Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ECC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Vertical ozone profile comparisons between ozonesondes and remote instrumentation

The ozone profiles measured with the halogen occultation experiment (HALOE) instrument and the microwave limb sounder (MLS) instrument, on NASA's upper atmosphere research satellite (UARS), are compared to those obtained with the electrochemical concentration cell (ECC) ozone sonde. The process used to assure the quality of the ozone sonde measurements, the comparisons between the ozone sonde and other measuring instruments, and the reliability of measurements in space are discussed.

Schmidlin, F. J.↗

Results from the 1995 Stratospheric Ozone Profile Intercomparison at Mauna Loa (MLO3)

In August 1995 multiple instruments that measure the stratospheric ozone vertical distribution were intercompared at the Mauna Loa Observatory, Hawaii, under the auspices of the Network for the Detection of Stratospheric Change. The instruments included two UV lidar systems, one from JPL and the other from Goddard Space Flight Center, ECC balloon-sondes, a ground-based microwave instrument, Umkehr measurements, and a new ground-based FTIR instrument. The MLS instrument on the UARS satellite provided correlative profiles of ozone, and there was one close overpass of the SAGE II instrument. The results show that much better consistency among instruments is being achieved than even a few years ago, usually to within the instrument uncertainties. The different measurement techniques in this comparison agree to within +/-10% at almost all altitudes, and in the 20 km to 45 km region most agreed within +/-5%. The results show that the current generation of lidars are capable of accurate measurement of the ozone profile to a maximum altitude of 50 km. SAGE agreed well with both lidar and balloon-sonde down to at least 17 km. The ground-based microwave measurement agreed with other measurements from 22 km to above 50 km. One minor source of disagreement continues to be the pressure-altitude conversion needed to compare a measurement of ozone density versus altitude with a measurement of ozone mixing ratio versus pressure.

McPeters, R. D.↗

Team Training and Retention of Skills Acquired Above Real Time Training on a Flight Simulator

Above Real-Time Training (ARTT) is the training acquired on a real time simulator when it is modified to present events at a faster pace than normal. The experiments related to training of pilots performed by NASA engineers (Kolf in 1973, Hoey in 1976) and others (Guckenberger, Crane and their associates in the nineties) have shown that in comparison with the real time training (RTT), ARTT provides the following benefits: increased rate of skill acquisition, reduced simulator and aircraft training time, and more effective training for emergency procedures. Two sets of experiments have been performed; they are reported in professional conferences and the respective papers are included in this report. The retention of effects of ARTT has been studied in the first set of experiments and the use of ARTT as top-off training has been examined in the second set of experiments. In ARTT, the pace of events was 1.5 times the pace in RTT. In both sets of experiments, university students were trained to perform an aerial gunnery task. The training unit was equipped with a joystick and a throttle. The student acted as a nose gunner in a hypothetical two place attack aircraft. The flight simulation software was installed on a Universal Distributed Interactive Simulator platform supplied by ECC International of Orlando, Florida. In the first set of experiments, two training programs RTT or ART7 were used. Students were then tested in real time on more demanding scenarios: either immediately after training or two days later. The effects of ARTT did not decrease over a two day retention interval and ARTT was more time efficient than real time training. Therefore, equal test performance could be achieved with less clock-time spent in the simulator. In the second set of experiments three training programs RTT or ARTT or RARTT, were used. In RTT, students received 36 minutes of real time training. In ARTT, students received 36 minutes of above real time training. In RARTT, students received 18 minutes of real time training and 18 minutes of above real time training as top-off training. Students were then tested in real time on more demanding scenarios. The use of ARTT as top-off training after RTT offered better training than RTT alone or ARTT alone. It is, however, suggested that a similar experiment be conducted on a relatively more complex task with a larger sample of participants. Within the proposed duration of the research effort, the setting up of experiments and trial runs on using ARTT for team training were also scheduled but they could not be accomplished due to extra ordinary challenges faced in developing the required software configuration. Team training is, however, scheduled in a future study sponsored by NASA at Tuskegee University.

Ali, Syed Friasat↗

Crista Ozone Measurements/Validation

Seven days of global high resolution middle atmosphere ozone profiles have been measured by the CRyogenic Infrared Spectrometers and Telescopes for the Atmosphere (CRISTA) in November 1994. Measurements cover the altitude range from 10 to 80 km and latitudes from 59 deg S to 64 deg N. An example of a global ozone map is presented and demonstrates the ability of the instrument to detect medium and even small scale structures. Comparisons with ECC- and Brewer Mast balloon-sonde underflights are discussed. Reasonable agreement between CRISTA and balloon-sondes is found especially in the altitude interval between about 19 km and 27 km.

Bittner, M.↗

Vertical Ozone Profile Comparisons Between Ozonesondes and Remote Instrumentation

Ozonesonde measurement quality is a critical factor for insuring measurement accuracy and is fundamentally indispensable for validating remotely measured ozone. Reasonable results from such ozone profile comparisons are best obtained by maintaining the smallest possible spatial and time differences between ozonesonde and remote measurement observations. Ozone profiles measured with the Halogen Occultation Experiment (HALOE) instrument and the Microwave Limb Sounder (MLS) instrument on NASA's Upper Atmosphere Research Satellite (UARS) are compared with ECC profiles. Comparisons with the GSFC ozone lidar also demonstrate good agreement. In this paper we show: (1) the process used by NASA to secure quality ozonesonde measurements, (2) comparisons of ozonesondes with various remote sensing instruments and, (3) the reliability obtained when both measurement types are obtained close in time and, when possible, in space.

Schmidlin, F. J.↗

SHADOZ (Southern Hemisphere ADditional OZonesondes): An Ozonesonde Network for Satellite Validation, Climatology and Modeling

In the past 5 years, new tropical ozone data products have been developed from TOMS and other satellites, During this period, global chemical-transport models have been used for ozone assessment studies. However, there has been a lack of independent ozone profiles in the tropics for evaluation of the data sets and models. In 1998, NASA's Goddard Space Flight Center, Wallops Flight Facility and NOAA's CMDL (Climate Monitoring and Diagnostics Lab), began a 2-year project to collect a consistent data set by augmenting ozonesonde launches at southern hemisphere tropical sites The measurements are available to the scientific community at a single electronic location - the SHADOZ website at NASA/Goddard: http://code9l6.gsfc.nasa.gov/Data services/Shadoz/shadoz hmpg2.html. Stations in SHADOZ include four islands in the Pacific: Fiji, Tahiti, San Cristobal (Galapagos) and American Samoa. Two sites are at and in the Atlantic: Natal (Brazil) and Ascension Island. Three other sites span Africa (Nairobi and Irene, South Africa) and the Indian Ocean (Reunion Island and Watukosek in Java, Indonesia). All SHADOZ sites are using ECC-type sondes, with the conversion from JMD sondes at Java in 1999, but there are variations in sonde preparation technique and data processing. During the 1998-1999 period, more than 550 sondes were incorporated into the SHADOZ data base. Examples from these measurements illustrate the tropical wave-one pattern in total ozone which is easily detectable by satellite. They also show that the wave-one pattern appears to be in the troposphere, as assumed in creating the modified-residual tropospheric ozone data product from TOMS. SHADOZ will add data from intensive field campaigns from time to time. Recent contributions to the SHADOZ archive are from the INDOEX (Indian Ocean Experiment January-March 1999)sondes at the Maldives (5N, 73E) and 27 sondes on the US NOAA oceanographic vessel, the FIN Ronald H Brown between Virginia (US) and Mauritius via CapeTown, during a cruise in January and February 1999. In 2000, as part of the SAFARI-2000 experiment and a validation project called Southern African Validation for EOS (SAVE), enhancement of ozonesonde launches at Irene (South Africa) will extend the data set from this site beyond the 1998-1999 period.

Thompson, Anne M.↗

The 1998-2000 SHADOZ (Southern Hemisphere ADditional Ozonesondes) Tropical Ozone Climatology: Comparison with TOMS and Ground-Based Measurements

A network of 10 southern hemisphere tropical and Subtropical stations, designated the Southern Hemisphere ADditional OZonesondes, (SHADOZ) project and established from operational sites, provided over 1000 ozone profiles during the period 1998-2000. Balloon-borne electrochemical concentration cell (ECC) ozonesondes, combined with standard radiosondes for pressure, temperature and relative humidity measurements, collected profiles in the troposphere and lower- to mid-stratosphere at: Ascension Island; Nairobi, Kenya; Irene, South Africa: Reunion Island, Watukosek Java; Fiji; Tahiti; American Samoa; San Cristobal, Galapagos; Natal, Brazil.

Thompson, Anne M.↗

Balloon Borne Soundings of Water Vapor, Ozone and Temperature in the Upper Tropospheric and Lower Stratosphere as Part of the Second SAGE III Ozone Loss and Validation Experiment (SOLVE-2)

The main goal of our work was to provide in situ water vapor and ozone profiles in the upper troposphere and lower stratosphere as reference measurements for the validation of SAGE III water vapor and ozone retrievals. We used the NOAA/CMDL frost point hygrometer and ECC ozone sondes on small research balloons to provide continuous profiles between the surface and the mid stratosphere. The NOAA/CMDL frost point hygrometer is currently the only lightweight balloon borne instrument capable of measuring water vapor between the lower troposphere and middle stratosphere. The validation measurements were based in the arctic region of Scandinavia for northern hemisphere observations and in New Zealand for southern hemisphere observations and timed to coincide with overpasses of the SAGE III instrument. In addition to SAGE III validation we also tried to coordinate launches with other instruments and studied dehydration and transport processes in the Arctic stratospheric vortex.

Voemel, Holger↗

Accuracy and Precision in the Southern Hemisphere Additional Ozonesondes (SHADOZ) Dataset 1998-2000 in Light of the JOSIE-2000 Results

A network of 12 southern hemisphere tropical and subtropical stations in the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has provided over 2000 profiles of stratospheric and tropospheric ozone since 1998. Balloon-borne electrochemical concentration cell (ECC) ozonesondes are used with standard radiosondes for pressure, temperature and relative humidity measurements. The archived data are available at:http: //croc.gsfc.nasa.gov/shadoz. In Thompson et al., accuracies and imprecisions in the SHADOZ 1998- 2000 dataset were examined using ground-based instruments and the TOMS total ozone measurement (version 7) as references. Small variations in ozonesonde technique introduced possible biases from station-to-station. SHADOZ total ozone column amounts are now compared to version 8 TOMS; discrepancies between the two datasets are reduced 2\% on average. An evaluation of ozone variations among the stations is made using the results of a series of chamber simulations of ozone launches (JOSIE-2000, Juelich Ozonesonde Intercomparison Experiment) in which a standard reference ozone instrument was employed with the various sonde techniques used in SHADOZ. A number of variations in SHADOZ ozone data are explained when differences in solution strength, data processing and instrument type (manufacturer) are taken into account.

Witte, J. C.↗

Variability in Tropical Tropospheric Ozone as Observed by SHADOZ

The SHADOZ (Southern Hemisphere Additional Ozonesondes) ozone sounding network was initiated in 1998 to improve the coverage of tropical in-situ ozone measurements for satellite validation, algorithm development and related process studies. Over 2000 soundings have been archived at the central website, , for 12 stations: Ascension Island; Nairobi and Malindi, Kenya; Irene, South Africa; Reunion Island; Watukosek, Java; Fiji; Tahiti; American Samoa; San Cristobal, Galapagos; Natal, Brazil; Paramaribo, Surinam. Some results to date indicate reliability of the measurement and highly variable interactions between ozone and tropical meteorology. For example: 1. By using ECC sondes with similar procedures, 5-10% accuracy and precision (1-sigma) of the sonde total ozone measurement was achieved [Thompson et al., 2003al; 2. Week-to-week variability in tropospheric ozone is so great that statistics are frequently not Gaussian and most stations vary up to a factor of 3 in column amount over the course of a year [Thompson et al., 2002b]. 3. Longitudinal variability in tropospheric ozone profiles is a consistent feature, with a 10- 15 DU column-integrated difference between Atlantic and Pacific sites; this is the cause of the zonal wave-one feature in total ozone [Shiotani, 1992]. The ozone record from Paramaribo, Surinam (6N, 55W) is a marked contrast to southern tropical ozone because Surinam is often north of the Intertropical Convergence Zone. Interpretations of SHADOZ time-series and approaches to classification suggested by SHADOZ data over Africa and the Indian Ocean will be described.

Thompson, Anne M.↗

Changes in autonomic activity preceding onset of nonsustained ventricular tachycardia

Background: The triggering role of the autonomic nervous system in the initiation of ventricular tachycardia has not been established. To investigate the relationship between changes in autonomic activity and the occurrence of nonsustained ventricular tachycardia (NSVT) we examined heart rate variability (HRV) during the 2-hour period preceding spontaneous episodes of NSVT. Twenty-four subjects were identified retrospectively as having had one episode of NSVT during 24-hour Holter ECC recording. Methods: We measured the mean interval between normal heats (meanRR), the standard deviation of the intervals between beats (SD), the percentage of counts of sequential intervals between normal beats with a change of >50 ms (%RR50), the logarithms of low- and high-frequency spectral components (lnLF, lnHF) of HRV for sequential 10-minute segments preceding NSVT. The correlation dimension (CDim) of HRV was calculated similarly for sequential 20-minute segments. We assessed the significance of the time-course change of each marker over the 120-minute period prior to NSVT onset. Results: MeanRR (P < 0.05), lnLF (P < 0.0001), lnHF (P < 0.0001), the natural logarithm of the ratio of LF to HF (ln[LF/HF]; P < 0.05), and CDim (P < 0.05) showed significant time-course changes during that period, while SD and %RR50 did not. MeanRR, lnLF, lnHF, and CDim all decreased prior to the onset of NSVT, whereas ln(LF/HF) increased. We divided the subjects into two groups: one consisting of 12 patients with coronary artery disease; and the second group of 12 patients without known coronary artery disease. Both groups showed significant changes (P < 0.05) of CDim, lnLF, and lnHF preceding the episodes of NSVT. Conclusions: Changes in the pattern of HRV prior to the onset of episodes of NSVT suggest that changes in autonomic activity may commonly play a role in the triggering of spontaneous episodes of NSVT in susceptible patients. The measured changes suggest a reduction in parasympathetic activity, perhaps in conjunction with an increase in sympathetic activity, may trigger NSVT.

Non-NASA Center↗

A bioreactor system for the nitrogen loop in a Controlled Ecological Life Support System

As space missions become longer in duration, the need to recycle waste into useful compounds rises dramatically. This problem can be addressed by the development of Controlled Ecological Life Support Systems (CELSS) (i.e., Engineered Closed/Controlled Eco-Systems (ECCES)), consisting of human and plant modules. One of the waste streams leaving the human module is urine. In addition to the reclamation of water from urine, recovery of the nitrogen is important because it is an essential nutrient for the plant module. A 3-step biological process for the recycling of nitrogenous waste (urea) is proposed. A packed-bed bioreactor system for this purpose was modeled, and the issues of reaction step segregation, reactor type and volume, support particle size, and pressure drop were addressed. Based on minimization of volume, a bioreactor system consisting of a plug flow immobilized urease reactor, a completely mixed flow immobilized cell reactor to convert ammonia to nitrite, and a plug flow immobilized cell reactor to produce nitrate from nitrite is recommended. It is apparent that this 3-step bioprocess meets the requirements for space applications.

NASA Discipline Number 61-10↗

Accuracy and Precision in the Southern Hemisphere Additional Ozonesondes (SHADOZ) Dataset in Light of the JOSIE-2000 Results

Since 1998 the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has provided over 2000 ozone profiles over eleven southern hemisphere tropical and subtropical stations. Balloon-borne electrochemical concentration cell (ECC) ozonesondes are used to measure ozone. The data are archived at: &ttp://croc.gsfc.nasa.gov/shadoz>. In analysis of ozonesonde imprecision within the SHADOZ dataset, Thompson et al. [JGR, 108,8238,20031 we pointed out that variations in ozonesonde technique (sensor solution strength, instrument manufacturer, data processing) could lead to station-to-station biases within the SHADOZ dataset. Imprecisions and accuracy in the SHADOZ dataset are examined in light of new data. First, SHADOZ total ozone column amounts are compared to version 8 TOMS (2004 release). As for TOMS version 7, satellite total ozone is usually higher than the integrated column amount from the sounding. Discrepancies between the sonde and satellite datasets decline two percentage points on average, compared to version 7 TOMS offsets. Second, the SHADOZ station data are compared to results of chamber simulations (JOSE-2000, Juelich Ozonesonde Intercomparison Experiment) in which the various SHADOZ techniques were evaluated. The range of JOSE column deviations from a standard instrument (-10%) in the chamber resembles that of the SHADOZ station data. It appears that some systematic variations in the SHADOZ ozone record are accounted for by differences in solution strength, data processing and instrument type (manufacturer).

Witte, Jacquelyn C.↗

The Validation of Version 8 Ozone Profiles: Is SBUV Ready for Prime Time?

Ozone profile data are now available from a series of BUV instruments - SBUV on Nimbus 7 and SBW/2 instruments on NOAA 9, NOAA 11, and NOAA 16. The data have been processed through the new version 8 algorithm, which is designed to be more accurate and, more importantly, to reduce the influence of the a priori on ozone trends. As a part of the version 8 reprocessing we have attempted to apply a consistent calibration to the individual instruments so that their data records can be used together in a time series analysis. Validation consists of examining not only the mean difference from external datasets (i.e trends) but also consistency in the interannual variability of the data. Here we validate the v8 BUV data through comparison with ECC sondes, lidar and microwave measurements, and with SAGE II and HALOE satellite data records. We find that individual profiles generally agree with external data sets within +/-10% between 30 hPa and 1 hPa (approx. 24 - 50 km) and frequently agree within +/-5%. The interannual variability of the BUV ozone time series agrees well with that of SAGE II . On the average, different B W instruments usually agree within +/-5% with each other, though the relative error increases near the ends of the Nimbus 7 and NOAA 16 data records as a result of instrument problems. The combined v8 BUV data sets cover the 1979-2003 time period giving daily global coverage of the ozone vertical distribution to better accuracy than has ever been possible before.

McPeters, R. D.↗

SHADOZ (Southern Hemisphere Additional Ozonesondes): A Project Overview and New Insights on Tropical Tropospheric Ozone

The SHADOZ (Southern Hemisphere Additional Ozonesondes) ozone sounding network was initiated in 1998 to improve the coverage of tropical in-situ ozone measurements for satellite validation, algorithm development and related process studies. Over 2000 soundings have been archived at the website, http://croc.gsfc.nasa.gov/shadoz, for 12 stations: Ascension Island; Nairobi and Malindi, Kenya; Irene, South Africa; Reunion Island; Watukosek, Java; Fiji; Tahiti; American Samoa; San Cristobal, Galapagos; Natal, Brazil; Paramaribo, Surinam. Key results from SHADOZ will be described from among the following: 1) By using ECC sondes with similar procedures, 5-10% accuracy and precision (1-sigma) of the sonde total ozone measurement is achieved; 2) Week-to-week variability in tropospheric ozone is so great that statistics are frequently not Gaussian; most stations vary up to a factor of 3 in tropospheric column over the course of a year; 3) Longitudinal variability in tropospheric ozone profiles is a consistent feature, with a 10-15 DU column-integrated difference between Atlantic and Pacific sites; this causes a "zonal wave-one" feature in total ozone; 4) The ozone record from Paramaribo, Surinam (6N, 55W) is a marked contrast to southern tropical ozone because Surinam is often north of the Intertropical Convergence Zone.

Thompson, Anne M.↗

Vertical Profiling of Air Pollution at RAPCD

The interaction between local and regional pollution levels occurs at the interface of the Planetary Boundary Layer and the Free Troposphere. Measuring the vertical distribution of ozone, aerosols, and winds with high temporal and vertical resolution is essential to diagnose the nature of this interchange and ultimately for accurately forecasting ozone and aerosol pollution levels. The Regional Atmospheric Profiling Center for Discovery, RAPCD, was built and instrumented to address this critical issue. The ozone W DIAL lidar, Nd:YAG aerosol lidar, and 2.1 micron Doppler wind lidar, along with balloon- borne ECC ozonesondes form the core of the W C D instrumentation for addressing this problem. Instrumentation in the associated Mobile Integrated Profiling (MIPS) laboratory includes 91 5Mhz profiler, sodar, and ceilometer. The collocated Applied particle Optics and Radiometry (ApOR) laboratory hosts an FTIR along with MOUDI and optical particle counters. With MODELS-3 analysis by colleagues in the National Space Science and Technology Center on the UAH campus and the co- located National Weather Service Forecasting Office in Huntsville, AL we are developing a unique facility for advancing the state of the science of pollution forecasting.

Newchurch, Michael J.↗

The Southern Hemisphere Additional Ozonesondes (SHADOZ) 1998-2002 Tropical Ozone Climatology: Instrumentation and Station-to-Station Variability - 3

Abstract: Since 1998 the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has collected more than 2000 ozone profiles from a dozen tropical and subtropical sites using balloon-borne electrochemical concentration cell (ECC) ozonesondes. The data (with accompanying pressure-temperature-humidity soundings) are archived. Analysis of ozonesonde imprecision within the SHADOZ dataset revealed that variations in ozonesonde technique could lead to station-to-station biases in the measurements. In this paper imprecisions and accuracy in the SHADOZ dataset are examined in light of new data. When SHADOZ total ozone column amounts are compared to version 8 TOMS (2004 release), discrepancies between sonde and satellite datasets decline 1-2 percentage points on average, compared to version 7 TOMS. Variability among stations is evaluated using total ozone normalized to TOMS and results of laboratory tests on ozonesondes (JOSE-2O00, Julich Ozonesonde Intercomparison Experiment). Ozone deviations from a standard instrument in the JOSE flight simulation chamber resemble those of SHADOZ station data relative to a SHADOZ-defined climatological reference. Certain systematic variations in SHADOZ ozone profiles are accounted for by differences in solution composition, data processing and instrument (manufacturer). Instrument bias leads to a greater ozone measurement above 25 km over Nairobi and to lower total column ozone at three Pacific sites compared to other SHADOZ stations at 0-20 deg.S.

Thompson, Anne M.↗

New Insights on Tropical Ozone from SHADOZ (Southern Hemisphere Additional Ozonesondes) Profiles

The SHADOZ (Southern Hemisphere Additional Ozonesondes) ozone sounding network was initiated in 1998 to improve the coverage of tropical in-situ ozone measurements for satellite validation, algorithm development and related process studies. Over 2000 soundings have been archived at the website, , for 12 stations: Ascension Island; Nairobi and Malindi, Kenya; Irene, South Africa; Reunion Island, Watukosek, Java; Fiji; Tahiti; American Samoa; San Cristobal, Galapagos; Natal, Brazil; Paramaribo, Surinam. Key results from SHADOZ will be described from among the following: 1) By using ECC sondes with similar procedures, 5-10% accuracy and precision (1-sigma) of the sonde total ozone measurement was achieved; 2) Week-to-week variability in tropospheric ozone is so great that statistics are frequently not Gaussian; most stations vary up to a factor of 3 in tropospheric column over the course of a year; 3) Longitudinal variability in tropospheric ozone profiles is a consistent feature, with a 10-15 DU column-integrated difference between Atlantic and Pacific sites; this causes a "zonal wave-one" feature in total ozone. 4) The ozone record from Paramaribo, Surinam (6N, 55W) is a marked contrast to southern tropical ozone because Surinam is often north of the Intertropical Convergence Zone; 5) Indian Ocean region pollution may contribute up to half of the excess ozone observed in the south tropical Atlantic paradox in the December-January-February period of the year.

Thompson, Anne M.↗