Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRON MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Graphical template software for accurate micromanipulation in a scanning electron microscope

Micromanipulation techniques in a scanning electron microscope (SEM) have been utilized for assembling micrometer-sized structures. The precision of the assembled microstructures has been limited by the poor accuracy of the SEM image. We have developed a software to assist the operator in the accurate assembly of microstructures in a SEM, in which computer-generated outlines of the target structure [graphical templates (GTs)] are superimposed on the monitor. The displayed GTs are distorted on the basis of the image properties of the SEM evaluated in advance. As a consequence, the operator can construct microstructures with a high precision only by maneuvering the manipulator so that the outline of each object perfectly overlaps the GT without any alteration of the electron optics or circuits for improving the image accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strain mapping at the nanoscale using precession electron diffraction in transmission electron microscope with off axis camera

Precession electron diffraction is an efficient technique to measure strain in nanostructures by precessing the electron beam, while maintaining a few nanometre probe size. Here, we show that an advanced diffraction pattern treatment allows reproducible and precise strain measurements to be obtained using a default 512 × 512 DigiSTAR off-axis camera both in advanced or non-corrected transmission electron microscopes. This treatment consists in both projective geometry correction of diffraction pattern distortions and strain Delaunay triangulation based analysis. Precision in the strain measurement is improved and reached 2.7 × 10{sup −4} with a probe size approaching 4.2 nm in diameter. This method is applied to the study of the strain state in InGaAs quantum-well (QW) devices elaborated on Si substrate. Results show that the GaAs/Si mismatch does not induce in-plane strain fluctuations in the InGaAs QW region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controlling hydrocarbon transport and electron beam induced deposition on single layer graphene: Toward atomic scale synthesis in the scanning transmission electron microscope

Abstract Focused electron beam induced deposition (FEBID) is a direct write technique for depositing materials on a support substrate akin to 3D printing with an electron beam (e‐beam). Opportunities exist for merging this existing technique with aberration‐corrected scanning transmission electron microscopy to achieve molecular‐ or atomic‐level spatial precision. Several demonstrations have been performed using graphene as the support substrate. A common challenge that arises during this process is e‐beam‐induced hydrocarbon deposition, suggesting greater control over the sample environment is needed. Various strategies exist for cleaning graphene in situ. One of the most effective methods is to rapidly heat to high temperatures, for example, 600℃ or higher. While this can produce large areas of what appears to be atomically clean graphene, mobile hydrocarbons can still be present on the surfaces. Here, we show that these hydrocarbons are primarily limited to surface migration and demonstrate an effective method for interrupting the flow using e‐beam deposition to form corralled hydrocarbon regions. This strategy is effective for maintaining atomically clean graphene at high temperatures where hydrocarbon mobility can lead to substantial accumulation of unwanted e‐beam deposition.

36 MATERIALS SCIENCE↗

Monitoring micro-crack healing in an engineered cementitious composite using the environmental scanning electron microscope

Environmental Scanning Electron Microscopy (ESEM) is used to study the origin of micro-crack healing in an Engineered Cementitious Composite (ECC). ESEM images were acquired from ECC specimens cut from pre-cracked, dog-bone samples which then subjected to submerged curing followed by exposure to the natural environment. The mineralogical and chemical compositions of the healing products were determined using the EDX facility in the ESEM. It is shown that the precipitation of calcium carbonate is the main contributor to micro-crack healing at the crack mouth. The healing products initially appeared in an angular rhombohedral morphology which then underwent a discernable transformation in size, shape and surface texture, from relatively flat and smooth to irregular and rough, resembling the texture of the original surface areas surrounding the micro-cracks. It is also shown that exposure to the natural environment, involving intermittent wetting/drying cycles, promotes additional crystal growth, which indicates enhanced self-healing capability in this environment. - Highlights: •ESEM with EDX used to characterize the origin of micro-crack healing in an ECC •Evolution of healing precipitates studied at three specific locations over four weeks •Specimens exposed to laboratory environment, followed by the natural environment •Calcium carbonate is the main contributor to crack healing at the crack mouth. •Outdoor exposure involving intermittent rain promotes additional crystal growth.

36 MATERIALS SCIENCE↗

Sub-Ångstrom electric field measurements on a universal detector in a scanning transmission electron microscope

Scanning transmission electron microscopy (STEM) excels in accessing atomic-scale structure and chemistry. Enhancing our ability to directly image the functionalities of local features in materials has become one of the most important topics in the future development of STEM. Recently, differential phase contrast (DPC) imaging has been utilized to map the internal electric and magnetic fields in materials from nanoscale features such as p–n junctions, skyrmions, and even from individual atoms. Here, we use an ultra-low noise SCMOS detector in as the diffraction plane camera to collect four-dimensional (4D) datasets. The high angular resolution, efficient high-SNR acquisition, and modifiability of the camera allow it to function as a universal detector, where STEM imaging configurations, such as DPC, bright field, annular bright field, and annular dark field can all be reconstructed from a single 4D dataset. By examining a distorted perovskite, DyScO3, which possesses projected lattice spacings as small as 0.83 Å, we demonstrate DPC spatial resolution almost reaching the information limit of a 100 keV electron beam. In addition, the perovskite has ordered O-coordinations with alternating octahedral tilts, which can be quantitatively measured with single degree accuracy by taking advantage of DPC’s sensitivity to light atoms. The results, acquired on a standard Ronchigram camera as opposed to a specialized DPC detector, open up new opportunities to understand and design functional materials and devices that involve lattice and charge coupling at nano- and atomic-scales.

47 OTHER INSTRUMENTATION↗

Single-Digit Nanometer Electron-Beam Lithography with an Aberration-Corrected Scanning Transmission Electron Microscope

Here, we demonstrate extension of electron-beam lithography using conventional resists and pattern transfer processes to single-digit nanometer dimensions by employing an aberration-corrected scanning transmission electron microscope as the exposure tool. Here, we present results of single-digit nanometer patterning of two widely used electron-beam resists: poly (methyl methacrylate) and hydrogen silsesquioxane. The method achieves sub-5 nanometer features in poly (methyl methacrylate) and sub-10 nanometer resolution in hydrogen silsesquioxane. High-fidelity transfer of these patterns into target materials of choice can be performed using metal lift-off, plasma etch, and resist infiltration with organometallics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Unveiling the Mysteries of Mars with a Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM)

Development of a miniaturized scanning electron microscope that will utilize the martian atmosphere to dissipate charge during analysis continues. This instrument is expected to be used on a future rover or lander to answer fundamental Mars science questions. To identify the most important questions, a survey was taken at the 47th Lunar and Planetary Science Conference (LPSC). From the gathered information initial topics were identified for a SEM on the martian surface. These priorities are identified and discussed below. Additionally, a concept of operations is provided with the goal of maximizing the science obtained with the minimum amount of communication with the instrument.

Mars↗

Reducing experimental uncertainty in the calculation of cavity swelling in a transmission electron microscope through crystallographically aided void volume tracking

Accurate measurement of cavity swelling in a transmission electron microscope is essential to define material performance under irradiation, and the conventionally applied spherical assumption for the calculation of cavity volumes in irradiated materials can result in errors ranging between a 25% underestimation and 72% overestimation of volume purely based on the assumption of shape. This assumption is undeniably expedient for calculation but does not sufficiently account for the 3D nature of polyhedral cavities and their shape projection in the transmission electron microscope, and therefore presents too large of an associated uncertainty in swelling determination for faceted cavities. This uncertainty has been defined for many common cavity shapes in FCC and BCC crystal systems, and has been tabulated across the cubic fundamental region. A revised methodology for crystallographically aided void volume tracking, or CAVV-T, is presented and demonstrated on a specimen of neutron irradiated Ni. In-depth discussion on the application of this technique is provided along with resources to allow for conversion between the spherical assumption and this revised method. This work seeks to increase experimental confidence in the characterization and quantification of critical aspects of irradiation damage in materials by applying a crystallographically-resolved approach for cavity swelling calculation.

Haag IV, James V. [Pacific Northwest National Labo↗

Fabrication of large area plasmonic nanoparticle grating structure on silver halide based transmission electron microscope film and its application as a surface enhanced Raman spectroscopy substrate

The plasmonic responses of silver nanoparticle grating structures of different periods made on silver halide based electron microscope film are investigated. Raster scan of the conventional scanning electron microscope (SEM) is used to carry out electron beam lithography for fabricating the plasmonic nanoparticle grating (PNG) structures. Morphological characterization of the PNG structures, carried out by the SEM and the atomic force microscope, indicates that the depth of the groove decreases with a decrease in the grating period. Elemental characterization performed by the energy dispersive spectroscopy and the x-ray diffraction shows the presence of nanoparticles of silver in the PNG grating. The optical characterization of the gratings shows that the localized surface plasmon resonance peak shifts from 366 to 378 nm and broadens with a decrease in grating period from 10 to 2.5 μm. The surface enhanced Raman spectroscopy of the Rhodamine-6G dye coated PNG structure shows the maximum enhancement by two orders of magnitude in comparison to the randomly distributed silver nanoparticles having similar size and shape as the PNG structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffusion length measurements using the scanning electron microscope

A measurement technique employing the scanning electron microscope is described in which values of the true bulk diffusion length are obtained. It is shown that surface recombination effects can be eliminated through the application of highly doped surface field layers. The influence of high injection level effects and low-high junction current generation on the resulting measurement was investigated. Close agreement is found between the diffusion lengths measured by this method and those obtained using a penetrating radiation technique.

Weizer, V. G.↗

Gas delivery system for environmental transmission electron microscope

A portable, compact gas delivery system can support an environmental transmission electron microscope. Environment transmission electron microscopy provides researchers a unique capability of assessing a material's surface conditions at atomic resolution in a variety of reactive and oxidizing environments. The ability to precisely control the analysis chamber's environmental conditions over time is key to the success of a typical surface analysis. The gas delivery system provides the correct balance or pressure delivery precision, contamination control, and gas isolation.

Nogan, John Joseph↗

Note: Direct measurement of the point-to-point resolution for microns-thick specimens in the ultrahigh-voltage electron microscope

We report on a direct measurement method and results of the point-to-point resolution for microns-thick amorphous specimens in the ultrahigh-voltage electron microscope (ultra-HVEM). We first obtain the ultra-HVEM images of nanometer gold particles with different sizes on the top surfaces of the thick epoxy-resin specimens. Based on the Rayleigh criterion, the point-to-point resolution is then determined as the minimum distance between centers of two resolvable tangent gold particles. Some values of resolution are accordingly acquired for the specimens with different thicknesses at the accelerating voltage of 2 MV, for example, 18.5 nm and 28.4 nm for the 5 {mu}m and 8 {mu}m thick epoxy-resin specimens, respectively. The presented method and results provide a reliable and useful approach to quantifying and comparing the achievable spatial resolution for the thick specimens imaged in the mode of transmission electron including the scanning transmission electron microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunable electron beam pulser for picoseconds stroboscopic microscopy in transmission electron microscopes

For two decades, time-resolved transmission electron microscopes (TEM) have relied on pulsed-laser photoemission to generate electron bunches to explore sub-microsecond to sub-picosecond dynamics. Despite the vast successes of photoemission time-resolved TEMs, laser-based systems are inherently complex, thus tend not to be turn-key. In this paper, we report on the successful retrofit of a commercial 200 keV TEM, without an external laser, capable of producing continuously tunable pulsed electron beams with repetition rates from 0.1 GHz up to 12 GHz and a tunable bunch length from tens of nanoseconds down to 10 ps. This innovation enables temporal access into previously inaccessible regimes: i.e., high repetition rate stroboscopic experiments. Combination of a pair of RF-driven traveling wave stripline elements, quadrupole magnets, and a variable beam aperture enables operation of the instrument in (1) continuous waveform (CW) mode as though the instrument was never modified (i.e. convention TEM operation mode, where the electrons from the emission cathode randomly arrive at the sample without resolvable time information), (2) stroboscopic (pump-probe) mode, and (3) pulsed beam mode for dose rate sensitive materials. In order to analyze the effect of a pulsed beam on image quality, we examined Au nanoparticles using bright field, high-resolution TEM imaging and selected area diffraction in both continuous and pulsed-beam mode. Furthermore, in comparison of conventional TEMs, the add-on beam pulser enables the observation of ultrafast dynamic behavior in materials that are reversible under synchronized excitation.

36 MATERIALS SCIENCE↗

A Closed-Loop Proportional-Integral (PI) Control Software for Fully Mechanically Controlled Automated Electron Microscopic Tomography

A closed-loop proportional-integral (PI) control software is provided for fully mechanically controlled automated electron microscopic tomography. The software is developed based on Gatan DigitalMicrograph, and is compatible with Zeiss LIBRA 120 transmission electron microscope. However, it can be expanded to other TEM instrument with modification. The software consists of a graphical user interface, a digital PI controller, an image analyzing unit, and other drive units (i.e.: image acquire unit and goniometer drive unit). During a tomography data collection process, the image analyzing unit analyzes both the accumulated shift and defocus value of the latest acquired image, and provides the results to the digital PI controller. The digital PI control compares the results with the preset values and determines the optimum adjustments of the goniometer. The goniometer drive unit adjusts the spatial position of the specimen according to the instructions given by the digital PI controller for the next tilt angle and image acquisition. The goniometer drive unit achieves high precision positioning by using a backlash elimination method. The major benefits of the software are: 1) the goniometer drive unit keeps pre-aligned/optimized beam conditions unchanged and achieves position tracking solely through mechanical control; 2) the image analyzing unit relies on only historical data and therefore does not require additional images/exposures; 3) the PI controller enables the system to dynamically track the imaging target with extremely low system error.

Ren, Gang↗

Development of a miniature scanning electron microscope for in-flight analysis of comet dust

A description is presented of an instrument which was developed with the original goal of being flown on the International Comet Mission, scheduled for a 1985 launch. The Scanning Electron Microscope and Particle Analyzer (SEMPA) electron miniprobe is a miniaturized electrostatically focused electron microscope and energy dispersive X-ray analyzer for in-flight analysis of comet dust particles. It was designed to be flown on board a comet rendezvous spacecraft. Other potential applications are related to asteroid rendezvous and planetary lander missions. According to the development objectives, SEMPA miniprobe is to have the capability for imaging and elemental analysis of particles in the size range of 0.25 microns and larger.

Conley, J. M.↗

Electron Microscopic Examination of an Irradiated TRISO Coated Particle of AGR-2 Experiment: AGR2-222-RS019

The transmission electron microscopic (TEM) examination of an irradiated tristructural isotropic (TRISO) coated particle from advanced gas reactor (AGR) 2 fuel Compact 2-2-2 is presented in this report. Compact 2-2-2 refers to the compact in Capsule 2 at Level 2 of Stack 2. The examination on AGR2 222 RS019 is focused on the interface between the silicon carbide (SiC) to inner pyrolytic carbon (IPyC) layer, central part of SiC, and the interface between SiC and outer pyrolytic carbon layer. The SiC grain boundary distribution and associated fission product precipitates were characterized by scanning transmission electron microscopy (STEM) energy dispersive spectroscopy (EDS), and precession electron diffraction (PED) in the transmission electron microscope. Two separate locations on SiC layer were selected for on the basis of the intact of the buffer layer in the irradiated TRISO particle. The key observation in this particle is that the compositional nature of grain boundary precipitates is more complex near IPyC/SiC layer where Pd, Pd-Ag, Pd-U containing precipitates can be observed. However, the compositions of precipitate towards outer most region of SiC mainly contain Pd. Ag has been observed in the IPyC/SiC layer in one of the two locations. Comparison of the results to previously irradiated and analyzed, Variant 3, safety tested AGR-1 TRISO particles (AGR1-433-001 and AGR1 222-RS004) showed the grain boundary distributions have some noticeable differences. The differences in coincident site lattice grain boundary and misorientation angles are possibly inherent to the fabrication process. Neutron irradiation induced void distribution has been found to be nonuniform. A high concentration of smaller voids is found at stacking faults compared to those in the SiC matrix. Larger void sizes are observed in the SiC location that is near to the broken buffer layer. This void size variation with integrity of buffer layer can potentially affect the fission product retention. However, the average void size continuously decreases along the radius of SiC in both locations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion and electron beam nanofabrication of the which-way double-slit experiment in a transmission electron microscope

We have realized a which-way experiment closely resembling the original Feynman's proposal exploiting focused ion beam milling to prepare two nanoslits and electron beam induced deposition to grow, selectively over one of them, electron transparent layers of low atomic number amorphous material to realize a which-way detector for high energy electrons. By carrying out the experiment in an electron microscope equipped with an energy filter, we show that the inelastic scattering of electron transmitted through amorphous layers of different thicknesses provides the control of the dissipative interaction process responsible for the localization phenomena which cancels out the interference effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗