Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurement of the environmental broadband electromagnetic waves in a mid-size European city

In this paper, the level of exposure to broadband radiofrequency electromagnetic field in a mid-size European city was evaluated in accordance with the International Commission on Non-ionizing Radiation Protection guidelines from 1998. With the aim to analyse all the potential electromagnetic waves present in the city up to 18 GHz, a total of 271 locations distributed along Terrassa (Spain) have been measured. To show the results in an easy-to-interpret way by the citizen, the results have been represented in a set of raster maps. The measurement results obtained showed that the electromagnetic wave measured in all broadband frequency range along the city is much lower than the safety level according to the international regulations for both public and occupational sectors.

54 ENVIRONMENTAL SCIENCES↗

Measurement of the Neutron Electromagnetic Form Factor Ratio at High Momentum Transfer

The inner structure of the nucleon (proton and neutron) remains a topic of great interest in nuclear and particle physics, after many decades of study. For example, understanding the quark-gluon dynamics inside the nucleon would shed light on how 99% of the nucleon mass is created. The neutron electromagnetic form factors, Gn E and Gn M , give important insights into the neutron structure. The Super BigBite Spectrometer (SBS) program at Jefferson Lab (JLab) seeks to extend the form factor measurements for both the proton and the neutron. The neutron electric form actor, Gn E , has been historically difficult to measure due to the short lifetime of the free neutron and the small value of Gn E . The GEn-II experiment is part of the SBS program and seeks to measure Gn E , significantly increasing the high momentum transfer coverage. A newly designed polarized 3He target increased the figure of merit by three times compared to previous measurements. The analysis of this data is especially challenging due to the unprecedented high-rate environment caused by the open nature of the spectrometer with a direct line of sight to the target. This required developing new Gas Electron Multiplier (GEM) particle trackers which can cover large areas demanded by this setup and handle particle rates up to 500 kHz/cm2. Rates this high over a large area is unprecedented in particle tracking systems and came with a number of challenges. Data taken in the SBS program was critical to understanding hardware and software solutions that improved the track reconstruction efficiency to be >97% with a position resolution of 70 ?m. In previous experiments the proton electromagnetic form factors, Gp E and Gp M were measured up to Q2 = 8.5 GeV2 and Q2 = 30 GeV2, respectively, while Gn E has only been measured up to Q2 = 3.4 GeV2. The GEn-II experiment has measured the neutron form factor ratio, Gn E/Gn M, at Q2 values of 2.90, 6.50, and 9.47 GeV2 by scattering a polarized electron beam with a polarized 3He target, used here as an effective polarized neutron target, and measuring the double spin asymmetry of the cross section. Previous Gn E measurements do not extend above Q2 = 3.4 GeV2, and therefore this analysis has extended the world data by almost three times. The background correction is especially difficult at the higher Q2 settings leading to large systematic errors. As very exploratory results from this early analysis of the data, we find for Q2 = 2.90 GeV2, Gn E = 0.0157 ±stat 0.0016 ±sys 0.0011, for Q2 = 6.50 GeV2, Gn E = 0.0067 ±stat 0.0019 ±sys 0.0005, and for Q2 = 9.46 GeV2, Gn E = 0.0046 ±stat 0.0023 ±sys 0.0005. These results are compared to predictions from the Dyson-Schwinger Equations (DSE) model and a Relativistic Constituent Quark Model (RCQM).

Jeffas, Sean↗

Recoil Polarization Measurements of the Proton Electromagnetic Form Factor Ratio to High Momentum Transfer

The electromagnetic form factors of the nucleon characterize the effect of its internal structure on its response to an electromagnetic probe as studied in elastic electronnucleon scattering. These form factors are functions of the squared four-momentum transfer Q 2 between the electron and the proton. The two main classes of observables of this reaction are the scattering cross section and polarization asymmetries, both of which are sensitive to the form factors in different ways. When considering large f momentum transfers, double-polarization observables offer superior sensitivity to the electric form factor. This thesis reports the results of a new measurement of the ratio of the electric and magnetic form factors of the proton at high momentum transfer using the recoil polarization technique. A polarized electron beam was scattered from a liquid hydrogen target, transferring polarization to the recoiling protons. These protons were detected in a magnetic spectrometer which was used to reconstruct their kinematics, including their scattering angles and momenta, and the position of the interaction vertex. A proton polarimeter measured the polarization of the recoiling protons by measuring the azimuthal asymmetry in the angular distribution of protons scattered in CH 2 analyzers. The scattered electron was detected in a large acceptance electromagnetic calorimeter in order to suppress inelastic backgrounds. The measured ratio of the transverse and longitudinal polarization components of the scattered proton is directly proportional to the ratio of form factors G p E =G p M . The measurements reported in this thesis took place at Q 2 =5.2, 6.7, and 8.5 GeV 2 , and represent the most accurate measurements of G p E in this Q 2 region to date.

08 HYDROGEN↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Neutron Electromagnetic Form Factors at High Momentum Transfer Using a Polarized 3He Target at Jefferson Lab

Ever since the composite structure of nucleons was uncovered, many experiments have been commissioned with the purpose of extracting parameters that shape our understanding of this structure. Form factors are powerful tools that rest at the forefront of the nucleon structure study. In the non-relativistic limit, they describe the magnetic and charge distributions inside the nucleon. The GEn-II experiment, which ran in Hall A of Jefferson Lab as a part of the SuperBigbite Spectrometer (SBS) program, aimed to extract the ratio of the neutron’s electric to magnetic Sachs form factors (GnE/GnM. This was accomplished using the double polarization technique: scattering polarized electrons with initial energies up to 8.45 GeV off high-density polarized 3He targets. The experiment was a coincidence measurement, with the scattered electrons detected in the BigBite Spectrometer and the recoil nucleons in a hadron calorimeter, a part of the SuperBigbite Spectrometer. The convection-style target cells used in this experiment have a 60cm long target chamber, an increase from the 40 cm cell used in the most recent polarized 3He target experiment. In addition, the cells were optically pumped from two sides of the pumping chamber. These improvements in design and functionality introduced world-record-breaking luminosity. This thesis presents preliminary results of the GEn-II experiment for the following 4-momentum transfer (Q2) values: 2.93, 6.76, and 9.78 GeV2, in addition to target performance and preliminary polarimetry results.

Presley, Hunter [Univ. of Virginia, Charlottesvill↗

Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Physics opportunities with meson beams

Over the past two decades, meson photo- and electro-production data of unprecedented quality and quantity have been measured at electromagnetic facilities worldwide. By contrast, the meson-beam data for the same hadronic final states are mostly outdated and largely of poor quality, or even nonexistent, and thus provide inadequate input to help interpret, analyze, and exploit the full potential of the new electromagnetic data. To reap the full benefit of the high-precision electromagnetic data, new high-statistics data from measurements with meson beams, with good angle and energy coverage for a wide range of reactions, are critically needed to advance our knowledge in baryon and meson spectroscopy and other related areas of hadron physics. To address this situation, a state of-the-art meson-beam facility needs to be constructed. Furthermore, the present paper summarizes unresolved issues in hadron physics and outlines the vast opportunities and advances that only become possible with such a facility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction and Measurement of $\mathcal{O}$(100) MeV Energy Electromagnetic Activity from $\pi^0 \rightarrow \gamma\gamma$ Decays in the MicroBooNE LArTPC

We present results on the reconstruction of electromagnetic (EM) activity from photons produced in charged current νμ interactions with final state π0s. We employ a fully-automated reconstruction chain capable of identifying EM showers of &calO;(100) MeV energy, relying on a combination of traditional reconstruction techniques together with novel machine-learning approaches. These studies demonstrate good energy resolution, and good agreement between data and simulation, relying on the reconstructed invariant π0 mass and other photon distributions for validation. The reconstruction techniques developed are applied to a selection of νμ + Ar → μ + π0 + X candidate events to demonstrate the potential for calorimetric separation of photons from electrons and reconstruction of π0 kinematics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ternary systems based on PVDF, BaTiO{sub 3} and MWCNTs: Fabrication, characterization, electromagnetic simulation

In this work, ternary bulk systems based on polyvinylidene fluoride (PVDF), synthesised barium titanate (BaTiO{sub 3}, BT) nanopowder and multi walled carbon nanotubes (MWCNTs) were fabricated by film stacking technique, starting from solvent cast films. The main purpose was to investigate the influence of BT and MWCNTs addition to the polymeric matrix on its microstructural and dielectrical properties. In order to achieve it, different BT concentrations, ranging between the 60 and 75 %wt, were tested, whereas a MWCNTs content of 2 %wt was maintained constant. The morphology was studied by observation at scanning electron microscopy (SEM), the microstructure and crystalline phases investigated by X-Ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy, and the electromagnetic properties measured in the microwave region (8-12 GHz). The electromagnetic response of the investigated bulk systems was also simulated as function of the sample thickness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Feasibility studies of time-like proton electromagnetic form factors at $\overline{\rm P}$ANDA at FAIR

Simulation results for future measurements of electromagnetic proton form factors at $\overline{\rm P}$ANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the proton form factors can be determined is estimated. The signal channel p¯p → e + e – is studied on the basis of two different but consistent procedures. The suppression of the main background channel, i.e. p¯p → π + π – , is studied. Furthermore, the background versus signal efficiency, statistical and systematical uncertainties on the extracted proton form factors are evaluated using two different procedures. The results are consistent with those of a previous simulation study using an older, simplified framework. Furthermore, a slightly better precision is achieved in the PandaRoot study in a large range of momentum transfer, assuming the nominal beam conditions and detector performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-frequency signatures of space-leader evolution in negative cloud-to-ground lightning stepped leaders

In this study, we examined 364 space leaders in 18 negative natural cloud-to-ground lightning strokes whose stepped leaders created new channels to ground. All strokes were captured on ultra-high-speed video cameras operating at frame rates ranging from 400k to 783k frames per second. Additionally, broadband electromagnetic field measurements were available for a subset of these strokes. The median space leader inception-to-attachment-point length and retrograde propagation speed towards the pre-existing leader channel (PELC) were 8.2 m and 4.0 x 10 6 m/s, respectively. Space leader lengths were longer and retrograde propagation speeds faster for return strokes with higher peak currents. This is likely due to the relative proximity of space leader inception points to the PELC, which makes the electric field produced by the PELC line charge density one of the primary factors in determining space leader characteristics. Space leader characteristics were weakly related to their inception altitude. We observed bursts of very high frequency (VHF) emissions preceding, by around 0.5 – 1 μs, electric field leader-step pulses; visible-frequency-range luminosity pulses started during the step pulses. The median downward leader propagation speed for all 18 strokes was 4.3 x 10 5 m/s; leader propagation speeds were generally faster for return strokes with higher peak currents. Also, leaders appeared to accelerate (on their way to ground) at altitudes lower than about 200 and 1000 m above ground level for strokes in the 10 – 60 and 84 – 228 kA peak current ranges, respectively.

54 ENVIRONMENTAL SCIENCES↗

EMR Measurements on NDA Equipment

Electromagnetic radiation (EMR) emission strength measurements were performed on a suite of passive non-destructive assay (NDA) radiation detection equipment. Data were collected from 9 kHz up to 6 GHz on each of the assembled systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency Dependence of an Electromagnetic Absorption Coefficient in Magnetic Fluid

The samples of water-based magnetic fluid, which contain Fe{sub 3}O{sub 4}–SiO{sub 2} particles with a spherical shape and sizes less than 100 nm, have been obtained. The method based on using a transmission line has been applied to measure the electromagnetic absorption coefficient in the frequency range from 0.1 to 18.0 GHz using a measuring setup based on horn antennas and the cell based on a coplanar transmission line. It has been found that magnetic fluids can be used to produce electromagnetic shields and electromagnetic wave absorbers as well as means to carry out local hyperthermia at electromagnetic radiation frequencies higher than 7 GHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precision ephemerides for gravitational-wave searches. I. Sco X-1

Rapidly rotating neutron stars are the only candidates for persistent high-frequency gravitational wave emission, for which a targeted search can be performed based on the spin period measured from electromagnetic (e.g., radio and X-ray) observations. The principal factor determining the sensitivity of such searches is the measurement precision of the physical parameters of the system. Neutron stars in X-ray binaries present additional computational demands for searches due to the uncertainty in the binary parameters. We present the results of a pilot study with the goal of improving the measurement precision of binary orbital parameters for candidate gravitational wave sources. We observed the optical counterpart of Sco X-1 in 2011 June with the William Herschel Telescope and also made use of Very Large Telescope observations in 2011 to provide an additional epoch of radial-velocity measurements to earlier measurements in 1999. From a circular orbit fit to the combined data set, we obtained an improvement of a factor of 2 in the orbital period precision and a factor of 2.5 in the epoch of inferior conjunction T {sub 0}. While the new orbital period is consistent with the previous value of Gottlieb et al., the new T {sub 0} (and the amplitude of variation of the Bowen line velocities) exhibited a significant shift, which we attribute to variations in the emission geometry with epoch. We propagate the uncertainties on these parameters through to the expected Advanced LIGO-Virgo detector network observation epochs and quantify the improvement obtained with additional optical observations.

79 ASTRONOMY AND ASTROPHYSICS↗