Thermionic Sources for Electron Cooling at IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project in the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling 2.5 MeV protons. One source will be used to compensate for emittance growth due to Intra Beam Scattering in experiments with weak space-charge, while the other source will be used to research the interplay between electron cooling and intense space charge. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources.

43 PARTICLE ACCELERATORS↗

Thermionic Sources for Electron Cooling at IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project in the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling 2.5 MeV protons. One source will be used to compensate for emittance growth due to Intra Beam Scattering in experiments with weak space-charge, while the other source will be used to research the interplay between electron cooling and intense space charge. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources.

43 PARTICLE ACCELERATORS↗

Wall heating by subcritical energetic electrons generated by the runaway electron avalanche source *

Abstract Subcritical energetic electrons (SEEs) produced by the runaway electron (RE) avalanche source at energies below the runaway threshold are found to be the primary contributor to surface heating of plasma-facing components (PFCs) during final loss events. This finding is supported by theoretical analysis, computational modeling with the Kinetic Orbit Runaway electrons Code (KORC), and qualitative agreement with DIII-D experimental observations. The avalanche source generates significantly more secondary electrons below the runaway threshold, which thermalize rapidly when well-confined. However, during a final loss event, the RE beam impacts the first wall, and SEEs are deconfined before they can thermalize. Additionally, because the energy deposition length decreases faster than energy, the deposited energy density, and thus the maximum PFC surface temperature change, is larger for SEEs than REs. KORC simulations employ an analytic first wall to model particle deconfinement onto a non-axisymmetric wall composed of individual tiles. PFC surface heating is calculated using a 1D model extended to include an energy-dependent deposition length scale. Simulations of DIII-D qualitatively agree with infrared (IR) imaging only when SEEs from the avalanche source are included. These results demonstrate that SEEs are the dominant contributor to PFC surface heating and indicate that the avalanche source plays a critical role in the PFC damage caused during final loss events. The prominence of SEEs also has important implications for interpreting IR imaging, one of the primary diagnostics for RE-wall interaction diagnosis, despite REs dominating the energy and current density. This result improves predictions of wall damage due to post-disruption REs to estimate material lifetime and design RE mitigation systems for ITER and future reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photoemission characterization of N-polar III-nitride photocathodes as candidate bright electron beam sources for accelerator applications

We report on the growth and characterization of a new class of photocathode structures for use as electron sources to produce high brightness electron beams for accelerator applications. The sources are realized using III-nitride materials and are designed to leverage the strong polarization field, which is characteristic of this class of materials when grown in their wurtzite crystal structure, to produce a negative electron affinity condition without the use of Cs, possibly allowing these materials to be operated in radio frequency guns. A Quantum Efficiency (QE) of about 1×10−3 and an emitted electrons’ Mean Transverse Energy (MTE) of about 100 meV are measured at a wavelength of 265 nm. In a vacuum level of 3×10−10 Torr, the QE does not decrease after more than 24 h of continuous operation. The lowest MTE of about 50 meV is measured at 300 nm along with a QE of 1.5×10−5. Surface characterizations reveal a possible contribution to the MTE from surface morphology, calling for more detailed studies.

Cultrera, L. (ORCID:0000000235606059)↗

Demonstration of closed shell breeding of cesium ions with an electron beam ion source

An electron beam ion source serves as a charge breeder for the Californium Rare Isotope Breeder Upgrade (CARIBU) at the Argonne Tandem Linac Accelerator System (ATLAS). The source accepts radioactive beams of 1+ or 2+ ions and raises their charge state for post-acceleration by ATLAS. The efficiency of this process impacts the length of each experiment and, hence, the type and number of experiments that can be run in each program cycle. Recent efforts to improve the charge breeding efficiency for the 80 < A < 160 species typical of CARIBU have focused on utilizing the closed shell breeding technique. Here, with this technique, the electron beam energy is manipulated to take advantage of the large gap in ionization energies at shell closures and selectively populate a single charge state. Charge breeding studies with stable cesium ions have demonstrated an absolute efficiency of 72% for Cs 27+ and a total efficiency of 93%. The Cs 27+ efficiency result represents a factor of 3 improvement over the previous best charge breeding result of 23% for Cs 27+ .

Vondrasek, R. [Argonne National Laboratory (ANL), ↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prediction and Measurement of X-Ray Spectral and Intensity Distributions from Low Energy Electron Impact Sources

In-vacuum electron beam welding is a technology that NASA considered as a joining technique for manufacture of space structures. The interaction of energetic electrons with metal produces x-rays. The radiation exposure to astronauts performing the in-vacuum electron beam welding must be characterized and minimized to insure safe operating conditions. This investigation characterized the x-ray environment due to operation of an in-vacuum electron beam welding tool. NASA, in a joint venture with the Russian Space Agency, was scheduled to perform a series of welding in space experiments on board the United States Space Shuttle. This series of experiments was named the International Space Welding Experiment (ISWE). The hardware associated with the ISWE was leased to NASA, by the Paton Welding Institute (PWI) in Ukraine, for ground based welding experiments in preparation for flight. Two tests were scheduled, using the ISWE electron beam welding tool, to characterize the radiation exposure to an astronaut during the operation of the ISWE. These radiation exposure tests consisted of Thermoluminescence Dosimeters (TLD's) shielded with material currently used by astronauts during Extra Vehicular Activities (EVA) and exposed to x-ray radiation generated by operation of an in-vacuum electron beam welding tool. This investigation was the first known application of TLD's to measure absorbed dose from x-rays of energy less than 10 KeV. The ISWE hardware was returned to Ukraine before the issue of adequate shielding for the astronauts was verified. Therefore, alternate experimental and analytical methods were developed to measure and predict the x-ray spectral and intensity distribution generated by electron impact with metal. These x-ray spectra were used to calculate the absorbed radiation dose to astronauts. These absorbed dose values were compared to TLD measurements obtained during actual operation of the in-vacuum electron beam welding tool. The calculated absorbed dose values were found to be in good agreement with the TLD values.

Edwards, David L.↗

Arbitrary electron dose waveforms for electron microscopy

A device may include an electron source, a detector, and a deflector. The electron source may be directed toward a sample area. The detector may receive an electron signal or an electron-induced signal. A deflector may be positioned between the electron source and the sample. The deflector may modulate an intensity of the electron source directed to the sample area according to an electron dose waveform having a continuously variable temporal profile.

Bloom, Ruth Shewmon↗

Arbitrary electron dose waveforms for electron microscopy

A device may include an electron source, a detector, and a deflector. The electron source may be directed toward a sample area. The detector may receive an electron signal or an electron-induced signal. A deflector may be positioned between the electron source and the sample. The deflector may modulate an intensity of the electron source directed to the sample area according to an electron dose waveform having a continuously variable temporal profile.

Bloom, Ruth Shewmon↗

Flexible high-voltage supply for experimental electron microscope

Scanning microscope uses a field-emission tip for the electron source, an electron gun that simultaneously accelerates and focuses electrons from the source, and one auxiliary lens to produce a final probe size at the specimen on the order of angstroms.

Chapman, G. L.↗

Carbon Nanotube Patterning on a Metal Substrate

A CNT electron source, a method of manufacturing a CNT electron source, and a solar cell utilizing a CNT patterned sculptured substrate are disclosed. Embodiments utilize a metal substrate which enables CNTs to be grown directly from the substrate. An inhibitor may be applied to the metal substrate to inhibit growth of CNTs from the metal substrate. The inhibitor may be precisely applied to the metal substrate in any pattern, thereby enabling the positioning of the CNT groupings to be more precisely controlled. The surface roughness of the metal substrate may be varied to control the density of the CNTs within each CNT grouping. Further, an absorber layer and an acceptor layer may be applied to the CNT electron source to form a solar cell, where a voltage potential may be generated between the acceptor layer and the metal substrate in response to sunlight exposure.

Nguyen, Cattien V.↗

Higher-Sensitivity Ionization Trace-Species Detector

Electron source and electron optics of reversal electron-attachment detector modified to increase sensitivity. Original version described in "High-Sensitivity Ionization Trace-Species Detector" (NPO-17596). Used to detect molecules of particular chemical species of interest (e.g., narcotics, explosives, or organic wastes) present in air at low concentrations, and known to attach extremely low-energy electrons. Apparatus does this by ionizing molecules from sampled atmosphere, then detecting ions of species of interest. Detector features indirectly heated spherical cathode and redesigned electron optics, together, deliver more electrons at low kinetic energy to reversal plane, R. Greater electron current generates more ions for detection.

Boumsellek, Said↗

Manufacturing Supply Chain Development for Modular Solar-Thermochemical Conversion Platform [Abstract]

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING↗

Optically Stimulated Luminescence Data Storage (Abstract)

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING↗