Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Double Beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Status and new features of the topography beamline 1-BM after the Advanced Photon Source upgrade

The beamline 1-BM of the Advanced Photon Source (APS), a bending-magnet beamline with an effective X-ray beam size of ~100×4 mm2, has relatively comprehensive synchrotron topography and rocking curve imaging capabilities for characterization of crystals (particularly wide-bandgap semiconductors SiC, AlN, GaN, Ga2O3 etc). It is equipped with a white-beam topography stage for imaging large wafers up to 8 inches. It also has a double-crystal setup, of which the second stage can be used for monochromatic-beam topography. The first stage has different beam conditioners in the grazing-incidence geometry that can expand the vertical beam size from 4 to ~100 mm for double-crystal rocking curve imaging when it is combined with the second stage. Recently APS has been upgraded to a modern 4th-generation light source, and 1-BM has been recommissioned to its normal operation for general users with better performance. The upgraded APS leads to new features at 1-BM. The much smaller source size and higher X-ray coherence significantly improve the image resolution and contrast. The higher flux and brightness of the new source reduce exposure time, which mitigates the mechanical drifting and vibration issues. Here the main capabilities and status of 1-BM together with these new features are introduced.

X-ray topography↗

Accurate determination of the electron spin polarization in magnetized iron and nickel foils for Møller polarimetry

The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades. Past experiments have typically required polarimetry at the 1% level of absolute uncertainty which the Møller polarimeter has delivered. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4% (The MOLLER Collaboration, 2014; The SoLID collaboration, 2019), requiring a systematic re-examination of all the contributing uncertainties. Møller polarimetry uses the double polarized scattering asymmetry of a polarized electron beam on a target with polarized atomic electrons. The target is a ferromagnetic material magnetized to align the spins in a given direction. In Hall A, the target is a pure iron foil aligned perpendicular to the beam and magnetized out of plane parallel or antiparallel to the beam direction. The acceptance of the detector is engineered to collect scattered electrons close to 90° in the center of mass frame where the analyzing power is a maximum (-7/9). One of the leading systematic errors comes from determination of the target foil polarization. Polarization of a magnetically saturated target foil requires knowledge of both the saturation magnetization and g', the electron g-factor which includes components from both spin and orbital angular momentum from which the spin fraction of magnetization is determined. Target foil polarization has been previously addressed in a 1997 publication “A precise target for Møller polarimetry” by de Bever et al. (1997) at a level of precision sufficient for experiments up to this point. Several shortcomings with the previous published value require revisiting the result prior to MOLLER. Here, we utilize the existing world data to provide a best estimate for target polarization for both nickel and iron foils including uncertainties in magnetization, high-field and temperature dependence, and fractional contribution to magnetization from orbital effects. We determine the foil electron spin polarization at 294 K to be 0.08020 ± 0.00018 (@4 T applied field) for iron and 0.018845+/-0.000053 (@2 T applied field) for nickel. Finally, we conclude with a brief discussion of additional systematic uncertainties to Møller polarimetry using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative analysis of dislocations in 4H-SiC wafers using synchrotron X-ray topography with ultra-high angular resolution

Utilization of an Si(331) beam conditioner together with an Si(111) double-crystal monochromator (DCM) enables the angular resolution of synchrotron X-ray topography to be increased by an order of magnitude compared with grazing-incidence topography or back-reflection topography conducted with the DCM alone. This improved technique with extremely small beam divergence is referred to as synchrotron X-ray plane-wave topography (SXPWT). This study demonstrates that the rocking curve width of 4H-SiC 0008 in PWT is only 2.5" and thus the lattice distortion at the scale of 1" will significantly affect the diffracted intensity. This work reports the ultra-high angular resolution in SXPWT which enables detailed probing of the lattice distortion outside the dislocation core in 4H-SiC, where the sign of the Burgers vector can be readily determined through comparison with ray-tracing simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A portable on-axis laser-heating system for near-90° X-ray spectroscopy: application to ferropericlase and iron silicide

A portable IR fiber laser-heating system, optimized for X-ray emission spectroscopy (XES) and nuclear inelastic scattering (NIS) spectroscopy with signal collection through the radial opening of diamond anvil cells near 90°with respect to the incident X-ray beam, is presented. The system offers double-sided on-axis heating by a single laser source and zero attenuation of incoming X-rays other than by the high-pressure environment. A description of the system, which has been tested for pressures above 100 GPa and temperatures up to 3000 K, is given. The XES spectra of laser-heated Mg 0.67 Fe 0.33 O demonstrate the potential to map the iron spin state in the pressure–temperature range of the Earth's lower mantle, and the NIS spectra of laser-heated FeSi give access to the sound velocity of this candidate of a phase inside the Earth's core. This portable system represents one of the few bridges across the gap between laser heating and high-resolution X-ray spectroscopies with signal collection near 90°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DESIGNING THE SPREADERS AND SPLITTERS FOR THE FFA@CEBAF ENERGY UPGRADE

The FFA@CEBAF energy upgrade study aims to approximately double the final energy of the electron beam at the Continuous Electron Beam Accelerator Facility (CEBAF). It will do this by replacing the highest-energy recirculating arcs with fixed-field alternating gradient (FFA) arcs, allowing for several more passes to circulate through the machine. This upgrade necessitates the re-design of the vertical spreader sections, which separates each pass into different recirculation arcs. Additionally, the FFA arcs will need horizontal splitter lines to correct for time of flight and R56. This work will present the current state of the spreader re-design and splitter design.

Benesch, J.↗

Warm Unit Stand Analysis for Proton Improvement Project II

The Proton Improvement Project II, commonly referred to as PIP II, is a linear accelerator overhaul at Fermilab to eventually double the output of its existing proton beam to continue to be the leading force in high energy physics. The proton beam is created through a series of high frequency cryomodules that must be connected utilizing a combination of magnets and vacuum pumps to ensure the beam is properly aligned. A housing mechanism for the magnets and vacuum pumps (Warm Units) will be placed between the cryomodules for realignment and require multiple stages of 6 degree-of-freedom adjustment options, to ensure that the beam alignment can fit all realistic requirements. Extensive testing and design modifications on the Warm Unit stand was completed to confirm not only the strength of the unit in nominal configuration, but also at each possible adjustment orientation for each 6 degree-of-freedom option. Structural analysis was also completed for various unique loading conditions i ncluding transportation loading and confirming the unit satisfies international building code. Simultaneously, testing and design modifications were done to confirm that the frequency modes of the system resided outside of concern ranges, which is determined by Fermilab safety codes and is set to exceed 15 Hz. Design changes that simultaneously stiffen the system to raise the lowest frequency modes while expanding access for technicians and allow for easier fabrication were developed and implemented into the Warm Unit stand. Various relationships between the design changes and the overall vibrational patterns were also developed for future use and study as the rest of PIP II matures.

43 PARTICLE ACCELERATORS↗

Warm Unit Stand Assembly and Testing for Proton Improvement Plan - II

The Proton Improvement Project II (PIP II), situated at Fermilab, signifies a critical advancement in the realm of high-energy physics. PIP II, a linear accelerator renovation endeavor, aspires to double the output of the existing proton beam, reinforcing Fermilab’ s position as a vanguard in this field. The proton beam's creation involves a series of high-frequency cryomodules, necessitating environmental temperature arrays of magnets and vacuum pumps henceforth described as ‘Warm Units.’ The Warm Units include design features of : 1. insertion between the cryomodules, 2. multi-stage adjustments in six degrees of freedom to ensure precise beam alignment; 3. Natural frequency modes that avoid specified ranges. In adherence to Fermilab’ s stringent safety standards, comprehensive testing procedures are slated to validate the Warm Units' capacity to simultaneously achieve local alignment adjustments while averting low-frequency oscillation less than 15 Hertz. The testing regimen will scrutinize the Warm Units' alignment adjustment capabilities and their resilience against low-frequency oscillations, with an overarching objective of satisfying the Final Design Review criteria specific to the PIP II initiative. This project works to furnish technicians responsible for the assembly of Warm Units with a comprehensive guide for successful installation, concurrently documenting any requisite design modifications essential for achieving a real-world configuration.

43 PARTICLE ACCELERATORS↗

Full-Cycle Simulations of the Fermilab Booster

The Proton Improvement Plan phase II (PIP-II) project currently under construction at FNAL will replace the existing 400 MeV normal conducting linac with a new 800 MeV superconducting linac. The beam power in the downstream rapid-cycling Booster synchrotron will be doubled by raising the machine cycle frequency from 15 to 20 Hz and by increasing the injected beam intensity by a factor 1.5. This has to be accomplished without raising uncontrolled losses beyond the administrative limit of 500 W. In addition, slip-stacking efficiency in the Recycler, the next machine in the accelerator chain, sets an upper limit on the longitudinal emittance of the beam delivered by the Booster. As part of an effort to better understand potential losses and emittance blow-up in the Booster, we have been conducting full cycle 6D simulations using the code PyORBIT. The simulations include space charge, wall impedance effects and transition crossing. In this paper, we discuss our experience with the code and present representative results for possible operational scenarios.

43 PARTICLE ACCELERATORS↗

Full Cycle Simulations of The Fermilab Booster

The Proton Improvement Plan phase II (PIP-II) project currently under construction at FNAL will replace the existing 400 MeV normal conducting linac with a new 800 MeV superconducting linac. The beam power in the downstream rapid-cycling Booster synchrotron will be doubled by raising the machine cycle frequency from 15 to 20 Hz and by increasing the injected beam intensity by a factor 1.5. This has to be accomplished without raising uncontrolled losses beyond the administrative limit of 500 W. In addition, slip-stacking efficiency in the Recycler, the next machine in the accelerator chain, sets an upper limit on the longitudinal emittance of the beam delivered by the Booster. As part of an effort to better understand potential losses and emittance blow-up in the Booster, we have been conducting full cycle 6D simulations using the code PyORBIT. The simulations include space charge, wall impedance effects and transition crossing. In this paper, we discuss our experience with the code and present representative results for possible operational scenarios.

43 PARTICLE ACCELERATORS↗

Exploring Functional Materials by Understanding Beam‐Sample Interactions

Abstract Ultra‐low‐dose electron diffraction is performed with a double metal cyanide catalyst (DMC) to understand how electron irradiation stimulates structural alterations in functional materials. The commonly fading diffraction patterns with dose accumulation depend on the irradiated area and the beam current even when below 50 femto Amperes. Heat generation is observed and modeled by statistical, inelastic scattering events to describe how phonon excitations modulate radiation hardness. Specifically, the characteristic 1/e‐decay of Bragg intensities from DMC is delayed from 6 to 30 eÅ −2 at room temperature, which is comparable to the effect of embedding radiation soft matter in ice. DMC's radiation hardness is enhanced by a latency dose that forms during a phase transformation. This unifying model predicts that a critical dose rate exists for any material that varies between 0.1 and 10 4 eÅ −2 s −1 because of a material dependent competition of heat generation and spread. It shows that Brillouin scattering causes time dependent perturbations in electron irradiated solids that trigger time‐temperature‐transformations on a time scale of nanoseconds to microseconds at room temperature, which is not included in traditional models describing the decay of Bragg intensities by radiolysis.

Kisielowski, Christian↗

Discovery of 98 Sn Produced by the Projectile Fragmentation of a 345-MeV/Nucleon 124 Xe Beam

We present the discovery of a new isotope of $^{98}$Sn beyond the double-magic N = Z = 50 nucleus $^{100}$Sn. $^{98}$Sn was identified among the projectile-fragmentation products of a $^{124}$Xe beam at 345 MeV/nucleon at the RI Beam Factory, RIKEN, Japan. Additionally, we have confirmed the production of $^{96}$In and $^{94}$Cd, previously reported as new isotopes at RIKEN. These highly proton-rich nuclei were separated and identified using the large-acceptance two-stage separator BigRIPS. Furthermore, we have determined the cross sections of $^{98}$Sn and its neighboring nuclei. These experimental values were compared to the semi-empirical cross-section formula EPAX3.1a, resulting in a reduction of the predicted cross sections by roughly a factor of 5.

07 ISOTOPE AND RADIATION SOURCES↗

Window Cooling Studies using Pulsed Beam Heating

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 using electron accelerators. Two electron accelerators are used to irradiate a double sided target. LANL collaborates with NMR to experimentally investigate beam effects on the target which consists of two Inconel 718 windows on either side of a stack of Mo-100 disks. LANL simulates the beam heating using an induction heater.

43 PARTICLE ACCELERATORS↗

An Operationally Integrated Approach to the SNS 2.8 MW Power Upgrade

The SNS accelerator consist of a 1 GeV H⁻ linac and an accumulator ring producing a 1.4 MW pulsed proton beam which drives a spallation neutron source. The Proton Power Upgrade project will double the power capability from 1.4 to 2.8 MW by increasing the linac energy 30% and the beam current about 50%. Equipment upgrades include new superconducting RF cryomodules and supporting RF equipment, upgraded ring equipment, and upgraded high power target systems. An important aspect of the upgrade is a gradual power ramp-up starting in 2022 in which new equipment is installed during maintenance outages as it arrives.

Galambos, John D↗

Realization of AlSb in the Double-Layer Honeycomb Structure: A Robust Class of Two-Dimensional Material

Exploring new two-dimensional (2D) van der Waals (vdW) systems is at the forefront of materials physics. Here, through molecular beam epitaxy on graphene-covered SiC(0001), we report successful growth of AlSb in the double-layer honeycomb (DLHC) structure, a 2D vdW material which has no direct analogue to its 3D bulk and is predicted kinetically stable when freestanding. The structural morphology and electronic structure of the experimental 2D AlSb are characterized with spectroscopic imaging scanning tunneling microscopy and cross-sectional imaging scanning transmission electron microscopy, which compare well to the proposed DLHC structure. The 2D AlSb exhibits a bandgap of 0.93 eV versus the predicted 1.06 eV, which is substantially smaller than the 1.6 eV of bulk. We also attempt the less-stable InSb DLHC structure; however, it grows into bulk islands instead. Here, the successful growth of a DLHC material here opens the door for the realization of a large family of novel 2D DLHC traditional semiconductors with unique excitonic, topological, and electronic properties.

36 MATERIALS SCIENCE↗

Pulsed Beam Heating Analysis of Curved Inconel Window with Pressurized Helium Gas Cooling

Los Alamos National Laboratory (LANL) is working with NorthStar medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 using Rodotron electron accelerators. Two Rhodotron accelerators are used to irradiate a double sided target. LANL collaborates with NMR to experimentally investigate beam effects on the target which consists of two Inconel 718 windows on either side of a stack of Mo-100 discs. LANL simulates the beam heating using an induction heater.

07 ISOTOPE AND RADIATION SOURCES↗

Interframe-tunable ultrafast differential-displacement holography

Here we describe the details of a digital holographic microscopy diagnostic capable of quantifying both the topography and velocity of a km/s object with adjustable temporal sensitivity. This technique involves spatially multiplexing a double pulse reflected from a target with reference beams of precisely known temporal separation.

47 OTHER INSTRUMENTATION↗

Bus Design for the Poloidal Field Coils of the NSTX-Upgrade Fusion Device

The National Spherical Torus eXperiment (NSTX) has undergone a major upgrade to NSTX-U at Princeton Plasma Physics Laboratory (PPPL). NSTX upgrade (NSTX-U) will double the toroidal field, plasma current, and neutral beam injection heating power, as well as significantly increase the pulse duration. NSTX-U uses three poloidal field (PF) coils at the vessel top and three at the bottom near the divertor areas to control the local plasma shape there. These shaping coils operate at a maximum terminal voltage of 2 kV, corresponding to a maximum current about 20 kA. To supply the power to the PF coils, hard copper bus bars are typically used near the vacuum vessel, while water cooled flexible cables are used away from the vessel. The detailed design of the hard copper bus bars will be covered in this article. During operation, these hard bus bars are subject to high electromagnetic (EM) forces, thermal displacement loads, as well as plasma halo loads due to disruption. The EM, thermal, and structural analysis were performed, and the results revealed that, with the worst loads combined, the new design meets the NSTX-U thermal, structural, and fatigue cycle requirements. Finally, the manufacturing and installation process of the bus work will be discussed at the end of this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗