Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ECC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Compact disk error measurements

The objectives of this project are as follows: provide hardware and software that will perform simple, real-time, high resolution (single-byte) measurement of the error burst and good data gap statistics seen by a photoCD player read channel when recorded CD write-once discs of variable quality (i.e., condition) are being read; extend the above system to enable measurement of the hard decision (i.e., 1-bit error flags) and soft decision (i.e., 2-bit error flags) decoding information that is produced/used by the Cross Interleaved - Reed - Solomon - Code (CIRC) block decoder employed in the photoCD player read channel; construct a model that uses data obtained via the systems described above to produce meaningful estimates of output error rates (due to both uncorrected ECC words and misdecoded ECC words) when a CD disc having specific (measured) error statistics is read (completion date to be determined); and check the hypothesis that current adaptive CIRC block decoders are optimized for pressed (DAD/ROM) CD discs. If warranted, do a conceptual design of an adaptive CIRC decoder that is optimized for write-once CD discs.

Howe, D.↗

Determining the locations of the various CIRC recording format information blocks (user data blocks, C2 and C1 words and EFM frames) on a recorded compact disc

Just prior to its being EFM modulated (i.e., converted to eight-to-fourteen channel data by the EFM encoder) and written to a Compact Disc (CD), information that passes through the CIRC Block Encoder is grouped into 33-byte blocks referred to as EFM frames. Twenty four of the bytes that make up a given EFM frame are user data that was input into the CIRC encoder at various (different) times, 4 of the bytes of this same EFM frame were created by the C2 ECC encoder (each at a different time), and another 4 were created by the C1 ECC encoder (again, each at a different time). The one remaining byte of the given EFM frame, which is known as the EFM frame C&D (for Control & Display) byte, carries information that identifies which portion of the current disc program track the given EFM frame belongs to and also specifies the location of the given EFM frame on the disc (in terms of a time stamp that has a resolution of l/75th second, or 98 EFM frames). (Note: since the program track and time information is stored as a 98-byte word, a logical group consisting of 98 consecutive EFM frames must be read, and their respective C&D bytes must be catenated and decoded, before the program track identification and time position information that pertains to the entire block of 98 EFM frames can be obtained.) The C&D byte is put at the start (0th byte) of an EFM frame in real time; its placement completes the construction of the EFM frame - it is assigned just before the EFM frame enters the EFM encoder. Four distinct blocks of data are referred to: 24-byte User Input Data Blocks; 28-byte C2 words; 32-byte C1 words; and 33-byte EFM frames.

Howe, Dennis G.↗

Volcanic-aerosol-induced changes in stratospheric ozone following the eruption of Mount Pinatubo

Measurements of lower stratospheric ozone in the Tropics using electrochemical concentrations cell (ECC) sondes and the airborne UV Differential Absorption Lidar (DIAL) system after the eruption of Mt. Pinatubo are compared with the Stratospheric Aerosol and Gas Experiment 2 (SAGE 2) and ECC sonde measurements from below the eruption to determine what changes have occurred as a result. Aerosol data from the Advanced Very High Resolution Radiometer (AVHRR) and the visible and IR wavelengths of the lidar system are used to examine the relationship between aerosols and ozone changes. Ozone decreases of 30 percent at altitudes between 19 and 26 km, partial column (16-28 km) decreases of about 27 D.U., and slight increases (5.4 D.U.) between 28 and 31 km are found in comparison with SAGE 2 climatological values.

Grant, W. B.↗

Aerosol-associated changes in tropical stratospheric ozone following the eruption of Mount Pinatubo

The large amount of sulfuric acid aerosol formed in the stratosphere by conversion of sulfur dioxide emitted by the eruption of Mount Pinatubo (15.14 deg N, 120.35 deg E) in the Philippines around June 15, 1991, has had a pronounced effect on lower stratospheric ozone in the tropics. Measurements of stratospheric ozone in the tropics using electrochemical concentration cell (ECC) sondes before and after the eruption and the airborne UV differential absorption lidar (DIAL) system after the eruption are compared with Stratospheric Aerosol and Gas Experiment II (SAGE II) measurements from several years before the eruption and ECC sonde measurements from the year prior to the eruption to determine the resulting changes. Ozone decreases of up to 33 % compared with SAGE II climatological values were found to be directly correlated with altitude regions of enhanced aerosol loading in the 16- to 28-km range. A maximum partial-column decrease of 29 +/- Dobson units (DU) was found over the 16- to 28-km range in September 1991 along with small increases (to 5.9 +/- 2 DU) from 28 to 31.5 km. A large decrease of ozone was also found at 4 deg to 8 deg S from May to August 1992, with a maximum decrease of 33 +/- 7 DU found above Brazzaville in July. Aerosol data form the visible channel of the advanced very high resolution radiometer (AVHRR) and the visible wavelength of the UV DIAL system were used to examine the relationship between aerosol (surface area) densities and ozone changes. The tropical stratospheric ozone changes we observed in 1991 and 1992 are likely be explained by a combination of dynamical (vertical transport) perturbations, radiative perturbations on ozone photochemistry, and heterogeneous chemistry.

Grant, William B.↗

Statistical Mining of Predictability of Seasonal Precipitation over the United States

Results from a new ensemble canonical correlation (ECC) prediction model yield a remarkable (10-20%) increases in baseline prediction skills for seasonal precipitation over the US for all seasons, compared to traditional statistical predictions. While the tropical Pacific, i.e., El Nino, contributes to the largest share of potential predictability in the southern tier States during boreal winter, the North Pacific and the North Atlantic are responsible for enhanced predictability in the northern Great Plains, Midwest and the southwest US during boreal summer. Most importantly, ECC significantly reduces the spring predictability barrier over the conterminous US, thereby raising the skill bar for dynamical predictions.

Lau, William K. M.↗

A Characterization of Vertical Ozonesonde Measurements at the Equatorial Locations of SHADOZ

Beginning in 1997 ozonesonde observations have been obtained from Equatorial locations participating in SHADOZ (Southern Hemisphere Additional Ozone) Project. Vertical ozone profiles are available from the western Pacific eastward to Kenya. Presently 10 stations provide vertical ECC ozonesonde measurements at least weekly. Statistical analysis shows the variation that occurs in the level of maximum ozone, the difference between integrated total ozone overburden from ECC and EP-TOMS observations, and with Dobson Spectrophotometers, when data are available.

Schmidlin, F. J.↗

A Balloon Sounding Technique for Measuring SO2 Plumes

This paper reports on the development of a new technique for inexpensive measurements of SO2 profiles using a modified dual-ozonesonde instrument payload. The presence of SO2 interferes with the standard electrochemical cell (ECC) ozonesonde measurement, resulting in -1 molecule of O3 reported for each molecule of SO2 present (provided [O3] > [SO2]). In laboratory tests, an SO2 filter made with Cr03 placed on the inlet side of the sonde removes nearly 100% of the SO2 present for concentrations up to 60 ppbv and remained effective after exposure to 2.8 X 10(exp 16) molecules of SO2 [equivalent to a column approximately 150 DU (1 DU = 2.69 X 10(exp 20) molecules m(exp -2))]. Flying two ECC instruments on the same payload with one filtered and the other unfiltered yields SO2 profiles, inferred by subtraction. Laboratory tests and field experience suggest an SO2 detection limit of approximately 3 pbb with profiles valid from the surface to the ozonopause [i.e., approximately (8-10 km)]. Two example profiles demonstrate the success of this technique for both volcanic and industrial plumes.

Morris, Gary A.↗

Optimizing Parameters for Deep-Space Optical Communication

A paper discusses the optimization of the parameters of a high-rate, deep-space optical communication link that utilizes pulse-position modulation (PPM) and an error-correcting code (ECC). The parameters in question include the PPM order (number of pulse time slots in one symbol period), the ECC rate, and the uncoded symbol error rate. In simple terms, the optimization problem is to choose the combination of these parameters that maximizes the throughput data rate at a given bit-error-rate (BER), subject to several constraints, including limits on the average and peak power and possibly a limit on the uncoded symbol error rate. This is a complex, multidimensional optimization problem, the solution of which involves computation of channel capacities for various combinations of the parameters. The paper presents extensive theoretical analyses and numerical predictions that elucidate the many facets of the optimization problem. It shows how a nearly optimum solution can be obtained by choosing the optimum PPM order for the desired number of bits per slot and concatenating the PPM mapping with an error-correction code so that the decoded bits satisfy some BER threshold.

Moison, Bruce↗

Propagation of Radiosonde Pressure Sensor Errors to Ozonesonde Measurements

Several previous studies highlight pressure (or equivalently, pressure altitude) discrepancies between the radiosonde pressure sensor and that derived from a GPS flown with the radiosonde. The offsets vary during the ascent both in absolute and percent pressure differences. To investigate this problem further, a total of 731 radiosonde-ozonesonde launches from the Southern Hemisphere subtropics to Northern mid-latitudes are considered, with launches between 2005 - 2013 from both longer-term and campaign-based intensive stations. Five series of radiosondes from two manufacturers (International Met Systems: iMet, iMet-P, iMet-S, and Vaisala: RS80-15N and RS92-SGP) are analyzed to determine the magnitude of the pressure offset. Additionally, electrochemical concentration cell (ECC) ozonesondes from three manufacturers (Science Pump Corporation; SPC and ENSCI-Droplet Measurement Technologies; DMT) are analyzed to quantify the effects these offsets have on the calculation of ECC ozone (O3) mixing ratio profiles (O3MR) from the ozonesonde-measured partial pressure. Approximately half of all offsets are 0.6 hPa in the free troposphere, with nearly a third 1.0 hPa at 26 km, where the 1.0 hPa error represents 5 persent of the total atmospheric pressure. Pressure offsets have negligible effects on O3MR below 20 km (96 percent of launches lie within 5 percent O3MR error at 20 km). Ozone mixing ratio errors above 10 hPa (30 km), can approach greater than 10 percent ( 25 percent of launches that reach 30 km exceed this threshold). These errors cause disagreement between the integrated ozonesonde-only column O3 from the GPS and radiosonde pressure profile by an average of +6.5 DU. Comparisons of total column O3 between the GPS and radiosonde pressure profiles yield average differences of +1.1 DU when the O3 is integrated to burst with addition of the McPeters and Labow (2012) above-burst O3 column climatology. Total column differences are reduced to an average of -0.5 DU when the O3 profile is integrated to 10 hPa with subsequent addition of the O3 climatology above 10 hPa. The RS92 radiosondes are superior in performance compared to other radiosondes, with average 26 km errors of -0.12 hPa or +0.61 percent O3MR error. iMet-P radiosondes had average 26 km errors of -1.95 hPa or +8.75 percent O3MR error. Based on our analysis, we suggest that ozonesondes always be coupled with a GPS-enabled radiosonde and that pressure-dependent variables, such as O3MR, be recalculated-reprocessed using the GPS-measured altitude, especially when 26 km pressure offsets exceed 1.0 hPa 5 percent.

pressure measurements↗

Ozonesonde Quality Assurance: JOSIE-SHADOZ (2017) and SHALLOTS (2018)

Ozonesonde data constitute a mainstay of satellite calibration and are used for climatologies and analysis of trends, especially in the lower stratosphere where satellites are most uncertain. The electrochemical-concentration cell (ECC) ozonesonde has been deployed at ~100 stations worldwide since the 1960s, with changes over time in manufacture and procedures, including details of the cell chemical solution and data processing. As a consequence, there are biases among different stations and discontinuities in profile timeseries from individual site records. Since 1996 the Jülich [Germany] Ozone Sonde Intercomparison Experiment (JOSIE) has periodically tested ozonesondes in a simulation chamber designated the World Calibration Centre for Ozonesondes by WMO. In October- November 2017 a JOSIE campaign evaluated the sondes and procedures used in SHADOZ (Southern Hemisphere Additional Ozonesondes), a 14-station tropical and subtropical network. A distinctive feature of the 2017 JOSIE was that the tests were conducted by operators from eight SHADOZ stations; Nairobi, Natal, Irene, Costa Rica, Paramaribo, Reunion, Hanoi, Kuala Lumpur. Experimental protocols and preliminary results for the SHADOZ sonde configurations, which represent most of those in use today, are described. SHADOZ stations that follow WMO-recommended protocols record total ozone within 3% of the JOSIE reference instrument. Instrument biases noted in prior JOSIE and field tests like BESOS (2004) were noted in JOSIE-2017, with maximum effect in the stratosphere. In June 2018 we organized a series of dual launches during the OWLETS II campaign in the Maryland and Chesapeake Bay area (SHALLOTS = SHADOZ-OWLETS ParaLLel Ozonesonde Test Study). Instrument and solution types were varied as in JOSIE-2017 and three radiosonde-ozonesonde variants were tested. An example of a parallel sampling in SHALLOTS, from a Greenbelt EnSCI-iMet sonde combination flown with the Wallops SPCLMS package, is illustrated in the Figure. The result was a range of biases but in general the instrument combination (EnSCI-iMet) deployed at 11 SHADOZ stations recorded ~5-10% less ozone in the stratosphere than the SPC ECC sonde flown with a Vaisala or LMS system. These 2017 and 2018 results and prior JOSIEs demonstrate that regular testing is essential to maintain best practices in ozonesonde operations and to ensure high-quality data for the ozone assessment communities.

Quality assurance↗

Passive techniques for long-term reactor cooling

In a pressurized water reactor (PWR), emergency core cooling (ECC) responds to depressurization due to a vessel penetration break at the top of the pressure vessel by draining water from a body of water through an injection line into the pressure vessel. A barrier operates concurrently with the ECC to suppress flow of liquid water from the pressure vessel out the vessel penetration break. The barrier may comprise one or more of: (1) an injection line extension passing through the central riser to drain water into the central riser; (2) openings in a lower portion of a central riser to shunt some upward flow from the central riser into a lower portion of the downcomer annulus; and (3) a surge line providing fluid communication between a pressurizer volume at the top of the pressure vessel and the remainder of the pressure vessel which directs water outboard toward the downcomer annulus.

Malloy, III, John D.↗

Evaluating direct vessel injection accident-event progression of AP1000 and key figures of merit to support the design and development of water-cooled small modular reactors

The passive safety systems (PSSs) within water-cooled reactors are meticulously engineered to function autonomously, requiring no external power source or manual intervention. They depend exclusively on inherent natural forces and the fundamental principles of reactor physics, such as gravity, natural convection, and phase changes, to manage, alleviate, and avert the release of radioactive materials into the environment during accident scenarios like a loss-of-coolant accident (LOCA). PSSs are already integrated into such operating commercial reactors as the Advanced Pressurized Reactor-1000 MWe (AP1000) and the Water-Water Energetic Reactor-1200 MWe (WWER-1200) are adopted in most of the upcoming small modular reactor (SMR) designs. Examples of water-cooled SMR PSSs are the passive emergency core-cooling system (ECCS), passive containment cooling system (PCCS), and passive decay-heat removal system, the designs of which vary based on reactor system-design requirements. However, understanding the accident-event progression and phases of a LOCA is pivotal for adopting a specific PSS for a new SMR design. This study covers the accident-event progression for direct vessel injection (DVI) small-break loss-of-coolant accident (SB-LOCA), associated physics phenomena, knowledge gaps, and important figures of merit (FOMs) that may need to be evaluated and assessed to validate thermal-hydraulics models with an available experimental dataset to support new SMR design and development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synthesis, Properties, and Electrochemical Proton Reduction of a Homoleptic Tetrathiolato Ni-Site Model of [NiFe]-Hydrogenase

[NiFe]-hydrogenase enzymes process H 2 at a nonplanar tetracysteinato-Ni site, the sole participator in proton binding/redox chemistry during turnover. With the objective of assessing whether a simple tetrahedral/ tetrathiolato-Ni 2+ core could promote H 2 evolution reaction (HER), we synthesized (Et 4 N) 2 [Ni(S-p-CF 3 −Ph) 4 ] (1) employing para-trifluoromethylbenzenethiolate ( − S-p-CF 3 −Ph) as a Ni-site analog of [NiFe]-hydrogenase. Spectroscopic measurements and X-ray crystallography confirm the distorted tetrahedral geometry of 1. Dissolution of 1 results in partial thiolate dissociation and formation of S,S-bridged complexes such as (Et 4 N) 2 [Ni 2 (S-p-CF 3 −Ph) 6 ] (3) among other ill-defined species. Dissociation is further accelerated in the presence of Brønsted acids, complicating the assessment of 1 for proton reduction. However, this dissociation/proton instability is suppressed in the presence of additional thiolate ligand to ensure tetrahedral/tetrathiolato 1 persists in solution. Electrochemical HER activity was evaluated by monitoring the current response of an MeCN solution of 1/ excess thiolate after sequential titration with a weak Brønsted acid (acetic acid). The results suggest that 1 is a modest electrocatalyst for the HER with a turnover frequency of 14.5 ± 3.6 s −1 and an overpotential of 0.72 ± 0.02 V. Control experiments and supplementary DFT computations indicate that 1, or a species derived from 1, is responsible for the HER and suggest an ECCE-type mechanism.

Evolution reactions↗

A Strong Anthropogenic Black Carbon Forcing Constrained by Pollution Trends Over China

Estimates of the effective radiative forcing from aerosol-radiation interaction (ERF ari ) of anthropogenic Black Carbon (BC) have been disputable and require better constraints. Here we find a substantial decline in atmospheric absorption of −5.79Wm −2 decade −1 over eastern central China (ECC) responding to recent anthropogenic BC emission reductions. By combining the observational finding with advances from Coupled Model Intercomparison Project phase6 (CMIP6), we identify an emergent constraint on the ERF ari of anthropogenic BC. We show that across CMIP6 models the simulated trends correlate well with simulated annual mean shortwave atmospheric absorption by anthropogenic BC over China. Making use of this emergent relationship allows us to constrain the aerosol absorption optical depth of anthropogenic BC and further provide a constrained range of 2.4–3.0 Wm −2 for its top-of-atmosphere ERF ari over China, higher than existing estimates. Furthermore, our work supports a strong warming effect of BC over China, and highlights the need to improve BC simulations over source regions.

CMIP6 models↗

Dynamic Transmission Line Switching Amid Wildfire-Prone Weather Under Decision-Dependent Uncertainty

During dry and windy seasons, environmental conditions significantly increase the risk of wildfires, exposing power grids to disruptions caused by transmission line failures. Wildfire propagation exacerbates grid vulnerability, potentially leading to prolonged power outages. To address this challenge, we propose a multistage optimization model that dynamically adjusts transmission grid topology in response to wildfire propagation, aiming to develop an optimal response policy. By accounting for decision-dependent uncertainty, where line survival probabilities depend on usage, we employ distributionally robust optimization to model uncertainty in line survival distributions. We adapt the stochastic nested decomposition algorithm and derive a deterministic upper bound for its finite convergence. To enhance computational efficiency, we exploit the Lagrangian dual problem structure for a faster generation of Lagrangian cuts. Using realistic data from the California transmission grid, we demonstrate the superior performance of dynamic response policies against two-stage alternatives through a comprehensive case study. In addition, after solving the multistage formulation, we construct easy-to-implement policies that significantly reduce computational burden while maintaining good performance in real-time deployment. History: Accepted by Russell Bent, Area Editor for Network Optimization: Algorithms and Applications. Funding: This work was supported by the U.S. Department of Energy, Office of Electricity [Grant DE-AC02-05CH11231]. The work of R. Jiang was supported in part by the U.S. National Science Foundation, Division of Electrical, Communications and Cyber Systems [Grant ECCS-1845980] and the U.S. Air Force Office of Scientific Research [Grant FA9550-23-1-0323]. Supplemental Material: The software that supports the findings of this study is available within the paper and its Supplemental Information ( https://pubsonline.informs.org/doi/suppl/10.1287/ijoc.2025.1210 ) as well as from the IJOC GitHub software repository ( https://github.com/INFORMSJoC/2025.1210 ). The complete IJOC Software and Data Repository is available at https://informsjoc.github.io/ .

Estrada-Garcia, Juan-Alberto↗

Comparative analysis of energy deposition modes available in Serpent 2 within the framework of the supercritical water reactor - Fuel qualification test reactor physics benchmark

A joint European Canadian Chinese development of a supercritical water-cooled small modular reactor (SCW-SMR) technology is in progress since September 2020 in the framework of a Horizon 2020 project called ECC-SMART. As a main purpose of the project, proper estimates of energy deposition and its spatial distribution are prerequisites for the accurate analysis of safety related parameters of the SCW-SMR concept under development. A supercritical water reactor fuel computational benchmark model, provided by Canadian Nuclear Laboratories, was applied for detailed comparison of different energy deposition calculation options available in the Serpent 2 Monte Carlo code. The effect of energy deposition options on the normalization of the results as well as on the spatial distribution of the energy deposition are discussed. Consistent energy deposition calculation methods are presented between three Monte Carlo codes, viz., Serpent 2, MCNP6 and OpenMC. Although resource-intensive, the use of the coupled neutron-photon transport mode of Serpent 2 is recommended for accurate spatial and quantitative characterization of energy deposition in the SCW-SMR fuel assemblies, accounting for both neutron and photon heating of all the materials. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safety Analysis for Accident-Tolerant Fuels with Increased Enrichment and Extended Burnup

The ERP research and development efforts in FY22 focused on the safety analysis of ATF with increased enrichment and extended burnup to provide scientific knowledge of the ATF fuel performance, failure mechanism and source term analysis during severe accident of the NPP. FeCrAl clad ATF was selected as basis of the reactor fuel. An optimized equilibrium cycle was developed for 24-months extended burnup operation. A 4-loop PWR model under loss-of-coolant accident (LOCA) was assessed and the behavior of the major source term from failed ATF has been analyzed. The result showed that grace to enhanced mechanical characteristics of ATF, the fuel failure starts up to 200~500 seconds later than conventional Zr clad fuel. This time gives sufficient buffer until low pressure safety injection (LPSI) of the emergency core cooling system (ECCS) restarted by the operator which reduces fuel fragmentation, relocation and dispersal (FFRD). As a consequence, the total amount of major radioactive materials released from FeCrAl clad fuel into the reactor containment was found up to three times less compare to Zr clad fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi physics simulation on Reactor Pressure Vessel (RPV) subjected to Pressurized Thermal Shock (PTS) by using Cardinal

The structural components that comprise nuclear reactors and their supporting structures are subjected to harsh operating environments that can challenge their integrity, especially after exposure for extended durations or under accident condition. As one of the most significant components of a Reactor, the Reactor Pressure Vessel (RPV) is exposed to an aggressive environment during the operation time (e.g. more than 40 years). Ageing degradation mechanisms (e.g. thermo-fatigue) could grow initial defects up to a critical size, increasing the susceptibility to failure in the RPV. The conventional methods are mostly based on simple crack and structure geometries. Very limited studies consider the real conditions of the RPV subjected to a thermal shock due to a Loss of Coolant Accident (LOCA). During a LOCA event, the most severe conditions take place when the emergency core cooling (ECC) water is injected inside the cold legs filled initially with hotter water and/or steam. The rapid cooling of the down-comer and the internal RPV surface followed probably by re-pressurization of the RPV causes large temperature gradients and variation of pressure which induces thermal-mechanical stresses. In order to develop the model for integrity assessment of a reactor pressure vessel (RPV) subjected to pressurized thermal shock (PTS), a multi-physics simulation, which includes the thermo-hydraulic, thermo-mechanical and fracture mechanics analyses is necessary.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗