Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ECCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Simulation and Analysis on Reactor Pressure Vessel (RPV) subjected to Pressurized Thermal Shock (PTS) under SBLOCA scenario by using Cardinal to support the fracture mechanics analyses

The structural components that comprise nuclear reactors and their supporting structures are subjected to harsh operating environments that can challenge their integrity, especially after exposure for extended durations or under accident condition. As one of the most significant components of a Reactor, the Reactor Pressure Vessel (RPV) is exposed to an aggressive environment during the operation time (e.g. more than 40 years). Ageing degradation mechanisms (e.g. thermos-fatigue) could grow initial defects up to a critical size, increasing the susceptibility to failure in the RPV. The conventional methods are mostly based on simple crack and structure geometries. Very limited studies consider the real conditions of the RPV subjected to a thermal shock due to a Loss of Coolant Accident (LOCA). During a LOCA event, the most severe conditions take place when the emergency core cooling (ECC) water is injected inside the cold legs filled initially with hotter water and/or steam. The rapid cooling of the down-comer and the internal RPV surface followed probably by re-pressurization of the RPV causes large temperature gradients and variation of pressure which induces thermal-mechanical stresses. In order to develop the model for integrity assessment of a reactor pressure vessel (RPV) subjected to pressurized thermal shock (PTS), a multi-physics simulation, which includes the thermo-hydraulic, thermo-mechanical and fracture mechanics analyses is necessary. The multi-physics simulations are performed using Cardinal, a wrapping of the GPU-oriented spectral element Computational Fluid Dynamics (CFD) code NekRS and other multi-physics sub-modules within the MOOSE framework. Cardinal now fully supports MOOSE stochastic perturbations of NekRS models with varying boundary conditions, initial conditions, material properties, and any other quantity which is defined by a kernel (such as coefficients in a momentum source model). The implementation is designed in a flexible manner so that scalar values are sent from MOOSE into a user scratch space in NekRS, which can then be applied for any purpose within the NekRS case files (both on the host and device). When modeling PTS, several factors can impact the results significantly. In this report, the impacts of the geometry of the model, Reynolds number and buoyancy effect are investigated. Two geometry, i.e., a simplified model and a realistic RPV model, with both laminar and turbulent flow condition are adopted for the PTS simulation with and without buoyancy effect. The purpose of the investigation is to understand the impact of these factors on the prediction of temperature history of RPV. The accurate prediction on the temperature evolution, which will be exported to Grizzly code for further analyses on the progression of aging mechanisms and their effects on the integrity of RPV structures, is very crucial. Based on the understanding of these factors, a more sophisticated model is built to analysis the PTS under SBLOCA scenario. A literature survey is conducted to pick the SBLOCA scenario for the multi-physics simulation. The analysis helps to explain the form and the transformation of the cold plum when the ECC is activated under SBLOCA. This model can be can be applied to study the PTS effect for different RPV configurations. The results can help to assess structural component degradation for advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Emerald Connections Weatherization Plus Health Pilot Program

The Emerald Connections Weatherization Plus Health Pilot Program (Healthy Homes Pilot or the pilot), delivered 97 comprehensive energy retrofits to low-income households in two underserved communities: Lynn, Massachusetts (57) and the Beacon Hill neighborhood in Seattle, Washington (40). Designed by Emerald Cities Collaborative (ECC) and funded via a U.S. Department of Energy (DOE) Weatherization Assistance Program (WAP) Enhancement and Innovation (E&I) grant, ECC created the pilot to expand the reach and range of services typically available to participating WAP households.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrochemical concentration cell ozonesonde performance evaluation

A large number of electrochemical concentration cell (EDD) ozonesondes were calibrated relative to ultraviolet photometric absorption (254 nm) to determine their precision and accuracy. The average agreement with UV photometry was found to be good, but with considerable variation from one ECC ozonesonde to another. Applying individual calibrations to vertical ozone profiles reduced the systematic differences between ECC ozonesonde total ozone values and Dobson spectrophotometric determinations of the same quantity, but did not improve random differences.

Torres, A. L.↗

Performance characteristics of the electrochemical concentration cell ozonesonde

A large number of electrochemical concentration cell (ECC) ozonesondes were calibrated in relation to a UV photometric absorption ozone instrument prior to using the ozonesondes in atmospheric soundings. The two methods of measuring ozone were in reasonable agreement on the average, but there was considerable variation from one ozonesonde to another. Averaging the individual linear regressions gives an ECC ozone concentration equal to 0 + or - 8 nbar plus (0.96 + or - 0.10) times the concentration determined with the UV instrument, where uncertainties represent 90% confidence limits. Applying individual calibration corrections to atmospheric sounding data reduced the mean difference between Dobson spectrophotometric measurements of total ozone overburdens and corresponding values obtained from ozonesonde data from -8.5 + or - 8.2 to -1.4 + or - 7.3% for a series of measurements carried out in 1977. Corresponding uncorrected and corrected differences averaged 3.2 + or - 9.7 and 1.9 + or - 10.6%, respectively, for soundings carried out in 1976.

Torres, A. L.↗

An evaluation of electrochemical concentration cell sonde measurements of atmospheric ozone

Using Dobson spectrophotometer measurements of total ozone as a comparison, an analysis of the Electrochemical Concentration Cell (ECC) ozonesonde's measurement accuracy is presented. Days of conjunctive ECC-Dobson observations (from 1970 to 1976 at Wallops Flight Center) provide a set of 123 pairs of total ozone values. Sample set statistics are generated with means and standard deviations of total ozone values and differences being noted. An in-depth study of factors such as time differences between associated observations, integration techniques used, assumptions used in calculating residual ozone and other possible sources of errors are examined. Short-period changes in total ozone using Dobson data during the observational period are also described.

Geraci, M. J.↗

Correlative Measurements Program

The GSFC Correlative Measurements Program at the Wallops Flight Facility was represented on the Satellite/Satellite Intercomparisons Working Group. The Correlative Measurements Program uses the Rocket Ozonesonde (ROCOZ-A) and the Electrochemical Concentration Cell (ECC) balloon borne ozonesonde to measure the vertical profile of ozone amount in the atmosphere. The balloon work is described in a separate report. The ROCOZ-A instrument was used for many years to provide in situ truth data for various satellite ozone measuring systems, such as SBUV on Nimbus-7, SAGE-II, SBUV-II on the NOAA series of polar orbiting satellites, SME, LIMS, etc. The particular data sets of interest to the Ozone Trends Panel Working Group were collected at Natal, Brazil. The major results produced for and used by the Ozone Trends Panel are shown. The ROCOZ-A average ozone density profile is plotted versus altitude on the left. ECC ozonesondes were used for the portion of the profile below 20 km, the lower limit for ROCOZ-A. The difference between SAGE-II and ROCOZ-A average density profiles is shown.

Parsons, C. L.↗

Compact disk error measurements

The objectives of this project are as follows: provide hardware and software that will perform simple, real-time, high resolution (single-byte) measurement of the error burst and good data gap statistics seen by a photoCD player read channel when recorded CD write-once discs of variable quality (i.e., condition) are being read; extend the above system to enable measurement of the hard decision (i.e., 1-bit error flags) and soft decision (i.e., 2-bit error flags) decoding information that is produced/used by the Cross Interleaved - Reed - Solomon - Code (CIRC) block decoder employed in the photoCD player read channel; construct a model that uses data obtained via the systems described above to produce meaningful estimates of output error rates (due to both uncorrected ECC words and misdecoded ECC words) when a CD disc having specific (measured) error statistics is read (completion date to be determined); and check the hypothesis that current adaptive CIRC block decoders are optimized for pressed (DAD/ROM) CD discs. If warranted, do a conceptual design of an adaptive CIRC decoder that is optimized for write-once CD discs.

Howe, D.↗

Determining the locations of the various CIRC recording format information blocks (user data blocks, C2 and C1 words and EFM frames) on a recorded compact disc

Just prior to its being EFM modulated (i.e., converted to eight-to-fourteen channel data by the EFM encoder) and written to a Compact Disc (CD), information that passes through the CIRC Block Encoder is grouped into 33-byte blocks referred to as EFM frames. Twenty four of the bytes that make up a given EFM frame are user data that was input into the CIRC encoder at various (different) times, 4 of the bytes of this same EFM frame were created by the C2 ECC encoder (each at a different time), and another 4 were created by the C1 ECC encoder (again, each at a different time). The one remaining byte of the given EFM frame, which is known as the EFM frame C&D (for Control & Display) byte, carries information that identifies which portion of the current disc program track the given EFM frame belongs to and also specifies the location of the given EFM frame on the disc (in terms of a time stamp that has a resolution of l/75th second, or 98 EFM frames). (Note: since the program track and time information is stored as a 98-byte word, a logical group consisting of 98 consecutive EFM frames must be read, and their respective C&D bytes must be catenated and decoded, before the program track identification and time position information that pertains to the entire block of 98 EFM frames can be obtained.) The C&D byte is put at the start (0th byte) of an EFM frame in real time; its placement completes the construction of the EFM frame - it is assigned just before the EFM frame enters the EFM encoder. Four distinct blocks of data are referred to: 24-byte User Input Data Blocks; 28-byte C2 words; 32-byte C1 words; and 33-byte EFM frames.

Howe, Dennis G.↗

Volcanic-aerosol-induced changes in stratospheric ozone following the eruption of Mount Pinatubo

Measurements of lower stratospheric ozone in the Tropics using electrochemical concentrations cell (ECC) sondes and the airborne UV Differential Absorption Lidar (DIAL) system after the eruption of Mt. Pinatubo are compared with the Stratospheric Aerosol and Gas Experiment 2 (SAGE 2) and ECC sonde measurements from below the eruption to determine what changes have occurred as a result. Aerosol data from the Advanced Very High Resolution Radiometer (AVHRR) and the visible and IR wavelengths of the lidar system are used to examine the relationship between aerosols and ozone changes. Ozone decreases of 30 percent at altitudes between 19 and 26 km, partial column (16-28 km) decreases of about 27 D.U., and slight increases (5.4 D.U.) between 28 and 31 km are found in comparison with SAGE 2 climatological values.

Grant, W. B.↗

Aerosol-associated changes in tropical stratospheric ozone following the eruption of Mount Pinatubo

The large amount of sulfuric acid aerosol formed in the stratosphere by conversion of sulfur dioxide emitted by the eruption of Mount Pinatubo (15.14 deg N, 120.35 deg E) in the Philippines around June 15, 1991, has had a pronounced effect on lower stratospheric ozone in the tropics. Measurements of stratospheric ozone in the tropics using electrochemical concentration cell (ECC) sondes before and after the eruption and the airborne UV differential absorption lidar (DIAL) system after the eruption are compared with Stratospheric Aerosol and Gas Experiment II (SAGE II) measurements from several years before the eruption and ECC sonde measurements from the year prior to the eruption to determine the resulting changes. Ozone decreases of up to 33 % compared with SAGE II climatological values were found to be directly correlated with altitude regions of enhanced aerosol loading in the 16- to 28-km range. A maximum partial-column decrease of 29 +/- Dobson units (DU) was found over the 16- to 28-km range in September 1991 along with small increases (to 5.9 +/- 2 DU) from 28 to 31.5 km. A large decrease of ozone was also found at 4 deg to 8 deg S from May to August 1992, with a maximum decrease of 33 +/- 7 DU found above Brazzaville in July. Aerosol data form the visible channel of the advanced very high resolution radiometer (AVHRR) and the visible wavelength of the UV DIAL system were used to examine the relationship between aerosol (surface area) densities and ozone changes. The tropical stratospheric ozone changes we observed in 1991 and 1992 are likely be explained by a combination of dynamical (vertical transport) perturbations, radiative perturbations on ozone photochemistry, and heterogeneous chemistry.

Grant, William B.↗

Statistical Mining of Predictability of Seasonal Precipitation over the United States

Results from a new ensemble canonical correlation (ECC) prediction model yield a remarkable (10-20%) increases in baseline prediction skills for seasonal precipitation over the US for all seasons, compared to traditional statistical predictions. While the tropical Pacific, i.e., El Nino, contributes to the largest share of potential predictability in the southern tier States during boreal winter, the North Pacific and the North Atlantic are responsible for enhanced predictability in the northern Great Plains, Midwest and the southwest US during boreal summer. Most importantly, ECC significantly reduces the spring predictability barrier over the conterminous US, thereby raising the skill bar for dynamical predictions.

Lau, William K. M.↗

A Characterization of Vertical Ozonesonde Measurements at the Equatorial Locations of SHADOZ

Beginning in 1997 ozonesonde observations have been obtained from Equatorial locations participating in SHADOZ (Southern Hemisphere Additional Ozone) Project. Vertical ozone profiles are available from the western Pacific eastward to Kenya. Presently 10 stations provide vertical ECC ozonesonde measurements at least weekly. Statistical analysis shows the variation that occurs in the level of maximum ozone, the difference between integrated total ozone overburden from ECC and EP-TOMS observations, and with Dobson Spectrophotometers, when data are available.

Schmidlin, F. J.↗

A Balloon Sounding Technique for Measuring SO2 Plumes

This paper reports on the development of a new technique for inexpensive measurements of SO2 profiles using a modified dual-ozonesonde instrument payload. The presence of SO2 interferes with the standard electrochemical cell (ECC) ozonesonde measurement, resulting in -1 molecule of O3 reported for each molecule of SO2 present (provided [O3] > [SO2]). In laboratory tests, an SO2 filter made with Cr03 placed on the inlet side of the sonde removes nearly 100% of the SO2 present for concentrations up to 60 ppbv and remained effective after exposure to 2.8 X 10(exp 16) molecules of SO2 [equivalent to a column approximately 150 DU (1 DU = 2.69 X 10(exp 20) molecules m(exp -2))]. Flying two ECC instruments on the same payload with one filtered and the other unfiltered yields SO2 profiles, inferred by subtraction. Laboratory tests and field experience suggest an SO2 detection limit of approximately 3 pbb with profiles valid from the surface to the ozonopause [i.e., approximately (8-10 km)]. Two example profiles demonstrate the success of this technique for both volcanic and industrial plumes.

Morris, Gary A.↗

Optimizing Parameters for Deep-Space Optical Communication

A paper discusses the optimization of the parameters of a high-rate, deep-space optical communication link that utilizes pulse-position modulation (PPM) and an error-correcting code (ECC). The parameters in question include the PPM order (number of pulse time slots in one symbol period), the ECC rate, and the uncoded symbol error rate. In simple terms, the optimization problem is to choose the combination of these parameters that maximizes the throughput data rate at a given bit-error-rate (BER), subject to several constraints, including limits on the average and peak power and possibly a limit on the uncoded symbol error rate. This is a complex, multidimensional optimization problem, the solution of which involves computation of channel capacities for various combinations of the parameters. The paper presents extensive theoretical analyses and numerical predictions that elucidate the many facets of the optimization problem. It shows how a nearly optimum solution can be obtained by choosing the optimum PPM order for the desired number of bits per slot and concatenating the PPM mapping with an error-correction code so that the decoded bits satisfy some BER threshold.

Moison, Bruce↗

Propagation of Radiosonde Pressure Sensor Errors to Ozonesonde Measurements

Several previous studies highlight pressure (or equivalently, pressure altitude) discrepancies between the radiosonde pressure sensor and that derived from a GPS flown with the radiosonde. The offsets vary during the ascent both in absolute and percent pressure differences. To investigate this problem further, a total of 731 radiosonde-ozonesonde launches from the Southern Hemisphere subtropics to Northern mid-latitudes are considered, with launches between 2005 - 2013 from both longer-term and campaign-based intensive stations. Five series of radiosondes from two manufacturers (International Met Systems: iMet, iMet-P, iMet-S, and Vaisala: RS80-15N and RS92-SGP) are analyzed to determine the magnitude of the pressure offset. Additionally, electrochemical concentration cell (ECC) ozonesondes from three manufacturers (Science Pump Corporation; SPC and ENSCI-Droplet Measurement Technologies; DMT) are analyzed to quantify the effects these offsets have on the calculation of ECC ozone (O3) mixing ratio profiles (O3MR) from the ozonesonde-measured partial pressure. Approximately half of all offsets are 0.6 hPa in the free troposphere, with nearly a third 1.0 hPa at 26 km, where the 1.0 hPa error represents 5 persent of the total atmospheric pressure. Pressure offsets have negligible effects on O3MR below 20 km (96 percent of launches lie within 5 percent O3MR error at 20 km). Ozone mixing ratio errors above 10 hPa (30 km), can approach greater than 10 percent ( 25 percent of launches that reach 30 km exceed this threshold). These errors cause disagreement between the integrated ozonesonde-only column O3 from the GPS and radiosonde pressure profile by an average of +6.5 DU. Comparisons of total column O3 between the GPS and radiosonde pressure profiles yield average differences of +1.1 DU when the O3 is integrated to burst with addition of the McPeters and Labow (2012) above-burst O3 column climatology. Total column differences are reduced to an average of -0.5 DU when the O3 profile is integrated to 10 hPa with subsequent addition of the O3 climatology above 10 hPa. The RS92 radiosondes are superior in performance compared to other radiosondes, with average 26 km errors of -0.12 hPa or +0.61 percent O3MR error. iMet-P radiosondes had average 26 km errors of -1.95 hPa or +8.75 percent O3MR error. Based on our analysis, we suggest that ozonesondes always be coupled with a GPS-enabled radiosonde and that pressure-dependent variables, such as O3MR, be recalculated-reprocessed using the GPS-measured altitude, especially when 26 km pressure offsets exceed 1.0 hPa 5 percent.

pressure measurements↗

Ozonesonde Quality Assurance: JOSIE-SHADOZ (2017) and SHALLOTS (2018)

Ozonesonde data constitute a mainstay of satellite calibration and are used for climatologies and analysis of trends, especially in the lower stratosphere where satellites are most uncertain. The electrochemical-concentration cell (ECC) ozonesonde has been deployed at ~100 stations worldwide since the 1960s, with changes over time in manufacture and procedures, including details of the cell chemical solution and data processing. As a consequence, there are biases among different stations and discontinuities in profile timeseries from individual site records. Since 1996 the Jülich [Germany] Ozone Sonde Intercomparison Experiment (JOSIE) has periodically tested ozonesondes in a simulation chamber designated the World Calibration Centre for Ozonesondes by WMO. In October- November 2017 a JOSIE campaign evaluated the sondes and procedures used in SHADOZ (Southern Hemisphere Additional Ozonesondes), a 14-station tropical and subtropical network. A distinctive feature of the 2017 JOSIE was that the tests were conducted by operators from eight SHADOZ stations; Nairobi, Natal, Irene, Costa Rica, Paramaribo, Reunion, Hanoi, Kuala Lumpur. Experimental protocols and preliminary results for the SHADOZ sonde configurations, which represent most of those in use today, are described. SHADOZ stations that follow WMO-recommended protocols record total ozone within 3% of the JOSIE reference instrument. Instrument biases noted in prior JOSIE and field tests like BESOS (2004) were noted in JOSIE-2017, with maximum effect in the stratosphere. In June 2018 we organized a series of dual launches during the OWLETS II campaign in the Maryland and Chesapeake Bay area (SHALLOTS = SHADOZ-OWLETS ParaLLel Ozonesonde Test Study). Instrument and solution types were varied as in JOSIE-2017 and three radiosonde-ozonesonde variants were tested. An example of a parallel sampling in SHALLOTS, from a Greenbelt EnSCI-iMet sonde combination flown with the Wallops SPCLMS package, is illustrated in the Figure. The result was a range of biases but in general the instrument combination (EnSCI-iMet) deployed at 11 SHADOZ stations recorded ~5-10% less ozone in the stratosphere than the SPC ECC sonde flown with a Vaisala or LMS system. These 2017 and 2018 results and prior JOSIEs demonstrate that regular testing is essential to maintain best practices in ozonesonde operations and to ensure high-quality data for the ozone assessment communities.

Quality assurance↗

Passive techniques for long-term reactor cooling

In a pressurized water reactor (PWR), emergency core cooling (ECC) responds to depressurization due to a vessel penetration break at the top of the pressure vessel by draining water from a body of water through an injection line into the pressure vessel. A barrier operates concurrently with the ECC to suppress flow of liquid water from the pressure vessel out the vessel penetration break. The barrier may comprise one or more of: (1) an injection line extension passing through the central riser to drain water into the central riser; (2) openings in a lower portion of a central riser to shunt some upward flow from the central riser into a lower portion of the downcomer annulus; and (3) a surge line providing fluid communication between a pressurizer volume at the top of the pressure vessel and the remainder of the pressure vessel which directs water outboard toward the downcomer annulus.

Malloy, III, John D.↗

Evaluating direct vessel injection accident-event progression of AP1000 and key figures of merit to support the design and development of water-cooled small modular reactors

The passive safety systems (PSSs) within water-cooled reactors are meticulously engineered to function autonomously, requiring no external power source or manual intervention. They depend exclusively on inherent natural forces and the fundamental principles of reactor physics, such as gravity, natural convection, and phase changes, to manage, alleviate, and avert the release of radioactive materials into the environment during accident scenarios like a loss-of-coolant accident (LOCA). PSSs are already integrated into such operating commercial reactors as the Advanced Pressurized Reactor-1000 MWe (AP1000) and the Water-Water Energetic Reactor-1200 MWe (WWER-1200) are adopted in most of the upcoming small modular reactor (SMR) designs. Examples of water-cooled SMR PSSs are the passive emergency core-cooling system (ECCS), passive containment cooling system (PCCS), and passive decay-heat removal system, the designs of which vary based on reactor system-design requirements. However, understanding the accident-event progression and phases of a LOCA is pivotal for adopting a specific PSS for a new SMR design. This study covers the accident-event progression for direct vessel injection (DVI) small-break loss-of-coolant accident (SB-LOCA), associated physics phenomena, knowledge gaps, and important figures of merit (FOMs) that may need to be evaluated and assessed to validate thermal-hydraulics models with an available experimental dataset to support new SMR design and development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗