Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRON VOLTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

On-chip integrated laser-driven particle accelerator

Particle accelerators represent an indispensable tool in science and industry. However, the size and cost of conventional radio-frequency accelerators limit the utility and reach of this technology. Dielectric laser accelerators (DLAs) provide a compact and cost-effective solution to this problem by driving accelerator nanostructures with visible or near-infrared pulsed lasers, resulting in a 10 4 reduction of scale. Current implementations of DLAs rely on free-space lasers directly incident on the accelerating structures, limiting the scalability and integrability of this technology. In this article, we present an experimental demonstration of a waveguide-integrated DLA that was designed using a photonic inverse-design approach. By comparing the measured electron energy spectra with particle-tracking simulations, we infer a maximum energy gain of 0.915 kilo–electron volts over 30 micrometers, corresponding to an acceleration gradient of 30.5 mega–electron volts per meter. On-chip acceleration provides the possibility for a completely integrated mega–electron volt-scale DLA.

43 PARTICLE ACCELERATORS↗

Experimental Limit on Optical-Photon Coupling to Light Neutral Scalar Bosons

We report on the first results of a sensitive search for scalar coupling of photons to a light neutral boson in the mass range of approximately 1.0 meV (milli-electron volts) and coupling strength greater than 10{sup -6} GeV{sup -1} using optical photons. This was a photon regeneration experiment using the 'light shining through a wall' technique in which laser light was passed through a strong magnetic field upstream of an optical beam dump; regenerated laser light was then searched for downstream of a second magnetic field region optically shielded from the former. Our results show no evidence for scalar coupling in this region of parameter space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion heating and containment in the NASA Lewis bumpy torus plasma

Experimental observations have been made during steady state operation of a torus experiment at input powers up to 150 kilowatts in deuterium and helium gas. The steady state ion heating method utilizes a modified Penning discharge operated in a bumpy torus confinement geometry. The bumpy torus plasma is acted upon by a combination of strong electric and magnetic fields. In a deuterium plasma, electron temperatures from 14 to 140 electron volts and ion kinetic temperatures from 160 to 1785 electron volts were observed. At least two distinct operating regimes exist, each of which is associated with a characteristic range of background gas pressure and electron temperature. Experimental data show that the average ion residence time in the plasma is virtually independent of magnetic field strength.

Roth, J. R.↗

Ion heating and containment in the NASA Lewis Bumpy Torus plasma

Experimental observations have been made during steady-state operation of the NASA Lewis Bumpy Torus experiment at input powers up to 150 kilowatts in deuterium and helium gas. A steady-state ion heating method utilizes a Modified Penning discharge operated in a bumpy torus confinement geometry. The bumpy torus plasma is acted upon by a combination of strong electric and magnetic fields. In a deuterium plasma, electron temperatures from 14 to 140 electron volts and ion kinetic temperatures from 160 to 1785 electron volts were observed. At least two distinct operating regimes exist, each of which is associated with a characteristic range of background gas pressure and electron temperature. Experimental data show that the average ion residence time (ionization time) in the plasma is virtually independent of the magnetic field strength.

Roth, J. R.↗

Acceleration of auroral electrons in parallel electric fields

Rocket observations of auroral electrons are compared with the predictions of a number of theoretical acceleration mechanisms that involve an electric field parallel to the earth's magnetic field. The theoretical models are discussed in terms of required plasma sources, the location of the acceleration region, and properties of necessary wave-particle scattering mechanisms. We have been unable to find any steady state scatter-free electric field configuration that predicts electron flux distributions in agreement with the observations. The addition of a fluctuating electric field or wave-particle scattering several thousand kilometers above the rocket can modify the theoretical flux distributions so that they agree with measurements. The presence of very narrow energy peaks in the flux contours implies a characteristic temperature of several tens of electron volts or less for the source of field-aligned auroral electrons and a temperature of several hundred electron volts or less for the relatively isotropic 'monoenergetic' auroral electrons. The temperature of the field-aligned electrons is more representative of the magnetosheath or possibly the ionosphere as a source region than of the plasma sheet.

Kaufmann, R. L.↗

An Overview on the role of nuclear data: analysis and evaluation - invited Eugene P. Wigner Reactor Physicist Award Winner

The design and calculation of a nuclear system requires the generation of cross-section libraries in the multi-group or continuous-energy form that is suitable for use in reactor physics computer codes. These working libraries are derived from general purpose libraries, named evaluated nuclear data libraries that are constructed based on data evaluations using physical models and theories. Presently, the most common used evaluated nuclear data libraries are the ENDF/B, JEFF, JENDL, CENDL, and BROND. These general purpose nuclear data libraries are the backbone of any design involving neutron-target interactions. The data for neutron interaction in these libraries spans from fractions of electron-volts (eV), that is 10-5 eV, up to millions of electron-volts (MeV), that is 20 MeV or even higher energies. The purpose of this paper is to provide an overview on the approach used to generate nuclear data for practical applications especially in the resonance energy region. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrafast-induced coherent acoustic phonons in the two-dimensional magnet CrSBr

Magnetism in two-dimensional (2D) van der Waals (vdW) crystals offers promising new directions for low-dimensional physics and devices. In this work, mega-electron volt (MeV) ultrafast electron diffraction was employed to investigate the ultrafast atomic dynamics of a novel, 2D vdW magnetic single-crystal CrSBr. Femtosecond (fs) optical pump pulses excited non-equilibrium atomic displacements shown to be coherent acoustic phonons (CAPs). Phonon frequencies were extracted by analyzing oscillations of different Bragg peak (BP) intensities and were determined to be GHz acoustic disturbances that propagated as strain waves. Phonon modes exhibit anisotropy with respect to the a and b crystal axes. Subharmonic phonon frequencies were also observed, and this provided a signature of nonlinear oscillatory coupling between the laser-induced pumping phonon frequency and secondary phonon frequencies. Thus, CrSBr was found to serve as a nonlinear phononic frequency converter. The ultrafast time dependence of the Bragg intensity was simulated by incorporating an oscillating deviation parameter ansatz into expressions for the dynamical scattering intensity yielded excellent modeling of the ultrafast structural dynamics of the photo-excited 2D crystal. Our work provides a foundation for exploring how fs light pulses can influence phonon dynamics in materials with strong spin-lattice coupling. These results suggest that CAPs can match the magnon frequencies and show the promise of CrSBr for use in optical-to-microwave transducers and phononic devices.

43 PARTICLE ACCELERATORS↗

Quantitative Modeling of High-Energy Electron Scattering in Thick Samples Using Monte Carlo Techniques

Cryo-electron microscopy (cryo-EM) is a powerful tool for imaging biological samples but is typically limited by sample thickness, which is restricted to a few hundred nanometers depending on the electron energy. However, there is a growing need for imaging techniques capable of studying biological samples up to 10 µm in thickness while maintaining nanoscale resolution. This need motivates the use of mega-electron-volt scanning transmission electron microscopy (MeV-STEM), which leverages the high penetration power of MeV electrons to generate high-resolution images of thicker samples. In this study, we employ Monte Carlo simulations to model electron–sample interactions and explore the signal decay of imaging electrons through thick specimens. By incorporating material properties, interaction cross-sections for energy loss, and experimental parameters, we investigate the relationship between the incident and transmitted beam intensities. Key factors such as detector collection angle, convergence semi-angle, and the material properties of samples were analyzed. Our results demonstrate that the relationship between incident and transmitted beam intensities follows the Beer–Lambert law over thicknesses ranging from a few microns to several tens of microns, depending on material composition, electron energy, and collection angles. The linear depth of silicon dioxide reaches 3.9 µm at 3 MeV, about 6 times higher than that at 300 keV. Meanwhile, the linear depth of amorphous ice reaches 17.9 µm at 3 MeV, approximately 11.5 times higher than that at 300 keV. These findings are crucial for advancing the study of thick biological and semiconductor samples using MeV-STEM.

36 MATERIALS SCIENCE↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Accelerating Into the Future: From 0 to GeV in a Few Centimeters (LBNL Summer Lecture Series)

Summer Lecture Series 2008: By exciting electric fields in plasma-based waveguides, lasers accelerate electrons in a fraction of the distance conventional accelerators require. The Accelerator and Fusion Research Division's LOASIS program, headed by Wim Leemans, has used 40-trillion-watt laser pulses to deliver billion-electron-volt (1 GeV) electron beams within centimeters. Leemans looks ahead to BELLA, 10-GeV accelerating modules that could power a future linear collider.

43 PARTICLE ACCELERATORS↗

Accelerating Into the Future: From 0 to GeV in a Few Centimeters (LBNL Summer Lecture Series)

July 8, 2008 Berkeley Lab lecture: By exciting electric fields in plasma-based waveguides, lasers accelerate electrons in a fraction of the distance conventional accelerators require. The Accelerator and Fusion Research Division's LOASIS program, headed by Wim Leemans, has used 40-trillion-watt laser pulses to deliver billion-electron-volt (1 GeV) electron beams within centimeters. Leemans looks ahead to BELLA, 10-GeV accelerating modules that could power a future linear collider.

43 PARTICLE ACCELERATORS↗

An active-optic x-ray fluorescence analyzer with high energy resolution, large solid angle coverage, and a large tuning range

A crystal-optic x-ray fluorescence energy analyzer has been designed and tested, which combines the features of electron-volt energy resolution, large solid angle coverage, and tunability over several kilo-electron-volts. The design is based upon the principle of active optics, with ten actuators available to optimally adjust the shape of a silicon crystal used in the Bragg geometry. In most applications the shape is that of a logarithmic spiral for high energy resolution with a spatially nonresolving detector, but a wide range of other shapes is also possible for applications such as imaging or single-shot spectroscopy in a spectral range of the operator's choosing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Auroral electrons of energy less than 1 keV observed at rocket altitudes.

Measurements of electrons of energy less than 1 keV in the auroral precipitation with detectors aboard three rocket flights are discussed. Detectors simultaneously measured the flux of electrons moving up and down the magnetic field lines. Electrons of energy less than a few hundred electron volts show directional intensities ranging from isotropic over the upper hemisphere, to field aligned into the atmosphere, to a net streaming out of the atmosphere. Cases of reflection coefficients greater than 1 for the few hundred electron volts and lower-energy electrons occur when measurements were made north of auroral forms. These electrons might represent the high-energy tail of the return Birkeland currents. The origin of the low-energy electrons is itself in question.

Arnoldy, R. L.↗

Dose- and Ion-Dependent Effects in the Oxidative Stress Response to Space-Like Radiation Exposure in the Skeletal System

Exposure to space radiation may pose a risk to skeletal health during subsequent aging. Irradiation acutely stimulates bone remodeling in mice, although the long-term influence of space radiation on bone-forming potential (osteoblastogenesis) and possible adaptive mechanisms are not well understood. We hypothesized exposure to ionizing radiation impairs osteoblastogenesis in an ion-type specific manner, with low doses capable of modulating expression of redox-related genes. 16-week old, male, C57BL6/J mice were exposed to low linear-energy-transfer (LET) protons (150 mega electron volts per nucleon) or high-LET (sup 56) Fe ions (600 mega electron volts per nucleon) using either low (5 or 10 centigrays) or high (50 or 200 centigrays) doses at NASAs Space Radiation Lab at Brookhaven National Lab (NSRL/BNL). Tissues were harvested 5 weeks or 1 year after irradiation and bones were analyzed by microcomputed tomography for cancellous microarchitecture and cortical geometry. Marrow-derived, adherent cells were grown under osteoblastogenic culture conditions. Cell lysates were analyzed for select groups by RT-PCR (Reverse Transcription-Polymerase Chain Reaction) during the proliferative phase or the mineralizing phase, and differentiation was analyzed by imaging mineralized nodules (percentage surface area). Representative genes were selected for expression analyses, including cell proliferation (PCNA, Cdk2, p21, p53), differentiation (Runx2, Alpl, Bglap), oxidative metabolism (Catalase, GPX, MnSOD, CuZnSOD, iNos, Foxo1), DNA-damage repair (Gadd45), or apoptosis (Caspase 3). As expected, a high dose (200 centigrays), but not low doses, of either (sup 56) Fe or protons caused a loss of cancellous bone volume per total volume. Marrow cells produced mineralized nodules ex vivo regardless of radiation type or dose; (sup 56) Fe (200 centigrays) inhibited median nodule area by more than 90 percent at 5 weeks and 1 year post-irradiation, compared to controls. At 5 weeks post exposure, irradiation with protons or (sup 56) Fe caused few changes in gene expression levels during osteoblastogenesis, although a high dose of (sup 56) Fe (200 centigrays) increased levels of Catalase and Gadd45. In addition, supplementing cell culture media with SOD protected marrow-derived osteoprogenitors from the damaging effects of exposure to low-LET ((sup 137) Cs gamma) if irradiated in vitro, but had limited protective effects on high-LET (sup 56) Fe-exposed cells. In sum, exposure of mice to either protons or (sup 56) Fe at a relatively high dose (200 cGy) caused persistent bone loss, whereas only high-LET (sup 56) Fe increased expression of redox-related genes and inhibited osteoblastogenesis, albeit to a limited extent. We conclude that high-LET irradiation impaired osteoblastogenesis and regulated steady-state gene expression of select redox-related genes during osteoblastogenesis, which may contribute to persistent bone loss.

ionizing radiation↗

EMIC Wave-Driven Bounce Resonance Scattering of Energetic Electrons in the Inner Magnetosphere

While electromagnetic ion cyclotron (EMIC) waves have been long studied as a scattering mechanism for ultrarelativistic (megaelectron volt) electrons via cyclotron‐resonant interactions, these waves are also of the right frequency to resonate with the bounce motion of lower‐energy (approximately tens to hundreds of kiloelectron volts) electrons. Here we investigate the effectiveness of this bounce resonance interaction to better determine the effects of EMIC waves on subrelativistic electron populations in Earth's inner magnetosphere. Using wave and plasma parameters directly measured by the Van Allen Probes, we estimate bounce resonance diffusion coefficients for four different events, illustrative of wave and plasma parameters to be encountered in the inner magnetosphere. The range of electron energies and pitch angles affected is examined to better assess the realistic effects of EMIC‐driven bounce resonance on energetic electron populations based on actual, locally observed event‐based parameters. Significant local diffusion coefficients (~ > 10(exp −6) s(exp −1)) for 50‐ to 100‐keV electrons are achieved for both H+ band wave events as well as He+ band, with diffusion coefficients peaking for near‐90° pitch angles but remaining elevated for intermediate ones as well. Diffusion coefficients for higher‐energy 200‐keV electrons are typically multiple orders of magnitude lower (ranging from 10(exp −11) to 10(exp −6) s(exp −1)) and often peak at lower pitch angles (~20–30°). These results suggest that both H+ and He+ band EMIC waves can play a role in shaping lower‐energy electron dynamics via bounce‐resonant interactions, in addition to their role in relativistic electron loss via cyclotron resonance.

Blum, L. W.↗

An Empirical Model of Radiation Belt Electron Pitch Angle Distributions Based On Van Allen Probes Measurements

Based on over 4 years of Van Allen Probes measurements, an empirical model of radiation belt electron equatorial pitch angle distribution (PAD) is constructed here. The model, developed by fitting electron PADs with Legendre polynomials, provides the statistical PADs as a function of L-shell (L = 1–6), magnetic local time, electron energy (~30 keV to 5.2 MeV), and geomagnetic activity (represented by the Dst index) and is also the first empirical PAD model in the inner belt and slot region. For megaelectron volt electrons, model results show more significant day-night PAD asymmetry of electrons with higher energies and during disturbed times, which is caused by geomagnetic field configuration and flux radial gradient changes. Steeper PADs with higher fluxes around 90° pitch angle and lower fluxes at lower pitch angles for higher-energy electrons and during active times are also present, which could be due to electromagnetic ion cyclotron wave scattering. For hundreds of kiloelectron volt electrons, cap PADs are generally present in the slot region during quiet times and their energy-dependent features are consistent with hiss wave scattering, while during active times, cap PADs are less significant especially at outer part of slot region, which could be due to the complex energizing and transport processes. Finally, the 90°-minimum PADs are persistently present in the inner belt and appear in the slot region during active times, and minima at 90° pitch angle are more significant for electrons with higher energies, which could be a critical evidence in identifying the underlying physical processes responsible for the formation of 90°-minimum PADs.

79 ASTRONOMY AND ASTROPHYSICS↗

An Empirical Model of Radiation Belt Electron Pitch Angle Distributions Based On Van Allen Probes Measurements

Based on over 4 years of Van Allen Probes measurements, an empirical model of radiation belt electron equatorial pitch angle distribution (PAD) is constructed. The model, developed by fitting electron PADs with Legendre polynomials, provides the statistical PADs as a function of L-shell (L = 1-6), magnetic local time, electron energy (~30 keV to 5.2 MeV), and geomagnetic activity (represented by the Dst index) and is also the first empirical PAD model in the inner belt and slot region. For megaelectron volt electrons, model results show more significant day-night PAD asymmetry of electrons with higher energies and during disturbed times, which is caused by geomagnetic field configuration and flux radial gradient changes. Steeper PADs with higher fluxes around 90° pitch angle and lower fluxes at lower pitch angles for higher energy electrons and during active times are also present, which could be due to electromagnetic ion cyclotron wave scattering. For hundreds of kiloelectron volt electrons, cap PADs are generally present in the slot region during quiet times and their energy-dependent features are consistent with hiss wave scattering, while during active times, cap PADs are less significant especially at outer part of slot region, which could be due to the complex energizing and transport processes. The 90°-minimum PADs are persistently present in the inner belt and appear in the slot region during active times, and minima at 90° pitch angle are more significant for electrons with higher energies, which could be a critical evidence in identifying the underlying physical processes responsible for the formation of 90°-minimum PADs.

Zhao, H.↗