Engineering PapersSearch

SEARCH · Engineering Papers

Results for “ENERGY STORAGE DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

343 records · Page 5

A 65 Ah rechargeable lithium molybdenum disulfide battery

A rechargeable lithium molybdenum disulfide battery which has a number of superior performance characteristics which includes a high energy density, a high power density, and a long charge retention time was developed. The first cell sizes developed included a C size cell and an AA size cell. Over the last two years, a project to demonstrate the feasibility of the scale up to this technology to a BC size cell with 65 Ah capacity was undertaken. The objective was to develop, build, and test a .6 kWh storage battery consisting of 6 BC cells in series.

Brandt, K.

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain

Center for High-Efficiency Electrical Technologies for Aircraft: Phase I Final Report

Under the University Leadership Initiative (ULI), the Center for High-Efficiency for Electrical Technologies (CHEETA) was established to develop and mature early-stage technologies pertaining to hydrogen-electric power and energy systems for aircraft. In particular, integration of these technologies on an aircraft system is envisioned to leverage the high specific energy content of liquid hydrogen (LH2) with fuel cell energy conversion and an electrically driven ducted fan system to provide an ultra-efficient propulsion drivetrain. For this concept, the LH2 system is not just used as an energy storage mechanism, but also as a cryogen to enable highly efficient superconducting electric systems. The end result of this concept is an integrated aircraft system with a quiet, efficient propulsion architecture that produces zero CO2, NOx, SOx, and particulate matter emissions at the vehicle level.

Hydrogen

Research and development of high thermal stability fuels

Increases in aircraft performance are leading to increases in the thermal stress on the primary aircraft coolant--the fuel. Fuel thermal stability limitations may offset future aircraft performance gains. The Air Force's Wright Laboratory is sponsoring several research programs to address this problem. The development of an additive package for JP-8 to improve its thermal stability is the primary focus of this paper. This program involves extensive testing of fuels and additives in a variety of test devices, culminating in tests in a fuel system simulator and engine tests. These tests involve Air Force personnel, on-site contractors (University of Dayton Research Institute, Systems Research Laboratories), Pratt and Whitney Aircraft Co., additive manufacturers, and Sandia National Laboratory. The test devices include several flowing and static tests, where the behavior of a fuel is investigated in a wide variety of environments. The study of several baseline fuels in these devices has led to some new insights into the mechanisms of fuel thermal (in)stability. It is becoming clear that a fuel's tendency to oxidize (to form peroxides, for example) is often inversely proportional to its tendency to form insoluble deposits.

T Edwards

A computerized aircraft battery servicing facility

The latest upgrade to the Aerospace Energy Systems Laboratory (AESL) is described. The AESL is a distributed digital system consisting of a central system and battery servicing stations connected by a high-speed serial data bus. The entire system is located in two adjoining rooms; the bus length is approximately 100 ft. Each battery station contains a digital processor, data acquisition, floppy diskette data storage, and operator interfaces. The operator initiates a servicing task and thereafter the battery station monitors the progress of the task and terminates it at the appropriate time. The central system provides data archives, manages the data bus, and provides a timeshare interface for multiple users. The system also hosts software production tools for the battery stations and the central system.

Glover, Richard D.

A battery simulator

Simulator verifies proper operation of a battery cell voltage-monitoring device. It also contains variable ac voltage to ascertain that a battery scanner will perform its function at all possible ac voltages.

Ferrell, S., Jr.

Improved silver-zinc battery-terminal seals

Development of battery terminal seal for sealing electrolyte for periods of three to five years is discussed. Operating conditions of battery are defined. Components of electrolyte seal and method of production are reported. Schematic diagrams of device are included.

Snider, W. E.

Chemically rechargeable battery

Batteries (50) containing oxidized, discharged metal electrodes such as an iron-air battery are charged by removing and storing electrolyte in a reservoir (98), pumping fluid reductant such as formalin (aqueous formaldehyde) from a storage tank (106) into the battery in contact with the surfaces of the electrodes. After sufficient iron hydroxide has been reduced to iron, the spent reductant is drained, the electrodes rinsed with water from rinse tank (102) and then the electrolyte in the reservoir (106) is returned to the battery. The battery can be slowly electrically charged when in overnight storage but can be quickly charged in about 10 minutes by the chemical procedure of the invention.

Graf, James E.

Battery selection for space experiments

This paper will delineate the criteria required for the selection of batteries as a power source for space experiments. Four basic types of batteries will be explored, lead acid, silver zinc, alkaline manganese and nickel cadmium. A detailed description of the lead acid and silver zinc cells while a brief exploration of the alkaline manganese and nickel cadmium will be given. The factors involved in battery selection such as packaging, energy density, discharge voltage regulation, and cost will be thoroughly examined. The pros and cons of each battery type will be explored. Actual laboratory test data acquired for the lead acid and silver zinc cell will be discussed. This data will include discharging under various temperature conditions, after three months of storage and with different types of loads. A description of the required maintenance for each type of battery will be investigated. The lifetime and number of charge/discharge cycles will be discussed.

Francisco, David R.

Space Station battery system design and development

The Space Station Electric Power System will rely on nickel-hydrogen batteries in its photovoltaic power subsystem for energy storage to support eclipse and contingency operations. These 81-Ah batteries will be designed for a 5-year life capability and are configured as orbital replaceable units (ORUs), permitting replacement of worn-out batteries over the anticipated 30-year Station life. This paper describes the baseline design and the development plans for the battery assemblies, the battery ORUs and the battery system. Key elements reviewed are the cells, mechanical and thermal design of the assembly, the ORU approach and interfaces, and the electrical design of the battery system. The anticipated operational approach is discussed, covering expected performance as well as the processor-controlled charge management and discharge load allocation techniques. Development plans cover verification of materials, cells, assemblies and ORUs, as well as system-level test and analyses.

Haas, R. J.

Battery charge regulator is coulometer controlled

Coulometer controlled battery charge regulator controls nickel/cadmium type primary cells used in space applications. The use of the coulometer as an ampere hour measuring device permits all available current to go to the battery until full charge state is reached, at which time the charge rate is automatically reduced.

Paulkovich, J.

Lithium Ion Battery Design and Safety

This viewgraph presentation makes several recommendations to ensure the safe and effective design of Lithium ion cell batteries. Large lithium ion cells require pressure switches and small cells require pressure disconnects and other safety devices with the ability to instantly interrupt flow. Other suggestions include specifications for batteries and battery chargers.

Au, George

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Change Material Heat Capacitor

A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft’s propylene glycol-water mixture coolant system. Testing was performed with the phase change material contained under sealed conditions after a degassing procedure and exposed to atmosphere without prior degassing. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements and theoretical N-Pentadecane storage capacity.

Propylene Glycol Water