Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EMT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electromagnetic Transient (EMT) Simulation Algorithms for Evaluation of Large-Scale Extreme Fast Charging Systems (T&D Models)

Simulation of high-fidelity models of extreme fast charging (XFC) systems and large-area power grids with many XFCs can be time consuming in traditional simulators. Traditional simulators use a single method of discretization for all the components that results in imposing a large computational burden of inverting a large matrix as well as increased computations related to single method of discretization (that is typically a trapezoidal method). To overcome the problem of simulating large-area power grids with many XFCs, in this paper, advanced numerical simulation algorithms are applied for the first time together to reduce the dimension of matrix inversion. Here, the algorithms include numerical stiffness-based segregation, time constant-based segregation, clustering and aggregation on differential algebraic equations (DAEs), and multi-order integration approaches. These algorithms apply multiple discretization algorithms rather than a single discretization algorithm that further reduces the computational burden. The approaches mentioned here have resulted in speed-up of up to 18x in the simulation of a single distribution system with 15 XFCs and of up to 271x in the simulation of a transmission-distribution system with 300 XFCs in multiple distribution feeders with respect to conventional simulators (like power systems computer aided design [PSCAD]).

42 ENGINEERING↗

Ubiquitin-specific peptidase 39 regulates the process of proliferation and migration of human ovarian cancer via p53/p21 pathway and EMT

Ovarian cancer is one of the most lethal gynecological cancers; owning to its late detection and chemoresistance, understanding the pathogenesis of this malignant tumor is much critical. Previous studies have reported that ubiquitin-specific peptidase 39 (USP39) is generally overexpressed in a variety of cancers, including hepatocellular carcinoma, gastric cancer and so forth. Furthermore, USP39 is proved to be associated with the proliferation of malignant tumors. However, the function and mechanism of USP39 in ovarian cancer have not been elucidated. In the present study, we observed that USP39 was frequently overexpressed in human ovarian cancer and was highly correlated with TNM stage. Suppression of USP39 markedly inhibited the growth and migration of ovarian cancer cell lines HO-8910 and SKOV3 and induced cell cycle G2/M arrest. Moreover, knockdown of USP39 inhibited ovarian tumor growth in a xenograft model. In addition, our findings indicated that cell cycle arrest induced by USP39 knockdown might be involved in p53/p21 signaling pathway. Furthermore, we found that the depletion of USP39 inhibited the migration of ovarian cancer cells via blocking epithelial–mesenchymal transition. Taken together, these results suggest that USP39 may play vital roles in the genesis and progression and may serve as a potential biomarker for diagnosis and therapeutic target of ovarian cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long noncoding RNA LINC00165-induced by STAT3 exerts oncogenic properties via interaction with Polycomb Repressive Complex 2 to promote EMT in gastric cancer

Long non-coding RNAs (lncRNAs) are a crucial member of the non-coding RNA family, and increasing evidence demonstrates that lncRNAs participate in the initiation and progression of cancers. Our study aimed to explore the role of the lncRNA LINC00165 in gastric cancer (GC) development. In the present study, our results showed that LINC00165 was upregulated in GC tissues and cell lines and high expression of LINC00165 was correlated with tumor-node-metastasis stage, invasion depth, and overall survival of GC patients. Functional assays showed that LINC00165 knockdown inhibited the proliferation, migration and invasion of GC cells and LINC00165 overexpression stimulated their proliferation, migration and invasion. Online transcription factor binding site prediction analysis showed that there were STAT3 binding sites in the LINC00165 promoter region. Furthermore, luciferase reporter and chromatin immunoprecipitation assays provided evidence that STAT3 could bind directly to the region between −547 bp to −537 bp (ATGTTGGGAAA) of LINC00165 promoter and activate its transcription. Then GC cells were partitioned into nuclear and cytoplasmic fractions and we found that LINC00165 was localized preferentially to the nucleus. Mechanistically, we revealed that LINC00165 functioned as a scaffold for interaction with Polycomb Repressive Complex 2 to promote the epithelial-mesenchymal transition in GC cells. Taken together, our study revealed that LINC00165 was involved in the progression and poor prognosis of GC as an oncogenic role. Therefore, LINC00165 might become a new potential target for GC chemotherapy and further predict prognosis of patients.

60 APPLIED LIFE SCIENCES↗

Analyzing impact of $\mathrm{DER}$ on $\mathrm{FIDVR}$ - comparison of $\mathrm{EMT}$ simulation of a combined transmission and distribution grid with aggregated positive sequence models

The increase in percentage of distributed energy resources (DERs) brings in a degree of uncertainty in bulk power system planning and operations. Further, the presence of 1 - φ induction motors introduces the possibility of motor stalling and fault induced delayed voltage recovery (FIDVR). With newer versions of IEEE Std 1547™ there can be the opportunity to obtain dynamic voltage support from DERs. In this report, the impact of DERs providing dynamic voltage on the dynamic behavior of 1 - φ induction motors is examined in detail along with an exploration of the need for simulation platforms that go beyond positive sequence. The studies discussed here are carried out both in detailed electromagnetic time domain and in positive sequence domain for comparison.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The EMT-related transcription factor snail up-regulates FAPα in malignant melanoma cells

Highlights: • The study finds a different regulation mechanism on FAPα expression. • Snail up-regulates expression of FAPα in malignant melanoma cells. • Snail binds to E-box in FAPα promoter to regulate FAPα expression. • Snail expression is positively correlated to FAPα expression in human cutaneous malignant melanoma. FAPα is a cell surface serine protease, mainly expressed in tumor stromal fibroblasts in more than 90% of human epithelial carcinomas. Due to its almost no expression in normal tissues and its tumor-promoting effects, FAPα has been studied as a novel potential target for antitumor therapy. However, the regulation mechanism on FAPα expression is poorly understood. In this study, we found that overexpression of snail significantly increased the mRNA and protein expression levels of FAPα in malignant melanoma B16 and SK-MEL-28 cells. Overexpression of snail increased FAPα promoter activity remarkably. Snail could directly bind to FAPα promoter to regulate FAPα expression. Moreover, snail expression was positively correlated to FAPα expression in human cutaneous malignant melanoma. Furthermore, knockdown of FAPα markedly reduced snail-induced cell migration. Overall, our findings provide a novel regulation mechanism on FAPα expression and highlight the role of snail/FAPα axis as a novel target for melanoma treatment.

60 APPLIED LIFE SCIENCES↗

Interpolation Methods to Enable Fast and Accurate EMT Simulation of PV Inverters

In this paper, interpolation methods to enable fast simulation of photovoltaic (PV) inverters are proposed. The interpolation methods are based on the event-driven interpolating method that can be introduced in the simulation model to run the model at a higher timestep while maintaining accuracy. The proposed methods are tested on a neutral point clamp (NPC) converter and a two-level converter (2LC) that are typically used in large-scale PV plants. The interpolation methods are integrated into the NPC and 2LC simulation models in PSCAD/Fortran and RSCAD C platforms. These models are tested at different simulation timesteps in off-line and real-time simulation platforms PSCAD and RSCAD respectively.

Marthi, Phani Ratna Vanamali↗

High-Fidelity Models and Fast EMT Simulation Algorithms for Isolated Multi-port Autonomous Reconfigurable Solar power plant (MARS)

The integration of hybrid photovoltaic (PV) and energy storage system (ESS) based plants has become a promising way of solving the intermittency of PV plants and providing frequency support to the power grid. The multi-port autonomous reconfigurable solar power plant (MARS) can integrate the PV systems and ESSs to an ac grid and dc lines. The proposed isolated MARS incorporates an isolated converter that connects to the PV arrays and is based on the dual active bridge (DAB) converter. The high frequency switching in the DAB and the means to control the DAB converter using delays between switching signals lead to the need for a small timestep in simulations. Moreover, several hundreds of modules that include a DAB converter are present in the MARS. The small timestep and the presence of several hundreds of modules lead to a significant rise in the overall simulation time. To address this issue, simulation algorithms like numerical stiffness-based hybrid discretization and the hysteresis relaxation technique are applied to the switched system model of isolated MARS. Additionally, an event-driven interpolating method is introduced to help increase the minimum timestep to simulate the conventional DAB converter model while maintaining high accuracy in the simulation results. The developed model is validated by comparison with its reference model built in the PSCAD/EMTDC and MATLAB software environments using library components.

Xia, Qian↗

Validation of the Fault Ride-Through Response of a Generic EMT Inverter Model by Laboratory Testing

This paper presents the validation of the fault ride-through response of a large-scale inverter model using laboratory testing of a commercial inverter. First, we present the generic inverter model specifications. The generic inverter control is developed based on the fault ride-through response performance requirements of IEEE Std 2800-2022 for inverter-based resources. Next, we present laboratory tests that emulate voltages at the inverter terminal resulting from balanced and unbalanced faults on the transmission system. The tests are performed on a commercia12.2 MVA battery storage inverter at the U.S. National Renewable Energy Laboratory. Comparisons of the model's response to the laboratory measurements show the generic model presented can predict the controlled response of the commercial equipment. The differences between the model's response and the laboratory measurements during the initial transient at fault inception are discussed.

fault ride-through↗

EMT Workshop 2026

These are files for the 2026 workshop edition of the

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

Landsat-7 EMT+ On-Orbit Radiometric Calibration

Landsat-7 was launched on April 15, 1999 and completed its on orbit initialization and verification period on June 28, 1999. The ETM+ payload is similar to the TM sensors on previous Landsat satellites and incorporates two new devices to improve its absolute radiometric calibration. The Full Aperture Solar Calibrator (FASC) is a deployable diffuser panel. This device has been deployed 9 times to date, with a normal deployment schedule of once per month. The initial analysis of the FASC data has given absolute calibration results within 5% of the prelaunch integrating sphere calibrations and a range of variation of 2% between dates. The Partial Aperture Solar Calibrator (PASC), is a set of auxiliary optics that allows the ETM+ to view the sun through a reduced aperture. Data have normally been acquired on a daily basis with the PASC. Initial results with the PASC were encouraging, despite some unexpected saturation in the shortest wavelength band. The response of the ETM+ short wavelength (silicon) bands to the PASC increased initially and has begun to decrease in some of these bands. The longer wavelength (InSb) bands have shown up to 30% oscillations that vary between detectors within the band. Studies are ongoing to better characterize the response to the PASC. The ETM+ also incorporates an internal calibrator (IC), a shutter that oscillates in front of the focal plane that directs light from the internal calibrator lamps to the focal plane. The responses to this device are also varying, though differently than the PASC results. Both the IC and PASC results are attributable to the calibration devices as opposed to the ETM+ itself.

Markham, Brian L.↗

EMT Project History and Overview

This is a slide set that is part of the 2021 ETM Workshop's planned technical presentations. The content of the presentation is intended to first provide an introduction to the impetus and background that led to ETM and the identified challenges that needed to be considered. Following the introduction, a presentation of early engagement with Industry and other government agencies is provided. The presentation concludes with the early work that followed engagement and the eventual project that ETM was integrated with as well as the eventual formulation of a joint NASA-FAA Research Transition Team.

Upper E Traffic Management↗

EMT Models to Evaluate Traveling Wave-Based Protection in Distribution System

The distribution system is going through significant changes. One of them is the high penetration of inverter-based distributed energy resources in the distribution system. Due to this high penetration, there is a need for a better protection system. Multiple organizations are working on creating novel protection techniques for distribution systems with high penetration of inverter-based DERs. One such innovative method is the use of traveling waves to detect and locate faults. Transmission system protection utilizes this approach, and commercial solutions exist for the transmission system. Using this approach in the distribution system is not straightforward and presents some challenges for implementation. This presentation will discuss the need for using wide-band models to model the traveling wave phenomenon in the distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

User-defined EMT inverter model reference performance, utility-scale [Slides]

This report investigates the response of the inverter under different terminal voltage and operating conditions. The goal is to understand the control objective of the inverter (e.g., injection of reactive current for voltage dips) based on the inverter’s response. No attempt is made to determine the exact control algorithms implemented in the inverter.

14 SOLAR ENERGY↗

A Generic FSC Wind Park EMT Model with IEEE Std 2800-Compliant Fault Ride-Through Capability

The modern power grid is seeing more and more electricity come from renewable sources like wind farms, which use sophisticated power electronics instead of traditional spinning generators. To keep everything running smoothly and meet industry standards such as IEEE 2800, these systems need smart control strategies. In our work, we built a flexible computer model of a full-scale wind farm converter that can handle grid disturbances without shutting down. When a fault or storm hits, the model’s built-in logic automatically adjusts the currents it sends to the grid and protects its internal energy storage, ensuring the wind farm stays connected and doesn’t damage its own equipment. Once the disturbance clears, the model restores normal operation seamlessly, so there’s no long interruption in power delivery. At the same time, it carefully regulates the voltage where the wind farm ties into the larger grid, helping to maintain safe voltage levels across the network. Our simulations show that this control setup not only meets all the requirements of IEEE Standard 2800 but also allows the wind farm to recover quickly and predictably, keeping the lights on no matter what happens on the grid.

17 WIND ENERGY↗