Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Drift chambers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, D L , in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ~70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure D L = 3.74 +0.28 -0.29 cm 2 /s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wire-cell 3D pattern recognition techniques for neutrino event reconstruction in large LArTPCs: algorithm description and quantitative evaluation with MicroBooNE simulation

Wire-Cell is a 3D event reconstruction package for liquid argon time projection chambers. Through geometry, time, and drifted charge from multiple readout wire planes, 3D space points with associated charge are reconstructed prior to the pattern recognition stage. Pattern recognition techniques, including track trajectory and dQ/dx (ionization charge per unit length) fitting, 3D neutrino vertex fitting, track and shower separation, particle-level clustering, and particle identification are then applied on these 3D space points as well as the original 2D projection measurements. A deep neural network is developed to enhance the reconstruction of the neutrino interaction vertex. Compared to traditional algorithms, the deep neural network boosts the vertex efficiency by a relative 30% for charged-current ν e interactions. Therefore, this pattern recognition achieves 80–90% reconstruction efficiencies for primary leptons, after a 65.8% (72.9%) vertex efficiency for charged-current ν e (ν μ ) interactions. Based on the resulting reconstructed particles and their kinematics, we also achieve 15-20% energy reconstruction resolutions for charged-current neutrino interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

Cosmic Ray Background Rejection with Wire-Cell LArTPC Event Reconstruction in the MicroBooNE Detector

For a large liquid-argon time-projection chamber (LArTPC) operating on or near the Earth’s surface to detect neutrino interactions, the rejection of cosmogenic background is a critical and challenging task because of the large cosmic-ray flux and the long drift time of the time-projection chamber. We introduce a superior cosmic background rejection procedure based on the Wire-Cell three-dimensional (3D) event reconstruction for LArTPCs. From an initial 1:20 000 neutrino to cosmic-ray background ratio, we demonstrate these tools on data from the MicroBooNE experiment and create a high-performance generic neutrino event selection with a cosmic contamination of 14.9% (9.7%) for a visible energy region greater than O(200) MeV. The neutrino interaction selection efficiency is 80.4% and 87.6% for inclusive ν μ charged-current and ν e charged-current interactions, respectively. Here, this significantly improved performance compared with existing reconstruction algorithms marks a major milestone toward reaching the scientific goals of LArTPC neutrino oscillation experiments operating near the Earth’s surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

SBND Analysis using ML Reconstruction Chain

As part of the Short Baseline Neutrino (SBN) Program at Fermilab, the Short Baseline Near Detector (SBND) is positioned in the Booster Neutrino Beam (BNB) and explores neutrino-argon interactions with unprecedented statistics. SBND is a Liquid Argon Time Projection Chamber (LArTPC). Electrons produced through ionization drift toward three wire planes, providing signals that form 2D images of particle trajectories. I introduce the Scalable Particle Imaging using Neural Embeddings (SPINE) framework, which employs a Machine Learning (ML)-based 3D reconstruction using a series of neural networks. Here, we present SPINE’s reconstruction chain, analysis approaches, and results from our latest simulation samples.

43 PARTICLE ACCELERATORS↗

Apollo 16, LM-11 descent propulsion system final flight evaluation

The performance of the LM-11 descent propulsion system during the Apollo 16 missions was evaluated and found satisfactory. The average engine effective specific impulse was 0.1 second higher than predicted, but well within the predicted one sigma uncertainty of 0.2 seconds. Several flight measurement discrepancies existed during the flight as follows: (1) the chamber pressure transducer had a noticeable drift, exhibiting a maximum error of about 1.5 psi at approximately 130 seconds after engine ignition, (2) the fuel and oxidizer interface pressure measurements appeared to be low during the entire flight, and (3) the fuel propellant quantity gaging system did not perform within expected accuracies.

Avvenire, A. T.↗

Development of a Methodology for Conducting Hall Thruster EMI Tests in Metal Vacuum Chambers of Arbitrary Shape and Size

While the closed-drift Hall thruster (CDT) offers significant improvement in performance over conventional chemical rockets and other advanced propulsion systems such as the arcjet, its potential impact on spacecraft communication signals must be carefully assessed before widespread use of this device can take place. To this end, many of the potentially unique issues that are associated with these thrusters center on its plume plasma characteristics and the its interaction with electromagnetic waves. Although a great deal of experiments have been made in characterizing the electromagnetic interference (EMI) potential of these thrusters, the interpretation of the resulting data is difficult because most of these measurements have been made in vacuum chambers with metal walls which reflect radio waves emanating from the thruster. This project developed a means of assessing the impact of metal vacuum chambers of arbitrary size or shape on EMI experiments, thereby allowing for test results to be interpreted properly. Chamber calibration techniques were developed and initially tested at RIAME using their vacuum chamber. Calibration experiments were to have been made at Tank 5 of NASA GRC and the 6 m by 9 m vacuum chamber at the University of Michigan to test the new procedure, however the subcontract to RIAME was cancelled by NASA memorandum on Feb. 26. 1999.

Gallimore, Alec D.↗

Correlated single- and few-electron backgrounds milliseconds after interactions in dual-phase liquid xenon time projection chambers

In this work, we characterize single- and few-electron backgrounds that are observed in dual-phase liquid xenon time projection chambers at timescales greatly exceeding a maximum drift time after an interaction. These instrumental backgrounds limit a detector's sensitivity to dark matter and cosmogenic neutrinos. Using the ~150g liquid xenon detector at Purdue University, we investigate how these backgrounds, produced after 122keV 57 Co Compton interactions, behave under different detector conditions. We find that the rates of single- and few-electron signals follow power-laws with time after the interaction. We observe linearly increasing rates with increased extraction field, and increased rates in the single-electron background with increased drift field. Normalizing the rates to the primary interaction's measured ionization signal, the rates increase linearly with the depth of the interaction. We test the hypothesis that infrared photons (1550nm) would stimulate and accelerate electron emission via photodetachment from impurities, but find that even 1 Watt of infrared light fails to reduce these backgrounds. We thus provide a characterization that can inform background models for low-energy rare event searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of dual-tip micromanometers during 21-day implantation in goats

Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.

Non-NASA Center↗

Exploring Novel Technologies for Particle Tracking in Gas TPCs (Final Technical Report)

This report provides the final results from R&D on a novel 2D readout for a time projection chamber (TPC), which operates with negative-ion drift. The readout consists of two gas electron multiplier (GEM) devices places at an angle with respect to each other. The 2D range of particles interacting in the TPC is reconstructed using pulse-shape timing only. Due to the low diffusion and drift speeds of the negative-ions carrying the track information to the anode, the track resolution is <200 microns. Acquiring this level of resolution for short, low energy particle tracks in a standard TPC would require a fine granularity strip or pixel readout with many 1000s of electronic channels. With this novel readout, only two channels are needed. Our results showed that the concept is fundamentally sound. We found a number of issues related to how well the timing signals are determined from the pulse waveforms. Solutions for these had to be left for future R&D.

47 OTHER INSTRUMENTATION↗

Near- and far scrape-off layer transport studies in detached, small-ELM ASDEX Upgrade discharges by means of EMC3-EIRENE

We compare various diagnostics characterizing an ASDEX Upgrade upper single-null discharge to EMC3-EIRENE simulations now including volumetric recombination and main chamber plasma-wall interaction but not yet drifts. The discharge is in a small-ELM regime and is approaching detachment due to a density ramp and nitrogen seeding. Time/ELM averaged upstream density, electron and ion temperature measurements as well as downstream ion saturation current, electron temperature and power flux measurements match the simulation within the error bars before and after reaching detachment, qualifying the code for this regime. Although the Ion Cyclotron Resonance Heating (ICRH) antenna limiters are 35 mm away from the separatrix, i.e. ten times the typical near-SOL power fall-off length $\lambda^{near}_q\ =\ $3.8 mm, they receive power fluxes of several hundreds of kW exceeding the ones to the outer target in the detached phase and strongly contribute to the particle fueling. This is explained by a substantially larger far-SOL power fall-off length $\lambda^{far}_q\ =\ $25 mm possibly caused by the small ELMs in the detached phase and the occurrence of a density shoulder.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Light detection with power and signal transmission over fiber

The Deep Underground Neutrino Experiment is a next generation long baseline (1300 km) neutrino oscillation experiment. The neutrino beam measurements will be performed by a near detector and far detector. The far detector will consist of four modules, installed 1.5 km deep underground, based on Liquid Argon Time Projection Chamber (LArTPC) technology to detect particles. The Vertical Drift (VD) LArTPC is a recent technology proposed by the DUNE collaboration for the second FD module. In VD, light collection will be optimized by embedding photon detectors within the LArTPC cathode, which is biased at −300 kV. As a result, power must arrive to the Photon Detection System and signal must be transmitted via non-conductive material. The proposed solution is to use Power-over-Fiber and Signal-over-Fiber. An intense validation of the system is being performed by the collaboration at the CERN Neutrino Platform. The design of the system and the results of the validation collected over the first half of 2022 are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating instabilities in magnetized low-pressure capacitively coupled RF plasma using particle-in-cell (PIC) simulations

The effect of a uniform magnetic field on particle transport in low-pressure radio frequency (RF) capacitively coupled plasma (CCP) has been studied using a particle-in-cell model. Three distinct regimes of plasma behavior can be identified as a function of the magnetic field. In the first regime at low magnetic fields, asymmetric plasma profiles are observed within the CCP chamber due to the effect of $\overrightarrow{E}$ × $\overrightarrow{B}$ drift. As the magnetic field increases, instabilities develop and form self-organized spoke-shaped structures that are distinctly seen within the bulk plasma closer to the sheath. In this second regime, the spoke-shaped coherent structures rotate inside the plasma chamber in the -$\overrightarrow{E}$ × $\overrightarrow{B}$ direction, where $\overrightarrow{E}$ × $\overrightarrow{B}$ are the DC electric and magnetic field vectors, respectively, and the DC electric field exists in the sheath and pre-sheath regions. The spoke rotation frequency is in the megahertz range. As the magnetic field strength increases further, the rotating coherent spokes continue to exist near the sheath. The coherent structures are, however, accompanied by new small-scale incoherent structures originating and moving within the bulk plasma region away from the sheath. This is the third regime of plasma behavior. The threshold values of the magnetic field between these regimes were found not to vary with changing plasma reactor geometry (e.g., area ratio between ground and powered electrodes) or the use of an external capacitor between the RF-powered electrode and the RF source. The threshold values of the magnetic field between these regimes shift toward higher values with increasing gas pressure. Analysis of the results indicates that the rotating structures are due to the lower hybrid instability driven by density gradients and electron-neutral collisions. This paper provides guidance on the upper limit of the magnetic field for instability-free operation in low-pressure CCP-based semiconductor deposition and etch systems that use the external magnetic field for plasma uniformity control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. We report a detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid xenon time projection chamber for gamma rays in the MeV region: Development status

The feasibility of a large volume Liquid Xenon Time Projection Chamber (LXe-TPC) for three dimensional imaging and spectroscopy of cosmic gamma ray sources, was tested with a 3.5 liter prototype. The observation of induction signals produced by MeV gamma rays in liquid xenon is reported, with a good signal-to-noise ratio. The results represent the first experimental demonstration with a liquid xenon ionization chamber of a nondestructive readout of the electron image produced by point-like charges, using a sense wire configuration of the type originally proposed in 1970 by Gatti et al. An energy resolution as good as that previously measured by the millimeter size chambers, was achieved with the large prototype of 4.4 cm drift gap.

Aprile, E.↗

Detection of Chamber Conditioning by CF4 in the GEC Cell

During oxide etch processes, buildup of fluorocarbon residues on reactor sidewalks can cause to drift and will necessitate time for conditioning and cleaning of the reactor. Various measurements in CF4 and Ar plasmas are made in an attempt to identify a metric able to indicate the chamber condition. Mass spectrometry and a Langmuir probe shows that the buildup of fluorocarbon films on the reactor surface causes a decrease in plasma floating potential, plasma potential, and ion energy in argon plasmas. This change in floating potential is also observed in CF4 plasma operation, and occurs primarily during the first hour and a half of plasma operation. A slight rise in electron density is also observed in the argon plasmas. Because the change is seen in an argon plasma, it is indicative of altered physical, not chemical, plasma-surface interactions. Specifically, the insulating films deposited on metal surfaces alter the electromagnetic fields seen by the plasma, affecting various parameters including the floating potential and electron density. An impedance probe placed on the inductive coil shows a slight reduction in plasma impedance due to this rising electron density. The optical emission of several species, including CF, C2, atomic Si and atomic C, is also monitored for changes in density resulting from the buildup of film on the chamber wall. Changes in the optical emission spectrum are comparable to the noise levels in their measurement.

Cruden, Brett A.↗

The Nagoya cosmic-ray muon spectrometer 3, part 2: Track detector

The twelve wide gap spark chambers were utilized as the track detectors of the Nagoya cosmic-ray muon spectrometer not only to obtain the precise locations of particles, but also to get some information about the correspondences between segments of trajectories. The area of each chamber is 150 x 70 sq cm and the width of a gap is 5 cm. The gas used is He at the atmospheric pressure. Each three pairs of them are placed on both sides of the deflection magnet. All images of sparks for each event are projected through the mirror system and recorded by two cameras stereoscopically. The mean detection efficiency of each chamber is 95 + or - 2% and the spacial resolution (jitter and drift) obtained from the prototype-experiment is 0.12 mm. Maximum detectable momentum of the spectrometer is estimated at about 10 TeV/c taking into account these characteristics together with the effects of the energy loss and multiple Coulomb scattering of muons in the iron magnet.

Shibata, S.↗