the better prediction of error propagation in FT-encoded quantum circuits while revealing where greater attention is needed in hardware design. In this work, we consider logical error rates for the surface code implemented on a hypothetical grid-based trapped-ion quantum charge-coupled device architecture. Specifically, we construct logical channels for the idling surface code and examine its diamond error under a mixed coherent and stochastic circuit-level noise model inspired by trapped ions. We include the coherent dephasing noise that is known to accumulate during physical qubit idling and transport in these systems, determining idling and transport durations using the time-resolved output of an open-source trapped-ion surface code compiler. To estimate expectation values of logical Pauli observables following hardware circuits containing non-Clifford sources of noise, we utilize a Monte Carlo technique to sample from an underlying quasiprobability distribution of Clifford circuits that we independently simulate in a phase-sensitive fashion. We verify error suppression up to code distance 𝑑 = 11 at coherent dephasing rates near and below those of current-generation trapped-ion quantum computers and find that logical error rates align with those of analogous fully stochastic simulations in this regime. Exploring higher dephasing rates at 𝑑 = 3−5, we find evidence for growing coherent rotations about all three logical Pauli axes, increased diagonal logical error process matrix elements relative to those of stochastic simulations, and a reduced dephasing rate threshold. Overall, our work paves a way toward realistic hardware emulation of small fault-tolerant quantum processes, e.g., members of an FTQC instruction set.

Quantum benchmarking↗

Practical quantum computation of chemical and nuclear energy levels using quantum imaginary time evolution and Lanczos algorithms

Various methods have been developed for the quantum computation of the ground and excited states of physical and chemical systems, but many of them require either large numbers of ancilla qubits or high-dimensional optimization in the presence of noise. The quantum imaginary-time evolution (QITE) and quantum Lanczos (QLanczos) methods proposed in Motta et al. (2020) eschew the aforementioned issues. In this study, we demonstrate the practical application of these algorithms to challenging quantum computations of relevance for chemistry and nuclear physics, using the deuteron-binding energy and molecular hydrogen binding and excited state energies as examples. With the correct choice of initial and final states, we show that the number of timesteps in QITE and QLanczos can be reduced significantly, which commensurately simplifies the required quantum circuit and improves compatibility with NISQ devices. We have performed these calculations on cloud-accessible IBM Q quantum computers. With the application of readout-error mitigation and Richardson error extrapolation, we have obtained ground and excited state energies that agree well with exact results obtained from diagonalization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction to: Superconductor Electronics: Status and Outlook

The original version of the article unfortunately contained errors. The acronyms for conventional Josephson voltage standard (CJVS) and programmable Josephson voltage standard (PJVS) were misspelled as CVJC, PJVC and PVJC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗